• Title/Summary/Keyword: Grid-connected PCS

Search Result 115, Processing Time 0.021 seconds

Analysis on Insulation and Protection Characteristics of Grid Connected ESS in Ground/Short-Circuit Fault (지/단락실증시험에서 MW급 계통연계형 ESS 절연/보호시스템 성능 분석에 관한 연구)

  • Kim, Jin-Tae;Lee, Seung-Yong;Park, Sang-Jin;Cha, Han-Ju;Kim, Soo-Yeol
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.119-122
    • /
    • 2020
  • With recent ESS (Energy Storage System) fire accident, the fault protection performance is becoming more important. However, there has never been any experiments with the protection performance on the faults in the ESS system level. In this study, the effect of AC ground fault and IGBT (Insulated Gate Bipolar mode Transistor) short-circuit failure on MW class ESS was performed experimentally for the first time in the world. First of all, the effect of the AC single line ground fault on battery was analyzed. Moreover, the transient voltage was investigated as a function of the battery capacity and the power level. Finally, the breaking capability and insulation performance of ESS were examined under PCS short-circuit fault condition. Through the tests, it was found that ESS protection system safely blocked the faulty current regardless of the faults, whereas the electronic parts such as IGBT and MC (Magnetic Contactor) were broken by the fault current. Also, the electrical breakdown in ESS resulted from the transient voltage during the protection process.

Modeling and Development of control algorithm for Grid-Connected MW ESS (계통연계형 MW급 ESS의 모델링 및 제어알고리즘 개발)

  • Jung, Se-Hyung;Kim, Joo-Ha;Jung, Ah-Jin;Yang, Seok-Hyun;Park, Sung-Youl;Choi, Se-Wan;Kang, Byung-Kwan;Lee, Chung-Woo;Yoo, An-No;Kim, Hee-Jung
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.65-66
    • /
    • 2014
  • 본 논문에서는 부하평준화를 통한 전기요금 절감효과, 무효전력 보상을 통한 역률 개선 및 비상부하 전원공급을 위한 독립운전 기능을 갖는 MW급 ESS에서 PCS뿐 아니라 배터리, 변압기, 각종부하 및 디젤발전기 등 계통 내 구성 요소들을 실제 사양 및 데이터를 기반으로 모델링하였다. 또한 1MW PCS를 위한 유 무효전력, CC-CV 충전 및 독립운전 제어알고리즘을 개발하였으며 시뮬레이션 및 축소시험을 통해 본 논문의 타당성을 검증하였다.

  • PDF

Reactive Power Variation Method for Anti-islanding Using Digital Phase-Locked-Loop (DPLL을 이용한 능동적 단독운전방지를 위한 무효전력변동법)

  • Lee, Ki-Ok;Yu, Byung-Gu;Yu, Gwon-Jong;Choi, Ju-Yeop;Choy, Ick
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.2
    • /
    • pp.64-69
    • /
    • 2008
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, these have raised potential problems of network protection on electrical power system. One of the numerous problems is an Islanding phenomenon. There has been an argument that it may be a non-issue in practice because the probability of islanding is extremely low. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an islanding can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficiently to cause a trip, plus the time required to execute a trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. Third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an islanding. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. Therefore the verification of anti-islanding performance is strongly needed. In this paper, improved RPV method is proposed through considering power quality and anti-islanding capacity of grid-connected single-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation results are verified.

A Study on the External Fault Performance Evaluation of Grid-Connected Power Conditioning System for Residential Fuel Cell System (가정용 연료전지시스템 계통연계형 전력변환장치의 외부사고 성능평가에 관한 연구)

  • Lee, Jung-Woon;Seo, Won-Seok;Kim, Young-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.131-131
    • /
    • 2009
  • 최근 환경규제가 강화되면서 친환경적인 전력생산 요구 등의 외부환경 변화에 따른 우리나라의 전력구조가 기존의 중압 집중형 발전을 탈피한 분산전원 발전에 대한 관심이 증대되고 있는 실정이다. 특히, 분산전원으로서의 전력생산은 공급의 안전성, 경쟁력 및 에너지의 지속성 등이 요구되어지는데, 재생에너지가 가지고 있는 에너지 지속성의 한계 및 설치의 제약성을 탈피할 수 있는 시스템으로 현재 연료전지시스템이 가장 근접해 있는 실정이다. 즉, 도시가스 인프라가 우수하고 인구조밀 지역이 많은 우리나라의 특성상 각 가정 및 건물에 쉽게 설치하고 공급의 안전성을 갖는 건물용 연료전지는 최근 가장 각광받고 있는 분산전원 시스템 중의 하나이다. 올해부터 모니터링사업의 일환으로 수용가에 설치 될 연료전지 시스템이 얼마나 안정적으로 전기와 열을 각 가정에 공급하고 시스템의 안전성을 확보하는 가는 건물용 연료전지의 분산전원으로서의 가능성 및 국민의 수용성을 증대시키는 중요한 역할을 할 것이다. 연료전지시스템은 상용전력과 연계되어 있기 때문에 시스템의 안정성 뿐만 아니라 상용전력의 변화에 대응하여 안정적인 운전을 하는지에 대한 평가가 필수적이다. 이에 따라 본 연구에서는 가정용 연료전지시스템의 성능 및 안전성평가의 일환으로 계통연계형 전력변환장치의 성능 및 안전성을 평가 하고자 한다. 연료전지 검사를 위한 계통연계형 전력변환장치의 시험평가 항목으로는 크게 정상특성성능시험, 보호기능성능시험, 과도응답특성성능시험 및 외부사고성능시험 등으로 나뉘어진다. 본 연구에서는 외부사고 성능시험 항목들인 출력측 단락시험, 계통전압 순간정전?순간강하시험 및 부하차단 시험 등을 통하여 외부사고에 대한 성능 및 안전성을 평가하였다. 외부사고 성능시험의 주 목적은 시스템의 이상 운전이 아니라 외부의 영향에 따른 시스템의 안전성 및 전력품질을 평가한다. 출력측 단락시험을 수행하기 위해서 전력변환장치를 정격 출력 전압, 정격 출력 주파수 및 정격 출력에서 운전한 후, 교류 전원장치는 단락 전류를 검출하여, 사고 발생 후 0.3초 이내에 개방하도록 설정하였다. 여기서, 단락 저항 Rsc를 정격 전류의 10배 이상에 해당하는 부하와 같은 값으로 설정하였다. 스위치 SWSC를 폐로하여 단락 상태를 만들며, 이 때 전력변환장치의 출력전류와 차단 또는 정지 시간을 측정하였다. 실험 결과에 대한 판정기준은 단락전류를 검출하여 0.5초 이내에 개폐기 개방 또는 게이트 블록 기능이 동작하여 시스템을 안정하게 정지시키고 시스템 어떤 부위에도 손상이 없어야 한다. 실험 결과 파워컨디셔너의 출력전류 및 차단 또는 정지된시간이 40ms로 나타났고, 출력전류의 파형도 매우 안정함을 볼 수 있었다. 이와 같이 모든 실험을 수행한 결과 외부사고에 대하여 시스템이 안전하게 정지하는 등 연료전지 시스템의 안전성을 확인하였다.

  • PDF

Vector Control for Wave Power Generation System using Permanent Magnet Linear Synchronous Generator (파력발전용 선형발전시스템의 벡터제어)

  • Park, Joon Sung;Hyon, Byong Jo;Yun, Junbo;Lee, Ju;Choi, Jang-Young;Choi, Jong-Su;Hong, Keyyong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.2
    • /
    • pp.120-128
    • /
    • 2016
  • This paper describes power generation from sea waves by using linear permanent magnet generator. A buoy is placed on the ocean surface and connected to the generator. The wave energy is carried out from the movement of a buoy. An electrical conversion system is needed between the generator and the grid. For an analysis of the power system, the modeling of the linear generator and converter system was proceeded. This paper proposes vector control method for wave power generation system using linear generator. In order to verify the proposed method, simulation and experiment performed and the results support the validity of the control scheme.