• Title/Summary/Keyword: Grid connected

Search Result 1,222, Processing Time 0.033 seconds

A Phase Detection Method in Grid-Connected Converters using Oberber (관측기를 이용한 계통 연계형 컨버터에서 위상검출 방법에 대한 연구)

  • Kim, Young-Chun;Cho, Moon-Tack;Song, Ho-Bin;Kim, Ok-Hwan;Hong, Soon-Jik;Joo, Hae-Jong;Lee, Euy-Soo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.796-799
    • /
    • 2012
  • 직류전원장치에 사용되는 계통연계형 컨버터는 전원의 위상을 기준으로 제어되어야 하므로 하드웨어 또는 소프트웨어적인 다양한 방법들이 사용되고 있다. 이러한 방법들은 복잡하거나 노이즈에 의한 오동작 등의 위해요소를 내포하고 있다. 이에 본 논문에서는 관측기를 이용하여 전원의 주파수 변동에도 사용할 수 있는 강인한 위상점지 방법에 대해 제안하고 실험을 통해 입증하였다.

  • PDF

Analysis and study for MPPT algorithms in transformerless PV PCS (변압기 없는 태양광 PCS에서의 최대전력추종제어기법 분석)

  • Lee Kyung-Soo;Jung Young-Seck;So Jung-Hoon;Yu Gwon-Jong;Choi Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.606-609
    • /
    • 2004
  • Maximum power point tracking(MPPT) is usually used for a solar power system. Many maximum power tracking techniques have been considered in the past. The microprocessors with appropriate MPPT algorithms are favored because of their flexibility and compatibility with different solar arrays. In this paper, four MPPT algorithms are analyzed and studied. Perturbation and Observation(P&O), Incremental Conductance(IncCond), which are used from the past. Improved P&O and Two-mode , which are developed P&O and IncCond algorithms. Also, the author introduces grid-connected fransformerless PV PCS to apply MPPT control. MPPT efficiency is measured by changing irradiance from $0.1kW/m^2\;to\;1kW/m^2$ and simulation was performed for each MPPT algorithm.

  • PDF

Small Signal Modeling and Control Design of a Single-Phase Grid-Connected Inverter for the Phoovoltaic System (단상 계통 연계 태양광 인버터의 소신호 모델링 및 제어기 설계)

  • Lee, S.J.;Bae, H.S.;Choi, K.S.;Cho, B.H.
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.604-606
    • /
    • 2008
  • 본 논문에서는 단상 계통 연계 태양광 인버터의 소신호 모델링을 통한 체계적인 제어기 설계 방법을 제안한다. 계통 연계 태양광 인버터의 내부 전류제어기는 계통 전압과 동상이 되도록 계통 주입 전류를 제어하고, 외부 전압제어기의 태양전지 안정화 제어기를 통해 태양전지의 최대전력점 추적제어를 수행한다. 태양전지의 전 동작 영역에서 안정적인 동작 수행과 계통주입 전류 제어를 위한 태양전지 전압 제어기 및 인버터 전류제어기의 안정도 해석 및 설계 방법을 소신호 모델링을 통해 제시한다. 본 연구에 제안된 방법은 200W급 태양전지를 이용한 축소 시스템을 이용하여 검증한다.

  • PDF

Sine Reference Tracking State Feedback Current Controller for the Grid-connected Inverter using the Pole Placement Technique (극점배치기법을 이용한 계통 연계형 인버터의 사인입력 기준전압 추적 상태궤환 전류제어기)

  • Bae, H.S.;Lee, S.J.;Choi, K.S.;Cho, B.H.
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.607-609
    • /
    • 2008
  • 본 논문에서는 태양광 발전 및 연료전지 시스템에서 사용되는 계통 연계형 인버터에 적용 가능한 새로운 전류제어기 설계방법을 제안한다. 제안된 상태궤환 전류제어기는 극점배치기법을 이용하여 주어진 시스템 요구사항에 따른 체계적인 제어기설계가 가능하며, 계통 전압과 동상을 가지도록 계통 주입전류를 제어한다. 이에 따라, 사인입력 기준전압을 추적할 수 있는 상태궤환 제어 알고리즘을 인버터의 대신호 평균 모델을 이용하여 설계하고, 200W급 계통 연계형 2단 구조 태양광 발전 전력변환 축소 시스템의 실험을 통하여 그 성능을 검증한다.

  • PDF

Development of 10kW Grid-Connected Wind Power Generation Inverter (10kW급 풍력발전용 계통연계형 인버터의 개발)

  • Lee, Dong-Yup;Son, Yong-Hoon;Shin, Young-Chan;Park, Chan-Heung;Kim, Young-Roc
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.628-630
    • /
    • 2008
  • 국내에서 개발되어 판매되고 있는 풍력발전용 계통연계형 삼상 인버터는 대부분 대용량 인버터이다. 이 인버터의 경우 크기도 크고 설치하기가 어려워서 주로 발전 사업용으로 사용되고, 공장 및 산업현장에 설치하기에는 많은 단점을 가지고 있다. 본 논문에서는 이러한 단점을 해결하고 풍력발전의 보급을 위하여 소 용량 풍력발전용 계통연계형 삼상 인버터 시스템을 개발하였다.

  • PDF

Global Reference and Analysis of Wind Tubines Connected to Grid (계통연계 풍력발전의 해외 기준 분석 및 검토)

  • Choy, Young-Do;Kwak, No-Hong;Jeon, Young-Soo;Jeon, Dong-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.631-633
    • /
    • 2008
  • 현재 풍력발전 기술은 전 세계에서 가장 빠르게 성장하고 있는 기술로서 2010년도에 세계 보급량은 200GW를 넘을 것으로 추정되고 있다. 이에 우리나라도 풍력발전 기술 집약에 전력하고 있지만 풍력단지에 대한 운영 경험은 매우 제한적이며, 연계 기준 수립에 대한 기초가 부족한 실정이다. 따라서 한국계통의 특성을 고려한 연계 기준 및 최적 운영 방안 수립을 위한 다양한 국가에서 적용하고 있는 풍력 발전 단지에 대한 연계 및 운영 기준에 대한 검토가 필요한 실정이며 세계 각국에서 적용되고 있는 풍력 발전기의 계통 연계 기준을 분석 및 검토하였다.

  • PDF

Variable Step-Size MPPT Control based on Fuzzy Logic for a Small Wind Power System (소형풍력발전시스템을 위한 퍼지로직 기반의 가변 스텝 사이즈 MPPT 제어)

  • Choi, Dae-Keun;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.205-212
    • /
    • 2012
  • This paper proposes the fuzzy logic based variable step-size MPPT (Maximum Power Point Tracking) method for the stability at the steady state and the improvement of the transient response in the wind power system. If the change value of duty ratio is set on stability of the steady state, MPPT control traces to maximum power point slowly. And if the change value is set on improvement of the transient response, the system output oscillates at the maximum power point. By adjusting the step size with fuzzy logic, it can be improved the MPPT response speed and stability at steady state when MPPT control is performed to track the maximum power point. The effectiveness of the proposed method has been verified by simulations and experimental results.

Transformer-Less Single-Phase Four-Level Inverter for PV System Applications

  • Yousofi-Darmian, Saeed;Barakati, Seyed Masoud
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1233-1242
    • /
    • 2014
  • A new inverter topology for single-phase photovoltaic (PV) systems is proposed in this study. The proposed inverter offers a four-level voltage in its output terminals. This feature results in easier filtering in comparison with other conventional two-level or three-level inverters. In addition, the proposed four-level inverter (PFLI) has a transformer-less topology, which decreases the size, weight, and cost of the entire system and increases the overall efficiency of the system. Although the inverter is transformer-less, it produces a negligible leakage ground current (LGC), which makes this inverter suitable for PV grid-connected applications. The performance of the proposed inverter is compared with that of a four-level neutral point clamped inverter (FLNPCI). Theoretical analysis and computer simulations verify that the PFLI topology is superior to FLNPCI in terms of efficiency and suitability for use in PV transformer-less systems.

A Fuzzy Logic Controller Design for Maximum Power Extraction of Variable Speed Wind Energy Conversion System (가변 풍력발전 시스템의 최대출력 제어를 위한 Fuzzy 제어기 설계)

  • Kim Jae-gon;Huh Uk-youl;Kim Byung-yoon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.11
    • /
    • pp.753-759
    • /
    • 2004
  • This paper presents a modeling and simulation of a fuzzy controller for maximum power extraction of a grid-connected wind energy conversion system with a link of a rectifier and an inverter. It discusses the maximum power control algorithm for a wind turbine and proposes, in a graphical form, the relationships of wind turbine output, rotor speed, power coefficient, tip-speed ratio with wind speed when the wind turbine is operated under the maximum power control. The control objective is to always extract maximum power from wind and transfer the power to the utility by controlling both the pitch angle of the wind turbine blades and the inverter firing angle. Pitch control method is mechanically complicated, but the control performance is better than that of the stall regulation method. The simulation results performed on MATLAB will show the variation of generator's rotor angle and rotor speed, pitch angle, and generator output.

High frequency Linked Grid-Connected PV System for Residential Use (고주파링크 방식의 계통연계형 태양광발전시스템)

  • Jung, Y.S.;Yu, G.J.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1281-1283
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors a net size, weight, and parts cost saying result compared to the other systems due to elimination of 60Hz transformer.

  • PDF