• 제목/요약/키워드: Goniometer

검색결과 252건 처리시간 0.024초

Concurrent Validity of a Universal Goniometer and a Double Meter Inclinometer for Passive Range of Motion in Beagle Dogs

  • Heo, Su-Young;Park, Yun-Sik;Lee, Hae-Beam
    • 한국임상수의학회지
    • /
    • 제34권4호
    • /
    • pp.241-244
    • /
    • 2017
  • The purpose of this study was to evaluate the concurrent validity of the double meter inclinometer (DMI) for passive joint range of motion (ROM) in beagle dogs and to compare these results to a universal plastic goniometer (UPG). Fifteen beagle dogs were recruited for this study. Joint ROM was evaluated twice with each device to calculate the intraobserver reliability. The intraclass correlation coefficient (ICC) values of the UPG were good to excellent (> 0.75) for all joint ROM tests. Similar results were obtained with the DMI. The ICC values of the DMI were good to excellent (> 0.75) except in extension of the tarsal joint (ICC = 0.69). The majority of the ICC results between each device were poor (< 0.50) with the exception of six joints. Our findings suggest that the inclinometer can be used for passive joint ROM in veterinary medicine. However, caution should be taken when comparing measured values of passive joint ROM obtained utilizing both the DMI and UPG.

발목 관절 가동범위 측정을 위한 측정도구의 신뢰도 연구 (Reliability of measurement devices for measuring the ankle joint motion)

  • 홍완성;김기원
    • 대한정형도수물리치료학회지
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2009
  • Purpose: The purposes of this study were to establish the concurrent validity of the universal goniometer and electronic inclinometer for ankle joint of motion, and to determine the inter-tester and the intra-tester reliability of these two instruments. Methods: Subjects were instructed 25 healthy subjects. Ankle range of motion was measured on two separate occasions 2 or 3 days by two physical therapists. Ankle dorsiflexion and plantarflexion was by using an universal goniometer and an electronic inclinometer. Results: The Pearson product-moment correlation between the two instruments was 0.78~0.80. The ICCs for inter-tester reliability ranged from 0.63 to 0.73 for universal goniometer and ranged from 0.81 to 0.88 for electric inclinometer. The ICCs for intra-tester reliability showed a wide variation(ICC=0.61 to 0.86). Conclusion: These findings indicate that the two instruments are reliable instruments for measuring ankle joint range of motion. The results also indicate that the two instruments can be used interchangeably for measuring ankle motions.

  • PDF

목 관절가동범위 측정을 위한 스마트폰 어플리케이션의 유용성 (Usefulness of Smart Phone Application to Measure Cervical Range of Motion)

  • 이춘엽;송해윤;이정민;장문영
    • 대한지역사회작업치료학회지
    • /
    • 제7권1호
    • /
    • pp.17-24
    • /
    • 2017
  • 목적 : 건강한 성인을 대상으로 목의 관절가동범위를 측정하는데 임상에서 간편하게 적용할 수 있는 스마트폰 어플리케이션의 유용성을 확인하고자 한다. 연구방법 : 목의 관절가동범위는 스마트폰 어플리케이션과 각도계로 목의 굽힘, 폄, 오른쪽 돌림, 왼쪽 돌림, 오른쪽 가쪽 굽힘, 왼쪽 가쪽 굽힘의 움직임을 각각 측정하였다. 검사자내 신뢰도와 검사자간 신뢰도를 측정하기 위해 같은 검사자가 두 번, 다른 검사자가 한 번으로 총 세 번 측정을 실시하였다. 검사 순서는 무작위로 하였으며, 두 검사자는 서로 측정한 결과를 알지 못하게 하였다. 결과 : 연구에 참여한 대상자는 남자 9명, 여자 21명이었다. 실험 결과 스마트폰 어플리케이션과 각도계의 평균 각도 비교에서 오른쪽 가쪽 굽힘을 제외한 모든 항목에서 유의한 차이가 없는 것으로 나타났다(p>.05). 스마트폰 어플리케이션과 각도계의 검사자내 신뢰도는 전 움직임에서 ICC값이 .841~.958로, 검사자간 신뢰도는 전 움직임에서 ICC값이 .720~.944로 나타나 모두 높은 수준의 신뢰도를 보였다. 결론 : 스마트폰 어플리케이션과 각도계는 목의 관절가동범위를 측정하는데 신뢰할 수 있는 것으로 나타나, 스마트폰 어플리케이션은 관절가동범위에 신속하고 정확한 측정으로 인해 임상에서 유용한 도구로 활용할 수 있을 것이다.

의복의 기능성 측정을 위한 관절각도법에 관한 비교연구 (Comparison of Range-of-motion test methods for measuring Clothing Mobility)

  • Kim, Young-Hee
    • 한국의류학회지
    • /
    • 제27권12호
    • /
    • pp.1374-1380
    • /
    • 2003
  • 본 연구의 목적은 의복의 기능성 측정의 객관적 평가를 위한 관절각도측정의 방법들 간에 상관관계를 분석하고, 컴퓨터를 이용한 측정방법을 개발, 이를 기존의 방법과 비교, 분석함으로써, 의복의 기능성 측정 및 기능적 디자인 개발에 기여함에 있다. 미국 Kansas 지역의 전문 소방수를 대상으로, 선택된 10가지 실험동작에서의 관절각(range-of-motion)을 computer-aided method, Leighton flexometer, goniometer를 사용하여 측정하였으며, 측정순서는 무작위 순서(random order)로 하였다. 독립변인으로는 3종류의 측정방법(computer-aided method, flexometer, goniometer)이며, 종속변인으로는 선택된 동작에서의 관절각(range-of-motion)이다. 또한 상관분석(correlation analysis)을 실시하여, 상관계수(correlation coefficient)를 측정한 통계처리결과, 각 측정방법들 간에 긍정적이며 유의적인 상관관계가 있는 것으로 나타났다.

The reliability of the nonradiologic measures of thoracic spine rotation in healthy adults

  • Hwang, Donggi;Lee, Ju Hyeong;Moon, Seongyeon;Park, Soon Woo;Woo, Juha;Kim, Cheong
    • Physical Therapy Rehabilitation Science
    • /
    • 제6권2호
    • /
    • pp.65-70
    • /
    • 2017
  • Objective: The purpose of this study was to examine the intertester reliability and validity of four nonradiologic measurements of thoracic spine rotation in healthy adults. Design: Descriptive laboratory study. Methods: This study was conducted on 20 male and 20 female university students aged between 19 and 26. To measure thoracic rotation, a goniometer, a bubble inclinometer, a dual inclinometer, and a smartphone application-clinometer were used. The measurement was performed twice for each device and the same measurement was performed by two examiners. The measurements were performed in the lumbar locked position. The arm in the direction of rotation was taken back and placed onto the back of the lumbar region. With right and left trunk rotation, the head was rotated together but remained in the center line so that the axial rotation was maintained. Both examiners performed the measuring procedures and directly handled the measuring instrument. All measurement results were recorded by the recorder. Results: The range of motion (ROM) of thoracic rotation in lumbar locked position for all four devices was 47 degrees. The intra-rater reliability estimates ranged from 0.738 to 0.906 (p<0.05). The inter-rater reliability estimates ranged from 0.736 to 0.853 (p<0.05). The goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer showed high validity (p<0.05). This result indicates that all four devices may be used by the same examiner and by other examiners obtaining follow-up measurement. Conclusions: The use of the goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer for measurements in the lumbar locked posture are reliable and valid nonradiologic measures of thoracic rotational ROM in healthy adults.

근전도로부터 동적 근력 산정을 위한 수학적 모델 개발 (Development of Mathematical Model to Predict Dynamic Muscle Force Based on EMG Signal)

  • 한정수;정구연;이태희;안재용
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권3호
    • /
    • pp.315-321
    • /
    • 1999
  • 본 논문에서는 근전도의 신호만으로 동적 운동시 근육에 발생하는 근력 예측을 위한 수학적 모델의 개발에 목표를 두고 있다. 이를 위하여 인체의 관절 운동중에 발생하는 근력과 근전도의 상관관계를 규명하는 것이 필요하기 때문에 동역학적 관절모델로서 수근관절을 포함한 주관절이 고려되었으며, 기구학 및 동역학 해석을 위하여 2개의 자유도를 갖는 Flexible Goniometer 로 관절의 각변위, 각속도, 가가속도등의 데이터를 실시간 측정하였다. 근전도 측정을 위해서는 비교적 신호가 뚜렷한 이두박근이 선정되었으며, 운동시 발생하는 이두박근의 근전도 신호는 표면전극을 이용한 다태널 Noraxon EMG 장치로 측정하였다. 결과로서, 근력과 근전도의 측정 시간에 따른 적분값의 비교는 1차 함수의 형태로 비례하는 상관관계로 표현됨을 알 수 있었으며, 동적인 운동시 발생하는 근수축을 동심 수축 구간( Concentric Contraction Period)과 편심 수축 구간(Eccentric Contraction Period)으로 양분하여 분석하였을 때도 근력과 근전도의 측정 시간에 따른 적분값의 비교는 1차 함수의 형태로 비례함을 알 수 있었다. 이 상관관계식을 이용하여 근전도 신호 측정을 통하여 관절에 작용하는 근육의 근력 예측이 가능함을 알 수 있었으며, 각기 다른 신체 부위의 관절에도 적용할 수 있는 가능성을 보여주고 있다.

  • PDF

수제 접촉각 측정기와 영상 분석 프로그램을 이용한 표면에너지의 측정 (Determination of Surface Energy by Means of Home-Made Goniometer and Image Analyzing Software for Contact Angle Measurement)

  • 조서린;조한국
    • 대한화학회지
    • /
    • 제57권4호
    • /
    • pp.432-438
    • /
    • 2013
  • 기초 화학 실험에서 쉽게 만들고 운용할 수 있는 접촉각 측정기를 구성했다. LED 손전등과 시료 거치대, 디지털 카메라를 광학보드에 고정했고, 시료부는 양쪽에 구멍이 뚫린 암실 상자로 덮었다. 공개된 영상분석 프로그램(ImageJ)과 플러그인(Drop_analysis)을 이용해서 고체 표면 위에 형성된 액체 방울의 사진으로부터 접촉각을 측정했다. 구성된 측정기와 해석 프로그램을 이용해 여러 액체와 다양한 표면에서의 접촉각을 측정해 측정기의 성능을 확인했다. 측정된 $H_2O$$CH_2I_2$ 접촉각으로부터 결정된 고체의 표면에너지들은 알려진 값들과 대체로 일치하며 표면의 특성과 개질, 비극성 및 극성 기여도 등을 충실히 보여준다. 이 논문에 소개된 수제 접촉각 측정기와 측정법을 활용해 기초 화학을 배우는 학생들이 젖음성, 친수성, 발수성 등 표면 특성들과 분자 간 상호작용을 이해하고 관련된 힘의 평형, 광학, 수식의 전개 등을 경험할 수 있다.

수직 축 회전형 측각기 제작 및 야외 지표면 반사도 관측 시험: 타프와 잔디에서 (Observation Test of Field Surface Reflectance Using Vertical Rotating Goniometer on Tarp Surface and Grass)

  • 문현동;조은이;김현기;조유나;김보경;안호용;류재현;조재일
    • 대한원격탐사학회지
    • /
    • 제38권6_1호
    • /
    • pp.1207-1217
    • /
    • 2022
  • 농업의 새로운 패러다임인 디지털 농업에서는 원격탐사 기법을 이용하여 작물 생육을 지속으로 감시하며 상태를 신속히 정보화하고 있다. 대표적으로 작물의 생육·생리적 변화에 대한 선택적인 파장 반사도 변화를 기반으로 한 식생지수가 주로 사용되어진다. 하지만 식생 표면의 분광 반사도는 이방성을 갖기 때문에 태양 위치와 지면 관측 방향에 따라 변할 수 있어 식생지수 값이 작물의 상태를 나타내지 못하고 왜곡될 수 있다. 본 연구에서는 야외용 측각기를 제작하여 타프(tarp)와 잔디 식생에서 시험 운영하였다. 램버시안 표면과 유사한 성질의 타프에서는 Blue, Green, Red, 근적외선 파장에 대해 대체적으로 타프의 속성 반사도와 유사하게 측정되었다. 하지만, 흐린 날은 센서 천정각이 커질수록 반사도가 과대 측정되는 경향을 보였다. 잔디에서 주요 식생지수의 상대 차잇값을 보았을 때, 태양과 센서 천정각에 대해 visible atmospherically resistant index (VARI)와 vegetation index green (VIgreen),simple ratio (SR), normalized difference vegetation index (NDVI), enhanced vegetation index (EVI) 순으로 민감하였다. 측각기를 통해서 직접 관측된 자료들은 원격탐사 기반의 반사도 기반 식생지수를 보다 정확하게 산출하는데 기여할 수 있을 것이다.

Novel Technology for View Angle Performance Measurement

  • Rykowski, Ronald;Lee, Jong-Seo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1358-1361
    • /
    • 2008
  • Several different techniques currently exist for measuring display view angle performance. These include conoscopes, goniometric systems, and, most recently introduced to the market, instruments based on Imaging Sphere technology. This paper will compare measurement accuracy and speed of these various methodologies with different FPD types and even 3-D displays.