• Title/Summary/Keyword: Glucose

Search Result 10,913, Processing Time 0.047 seconds

The acute toxicity and efficacy evaluation against Aeromonas salmonicida of aquatic drugs oxolinic acid, neomycin-oxytetracycline, and florfenicol in guppy (Poecilia reticulata) (구피(Poecilia reticulata)에서 수산용의약품 oxolinic acid, neomycin-oxytetracycline, florfenicol의 급성독성 및 Aeromonas salmonicida에 대한 약효 평가)

  • Jun Sung Bae;Chae Won Lee;Chan Yeong Yang;Eun Ha Jeong;Areum Kim;Young-Sik Chae;Jung-Jin Park;Kwan Ha Park
    • Journal of fish pathology
    • /
    • v.36 no.2
    • /
    • pp.293-302
    • /
    • 2023
  • This study evaluated the acute toxicity induced by oxolinic acid (OA), neomycin-oxytetracycline combination (NEO-OTC) and florfenicol (FF) administered to guppy (Poecilia reticulata) by comparing standard formulations with commercial preparations (COOaqua curinpotion, COOaqua terafinpotion and COOaqua profenpotion, respectively) for ornamental fish at concentrations of 2-4%. NEO-OTC exhibited the highest acute toxicity in guppy, with no difference observed between the pstandard formulation and commercial preparation (LC50 = 126.08 mg/L and 112.44 mg/L, respectively). OA acute toxicity was assessed in the form of sodium salt, with an LC50 of 504.61 mg/L for the standard formulation and a slightly increased toxicity of 316.11 mg/L for the commercial preparation. In contrast, no mortality was observed during the 96-hour exposure period with the standard formulation in the form of oxolinic acid. The acute toxicity of FF was measured to be above 1,000 mg/L for the standard formulation; however, the commercial preparation significantly increased to 158.53 mg/L. These results indicate that toxicity can significantly increase in commercial formulations, especially those with low levels of active ingredients. This is presumed to be attributed to the organic solvents or solubilizing agents present in the commercial preparations, which may enhance toxicity. Additionally, guppy infected with Aeromonas salmonicida were effectively protected against mortality by administering OA, NEO-OTC and FF at concentrations of 50 mg/L, 100 mg/L and 15 mg/L, respectively, for 2 hours and at half the dose for 24 hours. This result indicates that liquid formulations containing low concentrations of antibiotics may partially increase toxicity, but there is no problem in effectively treating diseases in ornamental fish.

Nutritional and functional constituents and antioxidant activity in whole onion (Allium cepa L.) by growth stage (생육시기별 양파 전초의 영양 및 기능성 성분과 항산화 활성 비교)

  • Sun-Kyung Lee;You-Seok Lee;Soo-Hyun Ji;Pyo-Hyeon Kim;Ju-Hyun Kim;Seong-Jun Kim;Kyung-Cheol Ma;Jin-Woo Lee
    • Food Science and Preservation
    • /
    • v.30 no.5
    • /
    • pp.833-846
    • /
    • 2023
  • Onions are essential vegetables for Koreans' diet and have various physiological activities. However, problems arise every year due to the imbalance between production and demand. Therefore, in this study, nutritional and functional components, and antioxidant activity were analyzed for each growth period in order to utilize onions at the disposal period. Whole onions harvested before June showed higher values of general ingredients, inorganic ingredients, organic acids, spiraeoside, quercetin, total chlorophyll, and antioxidant activity than bulbs harvested in June. On the other hand, the free sugar content was higher in the bulb of the harvest season in June than in whole onions. The total thiosulfinate content was similar to that of whole onions and bulbs in the early stages of growth. In addition, as a result of comparing the flavonoid compound and antioxidant activity of each onion variety, whole onions harvested at 25 weeks were higher in content than onion bulbs harvested in June. In conclusion, onions before the harvest season in June had excellent utilization value as food. Harvesting before 21 weeks is desirable for growing onions with excellent nutritional value, while harvesting after 23 weeks is recommended for excellent functional components and antioxidant activity in onions.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

The causative organisms of pediatric empyema in Korea (소아 농흉 원인균에 대한 다기관 연구(1999. 9-2004. 8))

  • Yum, Hye-yung;Kim, Woo Kyung;Kim, Jin Tak;Kim, Hyun Hee;Rha, Yeong Ho;Park, Yong Min;Sohn, Myung Hyun;Ahn, Kang Mo;Lee, Soo Young;Hong, Su Jong;Lee, Hae Ran
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.1
    • /
    • pp.33-39
    • /
    • 2007
  • Purpose : In spite of medical advances, empyema is a serious complication of pneumonia in children. Vaccination practices and antibiotic prescribing practices promote the change of clinical manifestations of empyema and causative organisms. So we made a nationwide clinical observation of 122 cases of empyema in children from 32 hospitals during the 5 year period from September 1999 to August 2004. Methods : Demographic data, and clinical information on the course and management of empyema patients were collected retrospectively from medical records in secondary and tertiary hospitals in Korea. Results : One hundred twenty two patients were enrolled from 35 hospitals. The most frequent age group was 1-3 years, accounting for 48 percent of all cases. The male to female sex ratio was 1.2:1. The main symptoms were cough, fever, respiratory difficulty, lethargy and chest pain in order of frequency. Hematologic findings on admission revealed decreased hemoglobin levels ($10.4{\pm}1.6g/dL$) and increased leukocyte counts ($16,234.3{\pm}10,601.8/{\mu}L$). Pleural fluid obtained from patients showed high leukocyte counts ($30,365.8{\pm}64,073.0/{\mu}L$), high protein levels ($522.3{\pm}1582.3g/dL$), and low glucose levels ($88.1{\pm}523.5mg/dL$). Findings from pleural fluid cultures were positive in 80 cases(65.6 percent). The most common causative agent was Streptococcus pneumoniae. The majority of patients were treated with antibiotics and closed drainage. Some patients needed open drainage (16.4 percent) or decortication (3.3 percent). The mean duration of hospitalization was $28.6{\pm}15.3days$. Conclusion : We analyzed childhood empyema patients during a period of 5 years in Korean children. The most frequent age group was 1-3 years and the most common causative agent was Streptococcus pneumoniaeiae. The majority of patients were treated with antibiotics and close drainage.

Influence of Nutritional Supplementation to the Substrate on Vegetative and Reproductive Growth of Winter Mushroom, Flammulina velutipes (Curt. ex Fr.) Sing. and Chemical Changes of the substrates Produced during Growth of the Fungus (톱밥 배지(培地)에 대(對)한 영양첨가(營養添加)가 팽이버섯의 생장(生長)및 배지(培地)의 화학적(化學的) 성분(成分) 변화(變化)에 미치는 영향(影響))

  • Chang, Hak-Gil
    • The Korean Journal of Mycology
    • /
    • v.4 no.1
    • /
    • pp.31-44
    • /
    • 1976
  • The studies were carried out to examine the effects of supplementation of nutritional substances and physical conditions in substrate on the mycelial growth and yield of fresh sporophores of winter mushroom, Flammulina velutipes(Curt. ex Fr.) Sing. and to obtain further informations on the nutritional requirements of the fungus with reference to improvement of substrate through [analysis of chemical composition of the substrates during the cultivation period. The results obtained are summarized as follows: 1. The best yield of fresh sporophores, 84.4 g per 280 g substrate in a bottle, was obtained from the mixture of poplar sawdust 10 and rice bran 3 by volume when Flammulina velutipes was cultivated on the poplar sawdust supplemented by rice bran, wheat bran, cattle manure and various combinations of these materials as nutrient sources. The substrates of poplar sawdust 10 plus rice bran 3 and 2 or wheat bran 3 with a higher yield of fresh sporophores showed a comparatively higher content of total nitrogen. total sugar, and potassium. 2. The mycelial growth of the fungus was compared on the substrates of poplar sawdust supplemented by the several nutrient sources and poplar sawdust alone. The fastest linear growth occurred on substrates of poplar sawdust alone and poplar sawdust plus cattle manure deficient in sugar and nitrogen sources, but mycelial density was more sparse on the substrates. Also, growth in a solution extracted from these substrates was very meager. 3. In the substrates which varied with bulk density and moisture content optimum bulk density and moisture content for mycelial growth was 0.2g/cc and 72% on a dry weight basis, respectively, but the highest yield of fresh sporophores was obtained at the bulk density of 0.3g/cc and moisture content of 67%. 4. By increasing the ratio of rice bran in poplar sawdust the loss of total weight and ash, content at each stage was increased, and during the cultivation period of 75 days, loss of total weight of the substrates at inoculation was 17.8 to 28.8% and ash content increased about 12%. 5. 11 to 14% of the cellulose and 3 to 4% of the lignin content per original substrate were decreased without a great difference depending of the mixing ratio of rice bran. The soluble glucose concentration in the substrates was increased during the same period. 6. In the process of vegetative and reproductive growth of the fungus upon the substrates, the total nitrogen was increased in quantity per dry weight of sample but was reduced in absolute quantity to a minute extent. There is no great changes in content of organic nitrogen including amino acid nitrogen, and hydrolysable ammonium nitrogen during the vegetative growth period, but occurrence of sporophores resulted in a decrease in the nitrogen content of these forms. On the one hand, by an increase of additive amounts of rice bran, nitrogen contents of these forms were higher and the reduction range during the reproductive growth period became wider. 7. Mycelial growth of the fungus was accelerated in various liquid media supplemented with organic nitrogen sources such as peptone and yeast extract in comparison with addition of inorganic nitrogen sources. Furthermore, mycelial growth was mere vigorous in the media with higher content of organic nitrogen sources.

  • PDF

A Pilot Study for the Feasibility of F-18 FLT-PET in Locally Advanced Breast Cancer: Comparison with F-18 FDG-PET (국소진행성 유방암에서 F-18 FLT-PET 적용 가능성에 대한 예비 연구: F-18 FDG-PET와 비교)

  • Hyuen, Lee-Jai;Kim, Euy-Nyong;Hong, Il-Ki;Ahn, Jin-Hee;Kim, Sung-Bae;Ahn, Sei-Hyun;Gong, Gyung-Yup;Kim, Jae-Seung;Oh, Seung-Jun;Moon, Dae-Hyuk;Ryu, Jin-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.29-38
    • /
    • 2008
  • Purpose: The aim of this study was to investigate the feasibility of 3 ' -[F-18]fluoro-3 ' -deoxythymidine positron emission tomography(FLT-PET) for the detection of locally advanced breast cancer and to compare the degree of FLT and 2' -deoxy-2 ' -[F-18]fluoro-d-glucose(FDG) uptake in primary tumor, lymph nodes and other normal organs. Material & Methods: The study subjects consisted of 22 female patients (mean age; $42{\pm}6$ years) with biopsy-confirmed infiltrating ductal carcinoma between Aug 2005 and Nov 2006. We performed conventional imaging workup, FDG-PET and FLT PET/CT. Average tumor size measured by MRI was $7.2{\pm}3.4$ cm. With visual analysis, Tumor and Lymph node uptakes of FLT and FDG were determined by calculation of standardized uptake value (SUV) and tumor to background (TB) ratio. We compared FLT tumor uptake with FDG tumor uptake. We also investigated the correlation between FLT tumor uptake and FDG tumor uptake and the concordant rate with lymph node uptakes of FLT and FDG. FLT and FDG uptakes of bone marrow and liver were measured to compare the biodistribution of each other. Results: All tumor lesions were visually detected in both FLT-PET and FDG-PET. There was no significant correlation between maximal tumor size by MRI and SUVmax of FLT-PET or FDG-PET (p>0.05). SUVmax and $$SUV_{75} (average SUV within volume of interest using 75% isocontour) of FLT-PET were significantly lower than those of FDG-PET in primary tumor (SUVmax; $6.3{\pm}5.2\;vs\;8.3{\pm}4.9$, p=0.02 /$SUV_{75};\;5.3{\pm}4.3\;vs\;6.9{\pm}4.2$, p=0.02). There is significant moderate correlation between uptake of FLT and FDG in primary tumor (SUVmax; rho=0.450, p=0.04 / SUV75; rho=0.472, p=0.03). But, TB ratio of FLT-PET was higher than that of FDG-PET($11.7{\pm}7.7\;vs\;6.3{\pm}3.8$, p=0.001). The concordant rate between FLT and FDG uptake of lymph node was reasonably good (33/34). The FLT SUVs of liver and bone marrow were $4.2{\pm}1.2\;and\;8.3{\pm}4.9$. The FDG SUVs of liver and bone marrow were $1.8{\pm}0.4\;and\;1.6{\pm}0.4$. Conclusion: The uptakes of FLT were lower than those of FDG, but all patients of this study revealed good FLT uptakes of tumor and lymph node. Because FLT-PET revealed high TB ratio and concordant rate with lymph node uptakes of FDG-PET, FLT-PET could be a useful diagnostic tool in locally advanced breast cancer. But, physiological uptake and individual variation of FLT in bone marrow and liver will limit the diagnosis of bone and liver metastases.

The National Survey of Acute Respiratory Distress Syndrome in Korea (급성호흡곤란증후군의 전국 실태조사 보고)

  • Scientific Subcommittee for National Survey of Acute Respiratory Distress Syndrome in Korean Academy of Tuberculosis and Respiratory Disease
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.25-43
    • /
    • 1997
  • Introduction : The outcome and incidence of acute respiratory distress syndrome (ARDS) could be variable related to the varied definitions used for ARDS by researchers. The purpose of the national survey was to define the risk factors of ARDS and investigate the prognostic indicies related to mortality of ARDS in Korea according to the definition of ARDS determined by the American-European Concensus Conference on 1992 year. Methods : A Multicenter registry of 48 University or University-affliated hospital and 18 general hospital s equipped with more than 400 patient's beds conducted over 13 months of patients with acute respiratory distress syndrome using the same registry protocol. Results : 1. In the 12 months of the registry, 167 patients were enrolled at the 24 hospitals. 2. The mean age was 56.5 years (${\pm}17.2$ years) and there was a 1.9:1 ratio of males to females. 3. Sepsis was the most common risk factors (78.1%), followed by aspiration (16.6%), trauma (11.6%), and shock (8.5%). 4 The overall mortality rate was 71.9%. The mean duration was 11 days (${\pm}13.1$ days) from the diagnosis of ARDS to the death. Respiratory insufficiency appeared to be a major cause in 43.7% of the deaths followed by sepsis (36.1%), heart failure (7.6%) and hepatic failure (6.7%). 5. There were no significant differences in mortality based on sex or age. No significant difference in mortality in infectious versus noninfectious causes of ARDS was found. 6. There were significant differences in the pulse rate, platelet numbers, serum albumin and glucose levels, the amounts of 24 hour urine, arterial pH, $Pa0_2$, $PaCO_2$, $Sa0_2$, alveolar-arterial oxygen differences, $PaO_2/FIO_2$, and PEEP/$FI0_2$ between the survivors and the deaths on study days 1 through 6 of the first week after enrollment. 7. The survivors had significantly less organ failure and lower APACHE III scores at the time of diagnosis of ARDS (P<0.05). 8. The numbers of organ failure (odd ratio 1.95, 95% confidence intervals:1.05-3.61, P=0.03) and the score of APACHE III (odd ratio 1.59, 95% confidence interval:1.01-2.50, P=0.04) appeared to be independent risk factors of the mortality in the patients with ARDS. Conclusions : The mortality was 71.9% of total 167 patients in this investigation using the definition of American-European Consensus Conference on 1992 year, and the respiratory insufficiency was the leading cause of the death. In addition, the numbers of organ failure and the score of APACHE III at the time of diagnosis of ARDS appeared to be independent risk factors of the mortality in the patients with ARDS.

  • PDF

Activities of the Hydrolytic Enzymes Produced by Plant Pathogenic Fungi, Sclerotium rolfsii, Sclerotinia Sclerotinia and Sclerotiorum, and Helminthosporium sigmoideum var. irregulare (수종의 식물병원균(흰비단병균$\cdot$균핵병균 및 좀검은 균핵병균)이 생산하는 가수분해효소의 활성)

  • Cho B. H.;Kim K.
    • Korean journal of applied entomology
    • /
    • v.16 no.4 s.33
    • /
    • pp.199-208
    • /
    • 1977
  • Activities of various hydrolytic enzymes produced by three plant pathogenic fungi, Sclerotium rolfsii Sacc., Sclerotinia sclerotiorum (Lieb.) deBary and Helminthosporium sigmoideum var. irregulare Crallery et Tullius, were measured. Activties and amounts of the enzymes in mycelia, cultural filtrates, and sclerotia(except of sclerotia of H. sigmoideum var. irregulare) were estimated at various pH levels in order to find out optimal pH for their enzymatic activities. Enzymes such as cellulase (ex), invertase, xylanase, $\beta-amylase$, polymethylgalacturonase, polygalacturonase, phosphatase and protease were estimated. Culture solution for production of enzymes was prepared by adding of 10g, D-glucose, 1.3g $NH_4NO_3,\; 0.5g\; MgSO_4,\;7H_2O,\; and\; 1.0g\; KH_2PO_4$ into 1 liter of potato decoction plus 2ml of micro element solution consisting of 0.2mg. Fe, 0.2mg Zn, and 0.1mg Mn as the sulphates into 1 liter of distilled water. All tested mycelia and cultural filtrates were obtained from the cultures incubarted in previous solution for ten days at $25^{\circ}C$, and sclerotia were harvested from PDA plates of 3. days old, The crude enzyme solutions were prepared according to the method of Miyazaki etal. Ten days after incubation, activities of Cx produced by Scl. sclerotiorum were higher than those of the other fung and each of Cx from three fungi showed different pH optima, such as S. rolfsii and Scl. schlerotiorum in acid side (around pH 3.0), H. sigmoideum var. irregulare in neutral side (around pH 6.3). Invertase activities of S. rolfsii were 20 times higher than those of the other fungi in all samples. All tested fungi, however, showed no significant difference between the enzymatic activities of their cultural filtrate and mycelia and the activities in sclerotia of S. rolfsii and Scl. sclerotiorum were hardly recognized. There were multiple peaks on the xylanase activity curves of three fungi in terms of pH values. High activities of the xylanase were revealed in sclerotia of S. rolfsii and Scl. sclerotiorum, and in mycelia of H. sigmoideum var. irregulare. The highest activities of $\beta-amylase$ were shown both in mycelia and cultural filtrate of H. sigmoideum var. irregulae among the tested fungi, and their optimal pH was 6.2 in both mycelia and cultural filtrate. In the S. rofsii and Sel. sclerotiorum, however, the activities of cultural filtrates were higher than those of the other fungi, and optimal pH was 3.0 and 6.2 for cultural filtrate and both mycelia and sclerotia, respectively. Activities of PMG were high in cultural filtrates of all tested fungi, especially in Scl. sclerotiorum and H. sigmoideum var. irregulare. Mycelia of themalso showed the considerable activities. Optimal pH for enzymatic activities were variable with thekind of fungi or with the samples measured. The highest activities of PG were presented by mycelia of S. rolfsii and Scl. sclerotiorum. $9.l\mu /min.\; and\; 9.5\mu g/min.$, respectively. Optimal pH for activity of PG in mycelia was around 4.5 in S. rolfsii and around 3.0 in Scl. sclerotiorum. Phosphatase of S. rolfsii and Scl. sclerotiorum was more active in acid side (optimal PH3. 5) and that of H. sigmoideum var. irregulare showed one peak each in acid, neutral and alkaline side. But the highest peak was at pH 9.5. Protease of all tested fungi was more active at pH 10.0, especially that of the cultural filtrate of H. sigmoideum var. irregualre.

  • PDF

Anthropometric Measurements and Biochemical Nutritional Status of the Older Residents (50 years and over) in Andong Area (2) (안동주변 농촌지역 50세 이상 주민의 신체계측치 및 생화학적 영양상태에 관한 연구 (2))

  • Lee, Hye-Sang;Kwun, In-Sook;Kwon, Chong-Suk
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.12
    • /
    • pp.1599-1608
    • /
    • 2008
  • This study aimed to assess the health status based on the anthropometric and biochemical measurements of middle-aged and elderly people living in Andong area. The subjects were 1,384 people (532 males, 852 females) aged 50 years and over (average 62.7 years). The mean anthropometric values for males and females were heights of 163.7 and 151.5 cm; weights 63.6 and 57.3 kg; body mass index (BMI) 23.6 and $24.9kg/m^2$; body fat 21.8 and 31.8%, respectively. Height and weight were lower, however, waist circumference (in female) and BMI were higher than those of the 2001 National Health and Nutrition Survey (NHNS). Obesity incidences of male and female subjects were 28.7% and 47.3% by BMI; 25.8% and 50.8% by % body fat; and 15.6% and 80.9% by waist circumference, respectively. Also, abdominal adiposity was very severe in female subjects of 50s. The mean biochemical measurements of male and female were as follows: systolic and diastolic blood pressure 136.9, 83.8 mmHg and 133.6, 82.5 mmHg; hemoglobin (Hb) 14.3 and 13.0 g/dL; hematocrit (Ht) 44.7 and 39.8%; blood albumin 4.15 and 4.04 g/dL; total-cholesterol 170.0 and 183.1 mg/dL; HDL-cholesterol 43.6 and 42.7 mg/dL; fasting blood glucose 96.7 and 93.0 mg/dL, respectively. Also, the prevalence of biochemically abnormal subjects according to each cut-off point of biochemical measurements were analyzed. The results for male and female were; hypertension 58.0% and 47.2%; iron deficient anemia 19.3% and 20.6% by Hb, 7.2% and 11.9% by Ht; hypoalbuminemia 9.8% and 11.7%; diabetes 12.0% and 10.2%; hypercholesterolemia 19.5% and 30.5%, respectively. From those results we found that hypoalbuminemia, hypertension and hypercholesterolemia were prevalent, and obesity in females of 50s, iron-deficient anemia and diabetes in males of 70 years and over were significant health problems in this area. Therefore, it seems to be necessary to examine their health status periodically and provide the appropriate health and nutrition education program, which includes low sodium intake, balanced diet, exercise and weight control, to prevent the occurrence of chronic diseases.