• 제목/요약/키워드: Ground impedance

검색결과 509건 처리시간 0.024초

새로운 구조의 동축 테스트 소켓을 이용한 미세 피치 프로브 핀의 신호 전달 특성 개선 (Improvement of Signal Transfer Characteristics of Fine Pitch Probe Pin Using Coaxial Test Socket with New Structure)

  • 서정준;김문정
    • 반도체디스플레이기술학회지
    • /
    • 제23권1호
    • /
    • pp.97-103
    • /
    • 2024
  • In this paper, the difference between the S-parameter and the characteristic impedance according to the structural change of the fine pitch coaxial socket was analyzed. A pitch of the probe pin was applied to 0.20mm, and ground pins of different conditions were placed on each of the five signal pins. Insertion loss and reflection loss were analyzed for the coaxial socket of normal structure and the two sockets of the proposed structure. In addition, the difference in characteristic impedance was analyzed using time domain reflectometry. Through the analysis, it was confirmed that the characteristic impedance was improved applying the new structures of the socket at the same pitch

  • PDF

MATLAB 프로그램을 이용한 배전계통에 사용되는 동봉 접지전극의 과도 접지임피던스 특성 분석 (Transient Grounding Impedance Characteristic Analysis of a Copper Rod-type Grounding Electrode Used for Electric Distribution Systems Using MATLAB Program)

  • 김경철;오경훈;이규진;심건보;최종기
    • 조명전기설비학회논문지
    • /
    • 제23권9호
    • /
    • pp.40-46
    • /
    • 2009
  • 비록 접지저항은 접지전극의 접지성능을 좌우하는 지수이기는 하지만, 과도상태에서는 접지 성능을 반영하지 못한다. 동봉은 배전계통에서 가장 많이 쓰이는 접지전극이다. 본 논문에서는 동봉의 접지 임피던스를 주파수 60[Hz]에서 100[kHz] 범위까지 측정하여 등가 접지임피던스 모델을 구하였다. 뇌격서지가 유입되었을 때 MATLAB 프로그램으로 과도접지임피던스의 수치와 파형을 시뮬레이션하였다.

Critical Length Estimation of Counterpoise Subjected to Lightning Stroke Currents

  • Lee, Bok-Hee;Yoo, Yang-Woo;Kim, Jong-Ho
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.106-113
    • /
    • 2011
  • The conventional grounding impedance of a counterpoise is calculated as a function of the length of the counterpoise by use of the distributed parameter circuit model with an application of the EMTP(Electromagnetic Transient Program). The adequacy of the distributed parameter circuit model is examined and verified by comparison of the simulated and the measured results. The conventional grounding impedance of the counterpoise is analyzed for the first short stroke and subsequent short stroke currents. As a result, the simulated results show that the minimum conventional grounding impedance gives at a specified length of the counterpoise. The shorter the time taken to reach the peak of injected currents, the shorter the length of the counterpoise having the minimum conventional grounding impedance. We also present the critical lengths of the counterpoise for short stroke currents as a function of soil resistivity. Based on these results, it is necessary to compute the length of the counterpoise in a specified soil resistivity which satisfies both the low conventional grounding impedance requirement whilst also providing a suitable ground resistance in order to obtain an economical design and installation of the counterpoise.

해상 풍력발전단지에서 뇌격 시 서지어레스터 열화로 인한 연계 고장 분석 (A Study on the Consecutive Failure Due to Deterioration in Surge Arresters of the Offshore Wind Farm)

  • 김진혁;김규호;이재균;우정욱
    • 전기학회논문지
    • /
    • 제67권10호
    • /
    • pp.1265-1270
    • /
    • 2018
  • One of the ways to improve the stability of power facilities used in power systems is to use power surge arresters and to protect against transient overvoltages and surges in normal operation. Also it is important to reduce the impact of lightning strikes because lightning can create overvoltage in the grid of the wind turbine and affect power quality. So This paper analyzes the effects of overvoltage and adjacent turbines due to single strike and multi strike to ground impedance changes when the surge arrester is deteriorated in a wind power farm.

디지털 거리계전기의 Zone 설정에 관한 연구 (A Study on the Zone Setting of Digital Distance Relay)

  • 이재규;정창호;정병태;안복신;김석일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.946-948
    • /
    • 1998
  • The distance relay is very important for transmission line protection. A quadrilateral zone shape is used mainly for a modern digital distance relay. The shape of quadrilateral is vendor specific. At the stage of design, the shape is determined considering all possible types of faults and diverse configurations of system. Also this type relay must be designed to avoid the operation by a sound phase at single-Phase-to-ground fault, by a sound phase at two-phase-to-ground fault. The effect of a source impedance and a load impedance is another important factor to design. In this paper, a reliable zone shape which is appropriate for the KEPCO's transmission system is provided.

  • PDF

정보화 건측물을 위한 접지감시시스템 개발 (Development of the grounding monitoring system for intelligent buildings)

  • 조성철;이태형;엄주홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.196-197
    • /
    • 2006
  • An effective method is described for monitoring the ground impedance of intelligent building and power system. Most of grounding system of buildings are interconnected to extensive grounding network of power line, signal and control line, telecommunication line, and etc. Therefore, the residual voltages of power frequency and its harmonics may have an significant influence on the accurate measurement of ground impedance. For eliminating the influence of residual voltage, we developed a test power source for generating the 110[Hz] square wave and used digital filtering method in this research.

  • PDF

측정선의 상호유도작용이 접지임피던스의 측정에 미치는 영향 (Effect of Mutual Coupling Between Test Leads on Ground Impedance Measurement)

  • 이복희;엄주홍;조성철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.71-74
    • /
    • 2003
  • Fall-of-potential method is used usually to measure the ground impedance of large scale grounding system exactly. Because the interlinked magnetic flux between closed loops to inject test current and to measure potential rise is existed in E-P-C straight line arrangement, mutual(or inductive) coupling influences greatly on the measurement correctness. Measurement errors produced from inductive coupling could be reduced by the arrangement methods of auxiliary electrodes. Right angle or P-E-C order arrangement methods were effective to reduce the inductive coupling and the decrease degree of measurement error was analysed as quantitative through an experiment.

  • PDF

Enhancement in Isolation among Collinearly Placed Microstrip Patch Antenna Arrays

  • Irfan Ali, Tunio;Hernan, Dellamaggiora;Umair, Saeed;Ayaz Ahmed, Hoshu;Ghulam, Hussain
    • International Journal of Computer Science & Network Security
    • /
    • 제23권1호
    • /
    • pp.120-124
    • /
    • 2023
  • Strong surface waves among collinearly arranged patch antenna arrays pose unwanted inter element coupling particularly when high permittivity dielectric materials are used. In order to avert those waves, a novel Defected Ground Structure (DGS) is carved out systematically between two E-plane patch antenna elements. The introduced low profile μ shaped structure consequently improves impedance bandwidth and reflection coefficient by suppressing surface waves considerably. Parametric simulation results are analyzed and discussed.

Design and analysis of highly selective ultrawide stopband lowpass filter using lumped and distributed equivalent circuit models

  • Pankaj Singh Tomar;Manoj Singh Parihar
    • ETRI Journal
    • /
    • 제46권4호
    • /
    • pp.716-726
    • /
    • 2024
  • An ultrawide stopband lowpass filter is reported using three stepped impedance resonators with high selectivity. The filter extends the stopband frequency range and attenuation, and two quarter-wave open stubs and three circular ground slots are introduced. The lumped and distributed equivalent models are derived and analyzed. The corresponding results are validated experimentally in a fabricated prototype. The prototype lowpass filter has a 3 dB cutoff frequency (fc) of 2.9 GHz, and the stopband is extended up to 35 GHz (12.07fc), with an attenuation level better than 20 dB throughout. The passband-to-stopband transition (3 dB-20 dB) bandwidth is 0.18 GHz, and the roll-off factor is 135 dB/GHz at 30 dB. The insertion loss is 0.3 dB at 1.6 GHz. The normalized circuit size of the proposed filter with respect to the guided wavelength is 0.04.

Modified Carson's Method를 이용한 전차선로의 Impedance 계산 (Impedance Calculation for Electric Railway System using modified Carson's Method)

  • 이춘배;김왕곤;이종우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1403-1405
    • /
    • 2004
  • The method proposed by Carson contains indefinite complex integral which simulates earth return current. Although the Carson solution is proposed with power series, the solution is limited and valid at special range of frequency. We proposed a simplified Carson solution by modelling earth current path analytical method using ground transmission line return current. In this paper, we studied on trying to find the equivalent distance for earth current return path.

  • PDF