• Title/Summary/Keyword: Gross Errors

Search Result 44, Processing Time 0.018 seconds

Daily Setup Uncertainties and Organ Motion Based on the Tomoimages in Prostatic Radiotherapy (전립선암 치료 시 Tomoimage에 기초한 Setup 오차에 관한 고찰)

  • Cho, Jeong-Hee;Lee, Sang-Kyu;Kim, Sei-Joon;Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.99-106
    • /
    • 2007
  • Purpose: The patient's position and anatomy during the treatment course little bit varies to some extend due to setup uncertainties and organ motions. These factors could affected to not only the dose coverage of the gross tumor but over dosage of normal tissue. Setup uncertainties and organ motions can be minimized by precise patient positioning and rigid immobilization device but some anatomical site such as prostate, the internal organ motion due to physiological processes are challenge. In planning procedure, the clinical target volume is a little bit enlarged to create a planning target volume that accounts for setup uncertainties and organ motion as well. These uncertainties lead to differences between the calculated dose by treatment planning system and the actually delivered dose. The purpose of this study was to evaluate the differences of interfractional displacement of organ and GTV based on the tomoimages. Materials and Methods: Over the course of 3 months, 3 patients, those who has applied rectal balloon, treated for prostatic cancer patient's tomoimage were studied. During the treatment sessions 26 tomoimages per patient, Total 76 tomoimages were collected. Tomoimage had been taken everyday after initial setup with lead marker attached on the patient's skin center to comparing with C-T simulation images. Tomoimage was taken after rectal balloon inflated with 60 cc of air for prostate gland immobilization for daily treatment just before treatment and it was used routinely in each case. The intrarectal balloon was inserted to a depth of 6 cm from the anal verge. MVCT image was taken with 5 mm slice thickness after the intrarectal balloon in place and inflated. For this study, lead balls are used to guide the registration between the MVCT and CT simulation images. There are three image fusion methods in the tomotherapy, bone technique, bone/tissue technique, and full image technique. We used all this 3 methods to analysis the setup errors. Initially, image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours and then the radiation therapist registered the MVCT images with the CT simulation images based on the bone based, rectal balloon based and GTV based respectively and registered image was compared with each others. The average and standard deviation of each X, Y, Z and rotation from the initial planning center was calculated for each patient. The image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours. Results: There was a significant difference in the mean variations of the rectal balloon among the methods. Statistical results based on the bone fusion shows that maximum x-direction shift was 8 mm and 4.2 mm to the y-direction. It was statistically significant (P=<0.0001) in balloon based fusion, maximum X and Y shift was 6 mm, 16mm respectively. One patient's result was more than 16 mm shift and that was derived from the rectal expansions due to the bowl gas and stool. GTV based fusion results ranging from 2.7 to 6.6 mm to the x-direction and 4.3$\sim$7.8 mm to the y-direction respectively. We have checked rotational error in this study but there are no significant differences among fusion methods and the result was 0.37$\pm$0.36 in bone based fusion and 0.34$\pm$0.38 in GTV based fusion.

  • PDF

Development of a Biophysical Rice Yield Model Using All-weather Climate Data (MODIS 전천후 기상자료 기반의 생물리학적 벼 수량 모형 개발)

  • Lee, Jihye;Seo, Bumsuk;Kang, Sinkyu
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.5_2
    • /
    • pp.721-732
    • /
    • 2017
  • With the increasing socio-economic importance of rice as a global staple food, several models have been developed for rice yield estimation by combining remote sensing data with carbon cycle modelling. In this study, we aimed to estimate rice yield in Korea using such an integrative model using satellite remote sensing data in combination with a biophysical crop growth model. Specifically, daily meteorological inputs derived from MODIS (Moderate Resolution imaging Spectroradiometer) and radar satellite products were used to run a light use efficiency based crop growth model, which is based on the MODIS gross primary production (GPP) algorithm. The modelled biomass was converted to rice yield using a harvest index model. We estimated rice yield from 2003 to 2014 at the county level and evaluated the modelled yield using the official rice yield and rice straw biomass statistics of Statistics Korea (KOSTAT). The estimated rice biomass, yield, and harvest index and their spatial distributions were investigated. Annual mean rice yield at the national level showed a good agreement with the yield statistics with the yield statistics, a mean error (ME) of +0.56% and a mean absolute error (MAE) of 5.73%. The estimated county level yield resulted in small ME (+0.10~+2.00%) and MAE (2.10~11.62%),respectively. Compared to the county-level yield statistics, the rice yield was over estimated in the counties in Gangwon province and under estimated in the urban and coastal counties in the south of Chungcheong province. Compared to the rice straw statistics, the estimated rice biomass showed similar error patterns with the yield estimates. The subpixel heterogeneity of the 1 km MODIS FPAR(Fraction of absorbed Photosynthetically Active Radiation) may have attributed to these errors. In addition, the growth and harvest index models can be further developed to take account of annually varying growth conditions and growth timings.

Effectiveness of the Respiratory Gating System for Stereotectic Radiosurgery of Lung Cancer (폐암 환자의 정위적 방사선 수술 시 Respiratory Gating System의 유용성에 대한 연구)

  • Song Heung-Kwon;Kwon Kyung-Tae;Park Cheol-Su;Yang Oh-Nam;Kim Min-Su;Kim Jeong-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.125-131
    • /
    • 2005
  • Purpose : For stereotactic radiosurgery (SRS) of a tumor in the region whose movement due to respiration is significant, like Lung lower lobe, the gated therapy, which delivers radiation dose to the selected respiratory phases when tumor motion is small, was performed using the Respiratory gating system and its clinical effectiveness was evaluated. Materials and Methods : For two SRS patients with a tumor in Lung lower lobe, a marker block (infrared reflector) was attached on the abdomen. While patient' respiratory cycle was monitored with Real-time Position Management (RPM, Varian, USA), 4D CT was performed (10 phases per a cycle). Phases in which tumor motion did not change rapidly were decided as treatment phases. The treatment volume was contoured on the CT images for selected treatment phases using maximum intensity projection (MIP) method. In order to verify setup reproducibility and positional variation, 4D CT was repeated. Results : Gross tumor volume (GTV) showed maximum movement in superior-inferior direction. For patient #1, motion of GTV was reduced to 2.6 mm in treatment phases ($30{\sim}60%$), while that was 9.4 mm in full phases ($0{\sim}90%$) and for patient #2, it was reduced to 2.3 mm in treatment phases ($30{\sim}70%$), while it was 11.7 mm in full phases ($0{\sim}90%$). When comparing two sets of CT images, setup errors in all the directions were within 3 mm. Conclusion : Since tumor motion was reduced less than 5 mm, the Respiratory gating system for SRS of Lung lower lobe is useful.

  • PDF

Technical Efficiency in Korea: Interindustry Determinants and Dynamic Stability (기술적(技術的) 효율성(效率性)의 결정요인(決定要因)과 동태적(動態的) 변화(變化))

  • Yoo, Seong-min
    • KDI Journal of Economic Policy
    • /
    • v.12 no.4
    • /
    • pp.21-46
    • /
    • 1990
  • This paper, a sequel to Yoo and Lee (1990), attempts to investigate the interindustry determinants of technical efficiency in Korea's manufacturing industries, and also to conduct an exploratory analysis on the stability of technical efficiency over time. The hypotheses set forth in this paper are most found in the existing literature on technical efficiency. They are, however, revised and shed a new light upon, whenever possible, to accommodate any Korea-specific conditions. The set of regressors used in the cross-sectional analysis are chosen and the hypotheses are posed in such a way that our result can be made comparable to those of similar studies conducted for the U.S. and Japan by Caves and Barton (1990) and Uekusa and Torii (1987), respectively. It is interesting to observe a certain degree of similarity as well as differentiation between the cross-section evidence on Korea's manufacturing industries and that on the U.S. and Japanese industries. As for the similarities, we can find positive and significant effects on technical efficiency of relative size of production and the extent of specialization in production, and negative and significant effect of the variations in capital-labor ratio within industries. The curvature influence of concentration ratio on technical efficiency is also confirmed in the Korean case. There are differences, too. We cannot find any significant effects of capital vintage, R&D and foreign competition on technical efficiency, all of which were shown to be robust determinants of technical efficiency in the U.S. case. We note, however, that the variables measuring capital vintage effect, R&D and the degree of foreign competition in Korean markets are suspected to suffer from serious measurement errors incurred in data collection and/or conversion of industrial classification system into the KSIC (Korea Standard Industrial Classification) system. Thus, we are reluctant to accept the findings on the effects of these variables as definitive conclusions on Korea's industrial organization. Another finding that interests us is that the cross-industry evidence becomes consistently strong when we use the efficiency estimates based on gross output instead of value added, which provides us with an ex post empirical criterion to choose an output measure between the two in estimating the production frontier. We also conduct exploratory analyses on the stability of the estimates of technical efficiency in Korea's manufacturing industries. Though the method of testing stability employed in this paper is never a complete one, we cannot find strong evidence that our efficiency estimates are stable over time. The outcome is both surprising and disappointing. We can also show that the instability of technical efficiency over time is partly explained by the way we constructed our measures of technical efficiency. To the extent that our efficiency estimates depend on the shape of the empirical distribution of plants in the input-output space, any movements of the production frontier over time are not reflected in the estimates, and possibilities exist of associating a higher level of technical efficiency with a downward movement of the production frontier over time, and so on. Thus, we find that efficiency measures that take into account not only the distributional changes, but also the shifts of the production frontier over time, increase the extent of stability, and are more appropriate for use in a dynamic context. The remaining portion of the instability of technical efficiency over time is not explained satisfactorily in this paper, and future research should address this question.

  • PDF