• Title/Summary/Keyword: Grid structure

Search Result 866, Processing Time 0.026 seconds

Welding Quality Evaluation on the LASER Welding Parts of the Spacer Grid Assembly for PWR Fuel Assembly (경수로 원전연료용 지지격자체의 LASER 용접부위 평가)

  • Song Gi Nam;Yun Gyeong Ho;Gang Heung Seok;Lee Gang Hui;Kim Su Seong
    • Proceedings of the KWS Conference
    • /
    • v.43
    • /
    • pp.67-69
    • /
    • 2004
  • The fuel assemblies as the nuclear fuel for the pressurized water reactor(PWR) are loaded in the reactor core throughout the residence time of three to five years. The spacer grid assembly, which is an interconnected array of slotted grid straps and is welded at the intersections to form an egg crate structure, is one of the main structural components of the fuel assembly. The spacer grid assembly is structurally required to have enough buckling strength under various kinds of lateral load acting on the fuel assembly so as to keep the fuel assembly straight. To meet the requirement, integrity on the spacer grid welding parts should be carefully checked. In this study, welding quality of the spacer grid assembly welded by several welding companies are examined and compared.

  • PDF

LVRT Scheme for Doubly Fed Induction Generator Systems Based on Flux Tracking Method (자속 추종을 통한 DFIG 시스템의 LVRT 기법)

  • Park, Sun-Young;Chun, Yeong-Han;Lee, Dong-Myung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1059-1065
    • /
    • 2013
  • Doubly Fed Induction Generator(DFIG) systems occupy the largest proportion of worldwide wind energy generation market. DFIG systems are very sensitive to grid disturbances especially to voltage dips due to the structure of the stator connected to grid. In the past, when a grid fault occurs generators are separated from grid(trip method) in order to protect the systems. Nowadays, due to the growing penetration level of wind power, many countries have made some requirements that wind turbines are required to have Low Voltage Ride Through(LVRT) capability during grid faults. In this paper, a flux tracking LVRT control strategy based on system modeling equations is proposed. The validity of the proposed strategy is verified through computer simulations.

Design of Multi-Input Multi-Output Positive Position feedback Controller based on Block-Inverse Technique (블록 역행렬 기법에 의한 다중입출력 양변위 되먹임제어기의 설계)

  • Kwak, Moon-K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.508-514
    • /
    • 2005
  • This paper is concerned with the active vibration control of a grid structure equipped with piezoceramic sensors and actuators. The grid structure is a replica of the solar panel commonly mounted on satellites, which contains complex natural mode shapes. The multi input and multi output positive position feedback controller is considered as an active vibration controller for the grid structure. A new concept, the block-inverse technique, is proposed to cope with more modes than the number of actuators and sensors. This study also deals with the stability and the spillover effect associated with the application of the multi-input multi-output positive position feedback controller based on the block inverse technique. It was found that the theories developed in this study are capable of predicting the control system characteristics and its performance. The new multi-input multi-output positive position feedback controller was applied to the test structure using a digital signal processor and its efficacy was verified by experiments..

  • PDF

Transflective liquid crystal display with single cell gap and simple structure

  • Kim, Mi-Young;Lim, Young-Jin;Jeong, Eun;Chin, Mi-Hyung;Kim, Jin-Ho;Srivastava, Anoop Kumar;Lee, Seung-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.340-343
    • /
    • 2008
  • This work reports the simple fabrication of the single cell gap transflective liquid crystal display (LCD) using wire grid polarizer. The nano sized wire grid polarizer was patterned on common electrode itself, on the reflective part of FFS (Fringe field switching) mode whereas the common electrode was unpatterned at transmissive part. However, this structure didn't show single gamma curve, so we further improved the device by patterning the common electrode at transmissive part. As a result, V-T curve of proposed structure shows single gamma curve. Such a device structure is free from in-cell retarder, compensation film and reflector and furthermore it is very thin and easy to fabricate.

  • PDF

Design of Multi-input Multi-output Positive Position Feedback Controller Based on Block-inverse Technique (블록 역행렬 기법에 의한 다중입출력 양변위 되먹임제어기의 설계)

  • Kwak, Moon K.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.9 s.102
    • /
    • pp.1037-1044
    • /
    • 2005
  • This paper is concerned with the active vibration control of a grid structure equipped with piezoceramic sensors and actuators. The grid structure is a replica of the solar panel commonly mounted on satellites, which contains complex natural mode shapes. The multi-input and multi-output positive position feedback controller is considered as an active vibration controller for the grid structure. A new concept, the block-inverse technique, is proposed to cope with more modes than the number of actuators and sensors. This study also deals with the stability and the spillover effect associated with the application of the multi-input multi-output positive position feedback controller based on the block-inverse technique. It was found that the theories developed in this study are capable of predicting the control system characteristics and its performance. The new multi-input multi-output positive position feedback controller was applied to the test structure using a digital signal processor and its efficacy was verified by experiments.

Numerical Requirements for the Simulation of Detonation Cell Structures (데토네이션 셀 구조 모사를 위한 수치적 요구 조건)

  • Choi Jeong-Yeol;Cho Deok-Rae
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.2
    • /
    • pp.1-14
    • /
    • 2006
  • Present study examines the numerical issues of cell structure simulation for various regimes of detonation phenomena ranging from weakly unstable to highly unstable detonations. Inviscid fluid dynamics equations with $variable-{\gamma} $ formulation and one-step Arrhenius reaction model are solved by a MUSCL-type TVD scheme and 4th order accurate Runge-Kutta time integration scheme. A series of numerical studies are carried out for the different regimes of the detonation phenomena to investigate the computational requirements for the simulation of the detonation wave cell structure by varying the reaction constants and grid resolutions. The computational results are investigated by comparing the solution of steady ZND structure to draw out the minimum grid resolutions and the size of the computational domain for the capturing cell structures of the different regimes of the detonation phenomena.

Design of tensegrity structures using artificial neural networks

  • Panigrahi, Ramakanta;Gupta, Ashok;Bhalla, Suresh
    • Structural Engineering and Mechanics
    • /
    • v.29 no.2
    • /
    • pp.223-235
    • /
    • 2008
  • This paper focuses on the application of artificial neural networks (ANN) for optimal design of tensegrity grid as light-weight roof structures. A tensegrity grid, 2 m ${\times}$ 2 m in size, is fabricated by integrating four single tensegrity modules based on half-cuboctahedron configuration, using galvanised iron (GI) pipes as struts and high tensile stranded cables as tensile elements. The structure is subjected to destructive load test during which continuous monitoring of the prestress levels, key deflections and strains in the struts and the cables is carried out. The monitored structure is analyzed using finite element method (FEM) and the numerical model verified and updated with the experimental observations. The paper then explores the possibility of applying ANN based on multilayered feed forward back propagation algorithm for designing the tensegrity grid structure. The network is trained using the data generated from a finite element model of the structure validated through the physical test. After training, the network output is compared with the target and reasonable agreement is found between the two. The results demonstrate the feasibility of applying the ANNs for design of the tensegrity structures.

Voltage Source Equipment for the Grid Fault Testing and Analysis of Total Harmonic Distortion According to PWM Methods

  • Gwon, Jin-Su;Kim, Chun-Sung;Kang, Dae-Wook;Park, Jung-Woo;Kim, Sungshin
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1081-1092
    • /
    • 2014
  • Renewable energy is being spotlighted as the electric power generating source for the next generation. Due to an increase in renewable energy systems in the grid system, their impact on the grid has become non-negligible. Thus, many countries in the world, including Europe, present their own grid codes for grid power conversion devices. In order to experiment with these grid codes, grid fault test equipment is required. This paper proposes both equipment and a control method, which are constructed with a 7-level cascaded H-bridge converter, that are capable of generating various grid faults. In addition, the Pulse Width Modulation (PWM) method for multilevel converters is compared and analyzed. The proposed structure, the control method, and the PWM method are verified through simulation and experimental results.

A Study of Automatically Authentication System for Virtual Resource Organization on Grid (그리드상의 가상 자원 조직에 대한 자동 인증 시스템 연구)

  • 최병선;이원구;이재광
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2004.05a
    • /
    • pp.301-306
    • /
    • 2004
  • The Grid VO(Virtual Organization) is temporary VO where gather indivisual, authority, or system resource, differ from previous VO concept that controled by internal principal and policy set. It have many problems in case of indivisuals, authorities, or system resources that became member\ulcorner of some Grid VO at same time and combination followed changing condition of system resource for building Grid VO. This paper propose lightweighted Grid VO authentication system based on XML security to solve the authentication of the problems occuring in building Grid VO. In this paper, Grid VO authentication system is including Grid VO authentication module that is intermediate management system in PH to previous authentication service structure and provide effective authentication service to Grid VO.

  • PDF

Crush Strength Analysis of a Spacer Grid for PWR Nuclear Fuel Considering Mechanical Properties in Weld Zone (용접부 기계적 물성치를 고려한 경수로 핵연료 지지격자의 충격해석)

  • Song, Kee-Nam;Lee, Sang-Hoon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.8 no.2
    • /
    • pp.7-13
    • /
    • 2012
  • A spacer grid which is one of the most important structural components in a pressurized water reactor fuel is an interconnected array of slotted grid straps, welded at the intersections to form an egg-crate structure. The spacer grid is required to not only protect fuel rods stably but also have sufficient lateral crush strength for the sake of enabling shut-down of the nuclear reactor during abnormal operating environments. Then, the lateral crush strength of the spacer grid is closely related with welding quality of the spacer grid. Previous research on the crush strength analysis of the spacer grid had been performed using only parent material properties. In this study, to investigate the effect on the crush strength of the spacer grid when used mechanical properties in weld zone instead of parent material properties, crush strength analysis considering mechanical properties in weld zone obtained from the instrumented indentation technique was performed and compared the results with the previous research.