• Title/Summary/Keyword: Globe temperature

Search Result 119, Processing Time 0.029 seconds

Global Fate of Persistent Organic Pollutants: Multimedia Environmental Modelling and Model Improvement (잔류성 유기오염물질의 전 지구적 거동: 다매체 환경모델의 결과해석 및 개선방안)

  • Choi, Sung-Deuk;Chang, Yoon-Seok
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.12 no.1
    • /
    • pp.24-31
    • /
    • 2007
  • Global fates of polychlorinated biphenyl(PCB) were investigated with a fugacity based multimedia transport and fate model, Globe-POP(persistent organic pollutant). The accumulation of PCB was directly affected by the emission patterns of PCB into the atmosphere and surface areas of environmental compartments. Partition coefficients and reaction rates also influenced on the accumulation patterns of PCB. The emission patterns of PCB in 10 climate zones were consistent for the past 70 years, while the contribution of PCB in high-latitude zones to the globe has increased by cold condensation. Considering the amounts of emission and accumulation of PCB, the North temperature zone is regarded as an important source and sink of PCB. Meanwhile, in spite of no significant sources, POPs accumulate in Antarctic environments mainly due to extremely low temperature. Finally we suggested that a global water balance accounting for snow/ice should be incorporated into multimedia environmental models for high-latitude zones and polar regions with the seasonal snow pack and/or permanent ice caps. The modified model will be useful to evaluate the influence of climate change on the fate of POPs.

Development of the Best Spherical Interpolation Method for Estimating Potential Natural Vegetation Distribution of the Globe (지구(地球)의 잠재자연식생분포(潜在自然植生分布)를 추정(推定)하기 위한 최적구면보간법(最適球面補間法)의 개발(開發))

  • Cha, Gyung Soo;Ochiai, Kamiya
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.1
    • /
    • pp.17-24
    • /
    • 1997
  • As the first step to estimate the potential natural vegetation distribution of the globe, the best spherical interpolation method was developed to the temperature and precipitation which have close relation to the distribution pattern of world natural vegetation. For developing the interpolation method, a named Light Climatic Dataset composed of 1,060 stations around the globe was randomly divided into halves of feeding side and target side. The discrepancy between the observed and estimated values at the target stations was compared with combinations of parameters and methods. The estimated values were calculated to each combination which is all-out, constant radius and constant station methods in the selection of the feeding stations, n square reciprocal and negative exponential functions in weighting function of distance between feeding stations and each target, and oval weighting in direction of the feeding stations from each target. As a result, it turned out that the spherical interpolation with negative exponential weighting function fed from the constant radius stations ovally weighed yields the best estimates both for temperature and for precipitation. The parameters for temperature are $30^{\circ}$ in constant radius, 0.78 in negative exponential function and 0.4 in oval weighting, and for precipitation are $30^{\circ}$, 0.53 and 0.4, respectively.

  • PDF

An Analysis of Thermal Comforts for Pedestrians by WBGT Measurement on the Urban Street Greens (도심 가로 녹음의 습구흑구온도(WBGT) 측정을 통한 보행자 열쾌적성 효과 분석)

  • Ahn, Tong-Mahn;Lee, Jae-Won;Kim, Bo-Ram;Yoon, Ho-Seon;Son, Seung-Woo;Choi, Yoo;Lee, Na-Rae;Lee, Ji-Young;Kim, Hae-Ryung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.3
    • /
    • pp.22-30
    • /
    • 2013
  • This study aims to measure the thermal comfort effects of urban street trees. As the usual dry bulb air temperature does not indicate properly how the average pedestrian feels the heat of a typical summer day under the strong sunshine, we adopted the Wet Bulb Globe Temperature(WBGT). WBGT involves black globe temperature to measure the direct radiation of sun beams on our bodies, for example our heads. We measured temperatures on very sunny and hot summer days, August 3, 4, and 7, 2012, on the urban streets of Seoul, Korea. Wet bulb, globe, and dry bulb temperatures were measured under direct sunlight from 1 O'clock to 5 O'clock pm. Globe and dry bulb temperatures were measured under street tree shades nearby during the same hours. Then the WBGTs were calculated with the formulae, one for sunny outdoor spaces, and the other for shaded outdoor spaces or indoor. The results are compared with the Korean Standards Association(KS A ISO 7243). The major findings were: 1) On very sunny and hot summer days in Seoul, street tree shades lower the WBGT about 1 to 4 degrees, 2) during the hours of 3 and 4 O'clock in the afternoon, the WBGT under the tree shades are about 3 to 4 degrees lower compared to those under sunshines(approx. 29 to 32 degrees respectively), 3) This difference makes a major thermal comfort for urban pedestrians because senior citizens or weak persons are recommended to move indoor, and even healthy people are recommended stop outdoor sports and take rests in the shades when WBGT is about 32. On the other hand, if the WBGT is around 29, or 3 degrees lower, slower walking, light works or sports are allowable, 4) On site questionnaire survey confirms the thermal comforts under the tree shades, and we even could not get survey subjects on the sunny parts of the sidewalks, 5) We strongly recommend change of guidelines for urban street trees from "one row of street trees on 6m~8m intervals" to "street trees to make continuous shades".

New Approach to Air Quality Management (대기오염관리의 새로운 접근방법)

  • 윤명조
    • Journal of environmental and Sanitary engineering
    • /
    • v.8 no.2
    • /
    • pp.25-48
    • /
    • 1993
  • International concern over the environmental pollution is ever increasing, and diversified countermeasures must be devised in Korea also. Global trend, damages, problems and countermeasures with respect to issues mentioned in the Rio Declaration, such as prevention of ozone layer destruction, reduction of migratory atmospheric pollution between neighboring countries, and prevention of global greenhouse effect, were discussed in this report. Conclusion of the report is summarized as follows : A. Measurement, Planning and Monitoring (1) Development and implementation of a global network for measurement and monitoring from the global aspects such factors as related to acid rain(Pioneer substances, pH, sulfate, nitrate), effect of global temperature(Air temperature, $CO_2$, $CH_4$, CFC, $N_2O$) and destruction of ozone layer($CFC_S$). (2) Establishment of network system via satellite monitoring movement of regional air mass, damage on the ozone layer and ground temperature distribution. B. Elucidation of Present State (1) Improvement and development of devices for carbon circulation capable of accurately forecasting input and output of carbon. (2) Developmental research on chemical reactions of greenhouse gas in the air. (3) Improvement and development of global circulation model(GCM) C. Impact Assessment Impact assessment on ecosystem, human body, agriculture, floodgate, land use, coastal ecology, industries, etc. D. Preventive Measures and Technology Development (1) Development and consumption of new energy (2) Development of new technology for removal of pioneer substances (3) Development of substitute matter for $CFC_S$ (4) Improvement of agriculture and forestry means to prevent the destruction of ozone layer and the greenhouse effect of the globe (5) Improvement of housing to prevent the destruction of ozone layer and the greenhouse effect of the globe (6) Development of new technology for probing underground water (7) Preservation of forest (8) Biomass 5. Policy Development (1) Development of strategy model (2) Development of long term forecast model (3) Development of penalty charge effect and expense evaluation methods (4) Feasibility study on regulations By establishing the above mentioned measures for environmentally sound and sustainable development to establish the right to live for humankind and to preserve the one and only earth.

  • PDF

Relationship between Low-level Clouds and Large-scale Environmental Conditions around the Globe

  • Sungsu Park;Chanwoo Song;Daeok Youn
    • Journal of the Korean earth science society
    • /
    • v.43 no.6
    • /
    • pp.712-736
    • /
    • 2022
  • To understand the characteristics of low-level clouds (CLs), environmental variables are composited on each CL using individual surface observations and six-hourly upper-air meteorologies around the globe. Individual CLs has its own distinct environmental conditions. Over the eastern subtropical and western North Pacific Ocean in JJA, stratocumulus (CL5) has a colder sea surface temperature (SST), stronger and lower inversion, and more low-level cloud amount (LCA) than the climatology whereas cumulus (CL12) has the opposite characteristics. Over the eastern subtropical Pacific, CL5 and CL12 are influenced by cold and warm advection within the PBL, respectively but have similar cold advection over the western North Pacific. This indicates that the fundamental physical process distinguishing CL5 and CL12 is not the horizontal temperature advection but the interaction with the underlying sea surface, i.e., the deepening-decoupling of PBL and the positive feedback between shortwave radiation and SST. Over the western North Pacific during JJA, sky-obscuring fog (CL11), no low-level cloud (CL0), and fair weather stratus (CL6) are associated with anomalous warm advection, surface-based inversion, mean upward flow, and moist mid-troposphere with the strongest anomalies for CL11 followed by CL0. Over the western North Pacific during DJF, bad weather stratus (CL7) occurs in the warm front of the extratropical cyclone with anomalous upward flow while cumulonimbus (CL39) occurs on the rear side of the cold front with anomalous downward flow. Over the tropical oceans, CL7 has strong positive (negative) anomalies of temperature in the upper troposphere (PBL), relative humidity, and surface wind speed in association with the mesoscale convective system while CL12 has the opposite anomalies and CL39 is in between.

The Burdens of Occupational Heat Exposure-related Symptoms and Contributing Factors Among Workers in Sugarcane Factories in Ethiopia: Heat Stress Wet Bulb Globe Temperature Meter

  • Mitiku B. Debela;Achenef M. Begosaw;Negussie Deyessa;Muluken Azage
    • Safety and Health at Work
    • /
    • v.14 no.3
    • /
    • pp.325-331
    • /
    • 2023
  • Background: Heat stress is a harmful physical hazard in many occupational settings. However, consequences of occupational heat exposure among workers in a sugarcane factory in Ethiopia are not well characterized. This study aimed to assess the level of occupational heat exposure-related symptoms and contributing factors. Methods: In this cross-sectional study, five workstations were selected for temperature measurement. Heat stress levels were measured using a wet-bulb globe temperature index meter. A stratified random sampling technique was used to select 1,524 participants. Heat-related symptoms were assessed using validated questionnaires. Results: The level of occupational heat exposure was 72.4% (95% CI: 70.2%-74.8%), while 71.6% (95% CI: 69.3%-74.9%) of participants experienced at least one symptom related to heat stress. The most common heat-related symptoms were swelling of hands and feet (78%), severe thirst (77.8%) and dry mouth (77.4%). The identified risk factors were a lack of reflective shields (AOR: 2.20, 95% CI: 1.53, 3.17), not-enclosed extreme heat sources (AOR: 1.76, 95% CI: 1.23, 2.51), a lack of access to shade (AOR: 9.62, 95% CI: 6.20, 14.92), and inappropriate protective clothing provision (AOR: 1.58, 95% CI: 1.27, 2.71). Conclusions: The burden of occupational heat exposure and heat-induced symptoms was high. Lack of reflective shields, the absence of enclosed extreme heat sources, a lack of access to shade, and inappropriate protective clothing provision were considerable attributes of heat stress. Therefore, the use of mechanical solutions to stop heat emissions at their sources and the key factors identified were areas for future intervention.

Evaluation of Passive Cooling Effect on Roof Pond through Field Observation (관측에 의한 옥상 수공간의 자연냉각효과 평가)

  • Jeong, Seong-Jin;Choi, Dong-Ho;Lee, Bu-Yong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.85-89
    • /
    • 2008
  • This study carried out field observations of measuring thermal environment, especially evaluating amount of water evaporation at roof Pond by field observations during the summer. Thermal environment measuring was categorized as air temperature, water temperature of roof pond, surface temperature, globe temperature, short and long wave radiation, net radiation, and amount of water evaporation by water level measurement. Results from this study could be used as fundamental for reducing heat Island phenomena.

  • PDF

A Study on the Indoor Thermal Environment of House Using Earth Brick Wall (황토벽돌벽 주택의 실내온열환경에 관한 연구)

  • 이재윤
    • Journal of the Korean housing association
    • /
    • v.15 no.1
    • /
    • pp.25-32
    • /
    • 2004
  • The purpose of this study is to understand the indoor thermal environment in the earth brick wall building what is called a ecological Architecture. To investigate thermal performances of the earth brick walls, it measured indoor and outdoor air temperature, relative humidity, globe temperature and PMV in reference house. The result of this study were summarized as the followings; 1) When the outdoor average air temperature was $21.8^{\circ}$, livingroom was $24.9^{\circ}$, kitchen was $25.1^{\circ}$ and 2nd floor room was $25.6^{\circ}$ at 150 cm height from the floor. 2) Although the average outdoor relative humidity was 78%, the livingroom was 67.5%. 3) As the air temperature difference between at the top and bottom was $0.6^{\circ}$ in living room, this value was below 1 % of PPD by ASHRAE Handbook. 4) Predicted Mean Vote(PMV) by ISO-7730 was +0.41.

Trends in the Climate Change of Surface Temperature using Structural Time Series Model (구조적 시계열 모형을 이용한 기온 자료에 대한 기후변화 추세 분석)

  • Lee, Jeong-Hyeong;Sohn, Keon-Tae
    • Atmosphere
    • /
    • v.18 no.3
    • /
    • pp.199-206
    • /
    • 2008
  • This study employs a structural time series method in order to model and estimate stochastic trend of surface temperatures of the globe, Northern Hemisphere, and Northeast Asia ($20^{\circ}N{\sim}60^{\circ}N$, $100^{\circ}E{\sim}150^{\circ}E$). For this study the reanalysis data CRUTEM3 (CRU/Hadley Centre gridded land-surface air temperature Version 3) is used. The results show that in these three regions range from $0.268^{\circ}C$ to $0.336^{\circ}C$ in 1997, whereas these vary from $0.423^{\circ}C$ to $0.583^{\circ}C$ in 2007. The annual mean temperature over Northeast Asia has increased by $0.031^{\circ}C$ in 2007 compared to 1997. The climate change in surface temperatures over Northeast Asia is slightly higher than that over the Northern Hemisphere.

Thermal Environment of Small-size Apartments Facing in Two Different Directions (소형아파트의 방위에 따른 실내온열환경 실태와 평가)

  • 최윤정
    • Journal of the Korean Home Economics Association
    • /
    • v.31 no.3
    • /
    • pp.213-222
    • /
    • 1993
  • The purpose of this study was to investigate the present conditions of thermal environment in small-size apartments. The research methods used were measuring of environmental elements and personal self-administration for the residents' thermal comfort responses. The house subjected were 25 peung apartments facing southeast and southwest directions. The results of this study were summarized as follow ; The indoor temperature and humidity of houses subjected were 25.0∼27.3℃, 37.1∼42.5%. Compared with the distribution of indoor temperature and globe temperature of houses subjected, those of southeast house were more stable. And in the residents' thermal sensation responses, the residents of southeast houses checked more often neutral zone. Therefore the thermal environment of southeast houses were more comfortable condition than southwest houses.

  • PDF