• 제목/요약/키워드: Ground Measurement

검색결과 1,548건 처리시간 0.029초

광대역 접지임피던스 측정기의 설계

  • 박대원;장운용;차현규;길경석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.26-26
    • /
    • 2010
  • Line to ground faults or lightning strikes in electrical power systems produce high frequency overvoltages. With this reason, a wide band analysis of the ground impedance is necessary. In the paper, design of a wideband ground impedance meter which can measure the ground impedance in ranges from 65 Hz to 1.5 MHz is described. Also, a noise elimination method by a digital band-pass filter during measurement is proposed. The maximum measurement error of the meter is estimated 3 % in full ranges.

  • PDF

회로모델을 이용한 봉상전극 접지임피던스의 분석 (Analysis of Ground Impedance of a Ground Rod Using Circuit Models)

  • 이복희;이태형;엄주홍
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.95-99
    • /
    • 2004
  • A systematic approach of measurement, modeling and analysis of grounding system impedance in the field of lightning protection systems is presented. The measurement and analysis of ground impedance are based on a computer aided technique. The magnitude and phase of ground impedance were measured and analyzed by the modified fall-of-potential method and the proposed computer program algerian using the waveforms of the test current and potential rise. The theoretical analysis of ground impedance were performed with the equivalent circuit models, and the theoretical results were compared with the measured data.

  • PDF

접지임피던스 측정에 관한 전류보조전극 거리 및 주파수의 영향 분석 (Analysis for Ground Impedance Measurement Influenced by Distance of Current Probe and Frequency)

  • 길형준;김동우;김동욱;이기연;문현욱;김향곤
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.289-292
    • /
    • 2009
  • This paper describes the analysis for ground impedance measurement influenced by distance of current probe and frequency using the fall-of-potential method and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position of auxiliary probes. In order to analyze the effects of ground impedance due to the distance of the current probe and frequency, ground impedances were measured in case that the distance of current probe was located from 5[m] to 20[m] and the measuring frequency was ranged in 55[Hz], 128[Hz], 342[Hz], and 513[Hz]. The results could be help to determine the position of current probe when the ground impedance was measured at grounding system.

  • PDF

접지계에서 위험전압의 측정과 분석 (Measurement and Analysis of Risk Voltages in a Grounding System)

  • 진창환;박대원;서재석;길경석;길형준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.3099-3103
    • /
    • 2011
  • In measurement of risk voltages; the step and touch voltage, the distance between the current electrode and the ground electrode recedes up to several hundred meters as the scale of grounding system increases. This paper dealt with the measurement method of risk voltage in a restricted space. The risk voltage was analyzed depending on the distance and the direction of the current electrode from the ground electrode in a $10[m]{\times}10[m]$ mesh grounding system. The average value of risk voltages measured at a point 20 [m] away from the current electrode was deviated below 5 [%] from that measured at 100 [m] point. Consequently, the evaluation of risk voltage of a large-scale grounding system buried in a spatially restricted place is available if the current electrode is installed in symmetry to the ground electrode.

  • PDF

열차운행에 따른 철도역사의 진동영향 평가 (The Vibrational Evaluation of Railway Station by the Train Service)

  • 김병삼;이태근
    • 한국소음진동공학회논문집
    • /
    • 제20권10호
    • /
    • pp.968-975
    • /
    • 2010
  • The high interest for the ground vibrations which is caused by the train service is risen. When the trains are passed, a serious force is applied to ground and the caused vibration is propagated to the area of the building by the ground and rocks. This vibration comes to feel in the residents with the direct vibration, it is radiated in sound. The caused vibration and radiated sound affect the human's life, and this vibration brings about the operation interruption of the equipment which is sensitive to the vibration, or will bring about the structural damage of the building. In this study, the effect of the vibrations caused by the passing trains on the railway station and buildings is investigated by vibration measurement. Indoor and outdoor measurement is carried out by each trains.

전류 및 전위 측정선간 상호유도가 접지임피던스에 미치는 영향 (The Effect of Mutual Coupling between Current and Potential Test Leads on Ground Impedance)

  • 엄주홍;조성철;이태형
    • 전기학회논문지
    • /
    • 제57권7호
    • /
    • pp.1223-1228
    • /
    • 2008
  • While a high frequency source is used for measuring the ground impedance, there are several factors having an effect on the measured value. A primary factor of the measurement error is the ac mutual coupling between current and potential test leads. The mutual coupling causes the test current to induce a voltage into the potential test lead that adds to the actual ground potential rise and produces a significant measurement error as the length of the test leads paralleled is prolonged. In order to avoid the mutual coupling, it is recommended that the ground impedance be measured by angled arrangement of test leads. The mutual impedance due to the inductive coupling with an angle of $90^{\circ}$ was calculated at $0^{\circ}$ by Campbell/Foster Method. With an angle of $180^{\circ}$, the mutual impedance was calculated large value enough to introduce a fairly large margin of error, however, the measured value of ground impedance was close to the value at $90^{\circ}$.

연약점토층위 이층지반 지표면 재하시 지중응력 특성연구 (A Study on the Distribution Stresses beneath Loaded Ground Surface Area of Double Strata Ground on Soft Clay Layers)

  • 이인형;임종석
    • 한국농공학회논문집
    • /
    • 제47권6호
    • /
    • pp.47-57
    • /
    • 2005
  • Stress distribution in soils is the very important element to design and to solve the problems of settlement, safety of foundations and trafficability of constructing vehicle in civil engineering. This research presents the comparative estimation of the actual and theoretical measurement on the underground stress of outer layer for each soil after the observation of each top soil layer fur its vertical and horizontal stresses in (1) homogeneous sand ground (2) weak stratum with the sand soil (3) weak stratum with gravel of the soil model, and it also investigates the effect of subsidence of ground by the repeated load. The underground stresses fumed out to be different in the value of theoretical and actual measurement after the trial examination of model. This study has the purpose of suggesting the better construction method of running equipment on weak stratum by comparing the estimated value of trial experiment and theory on underground stress of the weak ground surface area and of raising up the necessity of the continuous research hereafter.

하이브리드 지중열교환기 적용 지열 히트펌프 시스템의 난방 성능 분석 (Heating Performance Analysis of Ground-Source Heat Pump (GSHP) System using Hybrid Ground Heat Exchanger (HGHE))

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권3호
    • /
    • pp.8-16
    • /
    • 2020
  • This paper presents the heating performance analysis results of a ground-source heat pump (GSHP) system using hybrid ground heat exchanger (HGHE). In this paper, the HGHE refers to the ground heat exchanger (GHE) using both a surface water heat exchanger (SWHE) and a vertical GHE. In order to evaluate the system performance, we installed monitoring sensors for measuring temperatures and power consumption, and then measured operation data with 4 different load burdened ratios of the HGHE. During the entire measurement period, the average heating capacity of the heat pump was 37.3 kW. In addition, the compressor of the heat pump consumed 9.4 kW of power, while the circulating pump of the HGHE used 6.7 kW of power. Therefore, the average heating coefficient of performance (COP) for the heat pump unit was 4.0, while the system including the circulating pump was 2.7. Finally, the parallel use of SWHE and VGHE was beneficial to the system performance; however, further researches are needed to optimize the design data for various load ratios of the HGHE.

하이브리드 지중열교환기 적용 히트펌프 시스템의 냉방 성능 분석 (Cooling Performance Analysis of Ground-Source Heat Pump (GSHP) System with Hybrid Ground Heat Exchanger (HGHE))

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.43-52
    • /
    • 2018
  • This paper presents the cooling performance analysis results of a ground-source heat pump (GSHP) system using hybrid ground heat exchanger (HGHE). In this paper, the HGHE refers to the ground heat exchanger (GHE) using both a vertical GHE and a surface water heat exchanger (SWHE). In order to evaluate the system performance, we installed monitoring sensors for measuring temperatures and power consumption, and then measured operation data with 4 different load burdened ratios of the hybrid GHE, Mode 1~Mode 4. The measurement results show that the system with HGHE mainly operates in Mode 1 and Mode 2 over the entire measurement period. The average cooling coefficient of performance (COP) for heat pump unit was 5.18, while the system was 2.79. In steady state, the heat pump COP was slightly decreased with an increase of entering source temperature. In addition, the parallel use of SWHE and VGHE was beneficial to the system performance; however, further research are needed to optimize the design data for various load ratios of the HGHE.

통신 케이블 쉬스 층 접지가 전력선 전자유도 전압 측정에 미치는 영향 (Effect of the Sheath Layer Ground of Telecommunication Cable to Induced Voltage Measurement)

  • 이상무
    • 한국산학기술학회논문지
    • /
    • 제16권1호
    • /
    • pp.713-719
    • /
    • 2015
  • 통신 회선에 대한 전력선 전자유도 전압을 측정할 때, 일반 통신 케이블의 쉬스 층 및 측정 대상 통신 회선 접지의 상호 접속 관계에 따른 전압 변화를 비교 분석하였다. 케이블 양측 쉬스 접지 저항이 평균 $42.6{\Omega}$으로 유사한 상태에서 쉬스를 분리 접지하고 유도 전압을 측정하면 쉬스 접지를 하지 않은 상태에서 측정한 유도 전압에 대하여 10 % 미만 감소된다. 어느 한 쪽을 공통으로 접지하면 약 50 % 감소되고 양측을 모두 공통으로 하면 90 % 넘게 감소된다. 이것은 국제전기통신연합(ITU)에서 제공하는 계산식으로 계산하였을 때의 결과와 유사한 것으로 분석되었다. 아울러 ITU의 계산식을 활용하여 양측 쉬스 접지 저항 값을 변화시킬 때의 유도 전압 변화를 시뮬레이션하여 비교 분석한 결과, 실제 현장에서 쉬스 접지 저항 기준이 $100{\Omega}$이고 전화 국사의 저항이 보통 $10{\Omega}$ 이하인 점을 감안할 때 측정 오차율은 약 10 % 이하가 된다.