• 제목/요약/키워드: Ground level concentration

검색결과 171건 처리시간 0.023초

Investigations on aerosols transport over micro- and macro-scale settings of West Africa

  • Emetere, Moses Eterigho
    • Environmental Engineering Research
    • /
    • 제22권1호
    • /
    • pp.75-86
    • /
    • 2017
  • The aerosol content dynamics in a virtual system were investigated. The outcome was extended to monitor the mean concentration diffusion of aerosols in a predefined macro and micro scale. The data set used were wind data set from the automatic weather station; satellite data set from Total Ozone Mapping Spectrometer aerosol index and multi-angle imaging spectroradiometer; ground data set from Aerosol robotic network. The maximum speed of the macro scale (West Africa) was less than 4.4 m/s. This low speed enables the pollutants to acquire maximum range of about 15 km. The heterogeneous nature of aerosols layer in the West African atmosphere creates strange transport pattern caused by multiple refractivity. It is believed that the multiple refractive concepts inhibit aerosol optical depth data retrieval. It was also discovered that the build-up of the purported strange transport pattern with time has enormous potential to influence higher degrees of climatic change in the long term. Even when the African Easterly Jet drives the aerosols layer at about 10 m/s, the interacting layers of aerosols are compelled to mitigate its speed to about 4.2 m/s (macro scale level) and boost its speed to 30 m/s on the micro scale level. Mean concentration diffusion of aerosols was higher in the micro scale than the macro scale level. The minimum aerosol content dynamics for non-decaying, logarithmic decay and exponential decay particulates dispersion is given as 4, 1.4 and 0 respectively.

복잡지형의 대기확산모델 비교 (Comparison of Complex Terrain Dispersion Models)

  • 김영성;오현선
    • 한국대기환경학회지
    • /
    • 제14권2호
    • /
    • pp.81-94
    • /
    • 1998
  • Six complex terrain dispersion models recommended by the U. S. Environmental Protection Agency were investigated using a hypothetical case in which a plume approaches complex terrain. The six models considered were Valley, CTSCREEN, COMPLEX 1, SHORTZ, RTDM, and CTDMPLUS, the latter four being closely studied. Highest concentrations were predicted for 48 receptors and plume behaviors were compared for stable and unstable meteorological conditions. Under stable conditions, ground-level concentrations were determined by the height of the plume centerline above the terrain. The concentrations estimated by SHORTZ and COMPLEX I were higher than those estimated by CTSCREEN, with CTDMPLUS predicting the lowest concentrations. In particular, the height of the lift midpoint, as well as the co.nterline of the plume, are important in the model calculation of CTDMPLUS. Under unstable conditions, the vertical dispersion plays a key role in determining ground -level concentrations. For this case, concentrations predicted by CTDMPLUS were the 'highest, whereas those predicted by SHORTZ were the lowest. Concentration distributions predicted by CTDMPLUS are quite similar to typical Gaussian distributions even on complex terrain, except for a slight shift of the plume centerline due to the of(tract of the geostrophic wind. In addition,24-hour average concentrations were estimated for comparison with results from the Valley model. Among the four models studied closely, CTDMPLUS predicted the lowest 24-hour average concentrations, but the concentrations estimated by Valley were lower than those estimated by CTDMPLUS.

  • PDF

지하수와 지표수에서의 라돈 및 우라늄의 실태 조사 (The Study of Radon Activity and Uranium Concentration of Ground Water and Surface Water)

  • 오영미;이종복;신경진;김학철;이재희;황상철;정상기;이상태
    • 한국물환경학회지
    • /
    • 제23권2호
    • /
    • pp.201-205
    • /
    • 2007
  • This paper reports the amount of $^{222}Rn$ and $^{238}U$ in 18 sites of ground water and 30 sites of surface water. The instrument used to count $^{222}Rn$ activity was the liquid scintillation counter (LSC) which could resolute ${\alpha}$ and ${\beta}$ radiations. And $^{238}U$ was analyzed by the inductively coupled plasma (ICP). Radon and Uranium were not detected in raw and treated water which were sampled in a water treatment plant. However, radon ($^{222}Rn$) was high concentration in ground water from Jeon-la, Gang-won. So was uranium ($^{238}U$) in case of ground water from Gang-won, Choong-chung. Radon ($^{222}Rn$) activities were detected less than 15 pCi/L at 5 sampling points, 15~300 pCi/L at 7 sampling points, 300~4000 pCi/L at 6 sampling points. However, Radon ($^{222}Rn$) activities of all ground water samples were less than 4,000 pCi/L, which was bellow American Alternative Maximum Contamination Level (AMCL). Uranium ($^{238}U$) concentrations were less than $0.1{\mu}g/L$ at 5 sampling points, from $0.1{\mu}g/L$ to $20{\mu}g/L$ at 13 sampling points. Uranium was not detected in about 30% of the whole samples, but the concentration ranged from relatively low to high concentrations depending on the sampling point. The minimum detectable activity (MDA) of radon was 15 pCi/L. and the detection limit of uranium was $0.1{\mu}g/L$.

Vertical Distribution and Potential Risk of Particulate Polycyclic Aromatic Hydrocarbons in High Buildings of Bangkok, Thailand

  • Pongpiachan, Siwatt
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권3호
    • /
    • pp.1865-1877
    • /
    • 2013
  • Vertical variations of polycyclic aromatic hydrocarbon (PAH) concentrations in $PM_{10}$ were investigated in order to assess the factors controlling their behavior in the urban atmosphere of Bangkok City, Thailand. Air samples were collected every three hours for three days at three different levels at Bai-Yok Suit Hotel (site-1 and site-2) and Bai-Yok Sky Hotel (site-3) in February $18^{th}-21^{st}$, 2008. The B[a]P concentration showed a value 0.54 fold, lower than the United Kingdom Expert Panel on Air Quality Standard (UK-EPAQS; i.e. 250 pg $m^{-3}$) at the top level. In contrast, the B[a]P concentrations exhibited, at the ground and middle level, values 1.50 and 1.43 times higher than the UK-EPAQS standard respectively. PAHs displayed a diurnal variation with maximums at night time because of the traffic rush hour coupled with lower nocturnal mixing layer, and the decreased wind speed, which consequently stabilized nocturnal boundary layer and thus enhanced the PAH contents around midnight. By applying Nielsen's technique, the estimated traffic contributions at Site-3 were higher than those of Site-1: about 10% and 22% for Method 1 and Method 2 respectively. These results reflect the more complicated emission sources of PAHs at ground level in comparison with those of higher altitudes. The average values of incremental individual lifetime cancer risk (ILCR) for all sampling sites fell within the range of $10^{-7}-10^{-6}$, being close to the acceptable risk level ($10^{-6}$) but much lower than the priority risk level ($10^{-4}$).

Estimation of 222Rn Concentration in the Lower Troposphere during Precipitation Using Wet Scavenging Model for its Decay Products

  • Takeyasu, Masanori;Takeishi, Minoru
    • Asian Journal of Atmospheric Environment
    • /
    • 제4권1호
    • /
    • pp.20-25
    • /
    • 2010
  • The gaseous $^{222}Rn$ concentration at the level of clouds was estimated by using the wet scavenging model of its decay products with the observed data of environmental radiation at the ground. And the origin of the $^{222}Rn$ was also discussed. The estimation was done for a precipitation event on Dec. 26-27, 2003, when a large increase of the radiation was observed in Tokai-mura in Ibaraki, Japan. From a backward trajectory analysis, the origin of $^{222}Rn$ atoms for that event was traced back to the northeastern part of China, and it was expected that the large amount of $^{222}Rn$ emitted in the northeastern part of China was transported to Tokai-mura by the Eurasian continental air mass.

중립 대기 상태에서 이상 난류유동에 관한 수치적 연구 (A Numerical Analysis for Two-phase Turbulent Flow in the Neutral Atmosphere)

  • 강승규;윤준용;이도형
    • 대한기계학회논문집B
    • /
    • 제26권6호
    • /
    • pp.772-778
    • /
    • 2002
  • A numerical analysis of turbulent gas-particle two-phase flow is performed in conjunction with the experiments of Fackrell & Robins and Raupach & Legg that considered ground-level source and/or elevated source flat plate flow. K-$\omega$ turbulence model is used in order to analyze fully turbulent flow field and the concentration equation with settling velocity is adopted for the concentration field. The model of Einstein and Chien is applied that couples the velocity field and the concentration field. Turbulent eddy viscosity is re-evaluated in this model. The present numerical results have good agreement between the simulation and the experimental data for the mean flow velocities and particle concentrations. While the previous study shows about 27% error in the vicinity of the source of particle concentration, the .present study allows about 14% error. A new turbulent gas-particle flow model developed by this study is able to cut down error by 13% at a near source.

사무실 내 라돈 농도에 관한 연구 (A Study on the Radon Concentration in the Office)

  • 최현우;김치년;원종욱;김홍관;노재훈
    • 한국산업보건학회지
    • /
    • 제26권3호
    • /
    • pp.334-341
    • /
    • 2016
  • Objectives: This study is aimed at examining radon exposure in offices and the factors that can influence the concentrations. Methods: Indoor radon concentrations in a total of 30 places were measured from January 18 to 21, 2016, targeting six buildings in Seoul with different completion years. The measurement was conducted according to the radon measurement guidelines for indoor air suggested by the Ministry of Environment. Results: As a result of comparing each average concentration, underground area concentration was $42.850{\pm}22.501Bq/m^3$, and that of the ground floors was $27.850{\pm}12.232Bq/m^3$, which was lower than the concentration in the underground areas and statistically significant (p=0.045). As a result of comparing the concentration according to whether or not outside air entered, the average concentration for ventilated areas was $24.876{\pm}11.833Bq/m^3$, and the average concentration for enclosed areas was $47.892{\pm}19.375Bq/m^3$. The concentration in ventilated areas was lower at a statistically significant level (p=0.001). Finally, as a result of the multiple regression analysis for evaluating the factors influencing radon concentration, only ventilation was significant (p=0.007). Conclusions: As a result of measuring radon in office buildings, there was no place that exceeding the recommended standard of the US EPA, but the concentration in poorly ventilated areas was measured to be high. An effort to manage radon concentration and reduce it through the improvement of ventilation systems, repeated measurement is necessary in the future.

Assessment of Air Quality Impact Associated with Improving Atmospheric Emission Inventories of Mobile and Biogenic Sources

  • Shin, Tae-joo
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제4권1호
    • /
    • pp.11-23
    • /
    • 2000
  • Photochemical air quality models are essential tools in predicting future air quality and assessing air pollution control strategies. To evaluate air quality using a photochemical air quality model, emission inventories are important inputs to these models. Since most emission inventories are provided at a county-level, these emission inventories need to be geographically allocated to the computational grid cells of the model prior to running the model. The conventional method for the spatial allocation of these emissions uses "spatial surrogate indicators", such as population for mobile source emissions and county area for biogenic source emissions. In order to examine the applicability of such approximations, more detailed spatial surrogate indicators were developed using Geographic Information System(GIS) tools to improve the spatial allocation of mobile and boigenic source emissions, The proposed spatial surrogate indicators appear to be more appropriate than conventional spatial surrogate indicators in allocating mobile and biogenic source emissions. However, they did not provide a substantial improvement in predicting ground-level ozone(O3) concentrations. As for the carbon monoxide(CO) concentration predictions, certain differences between the conventional and new spatial allocation methods were found, yet a detailed model performance evaluation was prevented due to a lack of sufficient observed data. The use of the developed spatial surrogate indicators led to higher O3 and CO concentration estimates in the biogenic source emission allocation than in the mobile source emission allocation.llocation.

  • PDF

Hydrolytic Stability of Cured Urea-Melamine-Formaldehyde Resins Depending on Hydrolysis Conditions and Hardener Types

  • Park, Byung-Dae;Lee, Sang-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권5호
    • /
    • pp.672-681
    • /
    • 2015
  • As a part of abating the formaldehyde emission of amino resin-bonded wood-based composite panels, this study was conducted to investigate hydrolytic stability of urea-melamine-formaldehyde (UMF) resin depending on various hydrolysis conditions and hardener types. Commercial UMF resin was cured and ground into a powdered form, and then hydrolyzed with hydrochloric acid. After the acid hydrolysis, the concentration of liberated formaldehyde in the hydrolyzed solution and mass loss of the cured UMF resins were determined to compare their hydrolytic stability. The hydrolysis of cured UMF resin increased with an increase in the acid concentration, time, and temperature and with a decrease in the smaller particle size. An optimum hydrolysis condition for the cured UMF resins was determined as $50^{\circ}C$, 90 minutes, 1.0 M hydrochloric acid and $250{\mu}m$ particle size. Hydrolysis of the UMF resin cured with different hardener types showed different degrees of the hydrolytic stability of cured UMF resins with a descending order of aluminum sulfate, ammonium chloride, and ammonium sulfate. The hydrolytic stability also decreased as the addition level of ammonium chloride increased. These results indicated that hardener types and level also had an impact on the hydrolytic stability of cured UMF resins.

지역 허브급 버티포트의 설계 및 운영 연구 (A Research on the Design and Operation of Regional Hub-Level Vertiport)

  • 이동욱;이동규;박성식
    • 한국항공운항학회지
    • /
    • 제32권1호
    • /
    • pp.79-90
    • /
    • 2024
  • UAM is emerging due to the deepening population concentration in the metropolitan area and the problem of congested ground transportation in urban areas. Accordingly, along with research on eVTOL aircraft for UAM services, interest in vertiport, the interest in vertiports, the infrastructure that allows eVTOLs to take off and land, is also increasing. However, behind the concentration of population in the metropolitan area, aphenomenon of local extinction is occurring in conjunction with the aging population. AAM, which moves quickly through 3D space, can be an effective SOC facility in times of local extinction crisis. In this paper, we introduce a design plan from the perspective of a complex transper center for a regional hub-level vertiport that can connect with local high-speed rail and utilize local airports in compliance with the vertiport design guidelines issued by FAA(Federal Aviation Administration) and EASA(European union Aviation Safety Agency). We would like to present Vertiport's future operation plan.