• Title/Summary/Keyword: Glass transfer robot

Search Result 8, Processing Time 0.019 seconds

Analysis of Chattering Problem of a Glass Transfer Robot Hand (글래스 반송용 로봇핸드의 채터링 원인 해석)

  • Kim Joo-Yong;Kang Chul-Goo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.2
    • /
    • pp.98-104
    • /
    • 2005
  • A glass transfer robot is used for handling LCDs in the production line of flat panel displays under clean environments. During glass transfer operations of the robot, chattering phenomenon occurs at the robot hand. This deteriorates the accuracy and repeatability of the end-effector of the robot. In this paper, we present the kinematic solution of the robot and then analyze the cause of this chattering phenomenon in view of the mechanism and servo control and propose a practical solution that can reduce the chattering significantly at the robot hand of the glass transfer robot.

Method of Reducing Residual Vibration at the LCD Transfer Robot (디스플레이 반송로봇 잔류진동 저감방안)

  • Moon, Sung Bae;Rim, Kyung-Hwa
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.2
    • /
    • pp.98-105
    • /
    • 2017
  • In the display industry, the residual vibration of the transfer robot can increase the process time and cause the breakage of the glass substrate, which is critical to productivity of display manufacturing. In this paper, the natural frequencies of transfer robot are analyzed by finite element method. On the basis of the analyzed data, we investigated the response characteristics of input shaping control with or without the glass presence on the hand of the transfer robot using MATLAB program, and compared with the current response characteristics of input shaping control applied to the industry. Based on this, we suggest an optimal residual vibration control method for the practical application in display industry.

  • PDF

Axiomatic Design of Composite Double Arm Type Robot Hands and Wrists for Handling Large Glass Panel Displays (공리 설계를 적용한 대형 평판 디스플레이용 더블암형 복합재료 로봇 핸드 및 리스트)

  • 이창섭;이대길;최진경
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.241-244
    • /
    • 2002
  • Recently, the size of glass panel is increased to $1250 mm{\times}1100 mm{\times}0.7 mm$, whose mass is 2.65 kg, which requires much stiffer robot structure. In addition to the high stiffness, the robot hands and wrists for glass panel handling should have miller surface finishing of its outer surface to prevent particles and dusts from adhering on the surface. The maximum height of the robot structure should not be larger than 1500 mm because other automated guided vehicles (AGV) and transfer equipments have been designed within this size limit. The difference of maximum deflections of the four ends of the hands before and after loading the glass panel should be less than 2.0 mm. In this work, the robot hands and wrists for handling large glass panel displays were designed based on the axiomatic design using the finite element method along with optimization routine.

  • PDF

Full Duplex Robot System for Transferring Flat Panel Display Glass (디스플레이용 판유리 이송을 위한 양방향 이송 로봇장치)

  • Lee, Dong Hun;Lee, Chibum;Kim, Sung Dong;Cho, Young Hak
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.6
    • /
    • pp.996-1002
    • /
    • 2013
  • This study addresses the development of a full duplex robotic system for transferring flat-panel display glass. We propose to accomplish this using a bidirectional linear transfer mechanism in place of the conventional rotary transfer mechanism. The developed full duplex robot comprises a driving part that carries the glass panel laterally, vertical part that can be moved up and down by means of a ball screw and linear motion guide arrangement, and hand part that slides by the cylinder of the driving part along the guide rail with a V-guide bearing attached to the bottom of the support. In addition, an alignment part prevents the hand part from derailing and holds the hand part while the driving part moves horizontally. The full duplex robot lifts and drives a glass panel directly while transferring it to the buffer and does not require rotational motion. Therefore, both transferring and stacking are realized with a single device. This device can be used in existing industrial facilities as an alternative to existing industrial robots in current as well as future process lines. The proposed full duplex robot is expected to save considerable amounts of time and space, and increase product throughput.

Optimization for the Natural Frequency of the TFT-LCD Glass Plate with Multi-Support Point (다점지지된 TFT-LCD 유리기판의 고유진동수 최적화)

  • Lee, H.S.;Lee, Y.S.;Kim, H.S.;Lee, J.W.;Lee, S.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.246-249
    • /
    • 2005
  • The TFT-LCD is extensively used from a small watch to a large TV display, and the demand is increasing rapidly. The size of R-LCD glass plate becomes more bigger, and the thickness become more thinner with high demands. As a result natural frequency of the TFT-LCD glass plate becomes more lower. The TFT-LCD glass plate will be moved by robot arm and may receive effect of vibration that occur at transfer. Natural frequency of the TFT-LCD glass plate is increased or decrease according to location that robot arm fixs glass plate. Purpose of a this study is finding support location that optimize the first natural frequency of TFT-LCD glass plate. The size optimization method of ANSYS 8.0 is used as the optimization tool search on the optimal support location of TFT-LCD glass plate. The considered number of support point is from 4 to 9.

  • PDF

Six Sigma Robust Design of Composite Hand for LCD Glass Transfer Robot (LCD 유리 이송용 복합재료 로봇 핸드의 식스 시그마 강건설계)

  • Nam Hyunwook
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.3 s.234
    • /
    • pp.455-461
    • /
    • 2005
  • This research studied robust design of composite hand for LTR (LCD glass Transfer Robot). $1^{st}$ DOE (Design of Experiment) was conducted to find out vital few Xs. 108 experiments were performed and their results were statistically analyzed. Pareto chart analysis shows that the geometric parameters (height and width of composite beam) are more important than material parameters $(E_{1},\;E_{2})$ or stacking sequence angle. Also, the stacking sequence of mid-layer is more important than that of outer-layer. The main effect plots shows that the maximum deflection of LTR hand is minimized with increasing height, width of beam and layer thickness. $2^{nd}$ DOE was conducted to obtain RSM (Response Surface Method) equation. 25 experiments were conducted. The CCD (Central Composite Design) technique with four factors was used. The coefficient of determination $(R^{2})$ for the calculated RSM equation was 0.989. Optimum design was conducted using the RSM equation. Multi-island genetic algorithm was used to optimum design. Optimum values for beam height, beam width, layer thickness and beam length were 24.9mm, 186.6mnL 0.15mm and 2402.4mm respectively. An approximate value of 0.77mm in deflection was expected to be a maximum under the optimum conditions. Six sigma robust design was conducted to find out guideline for control range of design parameter. To acquire six sigma level reliability, the standard deviation of design parameter should be con trolled within $2{\%}$ of average design value

Condition Monitoring of an LCD Glass Transfer Robot Based on Wavelet Packet Transform and Artificial Neural Network for Abnormal Sound (LCD 라인의 음향 특성신호에 웨이브렛 변환과 인경신경망회로를 적용한 공정로봇의 건정성 감시 연구)

  • Kim, Eui-Youl;Lee, Sang-Kwon;Jang, Ji-Uk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.7
    • /
    • pp.813-822
    • /
    • 2012
  • Abnormal operating sounds radiated from a moving transfer robot in LCD (liquid crystal display) product lines have been used for the fault detection line of a robot instead of other source signals such as vibrations, acoustic emissions, and electrical signals. Its advantage as a source signal makes it possible to monitor the status of multiple faults by using only a microphone, despite a relatively low sensitivity. The wavelet packet transform for feature extraction and the artificial neural network for fault classification are employed. It can be observed that the abnormal operating sound is sufficiently useful as a source signal for the fault diagnosis of mechanical components as well as other source signals.

Flat Panel Display Deflection Analysis Considering Lift Force in Non-Contact Flat Panel Display Conveyer System (비접촉 평판 디스플레이 이송장치에서 양력을 고려한 평판 디스플레이의 처짐 해석)

  • Hwang, Sung-Hyen;Choi, Hyeon-Chang;Lho, Te-Jung;Son, Te-Yong;Park, Bum-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.5
    • /
    • pp.451-457
    • /
    • 2008
  • Flat Panel Display(FPD) is widely used a video display terminals to consumer products of LCD and PDP. The contamination and damage were affected by using the previous contact conveyor's method. In this paper, it analyzes the FPD deflection to develop the non-contact FPD transfer process using lift force. Each conveyor's equipment is called a horizontal conveyor, vertical conveyor and robot pick-up equipment. As result of an analysis of FPD panel's deflection, a robot pick-up equipment has performed according to under the present conditions like panel's weight and loaded glass to move FPD panel from one place to other places properly. Results of the analysis showed 0.474 mm, 0.424 mm and 1.237 mm. Those values are lower than a predicted optimum values : 2 mm for both horizontal and vertical conveyers; 5 mm for robot pick-up equipment. Therefore, those results verify each equipment have safety and reliability.