• 제목/요약/키워드: Ground heat source

검색결과 310건 처리시간 0.025초

단독주택 건물 그린리모델링에 따른 건물 에너지 성능과 운전비용 절감 효과 평가 (Energy Performance and Operating Cost Assessment for Implementing Green Remodeling Technologies in a Detached House)

  • 손병후;이수인;강재식
    • 한국지열·수열에너지학회논문집
    • /
    • 제19권4호
    • /
    • pp.27-38
    • /
    • 2023
  • The Government the Republic of Korea is showing a lot of interest in net zero-energy buildings (NZEBs) to reduce energy consumption of buildings and to promote green growth policy in construction sector. The application of building passive technologies and renewable energies is essential to achieving NZEBs. Green remodeling reinforced the insulation of the exterior walls and roofs of the buildings and replaced high-efficiency windows and doors. In this study, the energy performance before and after green remodeling applied in a detached house was comparatively analyzed for baseline scenario and three different ones, ALT 1, ALT 2 and ALT 3. A building modeling and simulation software (DesignBuilder V7.0) with EnergyPlus (V9.4) calculation engine was used to calculate the energy demand and energy consumption for each scenario. Based on the calculation results of the building's energy demand for baseline, it was determined that the target building required more heating energy than cooling energy. The simulation results also showed that the implementation of building envelope performance improvement technologies (ALT 1) could notably decrease the heating energy consumption of the building. After the remodeling (ALT 1), the source energy consumption per unit floor area was assessed to be reduced by 65.2%, compared to prior remodeling of 338.7 kWh/m2 -y. Meanwhile, ALT 2 can achieve energy savings of 67.7% and ALT 3 can achieve savings of 73.1%. Following completion of the remodeling project, actual construction costs, and on-site measurements and verification results will be gathered and compared with the simulation results. Additionally, economic analysis including construction costs and payback period will be conducted using actual site data.

단독주택용 태양열/지열 융복합시스템의 태양열 급탕성능 평가 (An Evaluation of the Solar Thermal Performance of the Solar/Geo Thermal Hybrid Hot Water System for a Detached House)

  • 백남춘;한승현;이왕제;신우철
    • 설비공학논문집
    • /
    • 제27권11호
    • /
    • pp.581-586
    • /
    • 2015
  • In this study, an analysis was performed on the performance of the solar water heating system with geo-thermal heat pump for a detached house. This system has a flat plate solar collector ($8\;m^2$) and a 3 RT heat pump. The heat pump acts as an auxiliary heater of the solar water heating system. These systems were installed at four individual houses with the same area of $100\;m^2$. The monitoring results for one year are as follows. (1) The average daily operating time of the solar system appeared to be 313 minutes in spring (intermediate season), and 135 minutes and 76 minutes in winter and summer respectively. The reason for the short operating time in summer is the high storage temperature due to low water heating load. The high storage temperature is caused by a decrease in collecting efficiency as well as by overheating. (2) The geothermal heat pump as an auxiliary heater mainly operates on days of poor insolation during the winter season. (3) Despite controlling for total house area, hot water consumption varies greatly according to the number of people in the family, hot water usage habits, etc. (4) The yearly solar fraction was 69.8 to 91.5 percent, which exceeds the maximum value of 80% as recommended by ASHRAE. So the solar collector area of $8\;m^2$ appeared to be somewhat greater for the house with an area of $100\;m^2$. (5) The observed annual efficiency of solar systems was relatively low at 13.5 to 23.6%, which was analyzed to be due to the decrease in thermal efficiency and the overheating caused by a high solar fraction.

파프리카 재배 벤로형 유리온실에서 난방에너지 절감 패키지 기술 적용효과 (Application Effect of Heating Energy Saving Package on Venlo Type Glasshouse of Paprika Cultivation)

  • 권진경;전종길;김승희;김형권
    • 생물환경조절학회지
    • /
    • 제25권4호
    • /
    • pp.225-231
    • /
    • 2016
  • 본 연구에서는 유리온실 경영비 절감을 위한 고효율 난방기술을 개발하기 위하여 지하수열원 히트펌프, 알루미늄 다겹보온커튼, 근권부 국소난방장치를 조합한 난방 패키지 모델을 구성하고 파프리카 재배 벤로형 유리온실에 적용 시험을 수행하였다. 적용효과 분석을 위하여 관행 경유온수보일러와 일반 보온커튼을 설치한 대조구 온실과 비교시험을 통해 온실환경, 난방비용, 작물생육 등을 검토하였다. 알루미늄 다겹보온커튼과 일반 부직포 보온커튼을 설치한 온실에 대한 무가온 조건에서의 야간온도 비교시험에서 알루미늄 다겹보온커튼 설치 온실의 온도가 일반 부직포 보온커튼 설치 온실에 비해 평균 $2.2^{\circ}C$ 더 높게 유지됨을 확인하였다. 또한 근권부 국소 난방장치를 설치한 온실에서 미설치 온실에 비해 야간 난방 중의 베드내부 근권온도가 $4.7^{\circ}C$ 더 높게 유지됨을 확인하였다. 난방패키지를 구성하는 지하수열원 히트펌프의 난방성능을 분석한 결과 지하수를 직접 열원으로 이용하는 시스템 특성상 난방성능계수는 평균 3.7로 비교적 높게 나타났다. 난방패키지를 적용한 처리구 온실과 관행 난방의 대조구 온실에 대하여 연료소비량을 계측한 결과 10a($1,000m^2$)당 대조구 온실은 경유 14,071L, 전력 364kWh를 소비하였고, 처리구는 전력 35,082kWh를 소비하여 난방비용 기준으로 대조구 온실의 비용 절감율은 87%로 나타났다. 처리구 및 대조구 온실의 작물생육을 비교한 결과 초장과 엽록소 함량에서 차이가 발생하였으나 두 온실의 난방온도가 거의 동일하므로 전체적인 생육은 큰 차이가 없는 것으로 분석되었다. 원예시설의 난방에너지 절감효과를 극대화하기 위해서는 본 연구의 난방패키지를 구성하는 개별 기술뿐 아니라 이미 개발된 고효율 공조기 이용기술, 보온성 향상기술, 온도관리 기술 등을 지역, 시설, 작목, 작형 등에 최적화하여 조합할 수 있는 추가적 패키지 모델의 개발 연구가 필요한 것으로 판단되었다.

일사영향권내 비균질 토양의 열적거동 예측 모델 (Model to Predict Non-Homogeneous Soil Temperature Variation Influenced by Solar Irradiation)

  • 김용환;현명택;강은철;박용정;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제26권4호
    • /
    • pp.1-7
    • /
    • 2006
  • This study is to develop a model to predict the soil temperature variation in Korea Institute of Energy Research using its thermal properties, such as thermal conductivity and diffusivity. Soil depth temperature variation is very important in the design of a proper Ground Source Heat Pump (GSHP) system. This is because the size of the borehole depends on the soil temperature distribution, and this can decrease GSHP system cost. If the thermal diffusivity and thermal conductivity are known, the soil temperature can be predicted by either the Krarti equation or the Spitler equation. Then a comparison with the Krarti equation and Spitler equation data with the real measured data can be performed. Also, the thermal properties can be reasonably approximated by performing a fit of the Krarti and Spitler equations with measured temperature data. This was done and, as a result, the Krarti equation and Spitler equation predicted values very close to the measured data. Although there is about a $0.5^{\circ}C$ difference between the deep subsurface prediction (16m - 60m), with this equation, were expected to have model this Non-Homogeneous Soil Temperature phenomenon properly. So, it has been shown that a prediction of non-homogeneous soil temperature variation influenced by solar radiation can be achieved with a model.

친환경에너지타운에서 보어홀지중열 저장(BTES) 활용 융복합 열에너지 공급 시스템 사례 연구 (International Case Studies on the Eco-friendly Energy Towns with Hybrid Thermal Energy Supply System and Borehole Thermal Energy Storage (BTES))

  • 심병완
    • 자원환경지질
    • /
    • 제51권1호
    • /
    • pp.67-76
    • /
    • 2018
  • 본 연구는 해외 친환경에너지타운에서 보어홀 지중열 저장(BTES) 기술을 활용한 융복합 열에너지 공급 시스템의 3가지 사례로서 캐나다의 ADEU(Alexandra District Energy Utility) 및 DLSC(Drake Landing Solar Community)와 덴마크의 Brædstrup Solpark를 조사하였다. 이들 지역 냉난방 시스템들은 효율과 지속가능성을 높이기 위하여 다중 에너지원을 활용하고 있다. ADEU는 리치몬드시에서 726 개의 지중열교환기로 이루어진 지열필드 및 천연 가스 백업 보일러를 이용한 대규모 지역에너지 공급을 위해 개발되었다. 그리고 캘거리시 인근 Okotoks에 위치한 DLSC는 여름철에 풍부한 태양열 에너지를 144 개의 지중열교환기를 통하여 지중에 저장하고 겨울철 난방을 위해 각 주택에 열에너지를 분배하는 계간축열 방식의 지역난방 시스템이다. Brædstrup Solpark 지역난방 시스템은 태양열, 히트 펌프, 보일러 플랜트 및 계간축열을 위한 48 개의 지중열교환기로 구성되며 다중 에너지원을 이용하여 열을 저장한다. BTES 시추공의 심도와 축열량은 지하수 유동과 지반의 열물성에 따라 영향을 많이 받는다. 이러한 시스템들은 경쟁력 있는 에너지 가격으로 장기적인 에너지를 공급함으로서 신뢰성과 경제성을 평가 받았다. 그리고 ADEU와 Brædstrup Solpark는 서비스 영역 확장을 위한 장기 에너지 공급 계획을 기반으로 확장이 진행중이다. 본 조사를 통하여 이러한 시스템들은 사회 경제적인 이익 뿐만아니라 환경적인 관점이 설계에 반영되어 있는 것을 알 수 있었다. 국내에서도 이러한 프로젝트를 실시하기 위해서는 지방 정부 또는 관련 기관의 에너지 정책 지원 뿐만아니라, 관리 기관 설치를 통한 장기적인 협력이 필요하다.

에너지 및 반추위 미분해단백질 수준을 달리한 사료급여가 비유중기 유우에 미치는 영향 (Effects of different energy and rumen undegradable protein levels on dairy cow's production performance at mid-lactation period)

  • 박수범;임동현;박성민;김태일;최순호;권응기;서자겸;서성원;기광석
    • 농업과학연구
    • /
    • 제40권4호
    • /
    • pp.333-338
    • /
    • 2013
  • Sources of energy and rumen undegradable protein (RUP) have been used to meet nutrient requirements for high producing dairy cows. However studies for manipulation the levels of energy and RUP in diets have been mainly achieved using dairy cows at early-lactation period. The objective of this study thus, was to investigate the effects of different energy and rumen undegradable protein (RUP) levels on dry matter intake and milk yield in Holstein cows at mid-lactation period. Basal diet was prepared as TMR to meet nutrient requirements for dairy cows at mid-lactation according to NRC recommendation. Cows of control group (Con) were fed only basal diets while ground corn (0.5 kg/d), heat-treated soybean meal (0.5 kg/d), and their mixture (0.25 kg of each supplements/d) were added to diets for cows of treatment groups (T1, T2, and T3 respectively) to modulate the level of energy and RUP contents in diets. Addition of energy or RUP source in basal TMR did not affect in total DMI while TMR intake tended to be higher in Con compared to T3. Cows fed T3 diets tended to show increased milk yield and MUN content than those of Con. Cows for T2 as well as T3 had lower ADG (P<0.05) compared with those of Con. We concluded that the addition of RUP source in diets for dairy cows on mid-lactation period might cause the decrement of DMI and ADG.

지열 난방시스템을 이용한 분만돈사의 난방효과 분석 (Evaluation on Heating Effects of Geothermal Heat Pump System in Farrowing House)

  • 최희철;박재홍;송준익;나재천;김민지;방한태;강환구;박성복;채현석;서옥석;유영선;김태원
    • 한국축산시설환경학회지
    • /
    • 제16권3호
    • /
    • pp.205-215
    • /
    • 2010
  • 지열히트펌프를 이용한 축사용 냉난방시스템을 개발하고 농장 적용성을 검토하기 위하여 330 $m^2$ 규모의 농장에 개발 시스템을 설치하여 돈사에서의 난방 이용효과를 분석하였으며, 그 결과는 다음과 같다. 1. 지열 난방시 부하량은 24,104 kcal이었으며 농장시험 지열이용 냉난방시스템의 제원은 히트펌프 용량은 10 USRT 였으며, 상부 덕트형 30,000 kcal 홴코일유니트를 사용하였으며 FCU의 풍량은 90 $m^3$/분 이었다. 2. 지열 난방 1주령시 외부 최고기온 $14.2^{\circ}C$, 최저 영하 $9.3^{\circ}C$일때 시험구는 평균 $21.5^{\circ}C$로서 대조구 $19.8^{\circ}C$에 비하여 높았다. 3. 지열 난방 시험돈사의 먼지 농도는 PM10 185.3, PM2.5 40, PM1.0 $23.4{\mu}g/m^3$으로 대조구 PM10 481.4, PM2.5 47, PM1.0 $28.2{\mu}g/m^3$에 비하여 낮았다.4. 지열 난방 시험돈사의 유해가스농도는 $CO_2$ 1,470, $NH_3$ 10.6, $H_2S$ 0.05 ppm으로서 대조구 $CO_2$ 2,025, $NH_3$ 23.3, $H_2S$ 0.69 ppm에 비하여 유의적으로 (p<0.05) 낮았다. 5. 지열난방시 복당 이유두수는 10.5두로 대조구 10.4두에 비하여 높았으며 이유시체 중도 6.93 kg으로 대조구 6.86 kg에 비하여 컸으며 특히 온도가 낮은 대조구에서 모돈사료 섭취량이 99.6 kg으로 시험구 88.2 kg 보다 유의적으로 (p<0.05) 많았다. 6. 지열 난방시 외부기온과 지하수 순환량에 있어서 외부기온이 낮을 경우 1일간 8.4-12.9톤으로 지하수 순환량이 많았다.

Comparative Calorimetric Evaluation of Ammoniated Straw-Based Rations Supplemented with Low Levels of Untreated and Formaldehyde Treated Groundnut Cake and Fish Meal with Respect to Growing Buffalo Calves

  • Tiwari, C.M.;Jadhao, S.B.;Chandramoni, Chandramoni;Murarilal, Murarilal;Khan, M.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제13권6호
    • /
    • pp.761-773
    • /
    • 2000
  • Eighteen growing male Murrah buffalo (Bubalus bubalis) calves were divided into three groups consisting of six animals each and fed three urea ammoniated wheat straw (UAS) -based rations supplemented with concentrate mixtures (roughage: concentrate ratio 58:42) containing deoiled ground nut cake, GNC (8%), formaldehyde treated GNC (8%) or fish meal (8%) to undertake comparative evaluation of these rations in terms of their $CH_4$ production and growth (285 d duration) potential. A digestibility trial (10 d duration) was followed by a comparative calorimetric study in respiration chamber. Dry matter (DM) intake (84.3 to $89.3g/kg\;W^{0.75}d^{-1}$) did not differ between treatments. The digestibility coefficient of DM, organic matter (OM), crude protein (CP), neutral and acid detergent fiber did not differ significantly in different diets. Urinary energy loss as a percent of gross energy (GE) was not affected by diets. Average values of $CH_4$ production were 84.3, 77.6 and 99.1 g/d and $CH_4$ energy losses as percent of gross energy were 5.7, 5.2 and 6.1 percent on .GNC, formaldehyde treated GNC and fishmeal, respectively, and did not differ significantly. When expressed per unit of digestible OM intake, $CH_4$ production (g) was lower (p<0.05) on formaldehyde treated GNC (30.6) than on untreated GNC (30.6) and fish meal (31.9). Total ME intake and heat production were similar and hence the energy balances on different diets were similar. Nutritive value of rations in terms of digestible CP and ME were similar. Average daily gain calculated on the basis of regression of fortnights on cumulative liveweight gain in calves fed on concentrate containing unprotected GNC, protected GNC and fish meal were 437.1, 483.9 and 481.6 g, respectively. This indicated that the intake of energy was sufficient to meet the requirement of calves growing at 400 g per d. However, CP intake was around 150% of the stipulated standard (Kearl, 1982). Feed conversion ratios on unprotected GNC, protected GNC and fish meal were 11.60, 11.10 and 10.4 respectively. It was concluded that because significantly (p<0.05) low $CH_4$ is produced on protected GNC (8%), it is very good and sustainable protein source in comparison to poor quality fish meal and untreated GNC to be used in concentrate mixture for supplementing UAS-based diets.

실측데이터를 이용한 저에너지주택의 에너지성능평가 (Energy Performance Evaluation of Low Energy Houses using Metering Data)

  • 백남춘;김성범;오병칠;윤종호;신우철
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.369-374
    • /
    • 2015
  • This study analyzed analyzes the energy performance of six houses in Daejeon completed which were built in 2011. Observed The observed houses, which were all designed and constructed inof the same size and structure, are were highly insulated with triple Low-E coating windows; the insulation level of the walls is was $0.13W/m^2K$ and that of the roof is was $0.10W/m^2K$. As electric houses, all of the energy supplied to the houses, including for cooking, is was supplied by electricity. A and 3~4 kWp of photovoltaic system and a 3~5 kW of ground source heat pump (GSHP) were installed in each house tofor providing provide space heating/and cooling and hot water are installed. We constructed a Web-based remote monitoring system in order to understand energy consumption and the dynamic behavior of the energy system. T, and the results of our metering data analysis of 2013 are as follows. First, the annual residential energy consumption is was 4,400 kWh (${\sigma}=1,209$) and GSHP energy consumption is was 5,182 kWh (${\sigma}=1,164$). Second, residential energy consumption ranked highest in average energy usage, with at 45% of the total, followed by heating with at 30%, hot water supply with at 17% and cooling with at 6%. Third, the average energy independence rate is was 51.8%, the GFA (Gross gross floor area) criteria average energy consumption unit is was $48.7kWh/m^2yr$ (${\sigma}=10.1$), and the net energy consumption unit (except the energy yield of the PV systems) is was $24.7kWh/m^2yr$ (${\sigma}=8.8$).

시뮬레이션 모형에 의한 온실의 열환경 분석 (Analysis of Greenhouse Thermal Environment by Model Simulation)

  • 서원명;윤용철
    • 생물환경조절학회지
    • /
    • 제5권2호
    • /
    • pp.215-235
    • /
    • 1996
  • 본 연구에서 수행한 Model 시뮬레이션에 의한 열환경 분석 기법은 지역별로 다양한 기상여건 하에서 대상온실의 난방 및 냉방부하를 보다 합리적으로 예측할 수 있을 뿐만 아니라 냉방이나 난방용 시스템의 결정을 비롯한 난방대책을 수립하고, 에너지 이용 전략의 수립이나 계절적인 작부계획 수립, 온실산업용 적지선정 등에 유익하게 활용될 수 있을 것이라 판단된다. 본 연구에서는 온실의 적극적인 환경조절 유형을 난방과 냉방의 두 가지로 대별하고, 난방 소요열량 산정을 비롯하여 야간의 보온 커튼효과, Heating Degree-Hour 산정 등 난방과 관련된 시뮬레이션은 동적 모형을 이용하여 시간별, 일별 및 월별로 검토하였으며, 환기를 비롯한 차광, 증발냉각시스템의 효과 분석은 정적모형을 이용하여 검토하였다. 특히 하절기 지하수와 같은 저온수를 직접 이용하거나 Heat Pump를 통하여 확보될 수 있는 저온수를 이용하여 온실의 피복면에 살수함으로서 확보할 수 있는 온실냉방효과를 검토하는 데는 1.2m$\times$2.4m 크기의 모형온실을 제작하여 기초실험을 수행함으로서 동절기의 수막시스템의 보온효과와 마찬가지로 하절기 냉방 효과를 거둘 수 있다는 가능성을 확인하였다. 본 연구에 활용된 온실의 수치 환경모형 중 난방관련 시뮬레이션용 동적 수치모형은 소기의 목적을 달성하는데 충분히 응용될 수 있는 이론모형이다. 이 이론모형이 범용성이 높은 것은 온실 내ㆍ외의 미기상 변화, 특히 난방이나 냉방이 본격적으로 요구되는 기간동안에 온도, 습도, 일사, 풍속 등의 미기상 인자들을 면밀하게 관찰하여 실측된 자료를 바탕으로 개발되었고, 다양한 자료에 의해 충분히 검정되었기 때문이다. 본 연구에서는 경남 진주지역의 어느 특정 기간(1987년)의 시간별 기상자료를 중심으로 온실의 열적 환경변화에 대한 수치모형 시뮬레이션을 실시하였으며, 아직 수치모형에 의한 시뮬레이션이 불가능한 일부 냉방효과를 검토하는 데는 모형 실험을 실시하였으며, 그 결과를 요약하면 다음과 같다. 1. 주간과 야간의 설정온도를 달리하고 다단계 변온조절방식으로 시뮬레이션을 행한 결과 난방 소요열량은 난방 설정온도에 따라 현저한 차이를 보였다. 특히 주간 설정온도에 비하여 야간 설정온도가 난방 소요열량에 예민하게 영향을 미치므로 야간의 설정온도 결정에 신중을 기해야 할 것으로 판단된다. 2. 기존의 Heating Degree-Hour 자료는 평균 외기온을 중심으로 임의의 설정온도에 대하여 산정된 값이므로 난방 소요열량에 대한 상대적인 비교수단은 되나 고려되는 기상인자의 제한과 설정온도의 임의성 때문에 실용성이 부족하다. 따라서 본 연구에서 제시된 것처럼 온실 주변의 제반 미기상 인자나 경계조건이 반영됨은 물론 작물의 생육상태 및 구체적인 설정온도까지도 고려하는 동적 수치모형으로 시시각각으로 예측된 실내기온을 중심으로 재배기간 동안의 난방열량을 적산함이 합리적이라 판단된다. 기존의 MDH 자료로 난방 설계를 할 경우에는 지나치게 과잉설계 될 가능성이 있다. 3. 산정된 난방 소요열량은 물론 커튼의 보온성능도 월별 기상여건에 따라 현저한 차이를 보이며, 시뮬레이션에 이용된 커튼의 경우 높은 보온효과를 보임으로서 년 평균 50% 이상의 난방 에너지를 절감할 수 있으며, 동절기 3-4개월의 집중 난방기에 에너지가 크게 절감됨을 발견할 수 있다. 4. 고온기 환기성능은 온실의 구조, 기상조건, 작물의 생육상태 등에 따라 다소의 차이가 있으나 환기율에 의해 크게 좌우되며, 시뮬레이션에 이용된 두 가지 농가보급형 온실 모두 환기율의 증가에 따른 실내기온의 강하 효과가 환기율이 1회/min 정도를 넘어서면서 급격히 둔화되는 현상을 보인다. 이는 기존에 권장되고 있는 적정 환기율인 1회/min 전후의 환기 시스템을 갖추는 것이 합리적임을 확인해 준다. 5. 작물이 성숙된 유리온실에서 외기의 상대습도가 50%인 쾌청한 주간동안 연속적으로 1회/min로 환기를 시킬 경우 실내기온 36.5$^{\circ}C$의 대조구에 비한 온도강하는 50% 차광만 했을 시 2.6$^{\circ}C$이고 효율 80%의 Pad & Fan 시스템만 작동시 6.1$^{\circ}C$ 정도이며, 차광과 냉각시스템을 동시에 작동시는 약 8.6$^{\circ}C$로서 외기온보다 3.3$^{\circ}C$가 낮은 28$^{\circ}C$까지 실내온도를 낮출 수 있으나, 동일 조건하에서 외기의 상대습도가 80%로 높은 경우에는 Pad & Fan시스템에 의한 온도강하가 2.4$^{\circ}C$에 불과하여 50% 차광하에서도 외기온 이하로 실내온도를 낮출 수 없음을 알 수 있다. 6. 하절기 3개월(6/1-8/31)동안 Pad & Fan 시스템의 냉방효과($\Delta$T)는 설정된 작동 온도에 따라 다소 차이를 보일 것으로 예상되나 본 시뮬레이션에서 설정한 시스템의 작동 온도 27$^{\circ}C$에서 상대습도와의 상관관계는 대략 다음과 같았다: $\Delta$T= -0.077RH+7.7 7. 전형적인 하절기 주간기상 하에서 경시적 냉방효과를 분석한 결과 환기만으로는 실내기온을 외기온 보다 5$^{\circ}C$ 높게 유지하는 정도가 고작이고, 차광이나 증발식 냉방시스템 만으로는 작물이 성숙한 단계에서조차도 외기온 이하로 떨어뜨리기가 어려우나 차광과 아울러 증발식 냉방을 병행할 경우에는 작물상태에 따라 다소 차이는 있지만 실내기온을 외기온보다 2.0-2.3$^{\circ}C$ 낮게 유지할 수 있음을 발견할 수 있다. 8. 일사가 차단된 27.5-28.5$^{\circ}C$의 외기온하에서 6.5-8.5$^{\circ}C$의 냉수를 온실 바닥면적 1$m^2$당 1.3 liter/min의 유량으로 온실표면에 살수했을 때 실내기온을 외기온보다 1$0^{\circ}C$ 낮은 16.5-18.$0^{\circ}C$ 정도로 낮출 수 있었다. 앞으로 살수 수온(T$_{w}$ )이나 외기온(T$_{o}$ ) 뿐만아니라 살수율(Q)에 따라 온실기온 (T$_{g}$ )에 미치는 상관 관계 T$_{g}$ = f(T$_{w}$ , Q, T$_{o}$ )를 구명하여 지하수 자체 또는 Heat Pump를 이용한 지하수온 이하의 냉수로 온실냉방의 가능성을 구명하는 것이 앞으로의 과제이다.

  • PDF