• 제목/요약/키워드: Greenhouse cooling

검색결과 177건 처리시간 0.029초

Heating and Cooling System for Utilization of Surplus Air Thermal Energy in Greenhouse and its Control Logic

  • Yang, Seung-Hwan;Lee, Chun-Gu;Lee, Won-Kyu;Ashtiani, Alireza Araghi;Kim, Joon-Yong;Lee, Sang-Deok;Rhee, Joong-Yong
    • Journal of Biosystems Engineering
    • /
    • 제37권1호
    • /
    • pp.19-27
    • /
    • 2012
  • Purpose: Utilizing air thermal energy during over-heated time in the greenhouse is a necessary component to save greenhouse heating costs for nighttime. However, there is no practical way to implement the related principles. Methods: In this study, a heating and cooling system which utilizes the surplus air thermal energy in a greenhouse was developed. Available air thermal energy and heating load for this experimental glasshouse were estimated based on temperature conditions of the plant growth and weather data. Results: Estimated values were 400 MJ/day for maximum surplus air thermal energy and 340 MJ/day for maximum heating energy which were target values of the design as well. The system consists of a heat pump, fan-coil units and heat storage tanks which are divided into low and high temperature tanks. Moreover, a new control logic was developed for surplus air thermal energy utilization. Conclusions: This paper explains the details of conceptual design process of the system. Results of test operations showed that the developed system performed the recovery and supply of the thermal energy according to design purposes.

국내 온실재배의 적지성 분석을 위한 Climagraph의 작성과 이용 (Design and Utilization of climagraph for Analysis of Regional Suitability of Greenhouse Cropping in Korea)

  • 이현우;이석건;이종원
    • 생물환경조절학회지
    • /
    • 제9권2호
    • /
    • pp.107-114
    • /
    • 2000
  • 우리나라의 주요지역에 대하여 일최저기온의 월평균값, 일최고기온의 월평균값, 전천일사량의 월평균값을 사용하여 외기온과 전천일사랑과의 관계를 도시하고, 온실의 형태와 작물의 종류에 따른 한계 최저외기온 및 한계 최고외기온을 산정하여 Climagraph를 작성하였다. 이 그래프를 이용하면 지역별로 냉난방설비를 이용하지 않고 온실재배가 가능한 기간을 결정할 수 있을 뿐만 아니라 각종의 온실재배작물을 재배하기에 적절한 지역을 선정하는데 이용될 수 있고, 지역별 기후특성 분석, 지역별 온실특성의 규명, 작물의 생육환경 추정 및 조절, 온실작물생산의 합리적인 계획등을 위한 도구로도 이용될 수 있을 것이다. 본 연구를 수해하면서 climagraph를 작성하는데 필요한 명확한 자료를 구하기가 상당히 어려웠기 때문에 이러한 그래프를 국내의 온실재배에 효율적으로 이용하기 위해서는 많은 추가적인 연구가 필요할 것으로 판단되었다. 특히 난방과 냉방기간을 결정함에 있어 경계시기를 결정하는데 필요한 구체적인 자료를 구하기가 어려웠으며, 작물별 생육에 필요한 한계 최저회부일사랑을 결정 하는데 어려움이 있었다.

  • PDF

시설원예를 위한 수평형 지열 히트펌프의 냉방성능 해석 (Cooling Performance of Horizontal Type Geothermal Heat Pump System for Protected Horticulture)

  • 유영선;강연구;강금춘;김영중;백이
    • 생물환경조절학회지
    • /
    • 제17권2호
    • /
    • pp.90-95
    • /
    • 2008
  • 수직형에 비해 비교적 가격이 저렴하고 냉난방을 동시에 할 수 있는 농업시설에 적합한 10RT 규모의 수평형 지열히트펌프 시스템을 $240m^2$ 면적의 온실에 설치하고, 이 시스템의 냉방성능을 분석하였다. 응축기 출구온도가 $40^{\circ}C$에서 $58^{\circ}C$로 상승함에 따라 소비전력은 11.5kW에서 15kw로 상승하였으며, 고압이 1,617kpa에서 2,450kPa로 변화하였다. 냉방성능계수는 지중온도 $25.5^{\circ}C$에서 2.7 수준이었으며 지온이 상승함에 따라 하강하여 $33.5^{\circ}C$에서 2.0 수준이었다. 또한 온실 내부로부터 흡수하는 열량(냉방열량)은 같은 지중온도 수준에서 각각 28.8kW, 26.5kW이었다. 가동 8시간 후 지열교환기가 설치된 60cm깊이의 지온은 $14.3^{\circ}C$가 상승하였으며 150cm는 $15.3^{\circ}C$가 상승하였다. 반면 지열교환기가 매설되지 않은 60cm 깊이는 2.4, 150cm 깊이는 $4.3^{\circ}C$의 지온상승을 보였다. 열매 체유가 지열교환기를 통과한 후 평균 $7.5^{\circ}C$의 온포가 하강하였으며, 토양온도가 평균 $27.5^{\circ}C$ 수준에서 토양으로 방출하는 열량은 평균 46kw로 지중열교환기의 단위 길이 당 약 36.8W의 열량을 방출하는 것으로 분석되었다. 팬코일 유닛이 온실로부터 흡수하는 냉방 열량은 평균 28.2kW이었으며, 열매체유의 온도는 $4.2^{\circ}C$ 상승하였다. 축열조내 열전달매체유의 온도가 $26.0^{\circ}C$에서 $2.0^{\circ}C$까지 하강하는데 3시간이 소요되었으며, 평균 축열율은 29.7kW, 총 축열량은 321MJ이었다. 또한 $2.0^{\circ}C$까지 냉열을 축열한 후 $25.4^{\circ}C$까지 방열되는 시간은 외기온이 평균 $28.5^{\circ}C$일 때 4시간이었고, 총 313.0MJ의 에너지가 방열되었으며, 이때 평균 방열율은 21.7kW인 것으로 분석되었다.

가정용 열병합 시스템의 국내 도입에 따른 온실가스 저감효과 예측 (Impact of Residential CHP Systems on Greenhouse Gas Emissions in Korea)

  • 강병하;윤창호;안준
    • 설비공학논문집
    • /
    • 제25권10호
    • /
    • pp.555-561
    • /
    • 2013
  • The effects of applying the micro CHP system to the domestic sector in Korea were investigated using annual cooling and heating demand data. Four prime movers, micro gas turbine, PEMFC, gas engine and Stirling engine, were compared for three operational modes. Two way buy-back was assumed for both electricity and heat. The Stirling engine gave the lowest $CO_2$ emission per energy for 300kWh monthly electricity production. However, PEMFC became more effective when considering PURPA criteria. PEMFC generated the least greenhouse gas with higher electrical efficiency for cooling. The Stirling engine, however, became competitive for heating with higher total efficiency.

토마토 재배 온실의 환경조절에 따른 온습도 균일도 분석 (Analysis on the Uniformity of Temperature and Humidity According to Environment Control in Tomato Greenhouses)

  • 남상운;김영식
    • 생물환경조절학회지
    • /
    • 제18권3호
    • /
    • pp.215-224
    • /
    • 2009
  • 공기유동 제어기술의 개발을 위한 기초자료를 제공 할 목적으로 토마토 재배 온실의 냉난방과 환기 및 공기유동 관련 실태를 조사하고, 온실유형과 난방방식별 온습도 분포를 실측하여 균일도를 분석하였다. 충남 부여 세도지역의 토마토 재배 온실 136농가를 대상으로 조사한 결과 대부분을 차지하는 단동 플라스틱 온실의 천창 설치 비율이 낮고 환기팬과 유동팬 설치비율도 매우 낮을 뿐만 아니라 설치제원도 편차가 매우 큰 것으로 나타났다. 아치형 단동 플라스틱온실의 천창 환기 구조의 개발보급과 연동곡부의 천창도 지붕상부로 이동시킬 필요가 있으며, 개별 천창구조 및 환기팬과 유동팬에 대한 설치 가이드라인의 제정이 요구된다. 냉방설비를 설치한 농가는 하나도 없었으며 난방방식의 대부분을 차지하는 온풍난방에서 덕트의 설치제원 역시 편차가 큰 것으로 나타났고, 온풍덕트의 배기풍속 및 배기온도 또한 거리에 따른 편차가 매우 큰 것으로 관측되었다. 수출경쟁력 화보를 위한 고품질의 생산물을 연중 안정적으로 생산하기 위해서는 온실냉방기술의 보급이 절실하며 난방방식이나 덕트설치 방식의 개선이 필요한 것으로 판단된다. 온실내 온습도 분포가 균일한지 여부를 판단하는 지표로 사용되고 있는 최대 편차와 실제 균등한 정도를 나타낼 수 있는 균일도와의 관계를 분석해 본 결과 높은 상관관계를 보였으나 주간에는 직선식으로 야간에는 2차 곡선식으로 다르게 표현되었다. 온습도 분포의 균일한 정도를 판정할 수 있는 객관적인 기준이 마련된다면 최대편차 대신 균일도를 지표로 사용하는 것이 더 합리적일 것으로 판단된다. 온실유형과 난방방식에 따라 온 습도분포의 균일도가 상당히 다른 것을 확인할 수 있었으며 야간에는 온수난방의 경우 이랑배관으로, 온풍난방의 경우 온풍덕트의 적절한 배치를 통하여, 주간에는 환기와 공기유동을 통하여 균일도를 개선할 수 있을 것으로 판단되었다.

포그냉방 온실에서 측창개폐수준이 온습도 제어에 미치는 영향 (Effects of the Open Level of the Side Window on the Control of the Temperature and Relative Humidity in the Fog Cooling Greenhouse)

  • 김영복;성현수;윤남규;이시영;황승재;김현태;이장평
    • 농업생명과학연구
    • /
    • 제45권6호
    • /
    • pp.265-278
    • /
    • 2011
  • 하절기 온실 내 온도와 상대습도를 동시에 제어할 목적으로 압축공기를 이용한 이류체 분무 포그 냉방을 도입한 유리온실에서 측창의 개폐수준이 온실내의 온도와 상대습도 제어에 어떠한 영향을 주는지 분석하였다. 제어과정은 온실 환경변수들을 측정하고, 이를 반영하여 온실 내 수분평형방정식과 열평형방정식을 정립한 다음, 이 방정식들을 프로그램으로 코딩하여 각 사이클의 천창 개폐량과 포그 분무량을 결정하고 제어하였다. 온실의 온습도 제어목표는 온도와 습도를 각각 28, 75%로 설정하였고, 실험은 측창이 전혀 열리지 않은 0%, 50% 열린 경우, 100% 열린 경우 세 가지 모드를 비교분석하였다. 제어실험결과 온실 내 건구온도의 평균은 모드에 따라 각각 28.2, 27.2 $26.3^{\circ}C$로 나타났으며, 표준편차는 $0.4{\sim}0.8^{\circ}C$이었다. 상대습도는 측창을 완전히 닫은 모드인 0%의 경우 평균 76.3% 정도로서 목표 상대습도인 75%에 상당히 근접해서 제어되고 있었으며, 표준편차가 2.1%로서 다른 모드에 비해 상당히 안정된 범위에서 유지되는 것으로 나타났다. 0%의 모드에서 가장 목표온도로 잘 제어되고 있는 것으로 나타났다.

저압 에어포그 시스템을 설치한 온실의 냉방효율 (Cooling Efficiency of Low Pressure Compressed Air Fogging System in Naturally Ventilated Greenhouses)

  • 남상운;김영식;성인모;고기혁
    • 한국농공학회논문집
    • /
    • 제54권5호
    • /
    • pp.49-55
    • /
    • 2012
  • In order to derive the efficient utilization of low pressure compressed air fogging system, cooling efficiencies with control types were analyzed through cooling experiments in tomato greenhouses. The control types were set up with temperature control, humidity control, temperature and humidity control, and time control. It showed that the cooling effects were 0.7 to $3.3^{\circ}C$ on average and maximum of 4.3 to $7.0^{\circ}C$, the humidification effects were 3.5 to 13.5 % on average and maximum of 14.3 to 24.4 %. Both the cooling and humidification effect were the highest in the time control method. The cooling efficiency of the air fogging system was not high with 8.3 to 27.3 % on average. However, the cooling efficiency of 24.6 to 27.3 % which appears from the time control is similar to the cooling efficiency of high pressure fogging system experimented in Japan. The air fogging system is operated by low pressure, but its efficiency is similar to high pressure. We think because it uses compressed air. From this point of view, we suggest that the air fogging system can get the cooling efficiency of similar levels to that of high pressure fogging system and it will have an advantage from clogging problem of nozzle etc.