• Title/Summary/Keyword: Green Building Technology

Search Result 316, Processing Time 0.031 seconds

Experimental Study of Cooling Energy Saving Verification Using Blinds and Phase Change Material(PCM) (창호 블라인드와 상변화물질 적용에 의한 냉방 에너지 사용량 절감효과에 대한 검토 연구)

  • Song, Young-Hak;Kim, Ki-Tae;Koo, Bo-Kyung;Lee, Keon-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.1
    • /
    • pp.26-31
    • /
    • 2014
  • This study looks into changing building energy use by application of phase change material (PCM). PCM does not need extra energy for operation and is used for reducing building energy use and, CO2 output by displaying semi-permanent effects after installation. It also is able to avoid the maximum electric power time-zone by inducing a time lag phenomenon of cooling and heating loads with high thermal capacity using latent heat. To verify the efficiency of blinds and PCM, tests about the PCM operation mechanism using air conditioning machinery and nocturnal panel cooling were done. In the test results of the case using PCM installation, a $45^{\circ}$ blind angle with machinery air conditioning and nocturnal panel cooling at the same time shows a 22 percent energy saving effect against general space. The test results of each case were compared and analyzed based on the blind and window opening settings. Finally, the energy reduction of existing buildings using PCM application was reviewed based on the final measurement results.

An Experimental Study of the Dried and Unified Execution Technology for the Sub-Organization of the Green Roofs System using the Panel of Block Type (블록형 패널을 이용한 옥상녹화 하부시스템의 건식화 $\cdot$ 일체화 시공기술에 대한 실험적 연구)

  • Moon, You-Seok;Jang, Sang-Muk;Hong, chae-ho;Cha, Yun-Jung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.119-123
    • /
    • 2007
  • Recently, the green roofs market is active, but most constructors use former waterproofing method. So there are a lot of problems in the sub-organization of the green roofs system. I studied to use the block panel for the sub-organization of the green roofs system and I tested about the effectiveness of waterproofing, root barrier, drainage, and insulation. I have not found any problems about waterproofing, root barrier, drainage, and insulation in the results. The sub-organization of the green roofs system using the block panel is effective for waterproofing, root barrier, drainage, and insulation. We can apply it to the dried and unified execution technology.

  • PDF

Measuring the Potential of the Korean Border Area for Green Détente Practice using Prosuming-index (프로슈밍지표를 통한 접경지역 기반 남북한 그린데탕트 실천 잠재력 분석)

  • Ahn, Jin-Hee;Koh, Kyung-Taek;Kim, YoungSeok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.5
    • /
    • pp.675-687
    • /
    • 2023
  • The border area between the South and North Korea is considered a stage for promoting Green Détent through the transformation of the Demilitarized Zone into the Green Peace Zone. This paper proposes 'Prosuming-index' composed of items to evaluate the multi-layered nature of industrial and infrastructure projects in the ecological and environmental fields planned in the border area. Based on the prosuming-index, we derived the following four types of potential for Green Detent practice in the border area-first, the Incheon and Ganghwa regions as 'a logistics/human network and agricultural/fishery production area', second, the northern Gyeonggi region as a 'cooperative network area based on the smart technology industries', third, the western Gangwon and the parts of nothern Gyeonggi region, as 'a multiple prosumer's area based on carbon neutral technologies', lastly, the eastern Gangwon region, as 'a transition area from idle or aged infrastructure to green infrastructure through the renewable energy industries'.

Analysis of Scoring Status and Adoption Characteristics by Evaluation Items based on LEED Canada Certified Cases (LEED Canada 인증건축물의 평가항목별 득점현황과 적용특성 분석)

  • Choi, Dong-Ho
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.655-668
    • /
    • 2018
  • This paper analyzes the applicability and technology level of the green building element technology by analyzing the scorecard of the LEED Canada certified buildings. The results of this analysis will be able to evaluate the current status and level of application of green building element technology, and it will be used as a basic data to prepare for the revision of the certification standards and the establishment of strategies for the future green building activation. In this study, 1,010 LEED Canada certified buildings from 2011 to 2016 were analyzed. The results were analyzed by focusing on the status of greening by certification category and the characteristics of adoption by sub-category. The results of the study are summarized as follows. (1) EA category showed the biggest difference between the certification scores and the adoption rates than other categories, and it was confirmed that it is not easy category from the viewpoint of practical adoption. On the other hand, the ID (Innovation & Design Process) and WE were analyzed to be relatively easy to apply, with a score of over 72%. (2) In the case of Platinum class, the upper adoption rate is shown in all categories except MR. The Gold class shows the adoption rate of WE and ID in the top, and the middle rate in most categories. Silver grades showed lower rates in the three categories except WE, ID and EQ. Certified grades showed the adoption rates of the bottom except the two categories.

Prediction of Effect on Outside Thermal Environment of Building and Green Space Arrangement by Computational Fluid Dynamic (CFD 시뮬레이션을 이용한 건축물 및 녹지배치가 외부 열환경에 미치는 영향 예측)

  • Kim, Jeong-Ho;Son, Won-Duk;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.21 no.1
    • /
    • pp.69-81
    • /
    • 2012
  • This study forecasts changes in thermal environment and microclimate change per new building construction and assignment of green space in urban area using Computational Fluid Dynamics(CFD) simulation. The analysis studies temperature, humidity and wind speed changes in 4 different given conditions that each reflects; 1) new building construction; 2) no new building construction; 3) green spaces; and 4) no green spaces. Daily average wind speed change is studied to be; Case 2(2.3 m/s) > Case 3. The result of daily average temperate change are; Case 3($26.5^{\circ}C$) > Case 4($24.6^{\circ}C$) > Case 2($23.9^{\circ}C$). This result depicts average of $2.5^{\circ}C$ temperature rise post new building construction, and decrease of approximately $1.8^{\circ}C$ when green space is provided. Daily average absolute humidity change is analysed to be; Case 3(15.8 g/kg') > Case 4(14.1 g/kg') > Case 2(13.5 g/kg'). This also reveals that when no green spaces is provided, 2.3 g/kg' of humidity change occurs, and when green space is provided, 0.6 g/kg change occurnd 4(1.8 m/s), which leads to a conclusion that daily average wind velocity is reduced by 0.5 m/s per new building construction in a building complex.

A Study on Green Building Certification Criteria of Educational Facilities based on LEED Certified Cases (LEED 인증사례 분석을 통한 교육시설의 녹색건축 인증기준에 관한 연구)

  • Ahn, Dong-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.122-132
    • /
    • 2014
  • Sustainability became the keyword of our society worldwide, and it is undoubtful that buildings are mainly responsible for green house gas emission and energy consumption. Among different project types, educational facility was selected in this study to find out what needs to be addressed in order to provide students better learning environments. Scorecards from 32 LEED certified school projects went through analysis and essential components as design strategies in sustainable educational facilities were extracted based on application rate of each credit in LEED for School(2009). The extracted data were further analyzed in comparison with related components in G-SEED. The results would be used as guidelines for those of who design sustainable education facilities and prepare green building certifications. and it would further foster architect's responsibility towards green society in Korea.

A Study on User's awareness for Workable Environment Improvement of Public Building by Green Building Renovation - Focus on the 1st & 2nd Buildings of Jeju Special self-Governing Province - (그린빌딩화를 통한 청사 업무환경 개선을 위한 사용자 의식에 관한 연구 - 제주특별자치도 제 1, 2청사를 중심으로 -)

  • Oh, Chang-Hun;Kim, Tae-Il;Yang, Gun
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.3
    • /
    • pp.162-171
    • /
    • 2010
  • In the field of architecture, the sustainable architectural concept, "green buildings," has been suggested as an alternative to solve the environmental problems; however, the concept has not yet been converted to awareness and development of related technology. The leading role of public sector has been socially and economically influential in the nation, hence green public buildings are significant to stimulate the spread of green buildings in the nation. This study is to draw an appropriate method of implementing the green building concept to the two main government office buildings of Jeju Special Self-Governing Province based on the plan to improve the work environment; it is also to provide long-term directions of implementing policies and reference for the public and private sector to utilize the green building concept. Its research methodology was the survey method. A total of 142 questionnaires were returned by government employees of the two buildings. It accounts for 20% of the total number of 711 workers of the buildings. According to the analysis of the returned questionnaire, the majority of the surveyed have a positive evaluurned toward the introduction of green buildings due to their expecturned for the possible i the buildingstheir work environment. In addition, they showed more interest in space planning with natural ventilation than automatic systems regarding applied methods for green buildings.

Research on the well-being-centric green building certification - Focused on AHP Analysis of Expert Survey in order to introduce well-being criteria - (웰빙 중심 친환경 건축인증을 위한 연구 - 웰빙항목 도입을 위한 전문가 AHP 분석을 중심으로 -)

  • Nam, Hye-Ryeong;Lee, Byung-Yun
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.29-38
    • /
    • 2016
  • Purpose: This study is conducted to contribute to the improvement of Green Standard for Energy and Environmental Design(G-SEED) from the existing energy physical efficiency-centric system to the well-being-centric green building certification system. Method: In order to modify existing G-SEED Certification, three phases of research have been conducted; 1) identification of needs of well-being-centric environment-friendly construction certification system, 2) comparison of domestic certification system with WELL Building standard(WELL) which focuses on human health and promotion of wellness and 3) AHP analysis to sort out the supplement items from WELL. Result: We proposed four alternatives which should be preferentially introduced to the existing domestic certification system; addition of independent 'well-being' section(field) in G-SEED, insertion of 'well-being' indicators in each relevant section of G-SEED, addition of 'well-being' indicators in 'Innovative Design(ID)' of G-SEED and independent score systems for 25 items in a high priority.

Research on Health Performance Evaluation of Existing Buildings using WELL Building Standard - for Green Remodeling applied Buildings - (웰 빌딩 스탠다드를 활용한 기존 건축물의 건강성능평가 연구 - 그린리모델링 적용 건축물을 대상으로 -)

  • Lee, Du Hwan;Kim, Young Il;Kim, Jae Moon
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.2
    • /
    • pp.165-173
    • /
    • 2020
  • The purpose of this research is to evaluate the health performance of existing buildings which completed green remodeling using the WELL Building Standard developed by Delos in the USA. The features and the level of improvement in health were examined and the results were as follows. As a result of comprehensive evaluation of the health performance of the target building, the health performance after green remodeling improvement was improved by 17.3% compared to before green remodeling. As a result of applying the alternatives for improving health performance, improvements were 22.9% by Alternative 1, 28.8% by Alternative 2, and 28.7% by Alternative 3. If the improvement ratio with respect to the construction cost were compared, Alternative 1 was the best followed by Alternative 2. Finally, the cost effectiveness of improving health performance against construction cost were best in the order of self-closing door installation, airtight seal, and pest inspections.

A Case Study of Extensive Green Roof System for Tropical Climate in Malaysia

  • Kok, Kah Hoong;Jung, Kwansue;Sidek, Lariyah Mohd;Abidin, Mohd Roseli Zainal;Felix, Micah Lourdes
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.329-329
    • /
    • 2016
  • Rapid urbanization has taken environmental toll on the surrounding which can be witnessed by the advent of global warming and climate change. Driven by environmental needs, Green Building Index (GBI) was established in Malaysia to drive initiative to lead the property industry towards becoming more environmental friendly. Green roofs (roof with vegetated cover) as one of the assessment criteria of GBI, are gaining attention in the Malaysian society as a versatile new environmental friendly mitigation technology. This paper evaluates the qualitative and quantitative performances of an extensive green roof at Humid Tropics Centre under local tropical climate. Simulations showed that the extensive green roof system could reduce the peak discharge up to 26% in relation to impervious brown roof. Its reduction ability decreased for storms with intense rainfall. Increment of pH was observed for the green roof runoff and the runoff water quality ranged between class I and II under Water Quality Index (WQI). High concentrations of phosphate were noticed in the runoff samples and substrates (fertilized planting soil) might be the potential contributor. Findings indicate that there was a reduction of around $1.5^{\circ}C$ for indoor temperature of the building after installation of the extensive green roof.

  • PDF