• Title/Summary/Keyword: Grid Effect

Search Result 906, Processing Time 0.029 seconds

An Optimization Method for the Calculation of SCADA Main Grid's Theoretical Line Loss Based on DBSCAN

  • Cao, Hongyi;Ren, Qiaomu;Zou, Xiuguo;Zhang, Shuaitang;Qian, Yan
    • Journal of Information Processing Systems
    • /
    • v.15 no.5
    • /
    • pp.1156-1170
    • /
    • 2019
  • In recent years, the problem of data drifted of the smart grid due to manual operation has been widely studied by researchers in the related domain areas. It has become an important research topic to effectively and reliably find the reasonable data needed in the Supervisory Control and Data Acquisition (SCADA) system has become an important research topic. This paper analyzes the data composition of the smart grid, and explains the power model in two smart grid applications, followed by an analysis on the application of each parameter in density-based spatial clustering of applications with noise (DBSCAN) algorithm. Then a comparison is carried out for the processing effects of the boxplot method, probability weight analysis method and DBSCAN clustering algorithm on the big data driven power grid. According to the comparison results, the performance of the DBSCAN algorithm outperforming other methods in processing effect. The experimental verification shows that the DBSCAN clustering algorithm can effectively screen the power grid data, thereby significantly improving the accuracy and reliability of the calculation result of the main grid's theoretical line loss.

Unstructured Pressure Based Method for All Speed Flows (전 속도영역 유동을 위한 비정렬격자 압력기반해법)

  • Choi, Hyung-Il;Lee, Do-Hyung;Maeng, Joo-Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1521-1530
    • /
    • 2002
  • This article proposes a pressure based method for predicting flows at all speeds. The compressible SIMPLE algorithm is extended to unstructured grid framework. Convection terms are discretized using second-order scheme with deferred correction approach. Diffusion term discretization is based on structured grid analogy that can be easily adopted to hybrid unstructured grid solver. This method also uses node centered scheme with edge based data structure for memory and computing time efficiency of arbitrary grid types. Both incompressible and compressible benchmark problems are solved using the above methodology. The demonstration of this method is extended to slip flow problem that has low Reynolds number but compressibility effect. It is shown that the proposed method can improve efficiency in memory usage and computing time without losing any accuracy.

Shape Modification for Decreasing the Spring Stiffness of Double-plated Nozzle Type Spacer Grid Spring (이중판 노즐형 지지격자 스프링의 지지 강성감소를 위한 형상 개선)

  • Kang, H.S.;Song, K.N.;Lee, J.H.;Lee, K.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.400-405
    • /
    • 2001
  • Nozzle of the double-plated grid plays the role of the spring to support a fuel rod as well as to provide the coolant path in grid. The nozzle was known to be necessary to reduce the spring stiffness for supporting performance. In this study the contact analysis between the fuel rod and the nozzle type spacer grid was performed by using ABAQUS standard to propose the preferable shape in tenn of spring performance. Two small cuts at the upper and lower part of the nozzle appeared to have a minor effect in decreasing the nozzle stiffness. A long slot at the center of the nozzle was turned out not only to decrease the spring constant as desired but also to increase the elastic displacement.

  • PDF

Grid Connected PV System with a Function to Suppress Disturbances caused by Solar-cell Array Instantaneous Output Power Fluctuation (태양전지어레이 순시 출력변동에 의한 외란의 억제기능을 갖는 계통연계형 태양광발전 시스템)

  • Kim, Hong-Sung;Choe, Gyu-Ha;Yu, Gwon-Jong
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.63-69
    • /
    • 1999
  • The conventional grid connected PV(Photovoltaic) system has a unstable output pattern due to its dependence on the weather condition, although solar-cell array averagely has a regular output characteristics to have a peak output nearly at noon. Therefore assuming the high density grid connection in the future, this unstable output pattern can be one of the main reasons to generate power disturbance such as voltage variation, frequency variation and harmonic voltage generation in low voltage distribution line. However general grid connected solar-cell system do not have functions to cope with these disturbances. Therefore this study proposed a advanced type grid connected PV system with functions to suppress output power fluctuation due to solar-cell array output variation and showed the levelling effect of fluctuation due to instantaneous array output variation.

  • PDF

THE MICROWAVE ABSORBING CHARACTERISTICS OF FERRITE GRID ABSORBER

  • Kwon, H.J.;Shon, H.J.;Hur, W.D.;Naito, Yoshiyuki;Takahashi, Michiharu
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.805-809
    • /
    • 1995
  • In order to widen the band-width of ferrite absorber, compositional effect on the complex permeability of Ni-Zn ferrite and the structure of grid absorber were studied. From the experimental results, we could determine the optimum composition composition of Ni-Zn ferrite and the structure of grid absorber. Also, we manufactured grid absorber and investigated its microwave absorbing characteristics. Calculation shows that the ferrite frid absorber suppresses reflection ${\leq}-20dB$ from 30 MHz to 700 MHz and the conventional ferrite tile absorber suppresses reflection ${\leq}20dB$ in the frequency range of 30 MHz-400 MHz. It was found that the microwave absorbing performance of the ferrite grid absorber was superior to the ferrite tile absorber.

  • PDF

Electrical Automatic Control System Based on the Internet of Things

  • Jiyong, Jin
    • Journal of Information Processing Systems
    • /
    • v.18 no.6
    • /
    • pp.784-793
    • /
    • 2022
  • Grid-connected distributed power generation has been widely used in green energy generation. However, due to the distributed characteristics, distributed power generation is difficult to be dynamically allocated and monitored in the electrical control process. In order to solve this problem, this research combined the Internet of Things (IoT) with the automatic control system of electrical engineering to improve the control strategy of the power grid inverter according to the characteristics of the IoT system. In the research, a connection system of the power grid inverter and the IoT controller were designed, and the application effect was tested by simulation experiments. The results showed that the power grid inverter had strong tracking control ability for current and power control. Meanwhile, the electrical control system of the IoT could independently and dynamically control the three-phase current and power. The given value was reached within 50 ms after the step signal was input, which could protect the power grid from being affected by the current. The overall system could realize effective control, dynamic control and protective control.

CFD PARAMETRIC STUDY FOR 2D WATER ENTRY

  • Lee, H.H.;Rhee, S.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.191-195
    • /
    • 2009
  • A parametric study for for the water entry of a two dimensional symmetric wedge with deadrise angle of 10 degrees was carried out to find out the most dominant parameter. Water entry problem with constant velocity is simplified as the stationary wedge in the way of the upcoming water surface. The calculated impact loads showed that the effect of the viscosity was not so important in this problem. For a given grid system a suitable time step size can be found. The most sensitive parameter was found to be the grid size.

  • PDF

Ag Grid를 이용한 플렉시블 투명 전극의 투명 안테나 특성 연구

  • Jo, Chung-Gi;Kim, Han-Gi
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.27.2-27.2
    • /
    • 2011
  • 본 연구에서는 저저항/고투과 플렉시블 투명 전극 개발을 위해 금속 그리드가 적용된 투명 전극을 개발하였다. Lift off 공정을 도입하여 플렉시블 PET 기판 위에 Ag grid를 성막하고 이후 연속 공정이 가능한 Roll-to-Roll sputtering system을 이용하여 최적화된 ITO(40nm)/Ag(12nm)/ITO(40nm) 다층 투명 전극을 성막하였다. 제작된 플렉시블 투명 전극의 전기적, 광학적, 구조적 특성 및 기계적/전기적 안정성 평가를 위해 four-point probe measurement, Hall effect measurement, UV/Vis spectrometer, scanning electron microscopy 및 bending tester를 이용하여 각각의 특성을 분석하였다. Ag grid가 적용된 ITO/Ag/ITO 투명 전극에서 Ag의 배선 간격이 0.75 mm일 때 0.18 ohm/sq. 의 낮은 면 저항과 가시광선 영역에서 80% 이상의 높은 투과율을 나타내었으며, 이러한 저저항 및 고투과율 특성으로 인해 최적화된 배선 간격 0.75 mm에서 $538.11{\times}10^{-3}\;ohm^{-1}$의 매우 높은 figure of merit ($T^{10}/R_{sh}$) 값을 확보할 수 있었다. 기계적 응력에 따른 전기적 안정성 특성 분석 결과 5,000회 이상의 bending cycle 에서도 초기 저항 값과 유사한 전기적 특성을 나타냄으로써 Ag grid가 적용된 ITO/Ag/ITO 플렉시블 투명 전극의 기계적 응력에 따른 전기적 안정성을 확인할 수 있었다. Ag grid가 적용된 ITO/Ag/ITO 투명 전극의 투명 안테나 적용 가능성을 타진하기 위해 low band 및 high band 영역에서의 안테나 효율을 측정하였으며, 모든 영역에서 상용화된 copper 안테나와 유사한 효율을 나타내었다. Ag grid를 이용한 플렉시블 투명 전극의 저저항/고투과율 특성은 플렉시블 광전소자의 투명 안테나로의 적용 가능성을 나타낸다.

  • PDF

The Grid Strap Vibration Characteristics of the 5×5 Nuclear Fuel Mock-up (5×5 핵연료 모의 집합체의 지지격자 스트랩 진동특성)

  • Kim, Kyoung-Hong;Park, Nam-Gyu;Kim, Kyoung-Ju;Suh, Jung-Min
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.7
    • /
    • pp.619-625
    • /
    • 2012
  • Since the fuel is always exposed to turbulent flow, the grid strap shows flow induced vibration characteristics that impact on the nuclear fuel soundness. The dynamic behavior of grids in nuclear fuels is quite complex, since two pairs of spring and dimple support are contacted with rods by friction in the limited space. This paper focuses on investigation of the grid strap(test fuel strap, TFS) vibration in one cell. TFS consists of a single spring and double dimples. To identify the grid strap vibration, modal analysis of the strap is performed using finite element method(FEM). Modal testing on a $5{\times}5$ grid structure without rods is performed. The modal testing results are compared to analytic results. In addition, random test considering rod effect is performed about a $5{\times}5$ grid with rods under real contact condition in the air. Finally, the strap vibration of a $5{\times}5$ fuel bundle in investigation of flow induced vibration(INFINIT) facility is measured in real fluid velocity condition without heating. It is shown that modal frequencies from the test are almost equal to those peak frequencies in the INFINIT test.

Multi-Objective Optimal Predictive Energy Management Control of Grid-Connected Residential Wind-PV-FC-Battery Powered Charging Station for Plug-in Electric Vehicle

  • El-naggar, Mohammed Fathy;Elgammal, Adel Abdelaziz Abdelghany
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.742-751
    • /
    • 2018
  • Electric vehicles (EV) are emerging as the future transportation vehicle reflecting their potential safe environmental advantages. Vehicle to Grid (V2G) system describes the hybrid system in which the EV can communicate with the utility grid and the energy flows with insignificant effect between the utility grid and the EV. The paper presents an optimal power control and energy management strategy for Plug-In Electric Vehicle (PEV) charging stations using Wind-PV-FC-Battery renewable energy sources. The energy management optimization is structured and solved using Multi-Objective Particle Swarm Optimization (MOPSO) to determine and distribute at each time step the charging power among all accessible vehicles. The Model-Based Predictive (MPC) control strategy is used to plan PEV charging energy to increase the utilization of the wind, the FC and solar energy, decrease power taken from the power grid, and fulfil the charging power requirement of all vehicles. Desired features for EV battery chargers such as the near unity power factor with negligible harmonics for the ac source, well-regulated charging current for the battery, maximum output power, high efficiency, and high reliability are fully confirmed by the proposed solution.