• 제목/요약/키워드: Ground plan

Search Result 571, Processing Time 0.028 seconds

International Case Studies on the Eco-friendly Energy Towns with Hybrid Thermal Energy Supply System and Borehole Thermal Energy Storage (BTES) (친환경에너지타운에서 보어홀지중열 저장(BTES) 활용 융복합 열에너지 공급 시스템 사례 연구)

  • Shim, Byoung Ohan
    • Economic and Environmental Geology
    • /
    • v.51 no.1
    • /
    • pp.67-76
    • /
    • 2018
  • This study reviews three eco-friendly energy towns with hybrid thermal energy supply systems and borehole thermal energy storage (BTES) in Canada and Denmark. The district heating and cooling systems were designed by using multi-source energy for the higher efficiency and reliability as well as environment. ADEU (Alexandra District Energy Utility) located at the developing area in the city of Richmond, Canada was designed to supply district energy with the installation of 726 borehole heat exchangers (BHEs) and a backup boiler using natural gas. DLSC (Drake Landing Solar Community) located in the town of Okotoks, Canada is a district system to store solar thermal energy underground during the summer season by seasonal BTES with 144 BHEs. Brædstrup Solpark district heating system located in Denmark has been conducted energy supply from multiple energy sources of solar thermal, heat pump, boiler plants and seasonal BTES with 48 BHEs. These systems are designed based on social and economic benefits as well as nature-friendly living space according to the city based energy perspective. Each system has the energy center which distribute the stored thermal energy to each house for heating during the winter season. The BHE depth and ground thermal storage volume are designed by the heating and cooling load as well as the condition of ground water flow and thermophysical properties of the ground. These systems have been proved the reliance and economic benefits by providing consistent energy supply with competitive energy price for many years. In addition, the several expansions of the service area in ADEU and Brædstrup Solpark have been processed based on energy supply master plan. In order to implement this kind of project in our country, the regulation and policy support of government or related federal organization are required. As well as the government have to make a energy management agency associated with long-term supply energy plan.

A Study on Differences of Opinions on Home Health Care Program among Physicians, Nurses, Non-medical personnel, and Patients. (가정간호 사업에 대한 의사, 간호사, 진료관련부서 직원 및 환자의 인식 비교)

  • Kim, Y.S.;Lim, Y.S.;Chun, C.Y.;Lee, J.J.;Park, J.W.
    • The Korean Nurse
    • /
    • v.29 no.2
    • /
    • pp.48-65
    • /
    • 1990
  • The government has adopted a policy to introduce Home Health Care Program, and has established a three stage plan to implement it. The three stage plan is : First, to amend Article 54 (Nurses for Different Types of Services) of the Regulations for Implementing the Law of Medical Services; Second, to tryout the new system through pilot projects established in public hospitals and clinics; and third, to implement at all hospitals and equivalent medical institutions. In accordance with the plan, the Regulation has been amend and it was promulgated on January 9,1990, thus establishing a legal ground for implementing the policy. Subsequently, however, the Medical Association raised its objection to the policy, causing a delay in moving into the second stage of the plan. Under these circumstances, a study was conducted by collecting and evaluating the opinions of physicians, nurses, non-medical personnel and patients on the need and expected result from the home health care for the purpose of help facilitating the implementation of the new system. As a result of this study, it was revealed that: 1. Except the physicians, absolute majority of all other three groups - nurses, non-medical personnel and patients -gave positive answers to all 11 items related to the need for establishing a program for Home Health Care. Among the physicians, the opinions on the need for the new services were different depending on their field of specialty, and those who have been treating long term patients were more positive in supporting the new system. 2. The respondents in all four groups held very positive view for the effectiveness and the expected result of the program. The composite total of scores for all of 17 items, however, re-veals that the physicians were least positive for the- effectiveness of the new system. The people in all four groups held high expectation on the system on the ground that: it will help continued medical care after the discharge from hospitals; that it will alleviate physical and economic burden of patient's family; that it will offer nursing services at home for the patients who are suffering from chronic disease, for those early discharge from hospital, or those who are without family members to look after the patients at home. 3. Opinions were different between patients( who will receive services) and nurses (who will provide services) on the types of services home visiting nurses should offer. The patients wanted "education on how to take care patients at home", "making arrangement to be admitted into hospital when need arises", "IV injection", "checking blood pressure", and "administering medications." On the other hand, nurses believed that they can offer all 16 types of services except "Controlling pain of patients", 4. For the question of "what types of patients are suitable for Home Health Care Program; " the physicians, the nurses and non-medical personnel all gave high score on the cases of "patients of chronic disease", "patients of old age", "terminal cases", and the "patients who require long-term stay in hospital". 5. On the question of who should control Home Health Care Program, only physicians proposed that it should be done through hospitals, while remaining three groups recommended that it should be done through public institutions such as public health center. 6. On the question of home health care fee, the respondents in all four groups believed that the most desireable way is to charge a fixed amount of visiting fee plus treatment service fee and cost of material. 7. In the case when the Home Health Care Program is to be operated through hospitals, it is recommended that a new section be created in the out-patient department for an exclusive handling of the services, instead of assigning it to an existing section. 8. For the qualification of the nurses for-home visiting, the majority of respondents recommended that they should be "registered nurses who have had clinical experiences and who have attended training courses for home health care". 9. On the question of if the program should be implemented; 74.0% of physicians, 87.5% of non-medical personnel, and 93.0% of nurses surveyed expressed positive support. 10. Among the respondents, 74.5% of -physicians, 81.3% of non-medical personnel and 90.9% of nurses said that they would refer patients' to home health care. 11. To the question addressed to patients if they would take advantage of home health care; 82.7% said they would if the fee is applicable to the Health Insurance, and 86.9% said they would follow advises of physicians in case they were decided for early discharge from hospitals. 12. While 93.5% of nurses surveyed had heard about the Home Health Care Program, only 38.6% of physicians surveyed, 50.9% of non-medical personnel, and 35.7% of patients surveyed had heard about the program. In view of above findings, the following measures are deemed prerequisite for an effective implementation of Home Health Care Program. 1. The fee for home health care to be included in the public health insurance. 2. Clearly define the types and scope of services to be offered in the Home Health Care Program. 3. Develop special programs for training nurses who will be assigned to the Home Health Care Program. 4. Train those nurses by consigning them at hospitals and educational institutions. 5. Government conducts publicity campaign toward the public and the hospitals so that the hospitals support the program and patients take advantage of them. 6. Systematic and effective publicity and educational programs for home heath care must be developed and exercises for the people of medical professions in hospitals as well as patients and their families. 7. Establish and operate pilot projects for home health care, to evaluate and refine their programs.

  • PDF

Analysis of Georeferencing Accuracy in 3D Building Modeling Using CAD Plans (CAD 도면을 활용한 3차원 건축물 모델링의 Georeferencing 정확도 분석)

  • Kim, Ji-Seon;Yom, Jae-Hong;Lee, Dong-Cheon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.2
    • /
    • pp.117-131
    • /
    • 2007
  • Representation of building internal space is an active research area as the need for more geometrically accurate and visually realistic increases. 3 dimensional representation is common ground of research for disciplines such as computer graphics, architectural design and engineering and Geographic Information System (GIS). In many cases CAD plans are the starting point of reconstruction of 3D building models. The main objectives of building reconstruction in GIS applications are visualization and spatial analysis. Hence, CAD plans need to be preprocessed and edited to adapt to the data models of GIS SW and then georeferenced to enable spatial analysis. This study automated the preprocessing of CAD data using AutoCAD VBA (Visual Basic Application), and the processed data was topologically restructured for further analysis in GIS environment. Accuracy of georeferencing CAD data was also examined by comparing the results of coordinate transformation by using digital maps and GPS measurements as the sources of ground control points. The reconstructed buildings were then applied to visualization and network modeling.

Parcel Boundary Demarcation in Residential Area Using High Resolution Aerial Images (고해상도 항공영상을 이용한 주거지역 필지경계 설정에 관한 연구)

  • Park, Chiyoung;Lee, Jaeone
    • Spatial Information Research
    • /
    • v.23 no.1
    • /
    • pp.59-68
    • /
    • 2015
  • As part of an effort to leap smart cadastre system by doing rearrangement of various mismatches in the land register, the cadastre renovation project is being recently conducted. In response to this demand, this paper proposes an image-based rapid parcel boundary demarcation plan using the high resolution aerial image with a GSD (Ground Sample Distance) of 5cm that matches to real ground boundary situation in residential area. To review the feasibility and accuracy of this proposed methodology, we compared the accuracy of parcel boundary point and parcel area extracted from the digital stereo plotting on the basis of results of cadastral boundary surveying and land register over the selected two test areas. The comparative accuracy result of all boundary points by digital stereo plotting is satisfied with accuracy requirement according to the criteria of the enforcement regulation of cadastral surveying, whereas it exceeded allowable error of ${\pm}0.07m$, more strictly specified in the Special Act on Cadastral Renovation. And about 20% of the total 70 parcels extracted by digital plotting are out of area tolerance in Jecheon study area, and 10% of the total 19 parcels in Suwon study area. The parcels exceeding accuracy limit are mostly due to the occlusion caused by building roof or eaves, and the obstacles such as trees existing on the boundary. Furthermore, an object identification is impossible in image because of vague boundary reference in case of nonexistence of man-made structures or natural features. Therefore, the utilization of boundary identification stickers is recommended as a solution for these types of land parcel.

Calibration of a UAV Based Low Altitude Multi-sensor Photogrammetric System (UAV기반 저고도 멀티센서 사진측량 시스템의 캘리브레이션)

  • Lee, Ji-Hun;Choi, Kyoung-Ah;Lee, Im-Pyeong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.1
    • /
    • pp.31-38
    • /
    • 2012
  • The geo-referencing accuracy of the images acquired by a UAV based multi-sensor system is affected by the accuracy of the mounting parameters involving the relationship between a camera and a GPS/INS system as well as the performance of a GPS/INS system. Therefore, the estimation of the accurate mounting parameters of a multi-sensor system is important. Currently, we are developing a low altitude multi-sensor system based on a UAV, which can monitor target areas in real time for rapid responses for emergency situations such as natural disasters and accidents. In this study, we suggest a system calibration method for the estimation of the mounting parameters of a multi-sensor system like our system. We also generate simulation data with the sensor specifications of our system, and derive an effective flight configuration and the number of ground control points for accurate and efficient system calibration by applying the proposed method to the simulated data. The experimental results indicate that the proposed method can estimate accurate mounting parameters using over five ground control points and flight configuration composed of six strips. In the near future, we plan to estimate mounting parameters of our system using the proposed method and evaluate the geo-referencing accuracy of the acquired sensory data.

암반지하수 저류지 개발 전망

  • 이기철;한정상;부성안;장준영;박종철
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.85-92
    • /
    • 2002
  • When the United Nation classified as Korea is the one of the water deficit country. The consensus was made that the water is the one of the precious national resources. Government increases their R/D budget trying to get more clean water bodies. For instances, 'Sustainable Water Resources Development' project is the one of major title in '21 Century Frontier Research project and there are several small research projects are undergoing by the Ministry of Agriculture and KARICO. However, when the environmental preservation issue has been get more emphasis, construction of the Surface Dam met the blockage from the environmentalists due to the problem of the their water buried area. Since the most fitting site for surface dam had been used in the past, some engineer move their focus on modification of the existing Dam's height to enlarge its capacity or dredging the bottom of the reservoir recently However dredging evoke water quality problem in return by accumulated materials at the bottom. Last year the Dong Gang Dam plan has been canceled by environmental problem in water buried area of the reservoir. With the point of this view, ground water gets more focus for the one of the useful alternative for clean water bodies. Underground dam technique which had widely applied once in the early nineteen eighties by the KARICO and attenuated due to engineering insufficiency. The technique is newly studied with the advanced engineering technique. Still groundwater usage rate in Korea is much lower comparing with the advanced countries and has many rooms to develop. Wells, under ground dam and radial collector wells are typical facilities up to now. There is little application in Korea for the Recharge Dam, which had been widely used in the advanced countries. The Recharge Dam is technique to conjunct surface water and groundwater body together, This technique had developed to increase groundwater recharge at the beginning This research is the result of the study on the possibility of the development of the new technology, Groundwater Reservoir' which was modified from Recharge Dam. Groundwater Reservoir is like a deep artificial lakes trenched in hard rock aquifer to get groundwater. The advantage of the Groundwater Reservoir is followings 1) It can be developed at the plains area, not in the deep valley 2) Huge water body can be developed without dam 3) Small buried area comparing surface water dam makes the least environmental effect. 4) Trenching cost can be substitute by the income of the selling rock debris 5) Outfit of the reservoir can be modified to match with the site prospect 6) Rock debris can be used as constructing materials 7) It can be used as groundwater recharge system when the heavy rains comes 8) The reservoir looks like scenery lake with huge clean water bodies.

  • PDF

A Study on the Orbits and the Ground-based Optical Tracking of a Future Korean Navigation Satellite System (미래 한국형 위성항법시스템의 궤도와 지상기반 광학추적에 대한 연구)

  • Jo, Jung Hyun;Yim, Hong-Suh;Choi, Young-Jun;Choi, Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.7 no.3
    • /
    • pp.121-129
    • /
    • 2012
  • Any development plan of a Korean space-based navigational system has been neither designed nor introduced yet. However, the demand for the development of a domestic regional satellite navigation system can be originated from the outside of market. The growing dependency on satellite navigational systems in Korea eventually requires the retainment and the operation of a domestic navigational satellite system. There is not many choices on the orbit designs and the system design concepts of a regional augmented navigation satellite system or a regional navigation satellite system for the service on the vicinity of the Korean peninsular. Space situational awareness (SSA) has been a rising issue for both national security and more realistic space business in Korea. Also SSA related technologies in Korea is a newly inaugurated area and is necessary to generate a navigation messages and maintain a future Korean navigation satellite system. In this study, the availability of Japanese Quasi Zenith Satellite System (QZSS) expected to be deployed definitely sooner than Korean counter-part is analyzed. The availability of the similar configured system over Korea is investigated with assumed QZSS type orbit. Also, feasible configuration of orbits for domestic navigation satellite system is suggested. And the observability of a ground-based optical tracking system as a secondary tracking capability is analyzed.

A Study on the Criteria for Demarcating Ecological Types of Urban Areas by the Affection of Ecosystems - Case Study in Gangdong-Gu, Seoul - (시가화지역 생태적 유형구분을 위한 관련지표 특성 연구 - 서울시 강동구를 사례로 -)

  • Hong, Suk-Hwan;Lee, Kyong-Jae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.36 no.2
    • /
    • pp.24-31
    • /
    • 2008
  • Studies for demarcation of urban areas by ecological type have been developed, but the demarcation of urban areas by ecological perception is thus far dependent on artificial land use. Therefore, the purpose of this study is to find factors that account for the urban area ecosystems by surveying a variety of ecosystem factors. By land use type, the urban area of Gangdong District, Seoul was defined. Then ecological factors in each polygon were surveyed. Ecological factors are associated with energy use(building coverage ratio, floor area ratio and ground temperature), water circulation(biotope area factors and impermeable pave ratio) and biological diversity(bird appearance index and green area ratio). The correlation between each factor was analyzed. The results indicate that urban ground temperature is divided into three groups(high, middle and low) by the biotope area factor. The bird population is divided into two groups(abundant and scarce) by the green area ratio. Therefore, demarcating the urban areas by ecological type is applicable to the biotope area factor and green area ratio.

Recycle Possibility of the Stone-Dust in Quarry as Subbase Layer Materials of the Road (도로 보조기층재로서 채석장 석분토의 재활용가능성 분석)

  • Kim, Kyeong-Su;Song, Young-Suk
    • The Journal of Engineering Geology
    • /
    • v.17 no.2 s.52
    • /
    • pp.279-287
    • /
    • 2007
  • An ore of stone obtained from quarry lose its about 60% such as the muck and the stone-dust during the process of making the architectural block, the crushed aggregate and so on. A part of the muck is only reutilized for the crushed aggregate as road pavement materials, while the most of the muck in the shape of powder is mixed with water and then it is deposited in a sludge tank. The muck in the shape of powder is called the stone-dust. If the stone-dust is discharged and sprayed, an ecosystem will have terrible damage because the seepage of surface water, the flow of ground water and the movement of air are not occurred smoothly by packing the void of soils. As the Waste Management Law (2003) in Korea, the stone-dust is sorted out the industrial waste and the most of that is dumped in ground. Therefore, the establishments of an efficient recycling plan are necessary through the improvement of engineering properties of the stone-dust. To investigate the possibility of recycle and improvement for the stone-dust, the stone-dust and natural soils are sampled from six quarries in Korea. The various soil tests are performed by use of the mixed soils with the stone-dust content ratio. As the result of various soil tests, the recycle possibility of the stone-dust is analyzed as subbase layer materials of the roads.

Measurement of Dust Concentration in a Mechanically Ventilated Broiler House and Analysis of Dust Generation from Ground Beds (강제환기식 계사의 공기 중 분진 농도 측정 및 바닥재로부터의 분진 발생량 분석)

  • Kwon, Kyeong Seok;Jo, Ye Seul;Lee, In Bok;Ha, Tae Hwan;Hong, Se Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.6
    • /
    • pp.31-43
    • /
    • 2014
  • Confined and mechanically ventilated broiler house has been recently come into wide use to increase productivity and control rearing conditions. However, high dust concentration inside facility can threaten respiratory welfare of farmers and broilers. In Korea, there is no regulation in terms of air quality control inside agricultural facilities and sufficient data is not available. To cope with these, periodic monitoring of inhalable and respirable dust concentration were conducted according to season, broiler's activity and specific events such as shipment work for broilers in mechanically ventilated broiler house. Chamber experiment was also designed to analyze mechanism of dust generation from ground beds according to water contents and surrounding wind environment. Results showed that significant increase of inhalable (p=0.002) and respirable (p=0.03) dust were observed when activity of broilers was high according to entrance of the workers. Even shipment work for matured broilers, high level of dust were observed; inhalable dust was exceeded the threshold limit over maximum 303 % and respirable dust was over maximum 1,550 %, implying that acute respiratory symptoms could be manifested for the workers. From the chamber experiment, critical water contents for interrupting of dust generation were measured; about 45 % for inhalable dust and about 50 % for respirable dust. These results can be a trigger for designing plan of dust control however it still needs consideration of various environmental conditions, hygiene problems, etc.