• 제목/요약/키워드: Greenhouse

검색결과 5,171건 처리시간 0.04초

지하공기-물 직접접촉식 열교환기를 구비한 히트펌프의 성능 (Performance of Underground Air-to-Water Heat Pump with Direct Contact Heat Exchanger)

  • 김영화;강연구;성문석;유영선;김종구;장재경
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.172.1-172.1
    • /
    • 2010
  • In Jeju, underground air is used for heating greenhouse and fertilizing natural $CO_2$ gas by suppling directly into greenhouse. But greenhouse heating method by direct supply of underground air has several problems as like low temperature below $20^{\circ}C$ or high relative humidity over 90%. The underground air is inadequate in heating of crops such as mangos, oranges with the growing temperature over $20^{\circ}C$. Also if the relative humidity of greenhouse is kept with over 90%, diseases can strike almost of the crops. And also the ventilation loss becomes larger because the air pressure of inside greenhouse by direct supply of underground air is higher. In this study the heat pump system using underground air as heat source was developed and heating performance of the system was analyzed. Heating COP of the system was 2.5~5.0 and rejecting heat into greenhouse and extracting heat from underground air in this heat pump system were 46.5~31.4 kW, 34.9~20.9 kW respectively.

  • PDF

시설원예용 플라스틱 하우스의 태풍피해에 관한 연구 (A Study on the Typhoon Disaster of Greenhouse)

  • 윤용철;서원명;윤충섭
    • 생물환경조절학회지
    • /
    • 제4권2호
    • /
    • pp.167-174
    • /
    • 1995
  • This study was carried out to find a way of improving the windproof capability of greenhouse foundations. Generally, greenhouses are often collapsed due to the strong winds, because they are very light weight structures. In such a critical situations, the foundations are very often subjected to uplift and vibration at the same time. This paper describes both the wind disaster of greenhouses by the typhoon FAEY and the uplift resistance of greenhouse foundations. Followings are the results obtained from this study ; Judging from the view point of year round cultural aspects, it is recommended that some measures be taken for the preventions of greenhouse film ruptures because greenhouse structural damages are found to be directly associated with the local rupture of cover film. In the case of surveyed area, movable pipe-houses or pipe-houses of 1-2W type were found to be completely destroyed when the maximum instantaneous wind velocity was over 30m/sec or so. In the case of movable pipe-houses, the uplift resistance of greenhouse was expected to increase with the increase of pipe diameter and/or the embedment pipe length. But at present situations there is a limitation in raising the uplift resistance of movable pipe-house, because pipe diameters as well as pipe lengths customarily selected by farmers are quite a much limited.

  • PDF

열펌프에 의한 그린하우스 난방시스템의 열특성과 시뮬레이션 모델개발 (Thermal Characteristics and Simulation Model Development for Greenhouse Heating System with Heat Pump)

  • 노정근;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제26권2호
    • /
    • pp.155-162
    • /
    • 2001
  • The greenhouse heating system with heat pump was built for development of simulation model and validation. The computer simulation model for the system to predict temperature of air and soil and moisture content of soil in the greenhouse were developed, and its validity was justified by actual data. From the analysis of experimentally measured data and the simulation output, following results were obtained. 1. The expected values of inside air temperature for the heating system with heat pump were very much close to the experimental values. 2. In the heating system with heat pump, the expected values of day time surface temperature of soil by computer simulation were very much similar to the measured values, but those of night time were higher than the measured value by at most 2.0$\^{C}$. 3. The simulation model predicted temperature of greenhouse film as of 1$\^{C}$ below than the mean value of ambient air and greenhouse air temperature. 4. Heat loss value of daytime was found to be larger than that of nigh as much as 1.3 to 2.3 times for the heating system with heat pump. 5. In the heating system with heat pump, when the lowest ambient temperature was -8$\^{C}$∼-7$\^{C}$ the air temperature of greenhouse was 5$\^{C}$∼6$\^{C}$, thus the heat pump heating system contributed in greenhouse heating by 13$\^{C}$.

  • PDF

산성비, 오존층, 온실 효과에 대한 고등학생들의 개념 (The Conceptions of High School Students about Acid Rain, Ozone Layer, and Greenhouse Effect)

  • 한재영;정영선;노태희
    • 한국과학교육학회지
    • /
    • 제20권3호
    • /
    • pp.364-370
    • /
    • 2000
  • 본 연구에서는 산성비, 오존층, 온실 효과에 대한 학생들의 개념을 조사하였다. 고등학교 1학년 137명을 대상으로 세 가지 개념과 이들 사이의 관계에 대한 생각을 주관식 검사를 통해 알아보았다. 학생들의 응답을 분석한 결과, 학생들은 산성비의 정의, 온실 효과와 지구 온난화의 구분, 온실 효과의 증가 억제 방법 등에 대하여 잘 이해하지 못하는 것으로 나타났다. 또한 오존층을 온실 효과와 혼동하고 있었다. 산성비의 증가, 오존층의 파괴, 온실 효과의 증가 사이에 인과 관계가 있다고 생각하는 학생들이 많았다.

  • PDF

원적외선 면상발열체에 의한 온실 난방시스템의 열특성 분석 (Thermal Energy Characteristics for Greenhouse Heating System with Far-Infrared Heater)

  • 노정근;김희준;리혁;한충수;조성찬
    • Journal of Biosystems Engineering
    • /
    • 제31권6호
    • /
    • pp.529-534
    • /
    • 2006
  • The greenhouse heating system with far-infrared heater was built to analyze various thermal characteristics, such as greenhouse air temperature, soil temperature, energy flow, energy consumption in far-infrared heater, and other factors, which could be used in comparison with other greenhouse heating system in this study. The results showed that the inside air temperature of the far-infrared greenhouse heating system was $5^{\circ}C$ higher than that of hot air heating system. Heat loss of daytime was found to be larger than that of night time as much as 44.8% for the heating system with far-infrared heater. In the heating system with far-Infrared heater, when the lowest ambient temperature was -8 $\sim$ -7$^{\circ}C$, the air temperature of greenhouse was 12 $\sim$ 15$^{\circ}C$, thus the far-infrared heating system was shown to be feasible for heating system. Energy consumption of far-infrared heating system was shown to be less than that of hot air heating system.

Micro-computer를 이용(利用)한 Greenhouse의 온도제어(溫度制御) System 개발(開發)에 관한 연구(硏究) (A Study on the Development of Greenhouse Temperature Control System by Using Micro-computer)

  • 서원명;민영봉;윤용철
    • Journal of Biosystems Engineering
    • /
    • 제15권2호
    • /
    • pp.134-142
    • /
    • 1990
  • This study was carried out for the development of greenhouse temperature control system by modifying an APPLE-II microcomputer attached with several interface systems. The interface systems are composed of 12 bit A/D converter, output port, multiplexer, time clock, etc. Under the operation of developed system, the greenhouse temperature was to be manipulated within the setting temperatures assumed to be appropriate for certain plant growth. The temperature control equimpents installed in the greenhouse are one-speed propeller type fan and two-phase electric heater, which are selectively started or stopped according to the control logic programmed in the control system. The results are summarized as follows : 1. The difference between two temperatures measured by the developed system and the self-recording thermometer calibrated with standard thermometer was less than $1^{\circ}C$. 2. When the temperature were measurd by 12 bit A/D converter and both electric heater and ventilation fan were controlled by developed ON/OFF logic, greenhouse temperature showed narrow fluctuation bands of less than $1^{\circ}C$ near the setting temperatures. 3. The temperature acquisition and control system developed in this study is expected to be applicable to environment control system such as greenhouse only by modifying the logic based on long term experimental data. 4. In order to reduce the measurement error and to increase the system control efficiency, it is recommended that continuous study should be carried out in the aspect of eliminating various systematic noises and improving the environmental control logic.

  • PDF

Analysis of Potential Reductions of Greenhouse Gas Emissions on the College Campus through the Energy Saving Action Programs

  • Woo, Jeongho;Choi, Kyoung-Sik
    • Environmental Engineering Research
    • /
    • 제18권3호
    • /
    • pp.191-197
    • /
    • 2013
  • Republic of Korea announced the reduction target to be around 30% of business as usual greenhouse gas emissions by 2020. College campuses were ranked at the 5th of high energy consumption areas in the building sectors. Target management scheme was designed to set greenhouse gas emissions target including several college campuses. Previous studies showed the amount of greenhouse gas emissions with several assumptions such as the applications of renewable energy systems and light emitting diode lamps, etc. Long-range Energy Alternatives Planning model was utilized to simulate future greenhouse gas emissions. This study sets standard model labs for energy saving action programs by applying guidance studies. It has been deduced that energy saving action programs was responsible for reducing 949.5 kWh for each standard model lab and the total reduction of all 59 model labs in the Engineering College building has been calculated to 56,020.5 kWh. The objective of the study is to provide guidelines on standard model laboratory for greenhouse gas emissions reduction on the campus.

강변여과수를 이용한 온실난방기술 개발 (Greenhouse Heating Technology Development by using Riverbank Filtration Water)

  • 문종필;이성현;권진경;강연구;유영선;이수장
    • 한국농공학회논문집
    • /
    • 제53권6호
    • /
    • pp.145-152
    • /
    • 2011
  • In order to heat greenhouse nearby river channel, riverbank filtration water source heat pump was developed for getting plenty of heat flux from geothermal energy. Recharging well, thermal storage tank with separating insulation plate and filtering tank for eliminating iron, manganese were mainly developed for making the coefficient of performance (COP) of heat pump higher. Heating system using riverbank filtration water source heat pump was installed at a paprika greenhouse in the Jinju region where a single fold of vinyl cover and 2 layers of horizontal thermal curtain were installed as a part of temperature keeping and heat insulation with a greenhouse area of 3,185 $m^2$. 320,000 kcal/h was supplied for performing a site application tests. A greenhouse heating test was performed from Feb. 1, 2011 to Apr. 30, 2011. As the result of that, COPh of the heat pump was measured in the range of 4.0~4.5, while COPS of the system was represented as 2.9~3.3. COP measured of the heat pump was very good and well responded to indoor heating temperature of the environment control system of a greenhouse.

비메탄계 휘발성유기화합물에 의한 간접 온실효과의 산출 (Estimation of Indirect Greenhouse Effect by Non-methane Volatile Organic Compounds)

  • 최은화
    • 한국환경과학회지
    • /
    • 제21권2호
    • /
    • pp.165-179
    • /
    • 2012
  • Indirect $CO_2$ effect due to non-methane volatile organic compound (NMVOC) emissions from solvent and product use and fugitive NMVOC emissions from fuels in the Republic of Korea and 13 Annex I countries under United Nations Framework on Climate Change were estimated and the proportions of them to total greenhouse gas (GHG) emissions ranged from 0.092% to 0.45% in 2006. Indirect greenhouse effect ($CO_2$, $CH_4$, and $O_3$) were estimated at 13 photochemical assessment monitoring sites in the Republic of Korea using concentrations of 8 NMVOCs of which indirect global warming potential (GWP) were available. The contribution of toluene to mixing ratio was highest at 11 sites and however, the contribution of toluene to indirect greenhouse effect was highest at nine sites. In contrast to toluene, the contributions of ethane, butane, and ethylene were enhanced. The indirect greenhouse effects of ethane and propane, of which ozone formation potentials are the lowest and the third lowest respectively among targeted 10 NMVOCs, ranked first and fourth highest respectively. Acetaldehyde has relatively higher maximum incremental reactivity and is classified as probable human carcinogen however, its indirect GWP ranked second lowest.

온실효과에 대한 고등학교 공통과학교과서 분석 (An Analysis of High School Common Science Textbook on the Concept of Greenhouse Effect)

  • 국동식
    • 한국지구과학회지
    • /
    • 제23권6호
    • /
    • pp.455-460
    • /
    • 2002
  • 이 연구는 6차 고등학교 공통과학 교과서의 내용 중 온실효과 개념에 대한 본문진술과 제시된 그림 및 도표들을 분석하고 오개념 유발과 관련하여 문제점을 지적하고 그 개선방안을 모색하였다. 과학교과서의 개념진술이 정확하지 않아 학습자들에게 오개념을 유발하거나 재강화 할 가능성이 있는 여러 진술문을 발견하였고 학생의 과학적 개념형성에 부족한 그림이나 도표들도 발견되었다. 이들은 온실효과의 주 역할 기체와 변화, 지구온난화, 에너지원, 실험, 물리적 과정, 온실기체와 관련된 것들이다. 이들 개념진술이나 그림, 도표를 대체할 개선방안들을 제시하였다.