• 제목/요약/키워드: Gravity-based foundation

검색결과 27건 처리시간 0.029초

Vibration characteristics of caisson breakwater for various waves, sea levels, and foundations

  • Lee, So-Young;Huynh, Thanh-Canh;Dang, Ngoc-Loi;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • 제24권4호
    • /
    • pp.525-539
    • /
    • 2019
  • In this study, vibration characteristics of a gravity-based caisson-foundation breakwater system are investigated for ambient and geometric parameters such as various waves, sea levels, and foundation conditions. To achieve the objective, following approaches are implemented. Firstly, operational modal analysis methods are selected to identify vibration modes from output-only dynamic responses. Secondly, a finite element model of an existing caisson-foundation breakwater system is established by using a structural analysis program, ANSYS. Thirdly, forced vibration analyses are performed on the caisson-foundation system for two types of external forces such as controlled impacts and wave-induced dynamic pressures. For the ideal impact, the wave force is converted to a triangular impulse function. For the wave flow, the wave pressure acting on the system is obtained from wave field analysis. Fourthly, vibration modes of the caisson-foundation system are identified from the forced vibration responses by combined use of the operational modal analysis methods. Finally, vibration characteristics of the caisson-foundation system are investigated under various waves, sea levels, and foundations. Relative effects of foundation conditions on vibration characteristics are distinguished from that induced by waves and sea levels.

성능검증을 위한 마이크로파일 현장 시험시공 및 재하시험 (Verification Studies for Field Peformance of Micropiling)

  • 구정민;이기환;조영준;최창호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.368-375
    • /
    • 2009
  • This paper describes field installation and load test results performed for three types of micropiles in the process of developing a new micropiling method. Field tests were performed for two conventional types(i.e., micropile reinforced with steel bar and gravity grouting, micropile reinforced with steel bar and steel casing and gravity grouting) and a proposed type(i.e., micropile reinforced with hollow steel pipe wrapped with geotextile-pack and pressurized grouting). The load test results subjected to axial compression and tension and lateral loading conditions are described in this paper. The micropiles were exposed in the air in order to verify the installation quality and curing condition of grouting material via ground excavation. Axial compression and tension test results indicate that the new micropile type provide at least 40% higher bearing capacity than that of conventional types. Based on the examination of exposed piles, it is induced that the proposed method, packed micropile, provides better interlocking between grouts and surrounding soils and increases higher frictional resistance comparing to conventional types.

  • PDF

Seismic effects of epicenter distance of earthquake on 3D damage performance of CG dams

  • Karalar, Memduh;Cavusli, Murat
    • Earthquakes and Structures
    • /
    • 제18권2호
    • /
    • pp.201-213
    • /
    • 2020
  • Seismic damages that occurred by the effects of epicenter distance of the earthquake are one of the most important problems for the earthquake engineering. In this study, it is aimed to examine the nonlinear seismic behaviors of concrete gravity (CG) dams considering various epicenter distances. For this purpose, Boyabat CG dam that is one of the biggest concrete gravity dams in Turkey is selected as a numerical application. FLAC3D software based on finite difference method is used for modelling and analyzing of the dam. Drucker-Prager nonlinear material model is used for the concrete body and Mohr-Coulomb nonlinear material model is taken into account for the foundation. Special interface elements are used between dam body and foundation to represent interaction condition. Free-field and quiet non-reflecting boundary conditions are utilized for the main surfaces of 3D model. Total 5 various epicenter distances of 1989 Loma Prieta earthquake are considered in 3D earthquake analyses and these distances are 5 km, 11 km, 24 km, 85 km and 93 km, respectively. According to 3D seismic results, x-y-z displacements, principal stresses and shear strain failures of the dam are evaluated in detail. It is clearly seen from this study that the nonlinear seismic behaviors of the CG dams change depending to epicenter distance of the earthquake. Thus, it is clearly recommended in this study that when a CG dam is modelled or analyzed, distance of the earthquake fault to the dam should be strongly examined in detail. Otherwise, earthquake damages can be occurred in the concrete dam body by the effects of seismic loads.

수치해석을 통한 해상풍력 말뚝지지중력식기초의 수평거동 분석 (Numerical Study on Lateral Pile Behaviors of Piled Gravity Base Foundations for Offshore Wind Turbine)

  • 서지훈;추연욱;구정민;김영호;박재현
    • 한국지반공학회논문집
    • /
    • 제32권11호
    • /
    • pp.5-19
    • /
    • 2016
  • 본 연구에서는 해상풍력타워를 지지하는 말뚝지지중력식기초에 대한 수평거동을 분석하기 위하여 3차원 수치해석을 수행하였다. 말뚝지지중력식기초는 연약한 점토지반에 취약한 중력식기초를 보완하기 위하여 개발되었으며, 다섯본의 말뚝이 십자배열로 설치되어 수직지지력을 확보한다. 수치해석은 다음 네 가지 케이스를 모델링하여 비교하였다. 이는 a) 단말뚝 b) $3{\times}3$무리말뚝 c) 십자배열무리말뚝 d) 말뚝지지중력식기초이다. 모든 케이스는 비배수전단강도 20kPa의 단일 점토층을 모사하였으며, 수치해석결과로부터 네 가지 케이스에 대한 p-y곡선과 P-승수를 산정하였다. 말뚝 수가 증가함에 따라 무리말뚝효과가 증가하였다. 말뚝지지중력식기초의 경우, P-승수가 무리말뚝과 상이한 경향을 보였다. 응력분포를 통해 거동의 차이를 비교하였고 말뚝지지중력식기초의 수평거동은 지표면과 매트 사이의 상호 작용이 상당한 영향을 미치는 것으로 나타났다.

내부 유체 슬로싱 효과를 고려한 부유이송 해상풍력 기초의 동적 안정성 해석 (Dynamic Stability Analysis of Floating Transport Wind-Turbine Foundation Considering Internal Fluid Sloshing Effect)

  • 홍석진;김동현;강신욱;강금석
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권3호
    • /
    • pp.461-467
    • /
    • 2016
  • 부유 이송식 해상풍력 기초를 목표 지점에 설치하기 위해서는 내부의 중공부에 해수를 주입하여 착저 시키게 되는데, 그 과정에서 중량 및 무게 중심과 부력중심이 변하게 되어 부유식 기초가 불안정해 질 수 있다. 부유 이송식 기초의 동적안정성 해석은 기초 외부의 수력학적 하중과 6-자유도 운동을 하게 되는 기초에 작용하는 파도와 조류 하중 및 설치 과정에서 기초 내부의 중공부로 투입되는 해수의 무게중심 이동까지 동시에 고려해야 하는 복잡한 문제이다. 따라서 본 연구에서는 3차원 비정상 CFD 기법과 다물체 동역학 기법을 연성 (coupling)한 정밀 해석기법을 적용하여 부유 이송식 기초 내부 물의 슬로싱 운동까지 고려한 동적안정성 해석을 수행하고 특성을 분석하였다.

Key Technologies for Super Tall Building Construction: Lotte World Tower

  • Kim, Gyu Dong;Lee, Joo Ho
    • 국제초고층학회논문집
    • /
    • 제5권3호
    • /
    • pp.205-211
    • /
    • 2016
  • This paper addresses the key technologies for supertall building construction based on the Lotte World Tower project in Korea. First, the mega-mat foundation construction technologies are shown, including ultra-low heat concrete, heat of hydration control programs, and the logistics plan. Then, high strength concrete technologies of 50~80 MPa are introduced and discussed within the context of the highest pumping record in Korea at 514.25 meters. Structural design concepts of gravity load and lateral force resistance systems are introduced, along with surveying systems using GNSS and temporary installation plans of special heavy equipment like tower cranes, hoists, and high pressure concrete pumps. If it is possible to coordinate these key technologies and others, optimizing for the building's design and construction, supertall building construction can be successfully completed.

안벽기초 구조물의 신뢰성설계를 위한 목표파괴확률 결정 (Target Probability of Failure of Quay Wall Foundation for Reliability-Based Design)

  • 윤길림;윤여원;김홍연
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.379-389
    • /
    • 2010
  • It is very important to determine a target probability of failure in reliability based design such as an allowable factor of safety in working stress design because they are indices to judge the stability of structures. We have carried out reliability analyses of nationwide gravity type quay walls and found that sliding and foundation failures of quay walls were dominant failure modes for every case of loads. And a target probability of failure for bearing capacity of foundation of quay wall was also determined in this study. Of several approaches which have been suggested until now, a couple of reasonable approaches were used. Firstly, in order to consider the safety margin of structures which have been executed so far, the reliability levels of existing structures were assessed. And then a mean probability of failure for the quay walls was estimated. In addition, life cycle cost(LCC) analyses for representative structures were performed. Probabilities of failure for several quay walls were calculated with changing the width of each quay wall section. LCC of quay wall which is requiring case by case during the service life was evaluated, and also the optimum probability of failure of quay wall which minimizes LCC was found. Finally, reasonable target probabilities of failure were suggested by comparing with mean probability of failure of existing structures.

  • PDF

해상풍력타워 석션기초의 설치시 거동에 대한 모형 시험 연구 (Installation of Suction Caisson Foundation for Offshore Wind Turbine : Model Test)

  • 김동준;김수린;추연욱;김동수;이만수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.825-839
    • /
    • 2010
  • The global and domestic market for offshore wind farm is expected to grow fast, and the design and installation of substructure and foundation is getting more important. As for the offshore wind farms located in the shallow(depth < 20m) water, the construction and installation of the substructure and foundation makes up about 1/4 ~1/3 of the offshore wind farm construction cost, and the portion is expected to increase because the turbine capacity is increasing from 2 ~ 3MW to 5MW or larger and the water depth of wind farms is also increasing over 30m. As a foundation for offshore wind turbine, the suction caisson foundation is being considered to be a highly competitive alternative to the conventional monopile or gravity based structure, because it has features suitable for the offshore construction such as quick installation, no heavy equipment for penetration and no hammering noise for driving. In order to study the installation behaviour of the suction caisson, laboratory tests were performed with sand. The pore water pressure and displacement were measured to analyze the suction pressure during penetration, the penetration speed and the amount of heaving.

  • PDF

Seismic fragility analysis of a cemented Sand-gravel dam considering two failure modes

  • Mahmoodi, Khadije;Noorzad, Ali;Mahboubi, Ahmad
    • Computers and Concrete
    • /
    • 제26권6호
    • /
    • pp.483-495
    • /
    • 2020
  • Dams are vital infrastructures that are expected to maintain their stability during seismic excitations. Accordingly, cemented material dams are an emerging type, which are being increasingly used around the world owing to benefiting from advantages of both earth-fill and concrete gravity dams, which should be designed safely when subjected to strong ground motion. In the present paper, the seismic performance of a cemented sand and gravel (CSG) dam is assessed using incremental dynamic analysis (IDA) method by accounting for two failure modes of tension cracking and base joint sliding considering the dam-reservoir-foundation interactions. To take the seismic uncertainties into account, the dam is analyzed under a suite of ground motion records and then, the effect of friction angle for base sliding as well as deformability of the foundation are investigated on the response of dam. To carry out the analyses, the Cindere dam in Turkey is selected as a case study, and various limit states corresponding to seismic performance levels of the dam are determined aiming to estimate the seismic fragilities. Based on the results, sliding of the Cindere dam could be serious under the maximum credible earthquake (MCE). Besides, dam faces are mostly to be cracked under such level of intensity. Moreover, the results indicate that as friction angle increases, probability of sliding between dam and foundation is reduced whereas, increases tensile cracking. Lastly, it is observed that foundation stiffening increases the probability of dam sliding but, reduces the tensile damage in the dam body.

기초지반강성을 고려한 철골 건축구조물의 비선형 지진해석 (Nonlinear Seismic Analysis of Steel Buildings Considering the Stiffnesses of the Foundation-Soil System)

  • 오영희;김용석
    • 한국강구조학회 논문집
    • /
    • 제18권2호
    • /
    • pp.173-180
    • /
    • 2006
  • 구조물의 지진응답은 기초지반조건의 영향을 받는다. 이 연구에서는 고정지반과 연약지반을 고려한 3, 5, 7층 철골 건축구조물의 밑면전단력을 산정하기 위해 선형 시간이력지진해석과 비선형 Pushover 정적지진해석을 수행하였다. 등가정적강성식으로 구한 기초지반강성은 SAP2000의 Link 요소 중 Damper 요소를 사용하여 입력하였다. 범용구조해석 프로그램 SAP2000에 의한 시간이력으로 구한 철골건축구조물의 밑면전단력을 국내내진설계기준, UBC-97 설계응답스펙트럼, Pushover 정적 비선형해석으로 구한 밑면전단력과 비교하였다. 중력하중과 풍하중으로 설계된 철골 건축구조물은 0.11g의 중진에 대해 탄성응답을 보였고, 탄성 연약지반에서 구조물-지반의 상호작용과 지반 증폭에 의해 구조물의 변위와 밑면전단력이 증가되었다. 따라서, 중약진 지역에서의 건축구조물은 연약지반의 특성을 고려하여 탄성지진해석을 수행하는 것이 더 합리적이다.