• Title/Summary/Keyword: Grooved

Search Result 377, Processing Time 0.029 seconds

Experimental Study on the Working Characteristic of Aluminum Grooved Heat Pipe and Thermosyphon with Inner Arterial Wick (내부 아터리가 있는 알루미늄 그루브 히트파이프와 써모사이펀의 작동특성에 관한 실험적 연구)

  • 홍진관;김대성;정원복
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.894-900
    • /
    • 2000
  • The experimental study for performance improvement of aluminum/freon22 grooved heat pipe was carried out. Arterial wick was used for performance improvement of heat pipe. The experimental result was compared with screen covered grooved wick heat pipe. And also, performance test of grooved wick thermosyphon inserted straight wire in the center of grooved pipe was carried out. This result was compared with the performance test result of grooved wick thermosyphon. The operation limit of artery inserted grooved heat pipe was slightly extended, but thermal resistance of this heat pipe was twice as large as that of screen covered grooved heat pipe. In case of thermosyphon, the operation limit of grooved thermosyphon inserted straight wire in the center of grooved pipe was slightly extended, but thermal resistance was increased, comparing with that of the grooved thermosyphon.

  • PDF

Characteristics of the electrospraying combustion using grooved nozzle (홈노즐을 이용한 정전분무 확산 연소 특성에 관한 연구)

  • Kim, Woo-Jin;Kim, Kyoung-Tae;Kim, Sang-Soo
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2366-2371
    • /
    • 2007
  • Spray combustion characteristics of a conducting fuel electrospray have been studied for clean combustion technology. The multiplexing system which can retain the characteristics of the cone-jet mode is inevitable for the electrospray application. Charged micro droplets can be obtained in almost uniform size during operating the electrospray in the cone-jet mode. This experiment device set up the multiplexed grooved nozzle system with the extractor. Using the grooved nozzle, the stable cone-jet mode can be achieved at the each groove in the grooved mode. This electrospray system was applied to the diffusion combustion. It is the first step to discover the diffusion combustion characteristics of the electrospray. In case of the single grooved nozzle electrospray, the diffusion flames are occurred at each jet of grooved mode and they are quite stable. The exhaust gas analysis was indicated that there is the critical point which can make very stable diffusion combustion.

  • PDF

Characteristics of the Electrospraying Combustion Using Grooved Nozzle (홈노즐을 이용한 정전분무 확산 연소 시스템 개발 및 특성 연구)

  • Kim, Woo-Jin;Kim, Kyoung-Tae;Kim, Sang-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.12
    • /
    • pp.979-985
    • /
    • 2007
  • Spray combustion characteristics of the conducting fuel electrospray has been studied for clean combustion technology. The electrospraying multiplexed system which can maintain the characteristics of the cone-jet mode is able to obtain charged micro droplets with high flow rate. In addition, they have monodisperse distribution during operating the electrospray in the cone-jet mode. The multiplexed grooved nozzle system with the extractor was applied to this experimental device set up. The stable grooved mode can be generated by the grooved nozzle and this electrospray system was applied to the diffusion combustion. It is the first step to discover the diffusion combustion characteristics of the electrospray, In case of the single grooved nozzle electrospray the diffusion flames are occurred at each Jet of grooved mode and they are quite stable. The exhaust gas analysis was indicated that there is the critical point which can make very stable diffusion combustion

A Study on the Heat Transfer Performance Using Various Grooved Heat Transfer Tubes (다양한 전열관 내부 홈 변화에 의한 열전달 성능에 관한 연구)

  • Han, K.I.;Chung, W.K.;Ye, S.S.;Park, S.H.
    • Journal of Power System Engineering
    • /
    • v.4 no.1
    • /
    • pp.26-32
    • /
    • 2000
  • Single-phase heat transfer performance and pressure drop for internally grooved tubes with angles were studied. Experiments were carried out in a counter flow heat exchanger with water as a working fluid. Two commercially available internally grooved tubes and smooth tube were tested. The internal diameter of the smooth tube was 16.5mm and the internal diameters of grooved tubes were 15.4mm, 14.9mm, 15.0mm, 16.7mm, respectively. Grooved angles in the tubes were $37^{\circ},\;43^{\circ},\;45^{\circ},\;50^{\circ}$, respectively. An experimental device to measure the friction factor and heat transfer coefficient was constructed. The experimental results were obtained for the fully developed turbulent flow of water in tube on the condition of uniform heat flux. As the increase of flow rate, Reynolds number, numbers of groove and grooved angle led to the increase of pressure drop. Also this paper showed that heat transfer rate increased with increasing numbers of groove and grooved angle. An empirical relation taken from this study represented most of the data within ${\pm}25%$.

  • PDF

Normative values for the Grooved Pegboard Test in Adult (Grooved pegboard 검사의 정상성인의 표준치에 관한 연구)

  • Lee, Teak-Young
    • Physical Therapy Korea
    • /
    • v.8 no.2
    • /
    • pp.87-94
    • /
    • 2001
  • Dexterity is defined in the present study as interdigital manipulative skill or the fine manipulative movements of objects held between the thumb and fingers. The Grooved pegboard test has been used to evaluate dexterity requring visual-motor coordination. The purpose of this study was to standardize the completion time of the Grooved pegboard test in different age groups and gender. Normative values for the Grooved Pegboard Test was developed on the sample of 282 healthy volunteers (89 men and 183 women). Subjects were stratified according to gender and dominant hand and were subdivided into six groups by blocking. The results of this study were as follows: 1) There was a significant difference in completion time between dominant and nondominant hand in both men and women groups (p<.05). 2) There were significant differences in completion time between men and women group (p<.05) 3) There were significant differences in completion time among age groups (p<.05).

  • PDF

Analysis of Herringbone Grooved Journal Bearing Using Generalized Coordinate Transformation (일반좌표계 변환을 이용한 헤링본 그루브 베어링의 해석)

  • 박상신;한동철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.317-324
    • /
    • 1999
  • The present work is an attempt to calculate the steady state pressure and perturbed pressure of herringbone grooved journal bearings. A generalized coordinate system is introduced to handle the complex bearing geometry. The coordinates are fitted to the groove boundary and the Reynold's equation is transformed to be fitted to this coordinates system using the Gauss divergence theorem. This method makes it possible to deal with an arbitrary configuration of a lubricated surface. The characteristics of finite herringbone grooved journal are well calculated using this method.

  • PDF

Bow-tie Mode Lasing in a Grooved Rectangular Semiconductor Microcavity

  • Moon, Hee-Jong;Hyun, Kyung-Sook
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.162-165
    • /
    • 2012
  • Bow-tie modes were proposed in a grooved rectangular resonator and their lasing characteristics were investigated in semiconductor microcavities. The observed spacing between two adjacent lasing peaks from the grooved cavity was reduced compared to that of 4-bounce whispering gallery modes (WGMs) from the same-sized simple rectangular cavity due to increased round-trip path length of the bow-tie modes. The lasing spectra of bow-tie modes obtained from two adjacent corners showed highly correlated patterns while those of 4-bounce WGMs did not.

Testing for the Effect of Groove Depths on the Rotordynamic Coefficients and Leakage of Circumferentially-Grooved Seals (Circumferentially-Grooved Seal의 동특성 계수 및 누설량에 미치는 Groove 깊이의 영향에 관한 실험)

  • ;Childs, D.W.
    • Tribology and Lubricants
    • /
    • v.4 no.2
    • /
    • pp.68-75
    • /
    • 1988
  • 서로 다른 그루브 깊이를 갖는 circumferentially-grooved 씨일들의 동특성 계수 및 누설량에 대한 실험결과를 분석하였다. 실험된 결과를 분석해 보면, 그루브 깊이가 증가함에 따라, 누설량이 서서히 증가함을 알수 있다. Smooth 씨일 및 damper 씨일과 비교할때, smooth 씨일은 최대의 direct stiffness를 가지며, 평균 씨일 간극의 증가함에 따라 direct stiffness가 감소한다. Effective damping에 있어서, circumferentially-grooved 씨일은 최소의 값을 가지는 반면, 누설량은 가장 적다. 이론과의 실험치 비교는 일반적으로 만족할만한 결과를 보인다.

Quasi-static Analysis on the Effect of the Finite Metal with the Anisotropic Grooved Dielectric in Microstrip Lines

  • Hong Ic-Pyo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.1 s.34
    • /
    • pp.17-20
    • /
    • 2005
  • In this paper, we presented the quasi-static characteristics of novel microstrip lines with anisotropic grooved dielectric in finite metal. A quasi-static mode-matching method has been used to analyze this new structure and the simulation results are validated through comparison with other available results. The results in this paper show that it is possible to control the propagation characteristics of microstrip lines with the use of anisotropic grooved dielectric in finite metal. Also anisotropic grooved dielectric in microstrip line can be newly added to the design parameters of high performance three dimensional monolithic microwave circuits and other microwave applications.

  • PDF

The Performance of AC PDP with Grooved Dielectric Structure in High Xe Contents

  • Kim, Tae-Jun;Bae, Hyun-Sook;Jeong, Dong-Cheol;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.88-90
    • /
    • 2003
  • We reported an AC PDP structure with grooved front panel dielectric layer. The structure exhibits low breakdown voltage, better luminance, and better endurance to crosstalk in high Xe contents. It also shows less luminous efficacy then conventional structure because of the thinner dielectric layer, but we can apply the higher Xe contents to the grooved dielectric structure, which results in the higher luminous efficacy. We made experiments with the Xe contents from 4 to16% and total gas pressure from 400 to 600Torr. The grooved dielectric structure shows the improvement of 20% luminous efficacy and 17% luminance. The firing voltages lower about 40V at 600Torr and Xe 12, 16%. The discharge characteristics of grooved dielectric structure are verified also with 2D simulation.

  • PDF