• Title/Summary/Keyword: Ground Equipment

Search Result 742, Processing Time 0.02 seconds

Identify the Type of Exercise to Prevent Falls for Healthy Elderly Life (고령자의 건강한 삶을 위한 낙상 예방 운동유형 확인)

  • Park, Yang-Sun;Kim, Mi-Ye;Park, Seong-Won;Lee, Ok-Jin
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.7
    • /
    • pp.361-373
    • /
    • 2019
  • Falls are a threat to the physical health of the elderly as well as to their overall quality of life. The purpose of this study was to identify which type of exercise is effective for improving the balance of the elderly, and to obtain the basic data for developing the falls prevention exercise intervention program for the elderly. We compared to the differential effects between rhythmic step exercise and core muscle strengthening exercise in terms of functional balance test and self-reported balance test. Women older than 65 years and under 80 years of age were assigned to one of the step exercise group(21), core muscle exercise group(20), and control group(21), and for 8 weeks, twice per week, 20-30 minutes of exercise were treated. All participants performed one foot static balance test with open and closed eyes. And they responded to self-reported balance test, such as Fall Efficacy Scale(FES) and Activities-specific Balance Confidence(ABC) Scale. The results of statistical analysis are summarized as follows. First, rhythmic stepping exercise was more effective in improving functional balance than core muscle strengthening exercise. In particular, the effect of step exercise was obvious in the one-foot static balance test with open eyes. Second, the self-reported balance test showed better step exercise than core muscle exercise. Specifically, rhythmic step exercise was more effective in enhancing fall efficacy than core muscle exercise. In conclusion, the rhythmic step exercise was more effective in improving the balance ability of the elderly than the core muscle exercise. The rhythmic step exercise is more related to the lower extremity muscles, and especially since the rhythmic step exercise is performed in various ground changes, it seems to have a high similarity to the fall occurrence situation. For future research, we recommended the development of task-oriented ankle proprioceptive exercise intervention program and exercise equipment based on the specific motion situation in which the fall accident occurs in the elderly.

Evaluation of Proper Image Acquisition Time by Change of Infusion dose in PET/CT (PET/CT 검사에서 주입선량의 변화에 따른 적정한 영상획득시간의 평가)

  • Kim, Chang Hyeon;Lee, Hyun Kuk;Song, Chi Ok;Lee, Gi Heun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.22-27
    • /
    • 2014
  • Purpose There is the recent PET/CT scan in tendency that use low dose to reduce patient's exposure along with development of equipments. We diminished $^{18}F$-FDG dose of patient to reduce patient's exposure after setting up GE Discovery 690 PET/CT scanner (GE Healthcare, Milwaukee, USA) establishment at this hospital in 2011. Accordingly, We evaluate acquisition time per proper bed by change of infusion dose to maintain quality of image of PET/CT scanner. Materials and Methods We inserted Air, Teflon, hot cylinder in NEMA NU2-1994 phantom and maintained radioactivity concentration based on the ratio 4:1 of hot cylinder and back ground activity and increased hot cylinder's concentration to 3, 4.3, 5.5, 6.7 MBq/kg, after acquisition image as increase acquisition time per bed to 30 seconds, 1 minute, 1 minute 30 seconds, 2 minute, 2 minutes 30 seconds, 3 minutes, 3 minutes 30 seconds, 4 minutes, 4 minutes 30 seconds, 5 minutes, 5 minutes 30 seconds, 10 minutes, 20 minutes, and 30 minutes, ROI was set up on hot cylinder and back radioactivity region. We computated standard deviation of Signal to Noise Ratio (SNR) and BKG (Background), compared with hot cylinder's concentration and change by acquisition time per bed, after measured Standard Uptake Value maximum ($SUV_{max}$). Also, we compared each standard deviation of $SUV_{max}$, SNR, BKG following in change of inspection waiting time (15minutes and 1 hour) by using 4.3 MBq phantom. Results The radioactive concentration per unit mass was increased to 3, 4.3, 5.5, 6.7 MBqs. And when we increased time/bed of each concentration from 1 minute 30 seconds to 30 minutes, we found that the $SUV_{max}$ of hot cylinder acquisition time per bed changed seriously according to each radioactive concentration in up to 18.3 to at least 7.3 from 30 seconds to 2 minutes. On the other side, that displayed changelessly at least 5.6 in up to 8 from 2 minutes 30 seconds to 30 minutes. SNR by radioactive change per unit mass was fixed to up to 0.49 in at least 0.41 in 3 MBqs and accroding as acquisition time per bed increased, rose to up to 0.59, 0.54 in each at least 0.23, 0.39 in 4.3 MBqs and in 5.5 MBqs. It was high to up to 0.59 from 30 seconds in radioactivity concentration 6.7 MBqs, but kept fixed from 0.43 to 0.53. Standard deviation of BKG (Background) was low from 0.38 to 0.06 in 3 MBqs and from 2 minutes 30 seconds after, low from 0.38 to 0 in 4.3 MBqs and 5.5 MBqs from 1 minute 30 seconds after, low from 0.33 to 0.05 in 6.7 MBqs at all section from 30 seconds to 30 minutes. In result that was changed the inspection waiting time to 15 minutes and 1 hour by 4.3 MBq phantoms, $SUV_{max}$ represented each other fixed values from 2 minutes 30 seconds of acquisition time per bed and SNR shown similar values from 1 minute 30 seconds. Conclusion As shown in the above, when we increased radioactive concentration per unit mass by 3, 4.3, 5.5, 6.7 MBqs, the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the same way, in the change of inspection waiting time (15 minutes and 1 hour), we could find that the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the result of this NEMA NU2-1994 phantom experiment, we found that the minimum acquisition time per bed was 2 minutes 30 seconds for evaluating values of fixed $SUV_{max}$ and SNR even in change of inserting radioactive concentration. However, this acquisition time can be different according to features and qualities of equipment.

  • PDF