• Title/Summary/Keyword: Goniometer

Search Result 251, Processing Time 0.026 seconds

The Reliability and Validity of Hip Range of Motion Measurement using a Smart phone Operative Patient (엉덩관절 수술 환자에서 스마트폰을 이용한 관절가동범위 측정의 신뢰도 및 타당도 연구)

  • Park, Sun-Wook;Kim, Myoung-Soo;Bae, Hyo-Sun;Cha, Yong-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.2
    • /
    • pp.1-7
    • /
    • 2015
  • PURPOSE: The aims of this study were to assess the intra-tester and inter-tester reliability and validity of hip range of motion using a smart phone in hip operative patients. METHODS: Twenty-five patients (eight total hip arthroplasty and seventeen femur neck fracture) participated in this study. The range of motions in active and passive hip flexion, abduction and external rotation were measured with a goniometer and smart phone over two times by two observers. The intra-tester and inter-tester reliability were evaluated using the intraclass correlation coefficient (ICC2,1). The validity was measured by Pearson's correlation coefficient RESULTS: The intra-observer reliability was good in all measured items (ICC>0.78). The inter-observer reliability was high with ICC (>0.90). All correlation coefficients of smart phone and goniometer was greater than 0.85 and showed a significant positive correlation (p<0.01). CONCLUSION: The range of motion measurement with a smart phone showed acceptable reliability. Therefore, it could be convenient and have economical benefits to measure the range of motion of the hip joint using a smart phone.

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

A Study of Measurement on Range of Arm Joint Motion of Korean Male in Twenties (한국인 20대 청년의 팔 관절 동작범위 측정 연구)

  • 이영신;이석기;박세진;김철중
    • Proceedings of the ESK Conference
    • /
    • 1995.04a
    • /
    • pp.62-71
    • /
    • 1995
  • This paper measured the range of arm joint motion for Korean 54 male in twenties. The subjects are measured directly using Goniometer and angle gauge. The static measurement variables are seven and the dynamic measurement variables are thirteen. The anthropometric datum are analyzed by basic statistical analysis, correlation analysis and regression analysis using commercial SAS program. The results of analysis are compared with American students anthropometric data by Laubach, 1978.

  • PDF

Old People′s Usability Testing and Design for the User Interface of Washing Machine (세탁기의 사용자 인터페이스에 대한 노인의 사용편의성 평가 및 디자인 개선에 관한 연구)

  • 정광태;송복희
    • Archives of design research
    • /
    • v.16 no.2
    • /
    • pp.49-56
    • /
    • 2003
  • In order to design a product for old people, it is important to identify usability problems through usability test and solve such problems in design process. So, we performed a study on design evaluation and improvement focusing on washing machine, that is one of the most useful electric home appliances in old people's daily life. Also, we studied the method that the goniometer can be used in usability evaluation for a specific part of product and the result can be used in product design. And, methods for the decision of design concept and direction, the development of design alternatives, design evaluation, model making, and comparison test through human factors theory and experiment were studied. The result can be used as an important data in the development of washing machine for old people and the proposed methodology can be used in other products for old people as well as washing machine.

  • PDF

Effect of Surface Free Energies on Mechanical Properties of Epoxy/Polyurethane Blend System (에폭시/폴리우레탄 블렌드 시스템의 표면 자유에너지 변화가 기계적 특성에 미치는 영향)

  • 박수진;진중성;이재락;박병기
    • Polymer(Korea)
    • /
    • v.24 no.2
    • /
    • pp.245-251
    • /
    • 2000
  • A blend system prepared from epoxy(EP) and polyurethane (PU) was investigated in terms of the contact angle and mechanical properties. The contents of EP/PU were varied within 100/0~100/60 phr in the presence of 20 phr DDM (4,4'-diamino diphenyl methane) as a curing agent for epoxy resin. Contact angle measurements were performed employing a Rame-Hart contact angle goniometer. Deionized water and diiodomethane were chosen as the testing liquids. In this work, Owens-Wendt and Wu's models using a geometric mean were studied to analyze the surface free energy of blend system. For the mechanical and toughening properties of the casting specimens, the critical stress Intensity factor ($K_{IC}$) and impact test were performed. Especially, the impact test was carried out at room and cryogenic temperatures. As a result, specific or polar component of the surface free energy of the blend system was largely influenced on the addition of the PU resulting in increasing the impact strength for the excellent low- temperature performance.

  • PDF

Intra-Rater Test-Retest Reliability of Ely's Test Using Smartphone in Patients With Lumbar Extension-Rotation Syndrome

  • Park, Kyue-Nam;Ha, Sung-Min;Chung, Sung-Dae;Kim, Si-Hyun;Jang, Jun-Hyeok
    • Physical Therapy Korea
    • /
    • v.19 no.4
    • /
    • pp.46-54
    • /
    • 2012
  • Ely's test is commonly used to assess rectus femoris muscle flexibility. however, a reliability limit of this test was demonstrated by a previous study. In this study, we present an alternative method using an application for a digital horizontal level in a smartphone (DHLS) to complement the reliability limit of Ely's test. The aim of this study was to examine the reliability of Ely's test using DHLS on the pelvis, compared to using visual observation (VO) of pelvic and hip motions. Nineteen patients with lumbar extension-rotation syndrome were recruited for this study. An examiner examined the rectus femoris flexibility (both pass/fail and goniometer scoring) through Ely's test using both DHLS and VO. A retest session was completed two hours later for within-day reliability and seven days later for between-day intra-rater test-retest reliability. Results showed higher Kappa values for pass/fail scoring and higher intraclass correlation coefficient values for goniometer scoring in Ely's test using DHLS, compared to using VO. Measurement error and Bland and Altman plots further demonstrated the degree of intra-rater variance during Ely's test using DHLS in a clinical setting, compared to using VO. These results demonstrated that Ely's test using DHLS showed acceptable reliability compared to using VO. Ely's test using DHLS could be widely used for measuring the rectus femoris muscle flexibility in patients with lumbar extension-rotation syndrome, although the inter-rater reliability needs to be established first.

The Motion Evaluation of Arthritis Patients' Dressing and Undressing Corresponding to their Joint Range of Motion (관절염질환자의 관절가동범위에 대응한 착탈의 동작평가)

  • Han, Seung-Hee;Choi, Mi-Sung
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.14 no.2
    • /
    • pp.75-87
    • /
    • 2012
  • This study aims at measuring and comparing the joint range of motion(ROM) of the elderly, quantitatively understanding the joint ROM and duration for their dressing and undressing of pants with 3D motion analysis equipment, and thereby providing basic data necessary for the future development of clothes carrying functional designs. The findings are as follows. As for the study method, the 9-item joint ROM measurements were conducted with goniometer, and the questionnaire analyses were carried out for t-test, ANOVA, and regression analysis with spss12.0 program. The 3D motion analyses were handled with 3D Motion Analysis Package Version 3.1 Program. The findings are as follows. First, the ROM was shown to be significantly low, as the arthritis-pain consciousness level was felt higher by the subject than the average one. Seven ROM variables, such as hip flexion, hip adduction, hip internal rotation, hip external rotation, knee flexion, ankle dorsiflexion, and ankle plantar flexion, were shown to significantly affect the discomfort level experienced at the time of dressing or undressing. Second, in the motion of inserting the remaining leg into the pant crotch part(3e), the difference of angles in the hip joint and knee joint was the largest between the women in their 20s and the elderly women with arthritis. Third.

  • PDF

Study of an Optical Goniometer Using a Multi-Photodiode Sensor

  • Kim, Ji-Sun;Kim, A-Hee;Oh, Han-Byeol;Kim, Jun-Sik;Goh, Bong-Jun;Lee, Eun-Suk;Choi, Ju-Hyeon;Baek, Jin-Young;Jun, Jae-Hoon
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.22-28
    • /
    • 2016
  • The monitoring and measurement of the motion of a human joint is very important in screening for degenerative brain diseases and tracking the rehabilitation process. Since there are various medical fields to benefit from angular motion measurement, the necessity for monitoring of human joint movement is increasing. In this study, the optical sensor is composed of a light emission unit with a red LED and an optical fiber, and a reception unit with an arrangement of three photodiodes. The angular detection range was widened with the use of multiple photodiodes and the developed algorithm. The result will be useful for designing an effective angular sensor with low cost and small size.

The Comparison of Muscle Activities in the Right Leg during Squatting According to Various Ankle Angles (다양한 발목각도에 따른 스쿼트 시 오른쪽 다리의 근 활성도 비교)

  • Ahn, Su-Hong;Lee, Su-Kyoung;Lee, Kwang-Jun;Park, Jin-Seong;Hwang, Jea-Woong
    • PNF and Movement
    • /
    • v.15 no.3
    • /
    • pp.259-266
    • /
    • 2017
  • Purpose: This study aimed to compare muscle activities in the right leg during squatting on an angle-adjustable inclined wooden plate at three different angles. Methods: The subjects were 19 healthy adult men and women. An angle-adjustable inclined wooden plate was used for the experiment, and the subjects performed squatting at three adjusted angles of $0^{\circ}$ ankle angle, $10^{\circ}$ ankle flexion, and $10^{\circ}$ plantar flexion. Squatting was randomly performed without a sequence. The knee angle was set at $45^{\circ}$, and a goniometer was used to measure the angles accurately. Electromyography was employed to measure and compare muscle activity in the right leg in each condition. The measured data were converted to root mean square values to calculate the muscle activities. Results: This study showed no statistically significant difference at a $0^{\circ}$ ankle angle, but a statistically significant difference was found in the vastus medialis at $10^{\circ}$ of ankle flexion. Moreover, statistically significant differences were observed in the vastus medialis and lateralis at $10^{\circ}$ of plantar flexion. Conclusion: This study showed a statistically significant difference in the vastus medialis at $10^{\circ}$ of ankle flexion and statistically significant differences in the vastus medialis and lateralis at $10^{\circ}$ of plantar flexion. Therefore, it may be effective to perform squatting at $10^{\circ}$ of ankle flexion when intending to selectively strengthen the vastus medialis and at $10^{\circ}$ of plantar flexion when intending to strengthen both the vastus medialis and lateralis.

The Effect on grasp and pinch strength according to degree of elbow flexion in normal adult (성인의 주관절 굴곡 각도가 파악력과 핀치력에 미치는 영향)

  • Lee, Cu-Rie;Kim, Keun-Jo;Kim, Bonn-Won
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.25-33
    • /
    • 2008
  • Purpose : This study was investigated the effect on grasp and pinch strength according to degree of flexion in elbow joint. Methods : Thirty male and thirty female students, aged 20 to 31 years were tested for using opened positioning with their shoulder abduction at $55^{\circ}$ and shoulder horizontal adduction at $30^{\circ}$ in four elbow flexion($0^{\circ}$, $45^{\circ}$, $90^{\circ}$, $135^{\circ}$). An electronic dynamometer(E-LINK V900s Evaluation System)and goniometer were used to measure grasp and pinch strength. Results : The average grasp strength of the dominant hand was strongest at elbow $45^{\circ}$ however, weakest at elbow $135^{\circ}$ flexion in both of male and female. The average pinch strength of the dominant hand was strongest at elbow $135^{\circ}$ flexion in both of male and female. The average pinch strength of dominant hand was weakest at elbow $45^{\circ}$ flexion in both of male and female. According to degree of elbow flexion in both of male and female, grasp and pinch strength was no significant statistically. In analyzing correlations, the grasp strength of male showed the most significant difference at elbow $45^{\circ}$ & $90^{\circ}$ flexion, and the pinch strength was most significant difference at elbow $0^{\circ}$ & $45^{\circ}$ flexion. Conclusion : In analyzing correlations, the grasp strength of female showed the most significant difference at elbow $90^{\circ}$ & $135^{\circ}$ flexion, and the pinch strength was most significant difference at elbow $45^{\circ}$ & $90^{\circ}$ flexion.

  • PDF