• 제목/요약/키워드: Ground potential rise

검색결과 143건 처리시간 0.023초

봉상접지극의 과도임피던스 특성 (Transient Impedance Characteristics of Grounding Rods)

  • 김일권;김점식;송재용;길경석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.568-572
    • /
    • 2000
  • This paper describes the experimental results of a transient impedance characteristics of grounding rods to a square pulse and standard lightning impulse current. The test were performed on single grounding rod($\phi$ 10mm, 1m) and triple-grounding rods( $\phi$ 10mm, 1m) of equilateral triangles with 5m spacing. For measurements of transient impedance, a pulse generator which can produce square wave of 30ns rise time and 20U Pulse duration was designed and fabricated. In the experiment, transient impedance of the grounding systems have been investigated from the recorded potential and current waveforms. The results showed that the value of the transient impedance is quite higher than the stationary resistance, and provide useful information for the value of a grounding system considered transient characteristics under a high frequency condition such as lightning stokes and ground-fault.

  • PDF

건축전기설비에 적용되는 접지시스템 문제점과 개선방안 (Problems and Improvement Method of Grounding System in Electrical Facilities)

  • 정용기;곽희로;신효섭;정춘병;남택주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.47-50
    • /
    • 2001
  • Presently the Korean grounding system uses TN system, multi-grounding method with TT independent grounding method. Nevertheless TN system can't exist with TT system in the technological terms. If they coexist, it causes ground-fault circuit not to operate, and brings about different electrical potential rise by customer system. It brings about serious problems for safety. This paper aims for improving method of grounding system based on the technical analysis on instances in foreign countries and Korea. Almost standards and construction manner were apt to be internationalized after WTO/TBT agreement was concluded. The internal grounding systems should meet the international criteria and reliability for safety, and be provided with technologically impeccable standards.

  • PDF

전력용 변전소에 설치된 메쉬 접지망의 고주파 임피던스 계산 (High Frequency Impedance Calculation of Grounding Meshes Installed at Power Substations)

  • 한풍;최창혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1578-1582
    • /
    • 1998
  • The ground potential rise generated by the switching surge or lightning stroke may be dangerous to personnel and cause damage to electronic control parts. For a first step to the transient performance analysis. high frequency impedances of grounding grids have been calculated and discussed. Grounding grids include 7 square grids from $10m{\times}10m$ to $80m{\times}80m$. The high frequency current was injected into the center and a corner of the grounding grid. The calculation results indicate that the impedance of the grounding grid is significantly influenced by frequency and the point of injection of the current. and the effective radius of a large grounding grid may be represented in $15{\sim}20m$.

  • PDF

A multivariate adaptive regression splines model for estimation of maximum wall deflections induced by braced excavation

  • Xiang, Yuzhou;Goh, Anthony Teck Chee;Zhang, Wengang;Zhang, Runhong
    • Geomechanics and Engineering
    • /
    • 제14권4호
    • /
    • pp.315-324
    • /
    • 2018
  • With rapid economic growth, numerous deep excavation projects for high-rise buildings and subway transportation networks have been constructed in the past two decades. Deep excavations particularly in thick deposits of soft clay may cause excessive ground movements and thus result in potential damage to adjacent buildings and supporting utilities. Extensive plane strain finite element analyses considering small strain effect have been carried out to examine the wall deflections for excavations in soft clay deposits supported by diaphragm walls and bracings. The excavation geometrical parameters, soil strength and stiffness properties, soil unit weight, the strut stiffness and wall stiffness were varied to study the wall deflection behaviour. Based on these results, a multivariate adaptive regression splines model was developed for estimating the maximum wall deflection. Parametric analyses were also performed to investigate the influence of the various design variables on wall deflections.

고속철도에 의한 통신회선 잡음전압 발생 원인 고찰 (A Study on Causes Generating Induced Noise Voltage on Telecommunications Cables Near to High-speed Rails)

  • 여상근;박찬원;김정태
    • 한국철도학회논문집
    • /
    • 제11권3호
    • /
    • pp.248-256
    • /
    • 2008
  • 본 논문은 고속철도 주변 통신회선에 발생되는 잡음전압의 실체 파악을 통해 전력유도잡음전압이 발생하지 않는 것을 증명하였으며, 국내통신회사 및 전파연구소에서 사용하고 있는 평형도 측정에서의 문제점과 계측 오류를 규명하며 표준 측정회로와 측정 조건을 ITU-T 국제 기준에 맞도록 개정할 것을 제안한다.

용담댐 발전소 접지설계를 위한 대지비저항 모델링 및 접지저항 추정 (Earth Resistivity Modelling and Grounding Resistance Estimation for Yongdam Dam Power Station Grounding Design)

  • 오민환;김형수;김종득
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1188-1191
    • /
    • 1998
  • Detailed estimation of subsurface resistivity distribution and accurate estimation of actual fault current coming into the grounding system are indispensible to optimun grounding system design. Especially, it is essential for efficient grounding design to estimate subsurface resistivity distribution quantitatively and logically. Accurate estimation of subsurface resistivity distribution has an absolute influence on calculating touch voltage, step voltage and ground potential rise (GPR) which are related with grounding design standard for human safety. In this study, thirty-three electrical sounding surveys were made in Yongdam Power Station to obtain detailed subsurface resistivity distribution and the sounding data were interpreted quantitatively using multi-layered model. The results of the quantitative resistivity models were adopted practically to calculate grounding resistance values. Analytical asymptotic equations and CDEGS program were used in grounding resistance calculation and the results were compared and reviewed in the study.

  • PDF

고속철도 시스템의 레일 전위 상승 해석 (Analysis on Voltage Rise of Rail in High speed Railway System)

  • 명성호;이재복;이종우;이장무
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1365-1367
    • /
    • 2000
  • In electric railway system, potential of rail has been risen, for return-current flows through rail. The magnitude of rising voltage is different to railway feed system, ground admittance of rail and the load current. If rising voltage of rail is large, electric shock can be occurred to passengers and maintenance-worker. In this paper, we estimate the rising voltage of rail in high speed railway system and check the safety to human beings.

  • PDF

DC 급전계통 고저항 지락보호에 대한 연구 (A Study on High Impedance Grounding Protection for DC Power Supply System)

  • 이국명;김병현;소선영;김학련
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.878-884
    • /
    • 2006
  • Grounding fault and short of the DC power supply systems are detected and protected by high-speed circuit breaker, linked breaking device, ground relay and fault selective device, all of which are installed and operated in substaions. however, there have been many cases in which the protective devices did not detect grounding of of the over head catenary systems on concrete support for an extended period of time. Such cases often cause severe damages to the supports with high grounding resistances. If grounding accidents occur repetitively, the earth current and the rise of earth potential can damage not only passenger and staff but also electric facilities and equipment, necessitating high cost and endeavor to restore. The following study points out various problems that can be occurred occur as a result of high impedance grounding accident, and proposes a new system which can protect and intercept them.

  • PDF

Bioactivities and Potential Mechanisms of Action for Conjugated Fatty Acids

  • Park, Yeon-Hwa;Pariza, Michael W.
    • Food Science and Biotechnology
    • /
    • 제18권3호
    • /
    • pp.586-593
    • /
    • 2009
  • Since conjugated linoleic acid (CLA) was identified as a principal anticancer component from ground beef in the 1980s, CLA research has discovered that CLA has a wide range of biologically beneficial effects. Clinical studies with CLA are on the rise, and it is apparent that CLA may not be as effective in humans as in rodents, in particular its anti-obesity aspect. In addition, research with regard to other conjugated fatty acids as well as CLA metabolites is still in its infancy. Investigation of bioactivities for other conjugated fatty acids and CLA metabolites may help to extend the understanding of CLA and its mechanisms of actions. This may pose an opportunity to use CLA more efficiently and expand the future use of other conjugated fatty acids as pharmacological agents to assist current treatments.

건물의 직격뢰시 본딩 방식에 따른 서지 진압 분포 (Surge Voltage Distribution at the Different Bonding Practice During a Direct Lightning Stroke to Building)

  • 이재복;장석훈;명성호;조연규
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.444-450
    • /
    • 2008
  • There are several ways to bond to building grounding systems for reducing GPR(ground potential rise) and EMI resulting from power system faults or lightning stroke to building. In order to verify effective bonding practice, the GPR and voltage of equipment due to the direct stroke to building are calculated with ATP-EMTP model for transformer, transmission line and MOV(Metal oxide varistor). The simulated model shows a satisfactory accuracy compared with experimental result for the $8/20{\mu}s$ simulated current pulse. It is observed that separate grounding can cause dangerous voltage to the building equipment and the performance of surge protective device can improve when it is installed to the protected equipment in distance as short as possible.