• Title/Summary/Keyword: Green Space System

Search Result 316, Processing Time 0.025 seconds

A Study on the Method and Planning Characteristics of Environment-friendly Skyscraper - Focused on the Analysis of Environment-friendly Skyscraper in other countries - (친환경 초고층 건축 계획 특성 및 기법에 관한 연구 - 해외 친환경 초고층 건축 분석을 중심으로 -)

  • Kim, Ja Kyung
    • KIEAE Journal
    • /
    • v.8 no.3
    • /
    • pp.27-36
    • /
    • 2008
  • Urban architecture density is getting higher, and this trend is expected to continue in the future. Therefore, skyscrapers are being brought into relief as future alternative architecture beyond symbolic meaning in the aspect of demand and supply of urban space. However, skyscrapers which were newly built have many problems such as consumption of enormous amounts of energy, destruction of natural environment, and traffic jam. For this reason, environment-friendly skyscrapers based on the concept such as Green Building and Green Skyscraper started to be built around the world. However, plans or evaluation standards, which take account of the environment-friendly aspect of skyscrapers, leave much to be desired. And especially it is hard to find environment-friendly skyscrapers. Therefore, this study aims to establish the concept of environment-friendly skyscrapers that has not properly been defined, and to find realistic planning methods and practical alternatives through the analysis of the works that have brilliant ideas about environment-friendly architectural method. From the perspective of architectural planning, we did case analysis focused on site planning, form planning, elevation and floor planning, and tried to give useful ideas for high-rise architectural planning in Korea by finding practical solution focused on the active use of natural energy, saving resources, the reduction of wastes, natural architectural environment design and natural friendly system from the view of environment-friendly technological analysis.

Next Generation Rotorcraft Technologies in USA and Europe (미국과 유럽의 차세대 회전익 기술 개발 현황)

  • Oh, Sejong;Kim, Sung Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.8
    • /
    • pp.713-721
    • /
    • 2014
  • In Europe and USA, new programs called GRC(Green Rotorcraft) and SRW (Subsonic Rotary Wing program) respectively, have been currently underway for developing the next generation rotorcraft. The final goal is to develope fuel-efficient/environmental-friendly tilt-rotor civilian rotorcraft, which can partly replace short-range regional aircrafts. Also for safe operation, the new rotorcraft technology is cooperated with the new air transport management(ATM) system, called SESAR(Single European Sky ATM Research) and NextGen(Next Generation Air Transport System) in Europe and USA. In addition to achieve the final goal, the tilt-rotor aircraft, they are trying to improve the performance of conventional helicopters by adopting more efficient propulsion system, active rotor system, and reducing internal and external noise. Especially in GRC program of Europe, the environmental factors such as noise, fuel efficiency, reduction of emission gas(CO2, NOx), are focused for the new technologies.

Thermal Performance Analysis of Hybrid heat Supply System for Zero Carbon Green Home (제로카본 그린홈 구현을 위한 하이브리드 열공급 시스템의 열성능 분석)

  • Joo, Hong-Jin;Lee, Kyoung-Ho;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.53-59
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000kcal/hr, a $0.15m^3$ hot water storage tank for space heating, a evacuated tubular solar collector $3.74m^2$ of aperture area at the $20^{\circ}$ install angle, a $0.3m^3$ hot water storage tank. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.

Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy (태양열 시설원예 난방시스템 장기실증 성능분석 연구)

  • Lee Sang-Nam;Kang Yong-Heack;Yu Chang-Kyun;Kim Jin-Soo
    • New & Renewable Energy
    • /
    • v.1 no.2 s.2
    • /
    • pp.53-59
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a green-house culture facility for reducing healing cost, Increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex In Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely Investigated by changing the control condition based on the temperature difference which Is the most important operating parameter For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, It is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

Low Carbon and Green Growth Cave Lightings with SOLAR-LED System (SOLAR-LED 시스템과 저탄소녹색동굴조명)

  • Soh, Dea-Wha;Kang, Sang-Tack;Soh, Hyun-Jun
    • Journal of the Speleological Society of Korea
    • /
    • no.95
    • /
    • pp.15-21
    • /
    • 2009
  • Global village warming and carbon dioxide CO2 gas, and the human efforts for their healing and necessary alternative technology would be much more difficult things than that of making necessary funds and efforts to lay to sleep angry nature on the earth. The limited natural resources of fossil fuel would be dried up in several decades, and the intensity of diplomatic negotiations for natural resource guarantee among countries may be showed looking alike an war. The drain of fossil fuel called a new word of alternative policy like an environment-friendly green-growth, and the solar-cell and lighting technology for the solar energy applications were developed still more repeatedly day by day from oil lantern to LED high-tech illumination in great economy. Therefore, it was studied that the low-carbon green-growth illumination technology in cave applications with SOLAR-LED system which was produced and unified in connection with solar-cell and LED from the semiconductor production technology, and it was also clarified in necessary with useful cave lighting in heatless and with no photosynthesis of plant production in underground space.

The Color Variability Monitoring of HBC722

  • Baek, Giseon;Pak, Soojong;Green, Joel D.;Kang, Wonseok;Jeon, Yiseul;Choi, Changsu;Lee, Jeong-Eun;Im, Myungshin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.103.1-103.1
    • /
    • 2012
  • We present the results of SDSS r, i and z band photometry for HBC722 (also known as $LkH{\alpha}$ 188 G4, PTF10qpf and V2493 Cyg), with Camera for Quasars in Early uNiverse (CQUEAN) attached to 2.1m Otto Struve telescope at McDonald Observatory, USA. HBC722 is a newly erupted FU Orionis type object, which produced optical outburst (${\Delta}V$=4.7 mag) over a year that peaked in 2010 September. We carried out the monitoring observations during 48 nights from 2011 April to 2012 June to check the short-term and the long-term variabilities for chasing the Keplerian rotation of the system. Comparing the photometric results of r, i and z band, we describe the color variability which is related to the physical properties of the system like circumstellar disk and accretion process.

  • PDF

Appilication of a Green City Index as a Green Space Planning Index for the Low-Carbon Green City of Gangneung-si

  • Cho, Su-Hyun;Jo, Hyun-Ju
    • Journal of Environmental Science International
    • /
    • v.25 no.10
    • /
    • pp.1381-1387
    • /
    • 2016
  • This study aims to establish baseline data for sustainable monitoring by applying the green city index (GCI), which is set up to evaluate the city level, to the city of Gangneung-si, which was designated as a pilot city for the Low-carbon Green Growth City project by the Ministry of Land, Infrastructure, and Transportation. The GCI was applied in the framework of European systems, while considering the social and economic status of Korea. Indicators from 7 areas-$CO_2$, energy, building, transportation, water, waste, and quality of atmosphere were analyzed, except for qualitative indicators. Results indicate that total $CO_2$ emissions were 30.8 tons per capita, or 2.2 tons per one million units of real GDP. The total final energy consumption was 0.231 TOE/capita, or 0.317 TOE per one million units of real GDP. The percentage of total energy derived from renewable resources was 0.41% and energy consumption by the building was $433.5Mwh/1,000m^2$. The total percentage of the working population travelling to work daily by public transportation (limited to bus) was 19%. Further, the total annual water consumption was $99m^3/capita$, and the water lost in the water distribution system was $0.057m^3/capita/day$. The total annual waste collected was 0.0077 ton per capita, The annual mean emission were 0.014 ppm/day for $NO_2$, 0.005 ppm/day for $SO_2$, and 0.019 ppm/day for $O_3$. The annual mean for PM10 emissions was $39{\mu}g/m^3/day$.

A Study on Window Type Ventilation System Using IT Technology for Energy Saving in Housing Space (주거공간 내 IT기술 적용 에너지 저감 창호형 환기시스템 연구)

  • Lee, Eun-Hye;Kim, Yong-Seong;Ji, Chung-Gu
    • Journal of the Korean housing association
    • /
    • v.24 no.2
    • /
    • pp.61-68
    • /
    • 2013
  • This study has the purpose to adapt IT technology on Window Type Ventilation System for the energy saving and providing of user-centered comfortable environment. This is Derived a look at the case of the window type ventilation system and researched its IT technology for reducing energy applied to the Green Home. This indicates a solution for the established Window Type Ventilation System which can not be satisfied with user's requirement by proposing Window Type Ventilation System applied to IT technology that makes it control the intelligent, combined indoor environment system and providing information. Also, it shows energy saving efficiency of Window Type Ventilation System applied to IT technology based on the model study, analysing the performance of air-conditioning and ventilation energy saving through the experiment to compare with the established Window Type Ventilation System. The result of this study has the significance that it suggests an alternative for energy saving of housing space.

A Study on the Dwellers' Awareness and Demand for the Pro-Environmental Elements of Interior Space of Apartment House - With homemakers with children attending elementary.middle.high schools and college - (아파트 실내공간의 친환경적 요소에 대한 거주자 인식 및 요구 - 광주광역시 초.중.고.대학생자녀를 둔 주부를 대상으로 -)

  • Yang, Hyeong-Sun;Kim, Mi-Hee
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.11a
    • /
    • pp.183-186
    • /
    • 2007
  • In modern society, sense of crisis from environmental destruction caused by rapid industrial development, economic growth and improvement of educational level and medicine made environmental preservation and comfortable residential environment a necessary and sufficient condition. Since government conducted 'green building rating system' from 2002, application of pro-environmental elements has been extended. But the concept of substantial pro-environmental housing remains the stage of complex planning yet and application of system to interior space which has the most direct influence on actual dwellers is very poor.

  • PDF

A Study on Parking Reality in Residential Areas and an Improvement Plan -Focusing on concentrated areas of multi-family housings in Gongneung-dong, Seoul-

  • Hwang, Sung Eun;Kang, Boo Seong
    • Architectural research
    • /
    • v.20 no.4
    • /
    • pp.103-108
    • /
    • 2018
  • Wandering behavior is a serious problem among the elderly in nursing homes, yet it has received relatively little study As multi-family houses built before the '80s in South Korea were designed, it did not take account into issues related to parking so that at present parking became a big issue. The Seoul Metropolitan Government tried various ways to sort out the parking problem in multi-family house areas, but inadequate parking and illegal parking are still an ongoing problem. Thus, the purpose of this study was to examine current situation on resident parking only and illegal parking centered on a congested area of multi-family houses in Seoul and present the improvement plan of parking problems through case investigation home and abroad. As the result of the survey, it has been identified that the subject area consists of 506 households in total and 186 parking spaces and also, 100 cars in parking space or parking lot in housing space and 143 in illegal parking. Green parking business and open access parking system were suggested as solution plan for parking problem. Thus, it is expected that through green parking business for 6 houses and the parking lot of elementary schools around, the illegal parking problem would be sorted out.