• Title/Summary/Keyword: Gold cylinder

Search Result 25, Processing Time 0.021 seconds

A Study of Heat Flux on the Height of an Instantaneous Temperature Probe in a Constant Volume Combustion Chamber (정적 연소기에서 순간온도 프로브의 돌출높이에 따른 열유속에 관한 연구)

  • Lee, C.W.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.16 no.4
    • /
    • pp.216-223
    • /
    • 2003
  • In the production of internal combustion engines, there have been trends to develop the high performance engines with improved fuel efficiency, lighter weights and smaller sizes. This trends help to answer problems related to thermal load and abnormal combustion, etc. in these engines. In order to investigate these problems, a thin film-type probe and its manufacturing method for instantaneously measuring surface-temperatures have been proposed in this study, Instantaneous surface temperature of a constant volume combustion chamber was measured by this probe and heat flux was obtained by Fourier analysis. In order to thoroughly understand the characteristics of combustion, the authors measured the wall temperature of the combustion chamber and computed heat flux through a cylinder wall while varying the protrusion height of the probe have been measured. To achieve the above goals, a instantaneous temperature probe was developed, thereby making possible the analysis of the instantaneous temperature of wall surface and the detection of unsteady heat flux in the constant volume combustion chamber.

A Study on Korean Man's Head Ornaments in the Joseon Dynasty (조선시대 남자(男子)의 수식(首飾) 연구(I))

  • Chang, Sook-Whan
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.10 no.1
    • /
    • pp.99-116
    • /
    • 2008
  • This study reviewed pertinent literature and examined relics of manggon(a headband worn to hold a man's topknot hair in place), donggot(a topknot pin), and chigwan(a topknot cover). Before the modernized short hair style, wearing a gat was an important custom. Therefore, manggon, which was used to hold a man's hair in place under the gat, was considered an essential part of the man's official dress code. Donggot is a pin that held the topknot hair in place. It was a must have for a married man, like the binyeo, a lod-like hairpin, for a married woman. Unlike gwanja, it had nothing to do with official rank, but materials were of a variety of materials, including jade and gold. The structure of the donggot was studied in three parts-head, neck and body. Major forms for the head include the mushroom, bean and ball. Bullet and half-cut bullet forms were also found. Forms for the neck include straight-neck and curved-neck. A neck with a belt around a double chin was also found. Forms for the body include the tetrahedron, octahedron and cylinder. The most popular form for silver and white bronze donggot heads was the mushroom, followed by bean and pile forms. Chigwan is also called chipogwan, chichoal, choalgyesogwan, noingwan and sangtugwan. In poetry it was called chichoal, and it used to be called taegogwan in the past as well. Chigwan was so small that it managed to hold a topknot. According to confucian custom in the Joseon period, by wearing chigwan, men didn't display their bare topknot even when they didn't dress up. When they went out, they wore another official hat over the chigwan.

  • PDF

THE DIMENSIONAL CHANGE OF CAST IMPLANT BARS AFTER LABORATORY PROCEDURE

  • Kwon, Ji-Yung;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.354-361
    • /
    • 2007
  • Statement of Problems. The precision of fit between the bearing surfaces of implant abutments and the prosthesis framework has been considered fundamental to implant prosthodontic protocol. Purpose. The study aimed to investigate the effect of laboratory procedure on the dimensional accuracy of cast implant bars. Material and methods Thirty implant bars were fabricated on a metal master model. The gap distances were measured at the right implant abutment replica-gold cylinder interface after casting procedure. The bar length data of precasting and postcasting state were collected and analyzed. Results. The mean gap distance found after casting was $106.3{\mu}m$ for buccal side, $122.1{\mu}m$ for distal side and $117.1{\mu}m$ for the lingual side. The mean bar length was $17964.7{\mu}m$ at precasting measurement, $17891.6{\mu}m$ at postcasting measurement. The mean change of bar length was $-73.1{\mu}m$. Conclusion. Even though the techniques used in this study strictly followed the guidelines established in the literature, the 30 cast implant bars evaluated all yielded gap distances that were beyond acceptable accuracy. There was a statistically significant difference between precasting and postcasting bar length (P<0.01). There was a decreasing tendency in bar length after casting procedure. It was necessary to correct this dimensional change from laboratory procedure by some corrective methods.

The Costumes of 18th Century Joseon Dynasty from Lee Ok's Writings (이옥(李鈺)의 글에 나타난 18세기 조선시대 복식)

  • Choi, Ji-Hee;Hong, Na-Young
    • Journal of the Korean Society of Costume
    • /
    • v.63 no.5
    • /
    • pp.18-34
    • /
    • 2013
  • This paper examines the costumes of 18th century Joseon dynasty that appears in the writings of Lee Ok(李鈺, 1760~1815). The main characteristics that can be inferred about the clothing from his writings are as follows. 1) It suppose that the color of first grade(一品) official uniform was purple. The popular color for the bride's ceremonial dress was red. 2) It was likely that only bridesmaids or married women were allowed to wear Jokduri(ceremonial coronet). 3) White clothes were only preferred in Yeongnam-udo, whereas other regions mainly wore blue, which differs from the national preference for white clothes that was prevalent in the end of the Joseon dynasty. 4) Once cotton was harvested, it only took 5 days to convert it into cotton cloth and be sold on the market. Cotton cloth was one of the most important products during the latter half of the Joseon dynasty. It was common practice in markets to sell expensive costume materials as counterfeits or fungible goods with the intent to cheat. 5) The buddhist monk's hat is various that short cylinder form(短桶帽) and jade or gold headband button(玉圈 金圈) attached shape, etc. Consequently, Lee Ok's writing is a suitable reference for researching Joseon dynasty clothing, since it includes detailed and various descriptions of everyday clothing worn by strict noblemen, which is difficult to find elsewhere.

FINITE ELEMENT ANALYSIS OF CYLINDER TYPE IMPLANT PLACED INTO REGENERATED BONE WITH TYPE IV BONE QUALITY (IV형의 골질로 재생된 골내에 식립된 원통형 임플란트의 유한요소법적 연구)

  • Kim, Byung-Ock;Hong, Kug-Sun;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.4
    • /
    • pp.331-338
    • /
    • 2004
  • Stress transfer to the surrounding tissues is one of the factors involved in the design of dental implants. Unfortunately, insufficient data are available for stress transfer within the regenerated bone surrounding dental implants. The purpose of this study was to investigate the concentration of stresses within the regenerated bone surrounding the implant using three-dimensional finite element stress analysis method. Stress magnitude and contours within the regenerated bone were calculated. The $3.75{\times}10-mm$ implant (3i, USA) was used for this study and was assumed to be 100% osseointegrated, and was placed in mandibular bone and restored with a cast gold crown. Using ANSYS software revision 6.0, a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The present study used a fine grid model incorporating elements between 165,148 and 253,604 and nodal points between 31,616 and 48,877. This study was simulated loads of 200N at the central fossa (A), at the outside point of the central fossa with resin filling into screw hole (B), and at the buccal cusp (C), in a vertical and $30^{\circ}$ lateral loading, respectively. The results were as follows; 1. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were increased from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, concentrated on the top of the cylindrical collar loading point B and C in vertical loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were increase from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in vertical loading. 2. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were decreased from loading point A to C in lateral loading. Stresses according to the depth of regenerated bone were concentrated on the top of the cylindrical collar in loading point A and B, distributed along the implant evenly in loading point C in lateral loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were decreased from loading point A to C in lateral loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in lateral loading. In summary, these data indicate that both bone quality surrounding the regenerated bone adjacent to implant fixture and load direction applied on the prosthesis could influence concentration of stress within the regenerated bone surrounding the cylindrical type implant fixture.