• 제목/요약/키워드: Graft failure

검색결과 276건 처리시간 0.026초

이식신장의 기능부전을 경험한 환자의 질병체험 (Lived Experience of Kidney Transplant Recipients with Kidney Graft Failure)

  • 황영희;민경옥;손행미
    • 대한간호학회지
    • /
    • 제54권1호
    • /
    • pp.93-105
    • /
    • 2024
  • Purpose: The study aimed to understand the semantic structure and nature of the disease experience of kidney transplant recipients with kidney graft failure by applying phenomenological research methods. Methods: Data were collected between February and September 2021 through individual in-depth interviews with 12 kidney transplant recipients with kidney graft failure. Colaizzi's phenomenological analysis was used to analyze the meaning of the participants' illness experiences. Results: 5 theme clusters and 15 themes were derived. The five theme clusters are as follows: (1) First transplant giving me a second life; (2) Body and mind becoming sick again; (3) Waiting for a re-transplant with hope and worry; (4) Life supported by gratefulness; (5) Having control over my own life. Conclusion: This study shows that kidney transplant recipients with kidney graft failure experience physical and psychological difficulties during the long disease period and require help from many people, including family members, friends, colleagues, and health care providers, to overcome their difficulties.

개존되어 있는 인조혈관(Polytetrafluorethylene)에 정맥성 역류 -1예 보고- (Venous Backflow in a Patent Polytetrafluoroethylene Arteriovenous Graft -A case report-)

  • 전순호
    • Journal of Chest Surgery
    • /
    • 제38권5호
    • /
    • pp.389-390
    • /
    • 2005
  • 대퇴동맥을 통한 검사 후 대퇴동맥 천자부위를 다루는 기준적인 방법은 수동적으로나 기계적으로 압박을 가한 후 4시간 내지 8시간 동안 침상안정을 취하는 것이었다, 그러나 이러한 방법은 심한 불편함과 퇴원을 지연시키는 문제점이 발생하였다. 이에 따라 최근에 지혈을 위한 많은 장치들이 계발되었다. 이러한 장치들은 국소적인 지혈을 촉진하기 위해 콜라겐을 사용하고 있다. 하지만 이런 장치들을 사용함에 따른 많은 문제점들이 국제적으로 보고되고 있다. 그리고 본원에서는 안지오-씰 사용으로 인한 우측 대퇴동맥과 슬와 동맥에 발생한 혈전증을 수술로 성공적으로 치료한 결과를 얻어서 이를 보고하는 바이다.

일측 폐 이식 후 발생한 이식편 부전으로 양측 폐 재이식을 시행한 1예 보고 (Successful Bilateral Lung Retransplantation in a Patient with Primary Graft Failure Following a Single Lung Transplantation)

  • 황정주;정은규;김재호;이두연;백효채
    • Journal of Chest Surgery
    • /
    • 제39권6호
    • /
    • pp.490-494
    • /
    • 2006
  • 말기 폐질환 환자에서 폐이식은 가장 효과적인 치료이나 원발성 이식부전은 아직도 이식 후 합병증과 사망률 증가의 주 요인이 된다. 폐기종으로 진단된 52세 남자 환자가 지속적 호흡기 치료 및 기관절개 상태에서 좌측 폐이식 수술을 시행 받았다. 본 환자는 이식술 후 발생한 원발성 이식부전으로 호흡기 발관이 불가하여 재이식이 결정되었다. 환자는 인공심폐기 하에 순차적으로 양측 폐이식 수술을 시행 받았으며 현재 퇴원하여 건강하게 일상생활을 하고 있다. 폐이식 수술 후에 발생하는 이식부전이 있으면 가급적 빠른 시일 내에 재이식 수술을 시행하는 것이 예후에 중요하다.

임플란트 및 골이식술과 관련된 세균감염 (Bacterial infections after implant surgery and alveolar bone graft)

  • 팽준영
    • 대한치과의사협회지
    • /
    • 제53권5호
    • /
    • pp.298-306
    • /
    • 2015
  • Bacterial infection after implant installation or bone graft is a serious complication. Bone grafts represent a temporary foreign body lacking vascularisation and are therefore of increased susceptibility to infection, which may be introduced either intraoperatively or postoperatively. Bone graft-associated infections are due to biofilm formation on the surface of the bone graft and often require removal of the infected bone graft with substantial graft failure. In this review, the implant and graft related infection, the role of biofilm and the management will be discussed.

Do Certain Conditions Favor the Use of Autogenous Bone Graft Over Bone Substitutes for Maxillary Sinus Augmentation?

  • Lee, Ji-Hyun;Cho, Yeong-Cheol;Sung, Iel-Yong;Choi, Jong-Ho;Son, Jang-Ho
    • Journal of Korean Dental Science
    • /
    • 제12권2호
    • /
    • pp.48-57
    • /
    • 2019
  • Purpose: To investigate whether there are specific surgical or clinical conditions where the use of autogenous bone (AB) is superior to the use of bone substitutes (BSs) for maxillary sinus floor augmentation (MSFA). Materials and Methods: We retrospectively analyzed 386 implants after MSFA in 178 patients. The implants were divided into five groups according to the sinus graft material used. Risk factors for implant failure in MSFA, and correlation between residual bone height (RBH) and graft materials in terms of implant survival were investigated. To investigate risk factors for implant failure in MSFA, implant survival according to graft materials, patients' sex/age, surgical site, RBH, healing period prior to prosthetic loading, staged- or simultaneous implantation with MSFA, the crown-to-implant ratio, prosthetic type, implant diameter, and opposite dentition were evaluated. Result: The cumulative 2- and 5-year survival rates of implants placed in the grafted sinus (independent of the graft material used) were 98.7% and 97.3%, respectively. None of the investigated variables were identified as significant risk factors for implant failure. There was also no statistical significance in implant survival between graft materials. Conclusion: There were no specific surgical conditions in which AB was superior to BSs in terms of implant survival after MSFA.

Non-Anastomotic Rupture of a Woven Dacron Graft in the Descending Thoracic Aorta Treated with Endovascular Stent Grafting

  • Lee, Youngok;Kim, Gun-Jik;Kim, Young Eun;Hong, Seong Wook;Lee, Jong Tae
    • Journal of Chest Surgery
    • /
    • 제49권6호
    • /
    • pp.465-467
    • /
    • 2016
  • The intrinsic structural failure of a Dacron graft resulting from the loss of structural integrity of the graft fabric can cause late graft complications. Late non-anastomotic rupture has traditionally been treated surgically via open thoracotomy. We report a case of the successful use of thoracic endovascular repair to treat a Dacron graft rupture in the descending aorta. The rupture occurred 20 years after the graft had been placed. Two stent grafts were placed at the proximal portion of the surgical graft, covering almost its entire length.

Total lymphoid irradiation based conditioning for hematopoietic stem cell transplantation in severe aplastic anemia

  • Lee, Yun-Hee;Kim, Ji-Yoon;Choi, Byung-Ock;Ryu, Mi-Ryeong;Chung, Su-Mi
    • Radiation Oncology Journal
    • /
    • 제30권4호
    • /
    • pp.165-172
    • /
    • 2012
  • Purpose: To retrospectively evaluate the outcome and toxicity of total lymphoid irradiation (TLI) based conditioning regimen for allogeneic hematopoietic stem cell transplantation (HSCT) in severe aplastic anemia (SAA) patients who experienced an engraftment failure from prior HSCT or were heavily transfused. Materials and Methods: Between 1995 and 2006, 20 SAA patients received TLI for conditioning of HSCT. All patients were multi-transfused or had long duration of disease. Fifteen (75%) patients had graft failure from prior HSCT. In 18 (90%) patients, the donors were human leukocyte antigen identical siblings. The stem cell source was the peripheral blood stem cell in 15 (75%) patients. The conditioning regimen was composed of antithymocyte globulin plus TLI with a median dose of 750 cGy in 1 fraction. The graft-versus-host disease (GVHD) prophylaxis used cyclosporine with methotrexate. Results: With a median follow-up of 10.8 years, graft failures developed in 6 patients. Among them, 3 patients received their third HSCT to be engrafted finally. The Kaplan-Meier overall survival rate was 85.0% and 83.1% at 5 and 10 years, respectively. The incidence of acute and chronic GVHD was 20% and 20%, respectively. None of the patients have developed a malignancy after HSCT. Conclusion: In our study, TLI based conditioning in allogeneic HSCT was feasible with acceptable rates of GVHD in SAA patients who experienced graft failure from prior HSCT or was at a high risk of graft rejection. We achieved relatively better results of engraftment and survival with a long term follow-up.

Xenograft Failure of Pulmonary Valved Conduit Cross-linked with Glutaraldehyde or Not Cross-linked in a Pig to Goat Implantation Model

  • Kim, Dong Jin;Kim, Yong Jin;Kim, Woong-Han;Kim, Soo-Hwan
    • Journal of Chest Surgery
    • /
    • 제45권5호
    • /
    • pp.287-294
    • /
    • 2012
  • Background: Biologic valved grafts are important in cardiac surgery, and although several types of graft are currently available, most commercial xenografts tend to cause early disfiguration due to intimal proliferation and calcification. We studied the graft failure patterns on non-fixed and glutaraldehyde-fixed pulmonary xenograft in vivo animal experiment. Materials and Methods: Pulmonary valved conduits were obtained from the right ventricular outflow tract of eleven miniature pigs. The grafts were subjected to 2 different preservation methods; with or without glutaraldehyde fixation: glutaraldehyde fixation (n=7) and non-glutaraldehyde fixation (n=4). The processed explanted pulmonary valved grafts of miniature pig were then transplanted into eleven goats. Calcium quantization was achieved in all of the explanted xenograft, hemodynamic, histopathologic and radiologic evaluations were performed in the graft which the transplantation period was over 300 days (n=7). Results: Grafts treated with glutaraldehyde fixation had more calcification and conduit obstruction in mid-term period. Calcium deposition also appeared much higher in the glutaraldehyde treated graft compared to the non-glutaraldehyde treated graft (p<0.05). Conclusion: The present study suggests that xenografts prepared using glutaraldehyde fixation alone appeared to have severe calcification compared to the findings of non-glutaraldehyde treated xenografts and to be managed with proper anticalcification treatment and novel preservation methods. This experiment gives the useful basic chemical, histologic data of xenograft failure model with calcification for further animal study.

Risk Factors of Allogenous Bone Graft Collapse in Two-Level Anterior Cervical Discectomy and Fusion

  • Woo, Joon-Bum;Son, Dong-Wuk;Lee, Su-Hun;Lee, Jun-Seok;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권4호
    • /
    • pp.450-457
    • /
    • 2019
  • Objective : Anterior cervical discectomy and fusion (ACDF) is commonly used surgical procedure for cervical degenerative disease. Among the various intervertebral spacers, the use of allografts is increasing due to its advantages such as no harvest site complications and low rate of subsidence. Although subsidence is a rare complication, graft collapse is often observed in the follow-up period. Graft collapse is defined as a significant graft height loss without subsidence, which can lead to clinical deterioration due to foraminal re-stenosis or segmental kyphosis. However, studies about the collapse of allografts are very limited. In this study, we evaluated risk factors associated with graft collapse. Methods : We retrospectively reviewed 33 patients who underwent two level ACDF with anterior plating using allogenous bone graft from January 2013 to June 2017. Various factors related to cervical sagittal alignment were measured preoperatively (PRE), postoperatively (POST), and last follow-up. The collapse was defined as the ratio of decrement from POST disc height to follow-up disc height. We also defined significant collapses as disc heights that were decreased by 30% or more after surgery. The intraoperative distraction was defined as the ratio of increment from PRE disc height to POST disc height. Results : The subsidence rate was 4.5% and graft collapse rate was 28.8%. The pseudarthrosis rate was 16.7% and there was no association between pseudarthrosis and graft collapse. Among the collapse-related risk factors, pre-operative segmental angle (p=0.047) and intra-operative distraction (p=0.003) were significantly related to allograft collapse. The cut-off value of intraoperative distraction ${\geq}37.3%$ was significantly associated with collapse (p=0.009; odds ratio, 4.622; 95% confidence interval, 1.470-14.531). The average time of events were as follows: collapse, $5.8{\pm}5.7months$; subsidence, $0.99{\pm}0.50months$; and instrument failure, $9.13{\pm}0.50months$. Conclusion : We experienced a higher frequency rate of collapse than subsidence in ACDF using an allograft. Of the various preoperative factors, intra-operative distraction was the most predictable factor of the allograft collapse. This was especially true when the intraoperative distraction was more than 37%, in which case the occurrence of graft collapse increased 4.6 times. We also found that instrument failure occurs only after the allograft collapse.

3개월 이하 영아의 대동맥 축착증 수술치료에 대한 임상연구 (Correction of Coarctation in Infants Less than Age 3 Months)

  • 신제균;송명근
    • Journal of Chest Surgery
    • /
    • 제23권6호
    • /
    • pp.1139-1145
    • /
    • 1990
  • Seven infants less than age 3 months underwent patch aortoplasty and tube graft bypass for relief of coarctation of aorta. All had intractable congestive heart failure, despite aggressive medical therapy Each infant had other cardiac anomalies including patent ductus arteriosus, ventricular septal defect, atrial septal defect and congenital mitral stenosis. All patients underwent closure of the ductus arteriosus and patch angioplasty of the aorta to produce a luminal diameter of at least 15mm or tube graft interposition utilizing the Gortex tube graft diameter larger than 10mm. In 5 patients who had ventricular defect, they underwent pulmonary arterial banding. &ere was one hospital death 17 days after operation secondary to the hydronephrosis and renal failure. Hospitalization was less than 10 days after operation except one case. In 3 patients who had associated VSD, open heart surgery[VSD closure+PA debanding]was done without difficulty. Surgical repair of critical coarctation of the aorta in infants can safely be offered despite the poor preoperative condition and presence of other cardiac anomalies.

  • PDF