• Title/Summary/Keyword: Gleason Standard

Search Result 8, Processing Time 0.02 seconds

Development of Rating Systems for Power Transmission Bevel Gears (동력전달용 베벨기어의 강도평가 시스템 개발 연구)

  • Chong, T.H.;Chi, J.J.;Byun, J.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.7
    • /
    • pp.66-73
    • /
    • 1995
  • Rating systems of bevel gears(straight, spiral, and zerol bevel gears) which are commonly used as power transmission devices for non-papallel axes are developed on the personal computer, which analyze and/or evaluate the gear design and the service performance at the point of view of strength and durability. The typical considerations of the ratings are the bending strength, the surface durability, and the scoring resistance. The ratings are carried out using the reliable standards of AGMA & Gleason Works. Therefore, the system is built so that the variables or factors considered differently in those standards and the strength, dura- bility, and scoring partially in Gleason are appraised seperately by each method, and a series of the estimation processes is integrated into the system so as to compare each result. The developed rating systems can be used in the initial stage of gear design process, and also a better design can be performed by the evaluation of the initial design at the view point of gear strength and durability. Additionally, it is useful for the trouble-shooting of bevel gear system and to the purpose of introducing the methods for maintaining design strength in service, with appraising the gear strength after design or with appraising the influencing factor as a whole. Therefore, this rating systems can help the aim of design automation of bevel gears.

  • PDF

A Curvic-Coupling Development for the Turbopump Application (터보펌프용 커빅커플링의 개발)

  • Jeong, Eun-Hwan;Yoon, Suk-Hwan;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.22-25
    • /
    • 2009
  • Development of a curvic-coupling was presented in this paper. The research covers design, structural analysis, hot-temperature-torsion-test, curvic-coupling applied proto-type turbine disk manufacturing, and assembly test of a curvic-coupling rotor system for the turbopump application. Curvic-coupling was designed based on the Gleason-standard-tooth shape. The load capability of the designed curvic coupling was validated by the structural analysis and hot-temperature-torsion-test. A proto-type turbine disk which had adopted designed curvic-coupling was manufactured, assembled and tested to reveal that shaft-disk assembly run-outs in axial and radial directions were much smaller than the design requirements. The development will be finalized after spin test of shaft-disk assembly in near future.

  • PDF

Comparison of the Walz Nomogram and Presence of Secondary Circulating Prostate Cells for Predicting Early Biochemical Failure after Radical Prostatectomy for Prostate Cancer in Chilean Men

  • Murray, Nigel P;Reyes, Eduardo;Orellana, Nelson;Fuentealba, Cynthia;Jacob, Omar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.16
    • /
    • pp.7123-7127
    • /
    • 2015
  • Purpose: To determine the utility of secondary circulating prostate cells for predicting early biochemical failure after radical prostatectomy for prostate cancer and compare the results with the Walz nomagram. Materials and Methods: A single centre, prospective study of men with prostate cancer treated with radical prostatectomy between 2004 and 2014 was conducted, with registration of clinical-pathological details, total serum PSA pre-surgery, Gleason score, extracapsular extension, positive surgical margins, infiltration of lymph nodes, seminal vesicles and pathological stage. Secondary circulating prostate cells were obtained using differential gel centrifugation and assessed using standard immunocytochemistry with anti-PSA. Biochemical failure was defined as a PSA >0.2ng/ml, predictive values werecalculated using the Walz nomagram and CPC detection. Results: A total of 326 men participated, with a median follow up of 5 years; 64 had biochemical failure within two years. Extracapsular extension, positive surgical margins, pathological stage, Gleason score ${\geq}8$, infiltration of seminal vesicles and lymph nodes were all associated with higher risk of biochemical failure. The discriminative value for the nomogram and circulating prostate cells was high (AUC >0.80), predictive values were higher for circulating prostate cell detection, with a negative predictive value of 99%, sensitivity of 96% and specificity of 75%. Conclusions: The nomagram had good predictive power to identify men with a high risk of biochemical failure within two years. The presence of circulating prostate cells had the same predictive power, with a higher sensitivity and negative predictive value. The presence of secondary circulating prostate cells identifies a group of men with a high risk of early biochemical failure. Those negative for secondary CPCs have a very low risk of early biochemical failure.

Development of a S/W calculating design parameters automatically for bevel gears (베벨기어의 설계 및 해석을 위한 PC용 형상제원 산출 S/W 개발)

  • 유우식
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.21 no.47
    • /
    • pp.181-191
    • /
    • 1998
  • Bevel gears are suitable for transmitting power between shafts at practically any angle or speed. However, the particular type of gear best suited for a specific application is depends upon the mountings, available space, and operating conditions. Therefore it is important in any general design imploying gears to first make a study of all the conditions under which the gear must operate. Presented in this paper is a S/W calculating design parameters automatically for bevel gears. This S/W provides the Standards for the design of straight bevel, zerol bevel, spiral bevel and hypoid gears. Topics include preliminary design parameters, blank design including standard taper, uniform depth, duplex taper and tilted root so that Gleason, Klingelnberg and Oerlikon machine tools are covered.

  • PDF

The Diagnostic Performance of the Length of Tumor Capsular Contact on MRI for Detecting Prostate Cancer Extraprostatic Extension: A Systematic Review and Meta-Analysis

  • Tae-Hyung Kim;Sungmin Woo;Sangwon Han;Chong Hyun Suh;Soleen Ghafoor;Hedvig Hricak;Hebert Alberto Vargas
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.684-694
    • /
    • 2020
  • Objective: The purpose was to review the diagnostic performance of the length of tumor capsular contact (LCC) on magnetic resonance imaging (MRI) for detecting prostate cancer extraprostatic extension (EPE). Materials and Methods: PubMed and EMBASE databases were searched up to March 24, 2019. We included diagnostic accuracy studies that evaluated LCC on MRI for EPE detection using radical prostatectomy specimen histopathology as the reference standard. Quality of studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity were pooled and graphically presented using hierarchical summary receiver operating characteristic (HSROC) plots. Meta-regression and subgroup analyses were conducted to explore heterogeneity. Results: Thirteen articles with 2136 patients were included. Study quality was generally good. Summary sensitivity and specificity were 0.79 (95% confidence interval [CI] 0.73-0.83) and 0.67 (95% CI 0.60-0.74), respectively. Area under the HSROC was 0.81 (95% CI 0.77-0.84). Substantial heterogeneity was present among the included studies according to Cochran's Q-test (p < 0.01) and Higgins I2 (62% and 86% for sensitivity and specificity, respectively). In terms of heterogeneity, measurement method (curvilinear vs. linear), prevalence of Gleason score ≥ 7, MRI readers' experience, and endorectal coils were significant factors (p ≤ 0.01), whereas method to determine the LCC threshold, cutoff value, magnet strength, and publication year were not (p = 0.14-0.93). Diagnostic test accuracy estimates were comparable across all assessed MRI sequences. Conclusion: Greater LCC on MRI is associated with a higher probability of prostate cancer EPE. Due to heterogeneity among the studies, further investigation is needed to establish the optimal cutoff value for each clinical setting.

Reduced Port Surgery for Prostate Cancer is Feasible: Comparative Study of 2-port Laparoendoscopic and Conventional 5-port Laparoscopic Radical Prostatectomy

  • Akita, Hidetoshi;Nakane, Akihiro;Ando, Ryosuke;Yamada, Kenji;Kobayashi, Takahiro;Okamura, Takehiko;Kohri, Kejiro
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6311-6314
    • /
    • 2013
  • Background: While 5-port laparoendoscopic radical prostatectomy is standard practice, efforts have been focused in developing a single port surgery for cosmetic reasons. However, this is still in the pioneering stage considering the challenging nature of the surgical procedures. We have therefore focused on reduced port surgery, using only 2-ports. In this study, we compared 2-port laparoendoscopic radical prostatectomy (2-port RP) and conventional 5-port laparoscopic radical prostatectomy (LRP) for clinically localized prostate carcinoma and evaluated the potential advantages of each. Materials and Methods: From January 2010 to December 2010, all 23 patients with clinically localized prostate cancer underwent LRP. Starting November, 2010, when we introduced the reduced port approach, we performed this procedure for 22 consecutive patients diagnosed with early-stage prostate cancer (cT1c, cT2N0). The patients were matched 1:1 to 2-port RP or LRP for age, preoperative serum PSA level, clinical stage, biopsy and pathological Gleason grade, surgical margin status, pad-free rates and post-operative pain. Results: There was a significant difference in operative time between the 2-port RP and LRP groups ($286.5{\pm}63.3$ and $351.8{\pm}72.4$ min: p=0.0019, without any variation in blood loss (including urine) ($945.1{\pm}479.6$ vs $1271.1{\pm}871.8ml$: p=0.13). The Foley catheter indwelling period was shorter in the 2 port RP group, but without significance ($5.6{\pm}1.8$ vs $8.0{\pm}5.6$ days: p=0.057) and the total perioperative complication rates for 2 port RP and LRP were comparable at 4.5% and 8.7% (p=0.58). There was an improvement in pad-free rates up to 6 months follow-up (p=0.090), and significantly improvement at 1 year (p=0.040). PSA recurrence was 1 (4.5%) in 2-port RP and 2 (8.7%) in LRP. Continuous epidural anesthesia was used in most of LRP patients (95.7%) and in early 2-port RP patients (40.9%). In these patients, average total amount of Diclofenac sodium was 27.8mg/patient in 2-port RP and 50.0mg/patient in LRP. Conclusions: Thus the reduced port approach is as efficacious as LRP in terms of many outcome measures, with significant cosmetic advantages and reduction in post surgical pain. This method can be readily performed safely and therefore can be recommended as a standard laparoscopic surgery for prostate cancer in the future.

Comparison of Computed Diffusion-Weighted Imaging b2000 and Acquired Diffusion-Weighted Imaging b2000 for Detection of Prostate Cancer (전립선암 발견을 위한 계산형 확산강조영상 b2000과 실제 획득한 b2000 영상의 비교)

  • Yeon Jung Kim;Seung Ho Kim;Tae Wook Baek;Hyungin Park;Yun-jung Lim;Hyun Kyung Jung;Joo Yeon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.5
    • /
    • pp.1059-1070
    • /
    • 2022
  • Purpose To compare the sensitivity of tumor detection and inter-observer agreement between acquired diffusion-weighted imaging (aDWI) b2000 and computed DWI (cDWI) b2000 in patients with prostate cancer (PCa). Materials and Methods Eighty-eight patients diagnosed with PCa by radical prostatectomy and having undergone pre-operative 3 Tesla-MRI, including DWI (b, 0, 100, 1000, 2000 s/mm2), were included in the study. cDWI b2000 was obtained from aDWI b0, b100, and b1000. Two independent reviewers performed a review of the aDWI b2000 and cDWI b2000 images in random order at 4-week intervals. A region of interest was drawn for the largest tumor on each dataset, and a Prostate Imaging-Reporting and Data System (PI-RADS) score based on PI-RADS v2.1 was recorded. Histologic topographic maps served as the reference standard. Results The study population's Gleason scores were 6 (n = 16), 7 (n = 53), 8 (n = 9), and 9 (n = 10). According to the reviewers, the sensitivities of cDWI b2000 and aDWI b2000 showed no significant differences (for reviewer 1, both 94% [83/88]; for reviewer 2, both 90% [79/88]; p = 1.000, respectively). The kappa values of cDWI b2000 and aDWI b2000 for the PI-RADS score were 0.422 (95% confidence interval [CI], 0.240-0.603) and 0.495 (95% CI, 0.308-0.683), respectively. Conclusion cDWI b2000 showed comparable sensitivity with aDWI b2000, in addition to sustained moderate inter-observer agreement, in the detection of PCa.

Ecological Studies on Several Forest Communities in Kwangnung. A Study of the Site Index and the ground vegetation of Larch (광릉삼림의 생태학적 연구 낙엽송의 Site Index와 임상식생에 관하여)

  • 차종환
    • Journal of Plant Biology
    • /
    • v.9 no.1_2
    • /
    • pp.7-16
    • /
    • 1966
  • In order to determine the factors related to site quality, 13 areas of Larch growing in the Kwangung and its vicinity forest as sample plots, were examined. Sample plots included various site classes as well as age classes. Three were divided into two groups (major and minor trees). Average height of dominant trees was determined through messurement of 5 to 6 dominant tree in each sample plots. Average height of dominant 30 year-old trees was the basis for site index. A Standard Yield Table for the larch produced in Kwangnung forest was made by various data, which included age class 5, ranging from 10 to 45 years. The relationship of the height of the trees, the site conditions, and ground vegetation are investigated in this paper. The site indexes of 40 forest class age in 28-B and 28-G forest classes of the larch associations for ground vegetation had comparatively rarge differences due to the sampled areas. The relation of the direction of forest communities to the height and the diameter of the tree shwoed that its communiteis of northest and northwest parts appeared higher valueof the height and the diameter. The diameter and the height of trees were closely realted to each other. The samller the occupied area per tree and the smaller the average distance among trees, the more density was increased. The larger the density was the lower height of the trees. In the ground vegetation of the larch communities, there seems to be a definite correlation between the height of trees and the occupied area per tree or the average distance among the trees. The height of trees and site index of two larch communities were as follow: 28-B forest class site index 20.8, height 24.0m, 28-G forest class site index 18.4, height 20.9m. The ground layer was analyzed by the method of Quadrat(20/20sq. cm) with an interval of 1M. It set up 40 Quadrats of the larch communiteis. The community structure of the ground vegetation of two larch was analyzed, and important value was calculated and then evaluated. The ground vegetation under the larch had developed Burmannii Beauv stratal society below the 28-B and 28-G the forest class. Accordingly, the first important value of Burmannii Beauv was found in two ground vegetation below the larch. Therefore, this species could be quantitatively considered as the forest indicator species. Common species of each community appeared 18 species out of 34 species in the ground vegetation under two larch communities. The ground vegetation of the 28-B forest class showed more than that of the 28-G forest class. the similarity of the ground vegetation was measrued by the Frequency Index Community Coefficient. The differences between the associations were lcearly manifested by the ground vegetation tested by Gleason's Frequency Index of Community Coefficient for the analysis of each stratal society of all associations. According to F.I.C.C. the ground vegetation under two larch(28-B and 28-G) forest classes showed higher value. An investigation into the relationship of physical and chemical properties of soil and site was considered the next step to be taken in the study of the larch site classification.

  • PDF