• 제목/요약/키워드: Ground property

검색결과 473건 처리시간 0.029초

어장이용의 기회비용접근법에 의한 공동소유 어업권의 손실보상금 분배연구 - A어촌계의 미역양식어업권의 취소보상액 분배사례를 중심으로 - (A Study on the Distribution of Compensation for Damages of Common Property Fisheries by Alternative Cost Approach of Utilizing Fishing Ground)

  • 김기수;강용주
    • 수산경영론집
    • /
    • 제34권1호
    • /
    • pp.9-30
    • /
    • 2003
  • This paper tries to suggest a rational proposal for the distribution of compensation of common property fisheries damages caused by a large scale coastal reclamation. For the purpose the paper introduces the approach of alternative cost of the use of fishing ground. The background of the paper is the legal conflict between tenants and non-tenants, both of whom are common owners of seaweed cultivation ground, in the distribution of compensation for damages. In principal, so far as the seaweed cultivation right is a common property of the fishing association, the compensation is also a common property of it. Therefore the distribution method of the compensation entirely depends on the decision of the association. But in case that the numbers of non-tenants is larger than those of tenants, the distribution of the compensation is usually unfavorable to the tenants even though the latter is the key contributor to the realization of present value of the common property. The paper aims to show an appropriate distribution method based on the economic principle of optimal distribution. In others words, the value added to the economic value of alternative use of the fishing ground should be distributed to the tenants. the value amount of alternative use of the fishing ground should be equally distributed to the members of the association.

  • PDF

Scaling of design earthquake ground motions for tall buildings based on drift and input energy demands

  • Takewaki, I.;Tsujimoto, H.
    • Earthquakes and Structures
    • /
    • 제2권2호
    • /
    • pp.171-187
    • /
    • 2011
  • Rational scaling of design earthquake ground motions for tall buildings is essential for safer, risk-based design of tall buildings. This paper provides the structural designers with an insight for more rational scaling based on drift and input energy demands. Since a resonant sinusoidal motion can be an approximate critical excitation to elastic and inelastic structures under the constraint of acceleration or velocity power, a resonant sinusoidal motion with variable period and duration is used as an input wave of the near-field and far-field ground motions. This enables one to understand clearly the relation of the intensity normalization index of ground motion (maximum acceleration, maximum velocity, acceleration power, velocity power) with the response performance (peak interstory drift, total input energy). It is proved that, when the maximum ground velocity is adopted as the normalization index, the maximum interstory drift exhibits a stable property irrespective of the number of stories. It is further shown that, when the velocity power is adopted as the normalization index, the total input energy exhibits a stable property irrespective of the number of stories. It is finally concluded that the former property on peak drift can hold for the practical design response spectrum-compatible ground motions.

접지시스템의 부식 방지를 위한 CNT/PVDF 복합막의 내부식 특성 (Anti-corrosion Property of the CNT/PVDF Composite Coating Films for Preventing the Corrosion of the Ground System)

  • 임영택;신백균;최선규;이선우
    • 한국전기전자재료학회논문지
    • /
    • 제27권11호
    • /
    • pp.736-739
    • /
    • 2014
  • In this paper, we propose a enhanced anti-corrosion property of the ground system by coating the CNT/PVDF composite film on it. Polymer material used for preventing the corrosion of ground system is polyvinylidene fluoride (PVDF), and conducting filler for obtaining conductivity of the composite film is multi-walled carbon nanotubes (MWCNTs). The MWCNTs were dispersed in the organic solvent of methyl ethyl ketone 2-butanone (MEK) with different concentration ratios, and the PVDF was solved in the MEK solvent with constant concentration ratio of 1 wt%. The CNT/PVDF composite solution was perpared by mixing and re-dispersing the CNT solution and the PVDF solution. Finally, the CNT/PVDF composite films were fabricated by the spray coating method using the above composite solution. Electrical conductivity, surface states, and anti-corrosion property of the CNT/PVDF composite films coated on the Cu substrate were evaluated. We found that the CNT/PVDF composite film showed relatively low resistance, hydrophobic surface state, and chemical stability. Consequently, we could improve the anti-corrosion property and maintain the electrical conductivity of the ground system by coating the CNT/PVDF composite film on it.

순환골재 세척수를 혼입한 고로슬래그 콘크리트의 압축강도 특성에 관한 실험적 연구 (An Experimental Study on the Compressive Strength Property of Concrete with Ground granulated Blast Furnace Slag Using Wash Water from Recycled Aggregates)

  • 정상경;신상엽;김영수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.34-35
    • /
    • 2015
  • The purpose of this study is to investigate the compressive strength property of concrete with Ground granulated blast furnace slag(GBFS) using wash water from recycled aggregate. When GBFS is reacted with water, it doesn't happen to hydraulic reaction but GBFS becomes latent hydraulic property in alkaline environment. For this reason, if it is possible to use wash water from recycled coarse aggregate as mixture water, GBFS have the advantage of early strength due to effect of activation. We investigated the compressive strength properties of GBFS concrete using wash water from recycled aggregate. According to the experimentation result, ICP-OES showed wash water from recycled coarse aggregate has a high alkali value of pH of 12. Also, compressive strength in early age using wash water can be improved as an activation.

  • PDF

대용량 터빈발전기에서 접지과전압 계전기의 동작 특성 (Dynamic Property of Ground Overvoltage Relay in Large Turbine Generator)

  • 김희동;이영준;김병한;안준영;채규진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1044-1047
    • /
    • 1999
  • This paper deals with the dynamic property of ground overvoltage relay in large turbine generator. Relay operation is based on detecting the fundamental voltages originating from the generator. Calculations of fault voltage and current are reviewed for the neutral ground resistance. The frequency, ampitude and waveform of individual harmonics were measured using power quality analyzer and memory hi-corder at the secondary side of ground potential transformer. The ac and dc high-potential tests were applied to evaluate the condition of generator, main and auxiliary transformer, isolated phase bus, potential transformer, surge capacitor and arrester.

  • PDF

EFFECTS OF MECHANICAL PROPERTY VARIABILITY IN LEAD RUBBER BEARINGS ON THE RESPONSE OF SEISMIC ISOLATION SYSTEM FOR DIFFERENT GROUND MOTIONS

  • Choun, Young-sun;Park, Junhee;Choi, In-Kil
    • Nuclear Engineering and Technology
    • /
    • 제46권5호
    • /
    • pp.605-618
    • /
    • 2014
  • The effects of variability of the mechanical properties of lead rubber bearings on the response of a seismic isolation system are investigated. Material variability in manufacturing, aging, and operation temperature is assumed, and two variation models of an isolation system are considered. To evaluate the effect of ground motion characteristics on the response, 27 earthquake record sets with different peak A/V ratios were selected, and three components of ground motions were used for a seismic response analysis. The response in an isolation system and a superstructure increases significantly for ground motions with low A/V ratios. The variation in the mechanical properties of isolators results in a significant influence on the shear strains of the isolators and the acceleration response of the superstructure. The variation provisions in the ASCE-4 are reasonable, but more strict variation limits should be given to isolation systems subjected to ground motions having low A/V ratios. For application of seismic isolation systems to safety-related nuclear structures, the variation in the material and mechanical properties of the isolation system should be properly controlled during the manufacturing and aging processes. In addition, special consideration should be given to minimize the accidental torsion caused by the dissimilarity in the stiffness variations of the isolators.

지하매설물 속성정보를 활용한 지반함몰 영향인자 분석 (Analysis of Ground Subsidence Influencing Factors Using Underground Facility Property Information)

  • 강재모;이성열;김진영;공명식
    • 한국지반환경공학회 논문집
    • /
    • 제25권1호
    • /
    • pp.5-11
    • /
    • 2024
  • 지반함몰은 인구 밀집도가 높은 도심지에서 주로 발생함으로, 발생 원인을 명확히 파악하여 사전에 대비할 필요가 있다. 지반함몰의 주요 발생원인은 지하매설관의 손상으로 인한 지반 내 공동 생성으로 보고되어 있으나, 지반함몰 발생을 예측하여 대비하기 위한 지하매설관의 속성정보 및 영향인자가 올바르게 구축되어 있지 않은 실정이다. 따라서 본 연구에서는 지하매설물 속성정보 중 지반함몰 발생과 유의미한 상관성을 나타내는 인자를 선정하고, 로지스틱 회귀분석을 통해 회귀식을 제안하였다. 이를 위해, 대상지역의 지하매설물 및 지반함몰 이력정보의 데이터를 수집하였고, 대상지역을 QGIS를 활용하여 100m×100m 크기의 Gird로 구분하였다. Gird 내부에 포함되어 있는 지하매설물 속성정보와 지반함몰 이력정보를 추출하여 전처리를 수행하고 데이터셋을 구축하여 상관분석을 수행하였다. 그 결과, 하수관과 통신관의 매설년도와 통신관, 열배관, 가스관의 평균심도를 제외한 인자가 지반함몰과 유의미한 상관성을 보이는 것으로 나타났다. 또한, 로지스틱 회귀분석을 통해 대상지역의 지반함몰 발생 여부 회귀식을 제안하였다.

4각 보행로보트의 무른 지형 보행제어 알고리듬 (A Control Algorithm for Quadruped Walking Robot Over Unknown Soft Ground)

  • 심갑종;이상희
    • 산업기술연구
    • /
    • 제11권
    • /
    • pp.65-72
    • /
    • 1991
  • In this paper, a control algorithm is discussed when the quadruped walking robot walks over the unknown soft ground. Firstly, it estimated the relationship between the foot force and the ground sinkage at the leg-placing phase. Secondly, the generated soil property is applied to the leg-supporting phase. If the attitude angle is changed by incorrect ground sinkage compensation, the control algorithm adjusts the attitude angle using simplified orientation orientation matrix.

  • PDF

그라우팅 재료가 지중 유효열전도도에 미치는 영향 (Effect of Grouting Materials on Ground Effective Thermal Conductivity)

  • 손병후
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3371-3376
    • /
    • 2007
  • The design of a ground-source heat pump system includes specifications for a ground loop heat exchanger where the heat transfer rate depends on the thermal conductivity of the ground. To evaluate this heat transfer property, in-situ thermal response tests on four vertical test boreholes with different grouting materials were conducted by adding a monitored amount of heat to water over various test lengths. By measuring the water temperatures entering and exiting the loop, water flow rate, and heat load, effective thermal conductivity values of the ground were determined. The effect of increasing thermal conductivity of grouting materials from 0.82 to 1.05 W/m$^{\circ}C$ resulted in overall increases in effective ground thermal conductivity by 25.8% to 69.5%.

  • PDF

Enhanced dissolution rates of piroxicam from the ground mixtures with chitin or chitosan

  • Koh, Ik-Bae;Shin, Sang-Chul;Lee, Yong-Bok
    • Archives of Pharmacal Research
    • /
    • 제9권1호
    • /
    • pp.55-61
    • /
    • 1986
  • To increase the dissolution rate of piroxicam, chitin and chitosan which are widely occurring biodegradable natural materials were used as drug carriers. The ground mixtures of piroxicam with chitin or chitosan were prepared by grinding in a ball mill. The dissolution rates of piroxicam from the ground mixtures were enhanced markedly than that from the physical mixtures or from intact piroxicam. The X-ray diffraction peaks disappeared in the ground mixture indicating the production of the amorphous form. The comparison of infrared spectra of the physical mixture and the ground minture showed an interaction such as association between the functional groups of piroxicam and chitin or chitosan in the molecular level. The weight losses in TGA curves shoed all the same patterns. However, in the ground mixture by DTA curve, the undothermic peak due to the fusion of piroxicam was disappeared indicating the different thermal property.

  • PDF