• Title/Summary/Keyword: Ground Water Level

Search Result 608, Processing Time 0.024 seconds

Evaluation of Stability of Slope with Granite Weathered Soil considering Rainfall Events (강우사상을 고려한 화강풍화토 비탈면의 안정성 평가)

  • Kim, Gyu-Hyeong;Hwang, Eui-Pil;Lee, Kang-Il
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.4
    • /
    • pp.421-429
    • /
    • 2018
  • Purpose: This study conducted a slope stability study considering changes in the ground water level due to rain phenomena and the duration of rainfall, that is for the purpose of analyzing the stability of the slope surface of the cut section, seepage numerical analysis is performed by height of slope and rainfall accident, and the characteristics of rainfall was applied reasonably in order to determine the slope change during rain by analyzing rainfall and rainfall pattern due to climate change. Results: As a result of numerical analysis of stability for slope composed of the granite weathered soils according to the characteristics of rainfall(Uniform Rainfall, US Army Corps., Huff's method - 1/4, 4/4), Conclusion: The higher the slope, the smaller the safety factor of the slope, the smaller the elevation of the ground water level as the rainwater seepage does not reach the underground water level. In addition, the ground water level was assessed to be rose significantly in condition of case 3 Huff's method - 1/4, rain pattern with the largest initial rainfall duration, and the safety factor was analyzed to be small.

A Study on Drainage Stability of Cable Tunnel (전력구 터널의 배수 안정성에 관한 연구)

  • 지현석;박준모;장연수;박정순
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.687-694
    • /
    • 2002
  • This paper presents the results of 3-D analysis on steady state flow in the region where the leakage in a cable tunnel is occurred due to high excess ground water pressure. In numerical modeling, a relief well is selected as a method of reduction in water pressure at the surrounding region of the cable tunnel. The distribution of ground water level after dewatering by relief wells is analyzed, Results show that the amount of dewatering level in the layer of hard rock is about 4.2∼8.6m, and that in the layer of fracture zone is about 5.8∼8.2m. The predicted settlement at the cable tunnel due to the increase of effective stress by dewatering is 0.3mm.

  • PDF

Forecasting Model for Flood Risk at Bo Region (보 지역 홍수 위험도 예측모형 연구)

  • Kwon, S.H.;Oh, H.S.
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.1
    • /
    • pp.91-95
    • /
    • 2014
  • During a flood season, Bo region could be easily exposed to flood due to increase of ground water level and the water drain difficulty even the water amount of Bo can be managed. GFI for the flood risk is measured by mean depth to water during a dry season and minimum depth to water and tangent degree during a flood season. In this paper, a forecasting model of the target variable, GFI and predictors as differences of height between ground water and Bo water, distances from water resource, and soil characteristics are obtained for the dry season of 2012 and the flood season of 2012 with empirical data of Gangjungbo and Hamanbo. Obtained forecasting model would be used for keep the value of GFI below the maximum allowance for no flooding during flooding seasons with controlling the values of significant predictors.

A Study on the Applicability of Bearing Capacity Formulas of Driven Pile by Comparison with the Results of Static Loading Tests (정재하시험 결과를 통한 타입말뚝 지지력 공식의 타당성 분석)

  • Chun, Byung-Sik;Lee, Seung-Beom
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.544-551
    • /
    • 2004
  • Piles are structural elements made of steel, concrete or timber, and utilize as pile foundation which is one of deep foundations. Driven pile among them, which drives pile into the ground, is fast-constructable, less expensive and it supplies much bearing capacity. For these reasons, its demand is steady. In this study, by selecting the cases which reached ultimate failure during in-situ static loading tests, bearing capacities acquired from these tests were compared with those computed by existing theories and formula. As the results of the analysis, ultimate bearing capacity computed by theoretic formula were less or similar to those of test results in most cases, but lower ground water level and more dense layer where end of piles were reached remarkably high bearing capacity in theoretical methods. ${\beta}-method$ and Korean structure foundation design standard were sensitive to ground physical properties. Meyerhof metbod and API code were relatively independent from site condition.

  • PDF

Groundwater Flow Analysis using Numerical model in Small Basin (소규모유역의 수치모헝을 이응한 지하수 유동해석)

  • 최윤영
    • Journal of Environmental Science International
    • /
    • v.12 no.6
    • /
    • pp.615-626
    • /
    • 2003
  • The applied model for this study area is WINFLOW using mite element method, It is thought that the simulation result by WINFLOW model under the steady flow state reflects well the ground water distribution within the reliability level which shows the error range of 1.1% to 8.0% from the comparison between the computed values and the observed, and analyzed that the constant head distribution is shown along the east-west direction and gentle and stable head gradient along the north-south direction. Ground water of the study area shows stable movement from the south to the stream area, and the particle trace for each location shows relatively linear shape from the upstream to the pumping location while the radius of influence according to the pumping amount shows a significant difference at the down stream area from the pumping location. The simultaneous pumping from P and P1 shows more complicated appearance, not the increase of the radius of influence than pumping from a single well P or P1, and it is analyzed that the particle path takes nearly linear form. It is known that the flow direction of the ground water and the velocity of the flow affect on the magnitude of the radius of influence of the wells from the fact that the more decreasing pattern of the ground water head is observed at the side of the well and the down stream area than the upstream area when the ground water moves from south to north regarding the radius of influence according to the pumping amount. Satisfactory results in analyses of ground water movement are obtained through the significant reduction of the physical uncertainties in the flow system as well as the relatively convenient model application using WINFLOW model which is proposed in this study.

국가 지하수 관측망 자료를 이용한 충적층 지하수 함양률의 공간적 변동성 연구

  • 문상기;우남칠;한원식
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.237-242
    • /
    • 2002
  • This study is objected to assess the recharges of phreatic aquifers in the south Korea. The water level data of the national ground-water monitoring network were analysed by PCA(Principal Component Analysis), and classified to 8 types. The recharge were estimated by ‘water-level change method’ on basis of the classified types and compared with the previous methods(hydrograph separation methods) on basis of 4 river basins. The recharge were various type by type and site by site. But the recharge estimated by this study were consistent with that of the other studies.

  • PDF

A Study on the Development of Hourly Evaporation Recording Instrument for Class A Pan (대형증발계용 매시간 증발 기록계 개발에 관한 연구)

  • Bu-Yong Lee
    • Journal of Environmental Science International
    • /
    • v.10 no.5
    • /
    • pp.323-327
    • /
    • 2001
  • A new method is developed to estimate the evaporation of water from a surface with high accuracy and resolution. The principle of new method is to detect a weight change of buoyant weight according to a change in water level of Class A Pan mesured by the use of a strain-gauge load cell. Field test of evaporation recording new instrument was carried out at Suwon for 10 days July 1999. It is possible in field observation to measure hourly evaporation amount by newly developed evaporation recording instrument in Class A Pan against strong solar radiation. Present study provide a possibility of domestic high accuracy instrument development below than 0.1mm water level measurement accuracy. If there is low humidity and high wind speed conditions which is possible to evaporate from water surface during night time. And it needs continuous study to understand between meteorological elements and latent heat effect at ground level by field observation study using high accuracy evaporation recording instrument.

  • PDF

Development of Measuring Method for Bridge Scour and Water Level Using Temperature Difference Between Medium Interfaces (매질 경계면의 온도 변화를 이용한 교량 세굴 및 수위 측정방법 개발)

  • Joo, Bong-Chul;Park, Ki-Tae;You, Young-Jun;Hwang, Yoon-Koog
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.126-133
    • /
    • 2014
  • The main source of bridge destruction is due to scour. The bridge scour is the result of erosive action of flowing water taking away ground materials from near the abutment or pier. Furthermore, the water level must be also monitored whiling flooding, because it dangers not only the stability of bridge itself, but the safety of bridge users. This study is intended to develop a new measuring system for bridge scour by overcoming the current limitation of scour measurement technique. This measuring system is confirmed its excellence and validity through this study. The newly developed measuring system finds the distance between the water surface and the ground surface by detecting temperature difference along the abutment vertically. The measuring mechanism for monitoring the bridge scour and water level is based on identifying the temperature difference among mediums, including air, water and ground. In order to validate the new measuring system, the lab experiments and the field tests are conducted and compared. It has been confirmed that this system can effectively measure the bridge scour and the water level by analyzing the temperature distribution between mediums and the temperature variation over time.

A Study of Artesian Characteristics in Yangsan/Mulgeum Site (양산물금지구 피압수 특성에 관한 연구)

  • 한영철;유갑용
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.123-130
    • /
    • 1999
  • This paper presents a study of geotechnical treatment for artesian pressure after extensive investigation was performed on the distribution and characteristics of artesian condition which exists at Yangsan/Mulgeurn site. The result of analysis indicates that the artesian pressure seems to be up to 2.9M above the existing ground surface, originating from the higher ground water recharging sources in the surrounding hills and mountains. There is no harmful effect after the site development since the height of embankment is more than 4M above the existing ground surface.

  • PDF

A Study on Settlement Characteristics of Earthwork Subgrade with Lowering the Groundwater in High-speed Railway (지하수위 저하에 따른 고속철도 토공노반 침하특성에 관한 연구)

  • Kim, Young-Ha;Eum, Ki-Young;Han, Sang-Jae;Park, Yong-Gul;Jung, Jae-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.5
    • /
    • pp.67-74
    • /
    • 2015
  • Unlike the primary consolidation settlement, the settlement of ground water lowering is not considered separately because of relatively small residual settlement. But the allowed residual settlement (30 mm) of the concrete track in the high-speed railway may be exceeded due to unexpected excessive ground water lowering. This study analyzed the effect of the settlement according to the ground water level change using finite element analysis of stress-pore pressure coupling model, and compared the analysis results with the measured data. As a result, the range of elasticity modulus satisfying the allowable settlement was proposed, and it is suggested that settlement due to ground water level changes should be reflected in the design.