Modulated Finite Control Set - Model Predictive Control for Harmonic Reduction in a Grid-connected Inverter

  • Nguyen, Tien Hai;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.268-269
    • /
    • 2017
  • This paper presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. Distorted grid condition is undesirable due to negative effects such as power losses and heating problem in electrical equipments. To enhance the power quality of distributed generation systems under such a condition, a modulated finite control set - model predictive control (MFCS-MPC) scheme will be proposed, in which the optimal switching signals of inverter are chosen by online basis using the principle of current error minimization. In addition, the moving average filter (MAF) is used to improve the phase-lock loop in order to obtain the harmonic-free reference currents on the stationary frame. The usefulness of the proposed MFCS-MPC method is proved by the comparative simulation results under different operating conditions.

  • PDF

The Analysis and Study on Operation Strategy of Grid-connected Series Small Wind Turbine System (계통연계형 직렬운전 소형풍력발전시스템의 해석 및 운전방안 연구)

  • Kim, Chang-Ha;Ku, Hyun-Keun;Son, Yung-Deug;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.1
    • /
    • pp.59-64
    • /
    • 2015
  • This paper proposes an analysis and operation strategy of a grid-connected wind turbine system using a diode rectifier. The currents of generators are the same as that of a small wind turbine system. Therefore, the analysis of generator torque is required as opposed to an analysis of blade speed. In this paper, the appropriate MPPT control method is proposed to control generator torque. Usefulness of the proposed operation strategy is verified by simulations and experiments.

Design and Implementation of a Low Cost Grid-Connected 5 kVA Photovoltaic System with Load Compensation Capability

  • Mejdar, Reza Seifi;Salimi, Mahdi;Zakipour, Adel
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2306-2314
    • /
    • 2016
  • Design and implementation of a low cost grid-connected 5kVA solar photovoltaic (PV) system is proposed in this paper. Since the inverter is a major component of the PV system, the B4 inverter used in this paper reduces the total cost of the PV system. In order to eliminate the massive transformer, the PV system is connected to the grid through IGBT switches. In addition to injection of active power into the grid, the B4 inverter can compensate reactive power and reduce harmonics of the nonlinear loads. A TMS320F28335 DSP processor is used for effective control of the B4 inverter. Various features of this processor enable the implementation of the necessary control algorithms. As a first step, the PV system is simulated and evaluated in Matlab/Simulink. In the second step, hardware circuits are designed and implemented based on the simulation results. The operation of the PV system has been evaluated under balanced, unbalanced, linear and nonlinear loads which proves its accuracy and efficiency.

Control of an Open Winding Machine in a Grid-Connected Distributed Generation System (오픈 와인딩 머신을 이용한 계통 연계형 분산 발전 시스템의 제어)

  • Kwak, Mu-Shin;Sui, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.83-86
    • /
    • 2006
  • A grid-connected distributed generation system which consists of engine generator, dc link with multiple energy sources and inverter is proposed. All six of the stator leads of the generator, which is a surface mount permanent magnet machine, are brought out to the terminal of the generator. Three leads are connected to the inverter and the others are connected to the utility grid. In this proposed system the power from the engine-generator and the power from dc link can be controlled simultaneously by only one three-phase power converter. A control algorithm for the system is developed and verified by experiment results.

  • PDF

Performance Analysis of Anti-islanding Function for Grid-connected PV Inverter Systems under Parallel Connections (병렬운전하는 계통연계형 태양광 발전용 인버터의 단독운전 검출 성능 분석)

  • Jung, Young-Seok;Yu, Byung-Gyu;Kang, Gi-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.34-40
    • /
    • 2013
  • Islanding phenomenon of photovoltaic system is undesirable because it leads to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized re-closure. Anti-islanding protection is an important technical requirement for grid-connected PV system. Until now, various anti-islanding methods for detecting and preventing islanding of photovoltaic and other distributed generations have been proposed. Most of them are focusing on the anti-islanding performance of single PV system according to the related international and domestic standard test procedures. There are few studies on the islanding phenomenon for multiple photovoltaic operation in parallel. This paper presents performance analysis of anti-islanding function for grid-connected PV inverter systems when several PV inverters are connected in parallel.

Grid-Connected Photovoltaic System Applying the Step Variable MPPT Control and DVR (Step 가변형 MPPT 제어기법과 DVR을 적용한 계통연계형 태양광 발전 시스템)

  • Lee, Yong-Sik;Jeong, Sung-Won;Gim, Jae-Hyeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.42-49
    • /
    • 2012
  • Grid-connected photovoltaic generator system requires high performance PCS(Power Conditioning System) according to the standard of 'Distributed Generation Grid-Connected Technology Standards'. This paper presents the MPPT control method which improves output efficiency through fast tracking to the maximum power point of PV and a reduced self-excited vibration. Secondly, in this paper DVR function was applied to PCS to compensate the voltage sag frequently happening for a power system. The proposed PCS control is analyzed and compared to conventional PCS operating characteristic, the various insolation and loads, and voltage sag condition through PSIM tool. It proves the utility.

Modified RCC MPPT Method for Single-stage Single-phase Grid-connected PV Inverters

  • Boonmee, Chaiyant;Kumsuwan, Yuttana
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1338-1348
    • /
    • 2017
  • In this study, a modified ripple correlation control (RCC) maximum-power point-tracking (MPPT) algorithm is proposed for a single-stage single-phase voltage source inverter (VSI) on a grid-connected photovoltaic system (GCPVS). Unlike classic RCC methods, the proposed algorithm does not require high-pass and low-pass filters or the increment of the AC component filter function in the voltage control loop. A simple arithmetic mean function is used to calculate the average value of the photovoltaic (PV) voltage, PV power, and PV voltage ripples for the MPPT of the RCC method. Furthermore, a high-accuracy and high-precision MPPT is achieved. The performance of the proposed algorithm for the single-stage single-phase VSI GCPVS is investigated through simulation and experimental results.

Modal Analysis of Resonance and Stable Domain Calculation of Active Damping in Multi-inverter Grid-connected Systems

  • Wu, Jian;Chen, Tao;Han, Wanqin;Zhao, Jiaqi;Li, Binbin;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.185-194
    • /
    • 2018
  • Interaction among multiple grid-connected inverters has a negative impact on the stable operations and power quality of a power grid. The interrelated influences of inverter inductor-capacitor-inductor filters constitute a high-order power network, and consequently, excite complex resonances at various frequencies. This study first establishes a micro-grid admittance matrix, in which inverters use deadbeat control. Multiple resonances can then be evaluated via modal analysis. For the active damping method applied to deadbeat control, the sampling frequency and the stable domain of the virtual damping ratio are also presented by analyzing system stability in the discrete domain. Simulation and experimental results confirm the efficiency of modal analysis and stable domain calculation in multi-inverter grid-connected systems.

A Novel Harmonic Compensation Method for the Single Phase Grid Connected Inverters (단상 계통연계 인버터를 위한 새로운 고조파 보상법)

  • Khan, Reyyan Ahmad;Ashraf, Muhammad Noman;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.144-146
    • /
    • 2018
  • In order to meet the harmonics standards such as IEEE 519 and P1547 the output quality of a grid connected inverter should satisfy a certain level of Total Harmonic Distortion (THD) value. However, the output quality of an inverter gets degraded due to the grid voltage harmonics, the dead time effects and the nonlinearity of the switches, which all contributes to a higher THD value of the output. In order to meet the required THD value for the inverter output under the distorted grid condition the use of harmonic controller is essential. In this paper a novel feedforward harmonic compensation method is proposed in order to effectively eliminate the low order harmonics in the inverter current to the grid. In the proposed method, unlike the conventional harmonic control methods, the hamonic components are directly compensated by the feedforward terms generated by the PR controller with the grid current in the stationary frame. The proposed method is simple in implementation but powerful in eliminating the harmonics from the output. The effectiveness of proposed method is verified through the PSIM simulation and the experiments with a 5kW single phase grid connected inverter.

  • PDF

Design of Triple Loop Current Control for Auxiliary Power Unit of Fuel Cell Train having Grid Connected Inverter Function (계통 연계 기능을 갖는 연료전지 철도차량 보조전원장치의 삼중 루프 전류 제어기 설계)

  • Kwon, Il-Seob;Baek, Seung-Woo;Kim, Hag-Wone;Cho, Kwan-Yual
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.4
    • /
    • pp.293-302
    • /
    • 2020
  • This study proposes a triple-loop current control method for the auxiliary power unit of fuel cell trains. The auxiliary power unit of fuel cell trains has a grid-connected function when power is supplied to the utility grid. Moreover, the auxiliary power unit of trains has a 1500 V DC link voltage; thus, PWM frequency cannot be increased to a high frequency. Owing to this low PWM frequency condition, creating a triple-loop design is difficult. In this study, a triple-loop controller is developed for a capacitor voltage controller in standalone mode that operates as an auxiliary power supply for trains and for a grid current controller in grid control mode with an inner capacitor voltage controller. The voltage controller employs an inductor current controller inner loop. To overcome low PWM frequency, a design method for the bandwidth of the capacitor voltage controller considering the bandwidth of the inner inductor current controller is described. The effectiveness of the proposed method is proven using PSIM simulation.