• Title/Summary/Keyword: Ground Plate

Search Result 444, Processing Time 0.025 seconds

Study on the Midwater Trawl Available in the Korean Waters - III (한국근해에 있어서의 중층트로올의 연구 - III)

  • 이병기
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.1
    • /
    • pp.1-5
    • /
    • 1987
  • The authors carried out an experiment to determine the vertical opening of the midwater trawl, which is the same used in the former experiment in this series of studies. To determine the vertical opening of otter board and front weight, three fish finders were used. A 200 KHz fish finder set on board the research vessel was used to sound the depth of water. A transmitter of 50 KHz fish finder was set through the shoe plate of otter board to determine the height of otter board from the sea bed, and a transmitter of another 50 KHz fish finder was set downwardly on the net pendant right before the front weight to determine the height of weight from the sea bed. The depth of otter board and weight were calculated by subtract the height of those from the depth of water, respectively. To determine the vertical opening of mouth, a transmitter of net recorder was set on the head rope and the vertical opening of that to ground rope was directly read on the recording paper. The results obtained can be summarized as follows: 1. The rate of the depth of otter board to the length of warp was in the range of 0.44 to 0.25, and the depth was linearly shoaled about 5m per 0.1m/sec of the towing speed or per 20rpm of the main engine. The rate of the observed depth to the calculated depth of otter board was in the range of 0.92 to 0.080 with a decreasing tendancy in accordance with the increase of towing speed. 2. The depth of head rope was 2 to 3m deeper than that of otter board, and the vertical opening of net mouth was in the range of 22 to 19m, with a decreasing tendancy in accordance with the increase of towing speed, 3. The difference of depth between front weight and otter board was about 20m and 22m respectively in the length of warp 100m and 150m without distinct change in accordance with the towing speed. The depth of front weight was 2 to 3m shallower than that of ground rope. 4. The changing range of depth of head rope according to the revolution of main engine was about 4m per 20rpm.

  • PDF

Design of Microstrip Patch Antenna using Inset-Fed Layered for Metallic Object in u-Port (U-항만 환경에서 금속부착을 위한 인셋 급전 마이크로패치 안테나 설계)

  • Choi, Yong-Seok;Seong, Hyeon-Kyeong
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.2
    • /
    • pp.80-85
    • /
    • 2015
  • In this paper, we present, an indstrial RFID layered microstrip patch antenna is designed using an inset feed method in order to improve recognition rates in a long distance as tags are attached to metal object by improving a problem of feeding power in fabricating metal tags and reducing effects of metallic object. The inset feed shows a distinctive characteristic that has no separation between emitters and feed lines differing from a structure with the conventional inductive coupling feed. This structure makes possible to produce a type that presents a low antenna height and enables impedance coupling for tag chips. Although it shows a difficulty in the impedance coupling due to increases in the parasite capacitance between a ground plane and an emitter in an antenna according to decreases in the height of a tag antenna, it may become a merit in designing the tag antenna because the antenna impedance can be determined as an inductive manner if a shorted structure is used for feeding power. Therefore, in this paper the microstrip patch antenna is designed as a modified type and applies the inset feed in order to reduce effects of metallic objects where the antenna is be attached. Also, the antenna uses a multi-layer structure that includes a metal plate between radiator and ground instead of using a single layer.

A Study of Standardization of Detecting Abnormal Data by Front Weed's Shadow Effect in over 100 kW Photo Voltaic Power Generation Unit (100 kW 이상의 태양광 발전단위에서 전방 잡초 그림자 영향 분석에 의한 비정상 데이터 표준화 연구)

  • Kim, Hong Myeong;Lee, Yu Ri;Jung, Jae hak
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.416-423
    • /
    • 2020
  • Majority of over 100 kW capacity photo voltaic (PV) power generation system was constructed on the plate ground of soil. Rarely PV system installed on concrete or building but it usually be under 25 kW capacity. On the soil ground the weeds growen up and it's shadow influenced to decrease of amount of PV power generation. This work analysis the weeds shadow's effect to decrease of PV power generation with 100 kW capacity of real PV power generation system in Yeungnam University, Finally the weed shadow"s influence value through the real field monitoring Data is suggested for give a standard management time of weeds to avoid the negative influence on whole power plant. Moreover the hot spot which is generated by long term partial shallow on PV module also can detected with the result of this work. It also suggested as a standard value of monitoring Data.

A Study on the Role and Transition of the Tapgu in Stone Pagoda (석탑 탑구(塔區)의 역할 및 변천에 관한 연구)

  • Chung, Hae-Doo;Jang, Suk-Ha
    • Journal of architectural history
    • /
    • v.19 no.1
    • /
    • pp.91-104
    • /
    • 2010
  • Korea's stone buildings are varied in their types such as stone pagodas, stone lanterns, stone bridges, stoneworks, etc. These account for more than 30% over the entire cultural properties, but research achievements are lacking compared to wooden buildings. Accordingly, this study aims to identify the shape, role and transition of Tapgu, which had been used to set up boundary at a stone pagoda, one of the stone buildings. The 20th stone pagodas, which have relative accuracy in its forming year, have been studied around national treasure or treasure between 7th century and 9th century. There are a lot of different opinions about the role and meaning of Tapgu, and at this writer's option, Tapgu is defined as follows: First, each structure plays a different role. A structure to pass the load in the upper part to the ground can be seen as a stair or a pedestal, but a structure to form double foundations can be considered as Tapgu. Second, Tapgu can be used to divide areas with stones or stepping stones. As a result, the shape, role and transition of Tapgu is as follows: Firstly, when it comes to its shape, Tapgu includes flagstone type, belt type, double foundation type, compound type. Flagstone type had been used to set up boundary at stone pagodas by using foundation stone, belt type by keeping apart from stone pagodas, and double foundation stone by installing dual foundation stones. Secondly, Tapgu is considered to set up boundary in the case of flagstone and plate stone, and acts like a structure which can prevent surrounding area of stone pagoda from coming up while being stuck around stone pagodas. Belt type was installed only for the purpose of forming boundary. At the bottom, double foundation stone had been used to pass the load in the upper part to the ground in the same way as the foundation stone in the upper part, and the boundaries were set varying the size. Thirdly, when it comes to the transition of Tapgu, flagstone type of boundary stone had been installed in the 7th century, and belt type of boundary stone had been mainly installed in the 8th century. And double foundation stone had been installed in the 9th century. Comprehensively, flagstone type and belt type had been made around the 7th and 8th century when Tapgu was regarded important and stone pagoda started to be built. At the turn to the 9th century, the role of Tapgu had been increasingly losing in the construction of stone pagoda, and foundation stone started to appear.

Improvement of Shallow Soil Using Electric Heating Equipment (전기가열장치를 이용한 표층지반개량)

  • Park, Min-Cheol;Im, Eun-Sang;Shin, Beck-Chul;Han, Heui-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.10
    • /
    • pp.41-54
    • /
    • 2012
  • This paper is to develop the method of surface soil improvement by electric heating equipment. For this purpose, the electric heating systems were invented to apply to the in-situ soil. Iaboratory tests were done to study the behaviors of sea clays by eletric heating. In lab tests, two different heating temperatures, $70^{\circ}C$ and $110^{\circ}C$, were applied to the saturated clays to examine the relationship between evaporation and compaction. In addition, trafficability was analyzed to the heated by applying cone penetrometer to the heated clays Furthermore, in-situ tests were conducted to analyze the range of soil improvement and strength variations. The temperature changes in field were measured and they were compared with those of the commercial program (Temp/W). Also, the bearing capacities of electrically heated field were tested by PBT (plate bearing test). Several conclusions were derived from the results of the numerical analysis and tests (lab and field). The improvement ranges and strength variations of electrically heated soil depended on the heating temperature and time. If the heating temperature is more than $100^{\circ}C$ evaporating the ground water, the bearing capacity and settlement increased rapidly. The bearing capacities of in-situ soil increased more than 3 times, and heated soil emitted a lot of vapors. The soil around electric heater was sintered completely, and its range was almost 20 cm.

Comparison of Safety Margin of Shallow Foundation on Weathered Soil Layer According to Design Methods (설계법에 따른 풍화토 지반 얕은기초의 안전여유 비교)

  • Kim, Donggun;Hwang, Huiseok;Yoo, Namjae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.12
    • /
    • pp.55-64
    • /
    • 2016
  • In this paper bearing capacity and safety margin of shallow foundation on weathered soil ground against shear failure by using current design method of allowable stress design (ASD), load resistance factor design (LRFD) based on reliability analysis and partial safety factor design (PSFD) in Eurocode were estimated and compared to each other. Results of the plate loading test used in construction and design were collected and analysis of probability statistics on soil parameters affecting the bearing capacity of shallow foundation was performed to quantify the uncertainty of them and to investigate the resistance bias factor and covalence of ultimate bearing capacity. For the typical sections of shallow foundation in domestic field as examples, reliability index was obtained by reliability analysis (FORM) and the sensitivity analysis on soil parameters of probability variables was performed to investigate the effect of probability variable on shear failure. From stability analysis for these sections by ASD, LRFD with the target reiability index corresponding to the safety factor used in ASD and PSDF, safety margins were estimated respectively and compared.

A Study on the Lateral Flow in Polluted Soft Soils (오염된 연약지반의 측방유동에 관한 연구)

  • 안종필;박상범
    • The Journal of Engineering Geology
    • /
    • v.11 no.2
    • /
    • pp.175-190
    • /
    • 2001
  • This study investigates the existing theoretical backgrounds in order to examine the behavior of lateral flow according to the plasticity of soils when unsymmetrical surcharge is worked on polluted soft soils by comparing and analyzing the results measured through model tests. Model tests are canied out as follows soil tank, bearing frame and bearing plate are made. By increasing unsymmetrical surcharge to the ground soils with the consistent water content and with gradually increased polluted materials at intervals, the amounts of settlement, lateral displacement and upheaval were respectively observed. In conclusion, the value of critical surcharge was expressed as q$_{cr}$=2.78$_{cu}$ which was similar to those Tschebotarioff(q$_{cr}$=3.0$_{cu}$) and Meyerhof(q$_{cr}$=(B/2H+$\pi$/2)$_{cu}$) had been proposed. The value of ultimate capacity was expressed as q$_{ult}$=4.84$_{cu}$ which was similar to that of Prandtl. The lateral flow pressure is adeQuately calculated by the eQuation(P$_{max}$=K$_o$ r H) and the maximum value of lateral flow pressure is found near O.3H of layer thickness(H) and is higher to ground surface than the ones in composition pattern, Poulos distribution pattern and softclay soils (CL, CH) which is not polluted. The stability control method used in this research followed the management diagram of Tominaga.Hashimoto, Shibata.Sekiguchi, Matsuo.Kawamura who use the amounts of plasticity displacement by lateral flow. As a result, the ultimate capacity values in the diagram {S$_v$-(Y$_m$/S$_v$)} of Matsuo.Kawamura and in the diagram {(q/Y$_m$)-q} of Shibata. Sekiguchi were smaller than in the ones of load-settlement curve (q-S$_v$).

  • PDF

Deformation of segment lining and behavior characteristics of inner steel lining under external loads (외부 하중에 따른 세그먼트 라이닝 변형과 보강용 내부 강재 라이닝의 거동 특성)

  • Gyeong-Ju Yi;Ki-Il Song
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.26 no.3
    • /
    • pp.255-280
    • /
    • 2024
  • If there are concerns about the stability of segment lining due to section deficiency or large deformation in shield TBM tunnel, reinforcement can be done through ground grouting outside the tunnel or by using steel plate reinforcement, ring beam reinforcement, or inner double layer lining inside the tunnel. Traditional analyses of shield TBM tunnels have been conducted using a continuum method that does not consider the segmented nature of segment lining. This study investigates the reinforcement mechanism for double layer reinforced sections with internal steel linings. By improving the modeling of segment lining, this study applies Break-joint mode (BJM), which considers the segmented characteristics of segment lining, to analyze the deformation characteristics of double layer reinforced sections. The results indicate that the existing concrete segment lining functioned similarly to ground reinforcement around the tunnel, rather than distribution the load. In general, both the BJM model considering the segmentation of segment lining and the continuum rigid method were similar deformation shapes and stress distributions of the lining under load. However, in terms of deformation, when the load strength exceeded the threshold, the deformation patterns of the two models differed.

Moisture and Heat Transfer Characteristics of Waterproof and Water Vapor Permeable Coated Fabrics (기능성 투습방수 코팅포의 수분 및 열전달 특성)

  • Cho, Ji-Hyun;Ryu, Duck-Hwan
    • Korean Journal of Human Ecology
    • /
    • v.8 no.1
    • /
    • pp.151-163
    • /
    • 1999
  • The purpose of this study was to investigate the thermal resistance and the liquid/vapor water transfer characteristics of four waterproof and water vapor permeable coated fabrics with the ground fabric called nylon taffeta. In order to establish the experimental environment, outdoor temperature and humidity in Taegu during the last three years were examined and the experiment was performed at (1) $15^{\circ}C$, 50% R.H., (2) $20^{\circ}C$, 60% R.H., (3) $25^{\circ}C$, 65% R.H., which were the average standards in spring and fall. The test results were as follows ; 1. Among physical parameters, the thinner the thickness was, the higher the water vapor permeability was. But the porosity in thickness was not proportional to water vapor permeability linearly. 2. The thicker the thickness of specimens was and the smaller the bulk density and porosity were, the higher the thermal resistance. And the results also shown that the larger the temperature difference between the environmental temperature and the hot plate was, the more the difference of CLO values was apparent. 3. Since the contact angle of all specimens are above $90^{\circ}$, the all specimens have a good performance in waterproof. The more the specimens surface were rough, the higher the thermal resistance was. 4. According to the result of performing moisture transfer test using the simulating body skin-clothing-environment system, the humidity sensor placed in between the fabric and the environment detected the full saturation in 10 minutes after the experiment had began at $15^{\circ}C$, 50% R.H. and in 15 minutes after the experiment both at $20^{\circ}C$, 60% R.H. and at $25^{\circ}C$, 65% R.H. 5. ${\Delta}$ values of the humidity sensors placed in between the human body and the fabric and in between the fabric and the environment fluctuated repeatedly within the range of $20{\sim}40%$ at $20^{\circ}C$, 60% R.H., and $15{\sim}30%$ at $25^{\circ}C$, 65% R.H.

  • PDF

Comparison of Lower Extremity Kinematics and Kinetics during Downhill and Valley-shape Combined Slope Walking

  • Jeong, Jiyoung;Shin, Choongsoo S.
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.2
    • /
    • pp.161-166
    • /
    • 2016
  • Objective: The purpose of this study was to determine the knee and ankle joint kinematics and kinetics by comparing downhill walking with valley-shape combined slope walking. Method: Eighteen healthy men participated in this study. A three-dimensional motion capture system equipped with eight infrared cameras and a synchronized force plate, which was embedded in the sloped walkway, was used. Obtained kinematic and kinetic parameters were compared using paired two-tailed Student's t-tests at a significance level of 0.05. Results: The knee flexion angle after the mid-stance phase, the mean peak knee flexion angle in the early swing phase, and the ankle mean peak dorsiflexion angle were greater during downhill walking compared with valley-shape combined slope walking (p < 0.001). Both the mean peak vertical ground reaction force (GRF) in the early stance phase and late stance phase during downhill walking were smaller than those values during valley-shape combined slope walking. (p = 0.007 and p < 0.001, respectively). The mean peak anterior GRF, appearing right after toe-off during downhill walking, was also smaller than that of valley-shape combined slope walking (p = 0.002). The mean peak knee extension moment and ankle plantar flexion moment in late stance phase during downhill walking were significantly smaller than those of valley-shape combined slope walking (p = 0.002 and p = 0.015, respectively). Conclusion: These results suggest that gait strategy was modified during valley-shape combined slope walking when compared with continuous downhill walking in order to gain the propulsion for lifting the body up the incline for foot clearance.