• Title/Summary/Keyword: Grid test

Search Result 953, Processing Time 0.026 seconds

Comparison of Radiating Ocean Boundary Conditions by Error Analysis (오차해석에 의한 해양방사경계조건 비교)

  • 서승원;윤태훈
    • Water for future
    • /
    • v.22 no.3
    • /
    • pp.315-322
    • /
    • 1989
  • The effects of open boundary conditions including the radiation condition are compared by utilizing the $L^{2_}$-norm and RMS error in the numerical modeling of ocean problem. In numerical tests of $M_2$ tide, grid size and bed roughness are considered and analyzed. For the $M_2$ tide test in a simplified bay where the analytical solutions are available, it is found that improved radiating boundary condition(IMPSOM) may increase the reliability of computed results by 40% of $L^{2_}$-norm and 96% of RMS error than the open boundary condition without radiation effect. In case of using the half-size grids, better results are obtained. It is also found that the IMPSOM is applicable with satisfaction when the bottom friction is included.

  • PDF

Frequency Control Method of Grid Interconnected Microgrid Operating in Stand Alone Mode (계통연계형 마이크로그리드의 독립운전시 주파수 제어에 관한 연구)

  • Chae, Woo-Kyu;Lee, Hak-Ju;Park, Jung-Sung;Cho, Jin-Tae;Won, Dong-June
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1099-1106
    • /
    • 2012
  • Microgrid is a new electrical energy system that composed of various generators, renewable energy, batteries and loads located near the electrical customers. When Microgrid is interconnected with large power system, Microgrid don't need to control the frequency. But in case of the outage or faults of power system, Microgrid should control the frequency to prevent the shutdown of Microgrid. This paper presents the frequency control methods using the droop function, being used by synchronous generators and EMS(Energy Management System). Using droop function, two battery systems could share the load based on locally measured signals without any communications between batteries. Also, we suggest that EMS should control the controllable distributed generators as P/Q control modes except batteries to overcome the weakness of droop function. Finally we suggest the two batteries systems to prolong the battery's life time considering the economical view. The validation of proposed methods is tested using PSCAD/EMTDC simulations and field test sites at the same time.

An Improved Photovoltaic System Output Prediction Model under Limited Weather Information

  • Park, Sung-Won;Son, Sung-Yong;Kim, Changseob;LEE, Kwang Y.;Hwang, Hye-Mi
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1874-1885
    • /
    • 2018
  • The customer side operation is getting more complex in a smart grid environment because of the adoption of renewable resources. In performing energy management planning or scheduling, it is essential to forecast non-controllable resources accurately and robustly. The PV system is one of the common renewable energy resources in customer side. Its output depends on weather and physical characteristics of the PV system. Thus, weather information is essential to predict the amount of PV system output. However, weather forecast usually does not include enough solar irradiation information. In this study, a PV system power output prediction model (PPM) under limited weather information is proposed. In the proposed model, meteorological radiation model (MRM) is used to improve cloud cover radiation model (CRM) to consider the seasonal effect of the target region. The results of the proposed model are compared to the result of the conventional CRM prediction method on the PV generation obtained from a field test site. With the PPM, root mean square error (RMSE), and mean absolute error (MAE) are improved by 23.43% and 33.76%, respectively, compared to CRM for all days; while in clear days, they are improved by 53.36% and 62.90%, respectively.

Control Strategy and Characteristic Analysis of Hybrid Active Power Filters with the Resonant Impedance Principle

  • Fang, Lu;Xu, Xian-Yong;Luo, An;Li, Yan;Tu, Chun-Ming;Fang, Hou-Hui
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.935-946
    • /
    • 2012
  • A new kind of resonant impedance type hybrid active filter (RITHAF) is proposed for dynamic harmonic current suppression and high capacity reactive compensation in medium and high voltage systems. This paper analyzed the different performance of the RITHAF when the active part of the RITHAF is controlled as a current source and as a voltage source, respectively. The harmonic suppression function is defined in this paper. The influences of the changes caused by the grid impedance and the detuning of the passive power filter on the compensating characteristics of the RITHAF are studied by analyzing the suppression function. Simulation and industrial application results show that the RITHAF has excellent performances in harmonic suppression and reactive compensation, which is suitable for medium and high voltage systems.

Design and Experiment of Three-phase Interleaved DC-DC Converter for 5kW Lead-Acid Battery Charger (5kW 배터리 충전기용 양방향 3상 인터리브드 DC-DC 컨버터 설계 및 실험)

  • Lee, Wu-Jong;Eom, Ju-Kyoung;Han, Byung-Moon;Cha, Han-Ju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.227-233
    • /
    • 2011
  • This paper proposes a design and experiment of three phase interleaved dc-dc converter for 5kW battery charger. The charger consists of a three-phase interleaved dc-dc converter, which interfaces batteries and DC link, and a grid connected inverter. Lead-acid battery is modeled in a simple R-C model by matlab. Parameters of the battery are estimated based on step current discharging test. The battery is connected to three-phase interleaved DC-DC converter in order to reduce the ripple current to the battery and so, increase the lifetime of battery. Controller for charging and discharging mode is designed and tested in a 5kW charger prototype.

Multiobjective Optimal Reactive Power Flow Using Elitist Nondominated Sorting Genetic Algorithm: Comparison and Improvement

  • Li, Zhihuan;Li, Yinhong;Duan, Xianzhong
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.70-78
    • /
    • 2010
  • Elitist nondominated sorting genetic algorithm (NSGA-II) is adopted and improved for multiobjective optimal reactive power flow (ORPF) problem. Multiobjective ORPF, formulated as a multiobjective mixed integer nonlinear optimization problem, minimizes real power loss and improves voltage profile of power grid by determining reactive power control variables. NSGA-II-based ORPF is tested on standard IEEE 30-bus test system and compared with four other state-of-the-art multiobjective evolutionary algorithms (MOEAs). Pareto front and outer solutions achieved by the five MOEAs are analyzed and compared. NSGA-II obtains the best control strategy for ORPF, but it suffers from the lower convergence speed at the early stage of the optimization. Several problem-specific local search strategies (LSSs) are incorporated into NSGA-II to promote algorithm's exploiting capability and then to speed up its convergence. This enhanced version of NSGA-II (ENSGA) is examined on IEEE 30 system. Experimental results show that the use of LSSs clearly improved the performance of NSGA-II. ENSGA shows the best search efficiency and is proved to be one of the efficient potential candidates in solving reactive power optimization in the real-time operation systems.

Development of the Three Dimensional Landform Display Software Using the Digital Terrain Model (수치지형정보를 애용한 지형의 3차원 표현 software 개발)

  • 이규석
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.17 no.3
    • /
    • pp.1-8
    • /
    • 1990
  • The digital terrain model (DTM) or digital elevation model (DEM) is commonly used in representing the continuous variation of relief over space. One of the most frequent applications is to display the three dimensional view of the landform concerned. In this paper, the altitude matrices-regular grid cell format of the elevation in Mt. Kyeryong National Park were used in developing the three dimensional view software for the first time in Korea. It required the removal of hidden lines or surfaces. To do this, it was necessary to identify those surfaces and line segments that are visible and those that are invisible. Then, only the visible portions of the landform were displayed. The assumption that line segments are used to approximate contour surfaces by polygons was used in developing the three dimensional orthographic view. In order to remove hidden lines, the visibility test and masking algorithms were used. The software was developed in the engineering workstation, SUN 3/280 at the Institute of Space Science and Astronomy using 'C' in UNIX operating system. The software developed in this paper can be used in various fields. Some of them are as follows : (1) Landscape design and planning for identifying viewshed area(line of sight maps) (2) For planning the route selection and the facility location (3) Flight simulation for pilot training (4) Other landscape planning or civil engineering purposes

  • PDF

Fault Models and Diagonousis of Boundary Scan Board (경계스캔이 적용된 보드에서의 고장 모델 및 전단 기법)

  • Moon, Kweon-Woo;Song, Oh-Young
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.04b
    • /
    • pp.1619-1622
    • /
    • 2002
  • 최근에 생산되는 디지털 VLSI칩들은 그 집적도가 계속 높아지고 있으며, 이러한 칩들을 장착한 보드의 경우도 그 복잡성이 점차 높아지고 있다. 이에 따라 칩 및 보드에 대한 철저한 테스트 과정이 요구된다. 지금까지 보드 테스트 방법으로 널리 쓰였던 ICT(In-Circuit Test)는 칩의 고집적화에 따른 핀 간격의 조밀화와 SMT(Surface Mount Technology), BGA(Ball Grid Array), MCM(Multi Chip Module) 등의 새로운 패키징 방식의 등장에 따라 테스트 방법으로의 한계성을 드러내고 있다. 이에 대한 대안으로 등장한 IEEE Std 1149.1 은 ICT의 한계성을 극복할 수 있는 기술일 뿐 아니라 여러 가지 장점을 가지고 있으며 그 활용 분야도 다양하다. 본 논문에서는 IEEE Std 1149.1에 따라 설계된 보드 상에서 발생 가능한 고장들에 대한 고장 모델을 제시한다. 또한 각 고장 모델들의 양상과 진단 기법을 제시한다. 이를 통해 IEEE Std 1149.1에 따라 설계된 보드 상에서 발생한 고장들을 검출할 수 있으며, 고장의 종류 및 성격, 그리고 고장의 발생 위치 등의 정보를 얻을 수 있다. IEEE Std 1149.1에 따른 보드 설계가 보드의 신뢰성 보장에 긴요함을 인식하는 계기가 되기를 기대하며 제시된 고장 모델 및 진단 기법이 기술적으로 중요한 참고자료가 되기를 기대한다.

  • PDF

NeW Output Voltage Control Scheme Based on SoC Variation of BESS Applicable for Stand-alone DC Microgrid (독립형 DC 마이크로그리드에 적용 가능한 BESS의 SoC를 기반으로 한 새로운 출력전압 제어기법)

  • Yu, Seung-Yeong;Kim, Hyun-Jun;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1176-1185
    • /
    • 2016
  • This paper proposes a new output voltage control scheme based on the SoC variation of the battery energy storage system (BESS) applicable for the stand-alone DC microgrid. The proposed control scheme provides relatively lower variation of the DC grid voltage than the conventional droop method. The performance of proposed control scheme was verified through computer simulations for a typical stand-alone DC microgrid which consists of BESS, photo-voltaic (PV) panel, engine generator (EG), and DC load. A scaled hardware prototype for the stand-alone DC microgrid with DSP controller was set up in the lab, and the proposed control algorithm was installed in the DSP controller. The test results were compared with the simulation results for performance verification and actual system implementation.

Simulation of Anti-Islanding Algorithms regarding IEEE Std. 1547.1 for Grid-Connected Photovoltaic Inverters (계통연계형 태양광 인버터의 IEEE Std. 1547.1 에 따른 단독운전 검출 알고리즘의 시뮬레이션)

  • Ko, Moon-Ju;Choy, Ick;Choi, Ju-Yeop;Lee, Ki-Ok;Yu, Gwon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.323-325
    • /
    • 2005
  • 본 논문에서는 계통연계형 태양광 발전 시스템에서의 단독운전 검출 시뮬레이션 과정을 설명한다. 전기적 시스템의 단독운전은 계통이 끊어진 상태에서 분산 전원이 계속 동작하여 지역 부하로 전력이 공급될 때 나타나는 현상이다. 이러한 현상은 계통 보수 작업자의 안전을 위협하며, 다른 전기적 장비에 악영향을 미칠 수 있다. 단독운전 검출 기능은 계통과 연계된 분산전원과 같은 기능을 가진 태양광 발전 시스템에 사용되는 인버터에서는 주요한 요구사항이다. IEEE Std. 1547.1 "IEEE Standard Conformance Test Procedures for Equipment Interconnecting Distribuyed Resources with Electric Power Systems" 는 단독운전 검출을 필요로 하는 시스템의 테스트 요구사항을 정하고 있다. 본 논문은 단독운전 검출 알고리즘과 IEEE Std. 1547.1의 내용에 준한 인버터 시뮬레이션 테스트의 예를 보여준다. PSIM을 이용한 시뮬레이션 과정과 결과 파형의 분석을 토대로 계통연계형 인버터의 시뮬레이션 절차와 방법에 대해 알아본다.

  • PDF