• Title/Summary/Keyword: Ground grid

검색결과 287건 처리시간 0.027초

반구형 접지모의시스템을 이용한 접지전극의 형상에 따른 대지전위상승의 분석 (The Analysis of Ground Potential Rise for Shapes of Grounding Electrode Using Hemispherical Grounding Simulation System)

  • 길형준;최충석;이복희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권7호
    • /
    • pp.319-325
    • /
    • 2005
  • In order to analyze ground potential rise of grounding system installed in buildings, the hemispherical grounding simulation system has been designed and fabricated as substantial and economical measures. Ground potential rise(GPR) has been measured and analyzed for shapes of grounding electrode using the system in real time. The system is apparatus to have a free reduced scale for conductor size and laying depth of a full scale grounding system and is constructed so that a shape of equipotential surface is nearly identified a free reduced scale with a real scale when a current flows through grounding electrode. The system was composed of a hemispherical water tank, AC Power supply, a movable potentiometer, and test grounding electrodes. The test grounding electrodes were fabricated through reducing grounding electrode installed in real buildings such as rod type, mesh grid type. When a mesh grid type was associated with a rod type, GPR was the lowest value. The proposed results would be applicable to evaluate GPR in the grounding systems. and the analytical data can be used 0 stabilize the electrical installations and prevent the electrical disasters.

Distribution of Potential Rise as a Function of Shape of Grounding Electrodes

  • Gil, Hyoung-Jun;Choi, Chung-Seog;Kim, Hyang-Kon
    • 조명전기설비학회논문지
    • /
    • 제21권4호
    • /
    • pp.73-79
    • /
    • 2007
  • In order to analyze the potential rise of grounding systems installed in buildings, a hemispherical grounding simulation system was studied. Potential rise was measured and analyzed regarding the shape and distance of the grounding electrodes by using this system. The system was composed of a hemispherical water tank, AC power supply, a movable potentiometer, and test grounding electrodes. The potential rise was measured in real time by the horizontal moving probe of be potentiometer. The test grounding electrodes were fabricated through reducing the grounding electrode installed in real buildings such as the ground rod, grounding grid and so on. The potential rise was displayed in a two-dimensional profile and was analyzed regarding the shapes of the ground electrodes. The potential rise of the grounding grid combined with a ground rod was the lowest of every grounding electrode tested. The proposed results can be applicable to evaluating ground potential rise in grounding systems, and the analytical data can be used to stabilize the electrical installations and prevent electrical disasters.

A Study on the Agent (Protective Device)-based Fault Determination and Separation Methodology for Smart Grid Distribution System

  • Ko, Yun-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.102-108
    • /
    • 2015
  • This paper proposes a new fault isolation methodology for a smart protective device which plays an agent role on the smart grid distribution system with the distributed generation. It, by itself, determines accurately whether its protection zone is fault or not, identifies the fault zone and separates the fault zone through the exchange of fault information such as the current information and the voltage information with other protective devices using bi-directional communication capabilities on the smart grid distribution system. The heuristic rules are obtained from the structure and electrical characteristics determined according to the location of the fault and DG (Distributed Generation) when faults such as single-phase ground fault, phase-to-phase short fault and three-phase short fault occur on the smart grid distribution system with DG.

VPI-based Control Strategy for a Transformerless MMC-HVDC System Under Unbalanced Grid Conditions

  • Kim, Si-Hwan;Kim, June-Sung;Kim, Rae-Young;Cho, Jin-Tae;Kim, Seok-Woong
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2319-2328
    • /
    • 2018
  • This paper introduces a control method for a transformerless MMC-HVDC system. The proposed method can effectively control the grid currents of the MMC-HVDC system under unbalanced grid conditions such as a single line-to-ground fault. The proposed method controls the currents of the positive sequence component and the negative sequence component without separating algorithms. Therefore, complicated calculations for extracting the positive sequence and the negative sequence component are not required. In addition, a control method to regulate a zero sequence component current under unbalanced grid conditions in the transformerless MMC-HVDC system is also proposed. The validity of the proposed method is verified through PSCAD/EMTDC simulation.

탄소접지극이 병설된 접지그리드의 접지임피던스의 해석 (Analysis of the Ground Impedance of Ground Grids Combined with the Carbon Ground Electrodes)

  • 이복희;엄상현;김유하;이강수;전병욱;최종혁
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.36-42
    • /
    • 2013
  • This paper deals with the frequency-dependent ground impedance of ground grids combined with the carbon ground electrodes. Ground grids are generally valid for multipurpose grounding systems as well as lightning protection systems. The carbon ground electrodes may be supplementarily used to reduce the high frequency ground impedance and to improve the transient response to surge currents. The frequency-dependent ground impedances of ground grids combined with or without the carbon ground electrodes were measured and their simulations with due regard to frequency-dependent soil resistivity were implemented by using EMTP program and Matlab modeling. As a consequence, the ground impedance of ground grids combined with the carbon ground electrodes is significantly reduced when the test current is injected at the terminal of the carbon ground electrode. The measured and simulated data for the test ground grids fairly agree with each other. It was found that the proposed method of simulating the frequency-dependent ground impedance is distinguished. The simulation techniques of predicting accurately the ground impedances without actual measurements can be used in the design of grounding systems based on ground grids and the carbon ground electrodes.

형상이 다른 접지전극에 접속된 심매설 봉상 접지전극의 임펄스접지임피던스 특성 (Impulse Ground Impedances of a Deeply Driven Ground Rod Combined with Different Shape Grounding Electrodes)

  • 이복희;이수봉;장근철
    • 조명전기설비학회논문지
    • /
    • 제19권2호
    • /
    • pp.63-68
    • /
    • 2005
  • 본 논문은 메쉬 접지전극이나 침부 매설지선이 연결된 심매설 봉상 접지전극의 실효임펄스접지임피던스의 특성을 다루었다. 시험용 접지전극의 전위상승은 인가된 임펄스 전류의 상승시간의 함수로 측정되었고, 실효임펄스접지 임피던스는 산출되었다. 심매설 봉상 접지전극의 임펄스접지임피던스는 임펄스 전류의 상승시간에 강하게 의존하며 메쉬 접지전각과의 병렬연결에 의해 확연히 감소하였다.

영상사진을 이용한 지반공학적인 선구조분석 연구 (A Study on Geotechnical Lineament Analysis by Image Processing Method)

  • 이수곤;금동헌
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.593-600
    • /
    • 2000
  • Most of ground investigations can be grasped geological distribution which like rock name, geological structure, soil condition, underwater condition, land slide, ground cave-in, ground collapse by geological survey. But geological survey is limited to part region geological structure, not wide region. Therefore, Image Processing Method must need to grasp wide region geological structure. The object of this research is presented analysis data of geotechnical engineering in first step investigation.

  • PDF

패키지의 주파수 의존형 파워 및 그라운드 평판 모델 (Frequency-Variant Power and Ground Plane Model for Electronic Package)

  • 이동훈;어영선
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.385-388
    • /
    • 1999
  • A new frequency-variant equivalent circuit model of power/ground plane is presented. The equivalent circuit is modeled with grid cells. The circuit parameters of each cell were extracted by using Fasthenry. To verify the developed circuit model, its s-parameters are compared with the measured s-parameters 〔2〕 and the full-wave simulation-based s-parameters. Consequently, it is shown that our frequency-variant equivalent circuit model can accurately predict imperfect ground effects under the high frequency operation of electronic package.

  • PDF

DCM 배치 형상에 따른 연약지반 거동 특성에 관한 연구 (A Study on Behavior Characteristics of Soft Ground by DCM Arrangement Type)

  • 유승경;이종영;홍기권
    • 한국지반신소재학회논문집
    • /
    • 제20권4호
    • /
    • pp.125-131
    • /
    • 2021
  • 본 연구에서는 DCM으로 보강된 연약지반의 거동특성을 평가하기 위하여, 모형실험결과를 이용하여 DCM 배치 형상에 따른 침하-측방변위, 침하-융기 관계를 분석하였다. 그 결과, 모형지반의 지표면 누적 침하 거동은 DCM이 적용된 지반에서 상대적으로 침하가 적게 발생하였고, 격자식, 벽식, 말뚝식의 순으로 동일한 하중조건에서 침하량이 적게 발생한 것을 알 수 있었다. 이와 같은 경향은 측방변위량과 융기량에 대해서도 동일하게 나타난 것을 확인하였다. 연약지반의 침하와 측방유동의 관계를 분석한 결과, 기존 연구(Leroueil et al., 1990)와 유사한 거동을 보이는 것으로 확인되었다. DCM 배치 형상에 따른 지반개량효과를 평가한 결과, 측방유동과 지반 융기에 대하여 격자식 보강이 벽식 및 말뚝식 보강에 비해 탁월한 지반개량효과를 보유한 것으로 평가되었다.

워게임모델의 가상환경격자정보 개선과 구축 기법 (A Technic to Improve and Implement Virtual Environment Grid Information in War-game Model)

  • 최병무;양해술
    • 한국산학기술학회논문지
    • /
    • 제10권4호
    • /
    • pp.785-794
    • /
    • 2009
  • 워게임모델에서 가상환경격자정보에 관한 개선과 구축기법을 연구하였다. 가상환경자료는 지상, 해상, 공중으로 구분하여 관리 및 운용한다. 가상환경자료는 지리정보와 지형형태정보로 구축 및 관리한다. 지리정보는 격자(Grid) 형태로서 격자위치좌표와 수심을 파일로 관리한다. 그 격자정보파일의 수심값을 이동가능대표값(GCV)으로 개선하고, 조석차가 심한지역에 대해서 동적가상환경구축기법을 제안하였다. 제안된 시스템 의 구현 및 시험을 통하여 동적 가상환경을 워게임모델에 적용이 가능하다는 것을 알 수 있었다.