• 제목/요약/키워드: Green wall

검색결과 307건 처리시간 0.022초

거리협곡 벽면녹화 조성유형에 따른 미기상 변화 및 열환경 평가 (A Study on Verifying the Effect of Thermal Environment Control of Street Canyons based on Application of Green Wall System)

  • 김정호;최원준;윤용한
    • 한국환경과학회지
    • /
    • 제25권2호
    • /
    • pp.311-322
    • /
    • 2016
  • This study reduced and built Street Canyons created by skyscrapers in order to verify effect of Street Canyons by green wall within the city centre and analysed influence factors on temperature reduction according to applicative types of green wall in the lab. Applicative types were divided into three types such as non- greening type(Case A), one-side greening type(Case B), both side greening type(Case C). The result of analysis of each types showed that average temperature of Case B and Case C is respectively $1.0^{\circ}C$ and $1.7^{\circ}C$ lower than Case A. The result of analysis of WBGT was that the highest temperature was given by Case A($40.2^{\circ}C$) and second one was from Case B($39.8^{\circ}C$) and third one was from ($39.1^{\circ}C$) and in UTCI Case A records the highest temperature of $34.7^{\circ}C$ and Case B provided the second highest temperature of $33.9^{\circ}C$ and Case B gave the lowest temperature of $32.7^{\circ}C$. In PMV the highest temperature of 2.65 was from Case B and second one of 2.61 was from Case A and third one of 2.54 was from Case C. Duncan analysis of each types based on solar radiation and thermal comfort generated that there was analytical significance between Case A and Case B and Case B in terms of each types of average temperature reduction. The significance of thermal comfort in WBGT, MRT, PMV showed non-significance but, In UTCI it was analysed that there was significance between Case C and Case A.

실내 벽면녹화 공간 이용자 행태연구 - 대학구내식당 녹화 칸막이 선호를 중심으로 - (Cafeteria Users' Preference for an Indoor Green-wall in a University Dining Hall)

  • 김혜령;안동만
    • 한국조경학회지
    • /
    • 제43권6호
    • /
    • pp.62-72
    • /
    • 2015
  • 본 연구의 목적은 실내벽면녹화가 이용자에게 어떠한 측면에서 긍정적으로 인식되었으며, 이용행태에 어떠한 영향을 미치는가에 대해 알아보는 것이다. 공용공간 이용객이 벽면녹화 조성 공간을 선호한다는 실험 가설 하에 벽면녹화가 이용객의 행태에 미치는 영향에 대해 관찰실험을 진행하였다. 실내벽면녹화를 설치한 후 행태관찰결과와 설문조사를 토대로 실내벽면녹화 선호도를 분석하였다. 관찰실험은 실내벽면녹화 선호가 이용행태에 어떠한 영향을 미치는가에 관해 2014년 3월 24일부터 31일까지 총 8일간 진행하였다. 일반칸막이 공간과 벽면녹화 칸막이 공간 이용행태를 관찰카메라로 녹화하여 영상을 보면서 분석하였으며, 붐비는 시간대는 관찰시간에서 제외하였다. 좌석별 평균이용시간은 SPSS 통계프로그램을 사용하여 독립표본 T-검정을 실행하였다. 설문조사는 행태관찰 후 일반칸막이 공간과 벽면녹화 칸막이 이용객 224명에게 설문조사를 진행하였다. 설문조사로 실내벽면녹화 선호도와 그 이유에 대해 알아보고, 관찰실험, 좌석분석 결과를 종합하여 분석하였다. 벽면녹화 칸막이 공간과 일반칸막이 공간의 칸막이 인접좌석의 총 이용시간 비교결과, 실내벽면녹화 선호도가 없는 것으로 나타났다. 또한, 벽면녹화 칸막이 공간의 여성이용자 비율이 일반칸막이 공간에 비해 더 높으며, 칸막이와 식물은 좌석선택에 영향을 주지 않는 것으로 나타났다. 행태관찰에서 나타나지 않는 이용자의 심리적 측면을 파악하기 위해 설문조사를 진행하였다. 설문조사에서는 실내벽면녹화에 대한 선호도가 있는 것으로 나타났다. 일반칸막이 공간 이용객 94명 중 11.7%(11명)가 벽면녹화 칸막이 공간에 앉기를 원하였으나, '벽면녹화 칸막이 공간에 자리가 없어서' 일반칸막이 공간에 앉았다고 응답하였다. 또한 벽면녹화 칸막이 공간 이용객 130명 중 24.6%(33명)가 '실내벽면녹화를 선호해서'라고 응답하였다. 일반칸막이 공간과 벽면녹화 칸막이 이용객의 64.3%(144명)가 동일조건이라면 벽면녹화 칸막이 공간을 선택하겠다고 응답하여 선호의사가 있는 것으로 나타났으나, 행태관찰에서 선호에 차이가 없었다.

노후건축물 벽체의 열관류율 측정 및 분석 (Measurement and Analysis on Thermal Performance of Walls for Old Building)

  • 심찬형;홍구표
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.283-284
    • /
    • 2023
  • Green remodeling of pubic buildings for improving indoor environment and reducing energy consumption is increasingly promoted. The objective of this study is to measure and analyze for wall's thermal performance, thermal transmittance, of existing buildings. The method of this present study refered the ISO 9869-1 and is to measured heat flow, surface temperature of wall, and in/outdoor temperature over 7 days. And it was compared the calculated thermal transmittance with measured one. The measured wall's thermal transmittance value is about two times than the calculated thermal transmittance value.

  • PDF

Flora and newly recorded species of three colonial genera (Euteramorus, Coenocystis, and Gloeocystis) in freshwater chlorococcal green algae from Korea

  • Kim, Yong Jae
    • Journal of Ecology and Environment
    • /
    • 제37권4호
    • /
    • pp.365-378
    • /
    • 2014
  • This study was carried out on freshwater chlorococcal green algae in ponds, swamps, reservoirs, lakes and rivers (290 sites) from May 2012 to January 2014. The family Radiococaceae was identified and classified into 3 genera, 12 species and 1 variety at 23 sites. These taxa were Eutetramorus. nygaardii, E. tetraporus, E. planctonicus, E. fottii, E. globosus, E. polycoccus, Coenocystis planctonica, C. planctonica var. hercynica, C. micrococca, C. subcylindrica, Gloeocystis baneergattensis, G. papuana, and G. polydermatica. These taxa may or not had remnants of the cell wall in the colonial gelatinous envelope for a short time. Of these, 2 taxa are newly recorded in Korea from this study: 1) C. micrococca and 2) G. polydermatica.

Floristic survey and five new records of fresh-water coccoid green algae (genus Coenochloris, Radiococcus, Schizochlamydella, and Thorakochloris)

  • Kim, Yong Jae
    • Journal of Ecology and Environment
    • /
    • 제37권4호
    • /
    • pp.351-363
    • /
    • 2014
  • A study on fresh-water green coccoid algae was carried out at ponds, swamps, reservoirs, lakes and rivers (290 sites) from May 2011 to January 2014. In this study, 4 genera and 13 taxa of the family Radiococaceae having the remnants of cell wall existing for a long time in the colonial gelatinous envelope are classified and identified from 24 sites. Many taxa of this family, however, have not been recorded in Korea yet. Of these 13 taxa, 5 taxa are newly recorded in Korea by this study: 1) Schizochlamydella solitaria, 2) Thorakochloris planktonica, 3) Radiococcus bavaricus, 4) R. nimbatus, and 5) R. planktonicus.

Building Integrated Vegetation Systems into the New Sainsbury's Building Based on BIM

  • Lee, Dong-Kyu
    • 한국BIM학회 논문집
    • /
    • 제4권2호
    • /
    • pp.25-32
    • /
    • 2014
  • Today, there is a growing need of environment-friendly buildings, so-called 'green', facilities, and energy saving buildings to decrease environmental pollutants released into cities by construction activities. Green-Building Information Modeling (Green-BIM) is a purpose-built solution which supports to forecast energy consumption of 3-D model of a building by augmenting its primary 3-D measurements (width, height and depth) with many more dimensions (e.g. time, costs, social impacts and environmental consequences) throughout a series of sequential phases in the lifecycle of a building. The current study was carried out in order to integrate vegetation systems (particularly green roof and green wall systems) and investigate thermal performance of the new Sainsbury's building which will be built on Melton road, Leicester, United Kingdom. Within this scope, a 3-D building model of the news Sainsbury's building was first developed in $Autodesk^{(R)}$ $Revit^{(R)}$ and this model was then simulated in $Autodesk^{(R)}$ $Ecotect^{(R)}$once weather data of the construction site was obtained from $Autodesk^{(R)}$ Green Building $Studio^{(R)}$. This study primarily analyzed data from (1) solar radiation, (2) heat gains and losses, and (3) heating and cooling loads simulation to evaluate thermal performance of the building integrated with vegetation system or conventionally available envelops. The results showed that building integrated vegetation system can potentially reduce internal solar gains on the building rooftops by creating a 'bioshade'. Heat gains and losses through roofs and walls were markedly diminished by offering greater insulation on the building. Annual energy loads for heating and cooling were significantly reduced by vegetation more significantly through the green roof system in comparison to green wall system.

종합병원의 친환경적 시설 실태와 향후 과제 (Present and Future of Green Hospitals in Korea)

  • 서영준;강신희;김연희;이용균
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제16권1호
    • /
    • pp.43-53
    • /
    • 2010
  • This study purports to investigate the status quo of the environmentally-friendly green healthcare in teaching hospitals through the questionnaire survey. Data were collected from a total of 46 hospitals. The survey results revealed that most teaching hospitals did not meet the global standard of environmentally-friendly green hospitals. Especially, such items as alternative energy system, water recycling, CO2 emission reduction, green building construction, installation of pond or spring were found to be significantly below global standard. Based upon the study results, various strategies for establishing green hospitals were discussed. For example, energy saving design, such as solar heating, natural wind cooling, automatic temperature controller, green material use, wall surrounded by ivy, were recommended. In conclusion, the strategy and evaluation tool developed in the study will provide a good guide for establishing environmentally-friendly green hospitals.

Fabrication of Uniform Hollow Silica Nanospheres using a Cationic Polystyrene Core

  • Yun, Dong-Shin;Jang, Ho-Gyeom;Yoo, Jung-Whan
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권5호
    • /
    • pp.1534-1538
    • /
    • 2011
  • Uniform, hollow nanosilica spheres were prepared by the chemical coating of cationic polystyrene (cPS) with tetraethylorthosilicate (TEOS), followed by calcination at 600 $^{\circ}C$ under air. cPS was synthesized by surfactant-free emulsion polymerization using 2,2'-azobis (2-methyl propionamidine) dihydrochloride as the cationic initiator, and poly(vinyl pyrrolidone) as a stabilizer. The resulting cPS spheres were 280 nm in diameter, and showed monodispersion. After coating, the hollow silica product was spherically shaped, and 330 nm in diameter, with a narrow distribution of sizes. Dispersion was uniform. Wall thickness was 25 nm, and surface area was 96.4 $m^2/g$, as determined by BET. The uniformity of the wall thickness was strongly dependent upon the cPS surface charge. The effects of TEOS and ammonia concentrations on shape, size, wall thickness, and surface roughness of hollow $SiO_2$ spheres were investigated. We observed that the wall thicknesses of hollow $SiO_2$ spheres increased and that silica size was simultaneously enhanced with increases in TEOS concentrations. When ammonia concentrations were increased, the irregularity of rough surfaces and aggregation of spherical particles were more severe because higher concentrations of ammonia result in faster hydrolysis and condensation of TEOS. These changes caused the silica to grow faster, resulting in hollow $SiO_2$ spheres with irregular, rough surfaces.

농가주택 법면 보호공을 위한 환경친화블럭의 적용성 평가 (Application of Environmentally friendly block for the slope stability and protection of Rural Housing)

  • 신방웅;오세욱;권영철;조천희;한현구
    • 한국농촌건축학회논문집
    • /
    • 제2권1호
    • /
    • pp.101-112
    • /
    • 2000
  • Green environment is most important factor to human being taking a side view of psychological aspect. But, as the civilization progresses rapidly, the green environment decreases. At present, various environmentally friendly methods are developed to prevent the ill effect of the concretes. n this study, Ecostone retaining wall method, which is a kind of environmentally friendly block, are used for verifying the application to the slope stability and protection of rural hosing. In case of rural hosing and structure, the height of the slope is not high and additional loading doesn't act on the slope except the gravity loading of housing and structure. From the result of the stability analysis of Ecostone, 3m to 7m Ecostone retaining wall can have an equivalence capacity comparing with the concrete retaining wall. Therefore, Ecostone method can apply to retaining wall with the structural safety and environmentally friendly aspect using the plants and vegetation.

  • PDF