• Title/Summary/Keyword: Ground motions

Search Result 900, Processing Time 0.021 seconds

A rapid screening method for selection and modification of ground motions for time history analysis

  • Behnamfar, Farhad;Velni, Mehdi Talebi
    • Earthquakes and Structures
    • /
    • v.16 no.1
    • /
    • pp.29-39
    • /
    • 2019
  • A three-step screening process is presented in this article for selection of consistent earthquake records in which number of suitable ground motions is quickly screened and reduced to a handful number. Records that remain at the end of this screening process considerably reduce the dispersion of structural responses. Then, an effective method is presented for spectral matching and modification of the selected records. Dispersion of structural responses is explored using different statistical measures for each scaling procedure. It is shown that the Uniform Design Method, presented in this study for scaling of earthquake records, results in most cases in the least dispersion measure.

Probabilistic analysis of structural pounding considering soil-structure interaction

  • Naeej, Mojtaba;Amiri, Javad Vaseghi
    • Earthquakes and Structures
    • /
    • v.22 no.3
    • /
    • pp.289-304
    • /
    • 2022
  • During strong ground motions, adjacent structures with insufficient separation distances collide with each other causing considerable architectural and structural damage or collapse of the whole structure. Generally, existing design procedures for determining the separation distance between adjacent buildings subjected to structural pounding are based on approximations of the buildings' peak relative displacement. These procedures are based on unknown safety levels. This paper attempts to evaluate the influence of foundation flexibility on the structural seismic response by considering the variability in the system and uncertainties in the ground motion characteristics through comprehensive numerical simulations. Actually, the aim of this study is to evaluate the influence of foundation flexibility on probabilistic evaluation of structural pounding. A Hertz-damp pounding force model has been considered in order to effectively capture impact forces during collisions. In total, 5.25 million time-history analyses were performed over the adopted models using an ensemble of 25 ground motions as seismic input within OpenSees software. The results of the study indicate that the soil-structure interaction significantly influences the pounding-involved responses of adjacent structures during earthquakes and generally increases the pounding probability.

Conditional mean spectrum for Bucharest

  • Vacareanu, Radu;Iancovici, Mihail;Pavel, Florin
    • Earthquakes and Structures
    • /
    • v.7 no.2
    • /
    • pp.141-157
    • /
    • 2014
  • The Conditional Mean Spectrum represents a powerful link between the seismic hazard information and the selection of strong ground motion records at a particular site. The scope of the paper is to apply for the city of Bucharest for the first time the method to obtain the Conditional Mean Spectrum (CMS) presented by Baker (2011) and to select, on the basis of the CMS, a suite of strong ground motions for performing elastic and inelastic dynamic analyses of buildings and structures with fundamental periods of vibration in the vicinity of 1.0 s. The major seismic hazard for Bucharest and for most of Southern and Eastern Romania is dominated by the Vrancea subcrustal seismic source. The ground motion prediction equation developed for subduction-type earthquakes and soil conditions by Youngs et al. (1997) is used for the computation of the Uniform Hazard Spectrum (UHS) and the CMS. The disaggregation of seismic hazard is then performed in order to determine the mean causal values of magnitude and source-to-site distance for a particular spectral ordinate (for a spectral period T = 1.0 s in this study). The spectral period of 1.0 s is considered to be representative for the new stock of residential and office reinforced concrete (RC) buildings in Bucharest. The differences between the Uniform Hazard Spectrum (UHS) and the Conditional Mean Spectrum (CMS) are discussed taking into account the scarcity of ground motions recorded in the region of Bucharest and the frequency content characteristics of the recorded data. Moreover, a record selection based on the criteria proposed by Baker and Cornell (2006) and Baker (2011) is performed using a dataset consisting of strong ground motions recorded during seven Vrancea seismic events.

Seismic Performance Evaluation of Piping System Crossing the Isolation Interface in Seismically Isolated NPP (면진 원전 면진-비면진구간 연결 배관의 내진성능 평가)

  • Hahm, Daegi;Park, Junhee;Choi, In-Kil
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.141-150
    • /
    • 2014
  • A methodology to evaluate the seismic performance of interface piping systems that cross the isolation interface in the seismically isolated nuclear power plant (NPP) was developed. The developed methodology was applied to the safety-related interface piping system to demonstrate the seismic performance of the target piping system. Not only the seismic performance for the design level earthquakes but also the performance for the beyond design level earthquakes were evaluated. Two artificial seismic ground input motions which were matched to the design response spectra and two historical earthquake ground motions were used for the seismic analysis of piping system. The preliminary performance evaluation results show that the excessive relative displacements can occur in the seismically isolated piping system. If the input ground motion contained relatively high energy in the low frequency region, we could find that the stress response of the piping system exceed the allowable stress level even though the intensity of the input ground motion is equal to the design level earthquake. The structural responses and seismic performances of piping system were varied sensitively with respect to the intensities and frequency contents of input ground motions. Therefore, for the application of isolation system to NPPs and the verification of the safety of piping system, the seismic performance of the piping system subjected to the earthquake at the target NPP site should be evaluated firstly.

Seismic responses of base-isolated nuclear power plant structures considering spatially varying ground motions

  • Sayed, Mohamed A.;Go, Sunghyuk;Cho, Sung Gook;Kim, Dookie
    • Structural Engineering and Mechanics
    • /
    • v.54 no.1
    • /
    • pp.169-188
    • /
    • 2015
  • This study presents the effects of the spatial variation of ground motions in a hard rock site on the seismic responses of a base-isolated nuclear power plant (BI-NPP). Three structural models were studied for the BI-NPP supported by different number of lead rubber bearing (LRB) base isolators with different base mat dimensions. The seismic responses of the BI-NPP were analyzed and investigated under the uniform and spatial varying excitation of El Centro ground motion. In addition, the rotational degrees of freedom (DOFs) of the base mat nodes were taken to consider the flexural behavior of the base mat on the seismic responses under both uniform and spatial varying excitation. Finally, the seismic response results for all the analysis cases of the BI-NPP were investigated in terms of the vibration periods and mode shapes, lateral displacements, and base shear forces. The analysis results indicate that: (1) considering the flexural behavior of the base mat has a negligible effect on the lateral displacements of base isolators regardless of the number of the isolators or the type of excitation used; (2) considering the spatial variation of ground motions has a substantial influence on the lateral displacements of base isolators and the NPP stick model; (3) the ground motion spatial variation effect is more prominent on lateral displacements than base shear forces, particularly with increasing numbers of base isolators and neglecting flexural behavior of the base mat.

The Study on the Parameters to Represent the Characteristics of the Observed Ground motions (국내 관측 지진파형을 이용한 지진파형 영향인자에 관한 연구)

  • 김준경
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.44-48
    • /
    • 2000
  • Several parameters to represent the characteristics of the observed at the domestic networks from several earthquakes occurred in the Korean Peninsula. Parameters to fit most the multiple Fourier amplitude spectra of the observed accelerations are estimated. This study adopts the stochastic ground motion model referred to the BLWN mode in which the energy is distributed randomly over the duration of the source and which has proven to be very effective in modeling a wide range of ground motion observations. The stochastic ground motion model employed here uses an omega-squared ({{{{ omega ^2 }}) Brune source model with a single corner frequency and a constant stress drop,. The {{{{ omega ^2 }} source model has become a seismological standard because of its simplicity an ability to predict spectral amplitudes and shapes over an extremely broad ranges of magnitudes distances and from the inversion show very unstable based on the fact of high values of mean/median. These results may imply that more observed data and more precise site classification including accurate preparation analysis of data such as more accurate scaling from counts to kine are needed for more stable are effective inversion of Fourier amplitude spectrum of the observed ground motions.

  • PDF

The Duration and H/V ratio of the Ground Motion in Southern Korea (남한 지진의 지속시간과 H/V 비율)

  • 최호선;박창업;조남대
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.42-50
    • /
    • 2002
  • The duration and H/V ratio(the amplitude ratio of the horizontal to vertical components) of ground motions caused by earthquakes in southern Korea are analyzed. Total 329 seismograms of horizontal component recorded at hypocentral distances of 10 to 350 km from 27 earthquakes with local magnitude 2 to 4 are used for the analysis. Simplified relation between the duration of ground motion( $T_{d}$) and the ratio($\chi$) of Arias intensity( $I_{A}$) and squared maximum acceleration($\alpha$$_{max}$$^{2}$) is determined to be $T_{d}$ = 3.423$\chi$$^2$+ 8.200$\chi$ + 0.029, which is useful for the estimation of the duration in southern Korea. There are three distinct distance ranges with different linear variations of the duration in hypocentral distance. They are distance intervals of 10~80km, 80~140km, and the distance greater than 140km. The duration in southern Korea shows clear proportionality to the local magnitude at magnitudes greater than 3.1. The value 1.37 of the H/V ratio obtained in southern Korea is similar to the value 1.4 of ENA(Eastern North America). The H/V ratio in southern Korea increases in the frequency range from 0.3 to 10Hz. The duration and H/V ratio of ground motions derived in this study could be used in the stochastic simulation of strong ground motion.ion.n.n.

  • PDF

Earthquake Response Analysis for Seismic Isolation System of Single Layer Lattice Domes With 300m Span (300m 단층 래티스 돔의 면진 장치에 대한 지진 반응 해석)

  • Park, Kang-Geun;Chung, Mi-Ja;Lee, Dong-Woo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.3
    • /
    • pp.105-116
    • /
    • 2018
  • The objective of this study is to investigate the response reducing effect of a seismic isolation system installed between 300m dome and supports under both horizontal and vertical seismic ground motion. The time history analysis is performed to investigate the dynamic behavior of single layer lattice domes with and without a lead rubber bearing seismic isolation system. In order to ensure the seismic performance of lattice domes against strong earthquakes, it is important to investigate the mechanical characteristics of dynamic response. Horizontal and vertical seismic ground motions cause a large asymmetric vertical response of large span domes. One of the most effective methods to reduce the dynamic response is to install a seismic isolation system for observing seismic ground motion at the base of the dome. This paper discusses the dynamic response characteristics of 300m single layer lattice domes supported on a lead rubber seismic isolation device under horizontal and vertical seismic ground motions.

Dynamic Behavior Analyses of Bridges under Seismic Excitations in 2-Dimensional Directions (이차원 지진성분을 고려한 교량시스템의 지진거동분석)

  • 김상효
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.333-340
    • /
    • 2000
  • Dynamic response behaviors of a bridge are examined under seismic excitations in the 2-dimensional directions are examined. A three-dimensional mechanical model is utilized and the corresponding equations of motions are derived to consider the two directional bridge motions due to the randomness residing in the excitation directions. The arbitrary 2-dimensional directions are simulated by applying two independent excitations in the two directions: main direction(longitudinal) ; the additive direction normal to the main (transverse). The rotational superstructure motions due to the spacial motions of the bridge are considered by admitting the deformation of the bearings at supports. The relative displacement to the ground motions and the relative distance between adjacent oscillators are found to be increased by a considerable amount in the case when considering arbitrary directional seismic excitations. It is also found that the piermotions show more complicated behaviors due to the arbitrary seismic directions.

  • PDF

Seismic Response Analysis of a Floating Bridge with Discrete Pontoons (이산폰툰형 부유식교량의 지진응답해석)

  • Kwon, Jang-Sup
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.2 s.42
    • /
    • pp.47-58
    • /
    • 2005
  • Dynamic response analysis in time dimain is conducted for floating bridges with discrete pontoons subject to spatial variation of ground motions. The Spatial variation of ground motions is considered with the coherency function model which represents wave passage, incoherence and local site effects. The superstructure of the bridge is represented by space frame and elastic catenary cable elements, the abutment us modelde with the spring element of FHWA guideline for considering soil structure interaction and the concept of retardation function is utilized to consider the frequency dependency of the hydrodynamic coefficients which are obtainde by boundary element method. multiple support excitations considering the spatial variation. The noticeable amplification of the response can be shown when the spatial variation of ground motions is incorporated in the anallysis of floating bridges.