• 제목/요약/키워드: Ground area

검색결과 3,393건 처리시간 0.028초

아산지역에서의 연약지반개량을 위한 시험시공 결과에 대한 평가 (An Evaluation on the Result of Pilot Test for Soft Grounnd Improvement in Asan)

  • 이재원;김성인
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.615-622
    • /
    • 2000
  • This paper is relate to the result of pilot test in Asan. In order to evaluate the characteristics of behavior and deformation in Asan and to analyse the effect of soft ground treatment, preloading, two types of paper drain and pack drain were constructed in the ground. Settlement gauges, pressure meters, pressure cells and ground water gauges were monitored and also borings and piezoncone tests were performed. As a result of analyse, every vertical drained area was consolidated over 90% degree of consolidation but preloaded area was not reached to 90%.

  • PDF

비탈면에 적용된 다구근 앵커의 보강효과 연구 (A Study On The Reinforcing Effect Multibell Anchor Applied To The Cut Slope)

  • 차경섭;김선주;김태훈
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.1286-1293
    • /
    • 2010
  • The ground anchor used in domestic area, which resists by adhesion between anchor body and the ground to the external force, seems not to be adequate for soft ground and urban area where the boundary between structures is close because the ground is disturbed and lost its strength during boring. In order to overcome such a shortcoming an expanded anchor system has been developed. The ground expansion is accomplished by means of Pulse Discharge Technology. In this technology, a high voltage of electricity is stored and discharged in milliseconds which induces high pressure acting on the ground. By making a couple of bulbs, a passive resistance as well as shaft resistance are mobilized, and therefore a higher pullout resistance comparing existing ground anchors is developed.In this study, a couple of full scale tests were conducted in order to figure out how much the resistance of an expanded anchor increases comparing to the straight. As a result, it was found that a remarkable increase in ultimate pullout capacity is observed for the soft ground and as the number of bulb increases. In addtion, as a result of applying to a cut slope reinforcement, it appeared that the length of fixed zone of anchor can be reduced effectively.

  • PDF

실내시험을 이용한 저치환 보강지반의 평가 (Evaluation of the Low Replacement Reinforced Ground Using Laboratory Tests)

  • 배우석
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.131-137
    • /
    • 2008
  • SCP(Sand Compaction Pile) method that forms a composite ground by driving compacted sand piles into the soft ground. This method is one of the soil improvement techniques for reinforcing and strengthening soft ground deposits. This thesis describes the investigation on the behavior of soft ground reinforced with SCP by low improvement ratio. Direct shear test and consolidation test carried out to verified behavior of composite ground reinforced with SCP. Test results were discussed with reference to the amount of consolidation settlement, variation of shear resistance with area replacement ratio and effect of the stress concentration. And, laboratory model loading test carried out to verified the effect of the location and failure mode of reinforced embankment. Residual shear strength varies with the area replacement and constrict load in the low replacement ratio. Calculated stress concentration ratio overestimate than proposed valve by experimental, theoretical and analytical method. As regards the location, improving right below of the top of the slope was more effective than below of the toe of the slope. This thesis carried out to obtain fundamental information of behavior of the composit ground. Hereafter, centrifuge test that reproduce stress state of the in-situ must be necessary through the further study about pile penetration, reinforce position and construct time.

고로슬래그 미분말을 사용한 콘크리트의 방청성능에 관한 연구 (A Study on the Rust-protection Performance of Concrete using Ground Granulated Blast-furnace Slag)

  • 박상준;김동석;원철;이상수;김영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.529-532
    • /
    • 2001
  • In this paper, rust-protection performance of concrete using ground granulated blast-furnace slag are discussed. 4 kinds of W/B in combination with 3 kinds of replacement ratio of ground granulated blast-furnace slag and 2 kinds of chloride ion contents of are selected as experimental parameters. According to the experimental results, as the replacement ratio of ground granulated blast-furnace slag is increased, the corrosion area of steel bar tends to be decreased. However, as the autoclave cycle and chloride ion contents are increased, the corrosion area of steel bar is increased. In conclusion, when the replacement ratio of ground granulated blast-furnace slag is 50%, the strength and rust-protection performance appear to be most excellent.

  • PDF

도심지 지하철 터널의 붕괴유형과 원인 (Modes and Causes of Collapse of Subway Tunnels)

  • 박광준;이인근
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1993년도 봄 학술회 논문집
    • /
    • pp.41-48
    • /
    • 1993
  • The 2nd phase of Seoul Subway, Lines 5,6,7 and 8, is in progress. To reduce the surface traffic congestion during construction the greater part of the system has been engineered by bored tunnelling. The current tunnelling methodology is based on the New Austrian Tunnelling Method. Serveral collapses have been reported to date. Most of the collapses took place in the area forwed with soft ground. The modes and causes of the collapses were progressive failures in the unsupported surface and sliding failures due to the unfavourable joint direction. The major causes turned out to be the weakness of ground and the sudden influx of ground water from the surface. Some measures to prevent the failures are also presented. To ensure the safe tunnelling ghrough the soft ground the unsupported excavation area has to be minimized and closed as early as possible. Additional support measures such as supporting core, sealing shotcrete, forepoling, spread footing, face rock bolting and grouting should be employed as well depend on ground conditions.

  • PDF

미세진동 측정을 통한 지반응답특성 평가 (Estimation of Ground Response Characteristics by Microtremor)

  • 조성호;이일화;고학송
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.718-721
    • /
    • 2005
  • The purpose of the study is to evaluate the usage of microtremor in estimation of subsurface structure and ground response to ground motion. Ground motion amplification based on site condition of an area is an important parameter for dynamic design. Microtremor cover the characteristics in a low frequency range, while forced vibrations cover them in a high-frequency range. Microtremor consider ground characteristics and offer transfer function in area. To determine the dominant frequency, the passive microtremor measurement is performed and to determine the transfer function of test site, active microtremor measurement is performed. Microtremor measurement in the site is compared with theoretical transfer function calculated from the known structures.

  • PDF

지하공동에 의한 지표침하지역의 지반안정성 평가 (Ground Stability Assessement for the Mining Induced Subsidence Area)

  • 권광수;박연준;신희순;신중호
    • 터널과지하공간
    • /
    • 제4권2호
    • /
    • pp.170-185
    • /
    • 1994
  • Surface subsidence is one of the problems caused by mined out caverns. Depending on the geologic conditions and mining methods, subsidence can occur in various forms. This report describes the ground stability assessment for the mining induced subsidence area where unfilled caverns still exist abandoned. Geologic features which could affect the stability of the ground were investigated and all the possible geophysical methods were employed to obtain data that could explain the state of the ground in question. Basic rock tests were conducted from the drill cores and rock mass classification was performed by core logging and borehole camera investigation. Numerical analyses were carried out to predict the ground stability using data obtained by various investigations. The result could have been more reliable if in-situ stress were measure and reflected in the numerical analysis.

  • PDF

서울시내(布內) 초중고등학교(初中高等學校) 토양(土壤)으로부터 비정형(非定型) Mycobacteria와 Nocardia의 분리(分離) 및 생화학적(生化學的) 동정(同定) (Isolation and Identification of Opportunist Mycobacteria and Nocardia from Soil Specimens of School Ground in Seoul City)

  • 최철순;양용태
    • 대한미생물학회지
    • /
    • 제11권1호
    • /
    • pp.69-78
    • /
    • 1976
  • There have been increasing reports of mycobacterioses in man and animals caused by "atypical" or "opportunist" mycobacteria. At the presnt, "opportunist mycobacterioses" are not generally responsive to antituberculosis drugs, and therefore, create considerable problems with regard to chemotherapy and control measures. In recent years studies have been made to isolate opportunist mycobacteria from soil, house-dusts and tap-water. It seemed quite interesting to define the extent of circumstantial presence of "opportunist" mycobacteria and nocardia in the soils of school-ground of primary schools and middle-high schools. This communication is the results of pilot study to isolate and identify "opportunist" mycobacteria and nocardia from 504 soil specimens of 72 schools in Seoul City. 1. Of a total of 59 isolates from 504 soil specimens tested, 32 strains were identified as opportunist mycobacteria and 27 strains as nocardia. 2. Isolation rates of opportunist mycobacteria by the areas(of specimen collection) were as follows: 36.4% in the southern area of Han-River, 33.3% in the central area, 22.7% in the outskirt area and 16.6% in the intermediate area. There observed no apparent difference in the isolation rates both-between the areas and between primary schools and middle-high schools. However, a significant difference was noted in the isolation rates between the places of soil sampling in a given school(P<0.05), i.e., the highest was the soil of refuge heaps(15.2%), and tap-water pole area(11.1%), the school-lavatory entrance(9.7%), the school gate entrance(5.5%), and iron-bar play ground(2.7%). The soil specimens from the center of school ground and from school building entrance yielded none of mycobacterial isolates. 3. Isolation rates of nocardia by the areas were as follows: 33.3% in the central area, 31.8% in the outskirt area, 27.3% in the southern ares of Han-River and 11.1% in the intermediate area. As in the case of mycobacteral isolates, there observed no apparent differences in the isolation rates both between the areas and between primary schools and middle-high schools, but a significant difference was noted between the places of soil sampling(P<0.05), i.e., the highest was the soil of school building entrance(15.2%), and of school gate entrance(6.9%), refuge heaps(5.5,%), iron-bar play ground(4.1%), the school-lavatory entrance(2.7%) and tap-water pole area(2.7%), respectively. The soil specimens from the center of, school ground yielded none of nocardia isolates. 4. Of the 32 strains of isolated mycobacteria. 15 strains were slow-growing mycobacteria and the remaining 17 strains belonged to the rapid growers. Of the 15 slow-growers. 4 strains were M. scrofulaceum-szulgai complex, 3 M. gordonae, 4 M. terrae-triviale complex, 2 M. avium-intracellulare-xenopi complex, and 2 unclassified schotochromogens. Of the 17 strains of rapid growers, 12 were M. diernhoferi, 2 M. fortuitum-peregrinum complex, 2 M. vaccae and one M. flavescens. 5. Of the 27 strains of nocardia isolated, 11 strains were N. transvalensis, 5 N. convoluta, 5 N. erythropolis, one N. vaccinii, one N. polychromogens-paraffinae complex and 4 untypable strains of orange-pigmented nocardia spp.

  • PDF

건설 현장에서 안전성 향상을 위한 지반진동.소음.비산먼지 측정자료의 분석에 관한 연구 -영남지역의 퇴적암.화성암층에서의 발파 및 항타작업을 중심으로- (A Study on Data Analysis of Ground Vibration.Noise Dust Dispersion Measurement for Enhancing Safety at the Construction Sites - Focussed on Blasting and Piling in Sedimentary and Igneous Rocks in the Youngnam Area -)

  • 안명석;류창하;박종남
    • 화약ㆍ발파
    • /
    • 제19권3호
    • /
    • pp.91-104
    • /
    • 2001
  • As in Korean environments with mountainous and hilly areas, the rock generally has to be removed in construction or civil engineering work in tunnelling or excavation for development in urban area. Explosives should be used for blasting, which may cause serious problems on local people for their claim for compensation due to ground vibration, noise. For safe and economic blasting, geology and engineering characteristics of rocks such as discontinuities of rock or weathering are very important factors, together with site characteristics for prediction of ground vibration. In this study, conducted were the detailed study for major rocks most widely distributed in the South-east area, in-situ geological survey, geological and geochemical analysis, and further laboratory uniaxial rock stress, seismic velocity of core samples together with in-situ seismic velocity measurements. Regulations on ground vibration and noise were reviewed for assessing their adaptabilities, and a total of 4,856 measured blasting vibration data were examined for enhancing the confidence level in estimating the predictive formulation using scaled distance statistically.

  • PDF

기초분리말뚝 공법의 설계기법 개발 (Development of Design Method of Disconnected Piled Raft Foundation System)

  • 최정인;민기훈;김성호;권오성;김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.691-699
    • /
    • 2008
  • In the design of a foundation, settlement of the foundation may exceed allowable design criteria even with a competent bearing stratum. In such a case, a piled-raft foundation system may be adopted using piles as settlement reducing component. In this paper, Disconnected Piled Raft Foundation (DPRF) system, which installs disconnected piles underneath the raft and uses the piles as ground reinforcements, is studied as a cost effective design method against the classical piled-raft foundation system. To this end, large size loading tests were carried out on weathered ground changing area replacement ratio and length of piles. The results indicated that the settlement of the reinforced ground was reduced by 34~87% and the allowable bearing pressure increased by 70% on average from those of the unreinforced original ground, respectively. The correlating formula between the area replacement ratio and the load bearing ratio of piles were derived from the test results and numerical analysis. From the correlation, a design method determining the size and the quantity of the disconnected piles to enhance the bearing capacity of original ground to the desired value was proposed based on one inch settlement criteria.

  • PDF