• 제목/요약/키워드: Gradient echo sequence

검색결과 80건 처리시간 0.025초

The assessment of tumoral necrosis in rat tumor model using dynamic T1/T2* gradient dual echo sequence with Gd-DTPA and Gadomer-17 as a MR contrast agent

  • 허용민;김대홍;김은주;송호택;서진석;이상훈
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.93-93
    • /
    • 2003
  • To test the feasibility of rBF and rBVin the assessment of R004 sarcomas of the rat and to compare the results obtained by using Gd-DTPA and Gadomer-17 as a MR contrast agent, on the basis of the histological findings of tumor necrosis.

  • PDF

고온초전도 선재와 정합회로를 이용한 RF coil 제작에 대한 기초연구 (Study on fabricated RF coil using high-temperature superconductor tape and matching circuit for low field MRI system)

  • 김동혁;고락길;강부민;하동우;손명환;문치웅
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권1호
    • /
    • pp.44-47
    • /
    • 2012
  • The substantial improvement of the signal-to-noise ratio (SNR) can be achieved with small-size samples or low-field MRI system by high-temperature superconducting(HTS) RF coil. The typical HTS RF coil made of HTS thin film is expensive and is limited the coil geometry to planar surface coil. In this study, commercial Bi-2223 HTS tapes was used as RF coil for a 0.35T permanent MRI system. It has advantages of both much lower cost and easier fabrication over HTS thin film coil. SNR gain of the image obtained from the HTS RF coil over a conventional Cu RF coil at room temperature was about 2.4-fold and 1.9-fold using the spin echo pulse sequence and gradient echo pulse sequence respectively.

음릉천(陰陵泉)(Sp9)의 전침자극(電鍼刺戟)이 functional MRI상 뇌활성(腦活性) 변화(變化)에 미치는 영향(影響) (A fMRI study on the cerebral activity induced by Electro-acupuncture on Sp9(Yinlingquan))

  • 김정호;이현;임윤경;홍권의;이병렬;김연진
    • Journal of Acupuncture Research
    • /
    • 제20권4호
    • /
    • pp.114-133
    • /
    • 2003
  • Objective : The meridian theory in oriental medicine explains that Sp9(Yinlingquan) has been considered very important for gynecological disorders, spleen and stomach disorders, and water metabolic disorders. Functional MRI is the best method of showing the evidences of the effect of the Electro-acupuncture treatment through scientific methods. On this supposition, Electro-acupuncture stimulation on Sp9(Yinlingquan) was carried out on six healthy volunteers, using the gradient echo sequence with the 3.0T whole-body MRI system(ISOL). Methods : Electro-acupuncture stimulation on Sp9(Yinlingquan), the experiment was carried out on six healthy volunteers, using the gradient echo sequence with the 3.0T whole-body MRI system(ISOL). After the needle insertion on right Sp9(Yinlingquan), 2Hz of electric stimulation was given for 30 seconds, repeated five times, with 30 seconds' intervals. The Image analysis including motion correction, talairach transformation, and smoothing was done using SPM99. Results : The electro-acupuncture stimulation on Sp9(Yinlingquan) activates Brodmann Area 13, 19, 22, 39, 40, 47 which may be the central pathways of the electro-acupuncture stimulation on Sp9(Yinlingquan). We also hypothesize that those brain areas may be directly or indirectly related with the mechanism of the effect of electro-acupuncture stimulation on Sp9(Yinlingquan).

  • PDF

IBASPM을 이용한 해마체적 측정에서 뇌 Atlases에 대한 고찰 (A Study of brain Atlases in Hippocampus Volume Measurement Using IBASPM)

  • 김주호;이주원;김성후
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 추계학술대회
    • /
    • pp.981-984
    • /
    • 2014
  • IBASPM(Individual Brain Atlases using Statistical Parametric Mapping Software)를 이용하여 해마의 체적 측정시, Atlas의 종류(Atlas69, Atlas71, Atlas84, Atlas116)에 따른 체적의 변화를 평가하기 위해 20대 정상 성인 10명(남5/여5, $23.3{\pm}2.66$)으로부터 뇌 영상을 획득하였다. 1.5T MRI system(Siemens, Avanto, Erlangen, Germany)의 머리 격자코일(Head matrix coil)을 사용하여 3차원 경사에코 펄스 열(3-D gradient echo pulse sequence)인 MPRAGE(Magnetization Prepared Rapid Acquisition Gradient Echo)영상을 획득하였다. Atlas의 종류에 따라 획득된 해마의 체적을 이용하여 대응표본 t 검정(Paired t-test)을 수행한 결과, 좌측 해마옆이랑(parahippocampal gyrus - left) Atlas69-Altas84, Atlas69-Atlas116(p=0.729, 0.729), 우측 해마형성체(hippocampal formation - right) Atlas69-Atlas84, Atlas69-Atlas116(p=0.219, 0.219)는 유의한 차이가 없었으며, 이를 제외한 부분에서 유의한 차이가 있었다(p=0.000). 그러고 Atlas84와 Atlas116을 이용한 해마의 체적은 모두 동일한 값을 나타내어 유의한 차이가 없었다(p=0.000). Atlas영상과 원본 영상의 overlay를 이용한 영상분석에서는 Atlas71에서만 해마의 부위가 잘 못 정합되는 것을 발견할 수 있었다. 본 연구에 사용된 Atlas의 경우에는 서양인을 바탕으로 개발되었기 때문에 동양인의 뇌와는 차이가 있으며, 정확성 높은 체적의 측정을 위해서는 상황에 맞는 Atlas의 개발이 필요할 것으로 사료된다.

  • PDF

두 개내 초급성 출혈 : EPI와 다른 MR 영상 기법의 비교 (Hyperacute Intracerebral Hemorrhage : Comparison of EPI and Other MR Sequence)

  • 김정희;김옥화;서정호;박용성
    • Investigative Magnetic Resonance Imaging
    • /
    • 제3권2호
    • /
    • pp.167-172
    • /
    • 1999
  • 목적 : Echo planar image (EPn와 다론 MR 영상기법에서 2시간 이내의 초급성 출혈의 발견율의 차이를 비교해 보고자 한다. 대상 및 방법 : 인위적으로 뇌출혈을 유발시킨 백서 10마리를 대상으로 EP1, 급속 스핀에코 (FSE) T2 강조영상, Fluid attenuated inversion recovery (FLAIR) 영상, 스펀에코 (SE) Tl 강조영상과 Tl 강조 Gradient echo (GE) 영상을 이용하여, 뇌출혈을 일으킨 2시간 후에 MR 촬영을 하였다. 추가적으로 3마리는 출혈 30분 후에, 6마리는 1시간 후에 각각 EPI와 FSE T2 강조영상을 얻었다. 얻어진 영상에 대한 주관적인 시각적 평가를 하기위하여 세명의 방사선과 의사가 출혈 병변이 어느 MR 영상 기법에서 제일 잘 보이는지를 평가하였다. 정량적인 평가 로는 병변-정상 뇌설질의 대조잡음비(contrast-to-noise ratio, CNR)를 측정하였다. 통계처리는 Wilcoxon-Ranks test를 이용하였다. 결과 : 시각적 평가에서 출혈 병변이 높은 신호강도로 나타난 EP1, FLAIR, FSE T2 영상 중 EPI 영상이 특히 높은 신호강도로 나타나 제일 쉽게 병변이 구별되었다. 정량적인 평가에서 출혈 병 변-정상 뇌설질의 CNR은 EPI와 FLAIR 영상에서 다른 세 영상기법에 비해 통계적으로 유의하게 우월하였다 (p<0.01). 그러나 EPI와 FLAIR 영상간의 CNR은 동계적으로 유의한 차이가 없었다 (p>0.10). 추가적으로 출혈 30분과 1l시간 후 촬영한 모두에서 EPI영상과 FSE T2 강조 영상은 정상에 비해 높은 신호강도를 보여 병변의 구별이 가능하였다. 결론 : 백서에서 유발시킨 초급성기 뇌출혈의 여러 기법의 MR 영상 중 EPI 영상이 영상획득 시간이 가장 빠르면서 시각적 평가와 정량적 평가에서 출혈의 발견율이 가장 높아 출혈의 선속한 진단에 유용할 것으로 생각된다.

  • PDF

Isolated Cortical Vein Thrombosis with Long Cord Sign

  • Ban, Seung Pil;Chung, Young Seob;Park, Sung Bae;Son, Young-Je
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권5호
    • /
    • pp.476-478
    • /
    • 2015
  • Isolated cortical vein thrombosis (ICVT) is a rare disease, accounting for less than 1% of strokes. A 46-year-old woman presented with progressive left side weakness. Magnetic resonance (MR) imaging with $T2^*$-gradient echo ($T2^*$-GE) sequence showed long cord sign at the right frontal cortex. The patient was treated with low molecular weight heparin, followed by oral warfarin for 6 months. The 3-month follow-up MR imaging showed recanalization of the previously thrombosed cortical vein. She was completely recovered without neurological deficits after 6 months. This provides that MR imaging with $T2^*$-GE sequence can help to diagnosis the ICVT and outcomes of the ICVT are generally favorable.

주파수 변조 DANTE를 이용한 자화율 효과의 감소 (Reduction of Susceptibility Effect Using Frequency Modulation DANTE)

  • 정성택;홍인기;김지훈;노용만;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.167-170
    • /
    • 1995
  • An frequency modulated (FM) DANTE pulse sequence generates a quadratic phase toward the transverse of image by an FM RF pulse. In the image of a serious susceptibility effect, the phase due to the difference of the susceptibility in the pixel occurs susceptibility error which arise signal loss. But the signal loss due to the susceptibility effect in the pixel is reduced when the quadratic phase adds in the pixel. In this paper, we have generated a quadratic function toward the transverse (X-Y) using FM DANTE sequence and the susceptibility effect is reduced in the gradient echo (GE) imaging. Computer simulation and experimental results is obtained by using a whole-body KAIS 2.0T NMR system.

  • PDF

${T_2}weighted$- Half courier Echo Planar Imaging

  • 김치영;김휴정;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제5권1호
    • /
    • pp.57-65
    • /
    • 2001
  • 목적 : 초고속 Echo Planar Imaging (EPI) 의 데이터 측정시간을 반으로 단축시킨 half courier EPI와 임상에서 널리 사용하는 $T_2$ 강조 영상을 결합한 $T_2$-weighted half courier EPI(T2HEPl) 영상기법을 제안하였다. 제안한 방법으로 강한 $T_2$ 대조도를 갖는 $128{\times}128$의 고해상도 EPI 영상을 single scan으로 얻고자 한다. 대상 및 방법 : 초고속 EPI 기법의 데이터 측정시간을 줄이기 위하여 k-space의 절반만을 측정하고, 나머지 절반은 conjugate symmetry 성질을 이용하여 재구성한다. 따라서 64개의 에코로 $128{\times}128$의 고해상도 single shot 영상을 얻을 수 있다. 또한 k-space 데이터의 순서를 시간 축에서 조절하여 강한 $T_2$ 대조도를 갖는 영상을 얻을 수 있다 Eddy current의 영향으로 phase encoding 방향으로 잔류 경사자계가 있을 경우 측정된 데이터들은 k-space에서 이동이 되며 , 이것은 재구성 영상에 심각한 문제점을 초래하게 된다. 본 논문에서는 pre-scan에서 얻은 기준 데이터와 dc에 해당하는 에코간의 상관도를 측정하여 이동을 추정하며, 초기의 phase encoding gradient의 크기를 조정하여 이러한 이동을 제거한다. 결과 : 제안한 $T_2$-weighted half courier EPI 영상기법을 1.0 Tesla 전신 MRI 시스템에 적용하였다. 실험 조건은 single shot으로 TR은 무한대이고, TE는 72ms와 96ms로 설정하였다. 제안한 영상기법을 이용하여 single scan으로 강한 $T_2$ 대조도를 갖는 128x128의 고해상도 EPI 영상을 얻을 수 있었다. 결론 : 제안한 Half Fourier기법을 이용하여 기존의 $64{\times}64$ 영상보다 해상도를 높인 $128{\times}128$ EPI영상을 single scan으로 얻을수 있었으며, 에코의 적절한 배치를 통해 임상에서 널리 사용되는 $T_2$ 대조도를 얻을 수 있었다. 제안한 방법은 특별한 하드웨어의 추가 없이, 펄스 시퀀스와 tuning 및 재구성 알고리즘 등의 소프트웨어적인 방법만으로 구현이 가능하여 많은 임상 응용이 기대된다.

  • PDF

Radiofrequency Coil Design for in vivo Sodium Magnetic Resonance Imaging of Mouse Kidney at 9.4T

  • Lim, Song-I;Woo, Chul-Woong;Kim, Sang-Tae;Choe, Bo-Young;Woo, Dong-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권1호
    • /
    • pp.65-70
    • /
    • 2018
  • The objective of this study was to describe a radiofrequency (RF) coil design for in vivo sodium magnetic resonance imaging (MRI) for use in small animals. Accumulating evidence has indicated the importance and potential of sodium imaging with improved magnet strength (> 7T), faster gradient, better hardware, multi-nucleus imaging methods, and optimal coil design for patient and animal studies. Thus, we developed a saddle-shaped sodium volume coil with a diameter/length of 30/30 mm. To evaluate the efficiency of this coil, bench-level measurement was performed. Unloaded Q value, loaded Q value, and ratio of these two values were estimated to be 352.8, 211.18, and 1.67, respectively. Thereafter, in vivo acquisition of sodium images was performed using normal mice (12 weeks old; n = 5) with a two-dimensional gradient echo sequence and minimized echo time to increase spatial resolution of images. Sodium signal-to-noise ratio in mouse kidneys (renal cortex, medulla, and pelvis) was measured. We successfully acquired sodium MR images of the mouse kidney with high spatial resolution (approximately 0.625 mm) through a combination of sodium-proton coils.

Association of Carotid Intraplaque Hemorrhage and Territorial Acute Infarction in Patients with Acute Neurological Symptoms Using Carotid Magnetization-Prepared Rapid Acquisition with Gradient-Echo

  • Park, Jung Soo;Kwak, Hyo Sung;Lee, Jong Myong;Koh, Eun Jeong;Chung, Gyung Ho;Hwang, Seung Bae
    • Journal of Korean Neurosurgical Society
    • /
    • 제57권2호
    • /
    • pp.94-99
    • /
    • 2015
  • Objective : The purpose of our study was to assess prevalence of carotid intraplaque hemorrhage (IPH) and associations between territorial acute infarction and IPH on magnetization-prepared rapid acquisition with gradient-echo (MPRAGE) in patients with acute neurologic symptoms. Methods : 83 patients with suspected acute neurologic symptoms were evaluated with both brain diffusion weighted imaging (DWI) and carotid MPRAGE sequences. Carotid plaque with high signal intensity on MPRAGE of >200% that of adjacent muscle was categorized as IPH. We analyzed the prevalence of IPH and its correlation with territorial acute infarction. Results : Of 166 arteries, 39 had a carotid artery plaque. Of these arteries, 26 had carotid artery stenosis less than 50%. In all carotid arteries, MR-depicted IPH was found in 7.2% (12/166). High-signal intensity on DWI was found in 17.5% (29/166). Combined lesion with ipsilateral high-signal intensity on DWI and IPH on carotid MPRAGE sequence was found in 6 lesions (6/166, 3.6%). Of patients with carotid artery plaque, MR-predicted IPH was found in 30.8% (12/39) and match lesions with high-signal intensity on DWI and MPRAGE was found in 15.4% (6/39). MR-predicted IPH was significantly higher prevalence in high-grade stenosis group (p=0.010). Relative risk between carotid MPRAGE-positive signal and ipsilateral high-signal intensity on DWI in arteries with carotid artery plaques was 6.8 (p=0.010). Conclusion : Carotid MPRAGE-positive signal in patients was associated with an increased risk of territorial acute infarction as detected objectively by brain DWI. The relative risk of stroke was increased in high-grade stenosis categories.