• Title/Summary/Keyword: Glass strengthening

Search Result 135, Processing Time 0.023 seconds

A Study on the Shear Strengthening Effect of Reinforced Concrete Beams with Structural Damage (구조적 손상을 입은 철근콘크리트 보의 전단보강 효과에 관한 연구)

  • Shin, Yong-Seok;Kim, Jeong-Hoon;Kim, Jeong-Sup;Kim, Kwang-Seok;Cho, Cheol-Hee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.5
    • /
    • pp.43-51
    • /
    • 2008
  • This study examines shear capacity performance and structural characteristics of reinforced concrete beam using carbon fiber sheet(CFS), g)ass fiber sheet(GFS), glass fiber steel plate(GSP) and carbon fiber bar CB) which are reinforcing materials for reinforced concrete beam in order to produce similar condition to repair and reinforce actual structure and aims to provide data available In designing and constructing reinforced concrete structures under the structural damage. This study obtains the following conclusions. After considering the shear experiment results. it was indicated that the CB reinforced test object was the best in the shear capacity improvement and ductility capacity as it was contained in the concrete and was all operated, Also, GFS reinforced test object indicated the reduced flexural capacity but good shear capacity. GSP reinforced test object had bigger reinforcing strength than other reinforcing test objects. On the other hand, it showed the lowest reinforcement effect as compared section thickness of reinforced material because it showed the bigger relativity a section thickness of reinforced material. If the adherence to the concrete is improved, it will seem to show bigger reinforcement effect.

EFFECTS OF CHOPPED GLASS FIBER ON THE STRENGTH OF HEAT-CURED PMMA RESIN

  • Lee Sang-Il;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.589-598
    • /
    • 2001
  • The fracture of acrylic resin dentures remains an unsolved problem. Therefore, many investigations have been performed and various approaches to strengthening acrylic resin, for example, the reinforcement of heat-cured PMMA resin using glass fibers, have been suggested over the years. The aim of the present study was to investigate the effect of short glass fibers treated with silane coupling agent on the transverse strength of heat-polymerized PMMA denture base resin. To avoid fiber bunching and achieve even fiber distribution, glass fiber bundles were mixed with PMMA powder in conventional mixer whose blade was modified to be blunt. Composite of glass fiber($11{\mu}m$ diameter, 3mm & 6mm length, silane treated) and PMMA resin was made. Transverse strength and Young's modulus were estimated. Glass fibers were incorporated with 1%, 3%, 6% and 9% by weight. Plasticity and workability of dough was evaluated. Fracture surface of specimens was investigated by SEM. The results of this study were as follows 1. 6% and 9% incorporation of 3mm glass fibers in the PMMA resin enhanced the transverse strength of the test specimens(p<0.05). 2. 6% incorporation of 6mm glass fibers in the PMMA resin increased transverse strength, but 9% incorporation of it decreased transverse strength(p<0.05). 3. When more than 3% of 3mm glass fibers and more than 6% of 6mm glass fibers were incorporated, Young's modulus increased significantly(p<0.05). 4. Workability decreased gradually as the percentage of the fibers increased. 5. Workability decreased gradually as the length of the fibers increased. 6. In SEM and LM, there was no bunching of fibers and no shortening of fibers.

  • PDF

Seismic Performance Evaluation of Existing RC Bridge Piers by Pseudo Dynamic Test (유사동적 실험에 의한 기존 RC 교각의 내진성능 평가)

  • 박종협
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.364-371
    • /
    • 2000
  • The pseudo dynamic test has been carried out so as to investigate the seismic performance of RC bridge piers strengthened with and without glass fiber sheets. The Lessons from severe demage of many infrastructures in Kobe(1995) and Northridge(1996) earthquakes have emphasized the need to develop the retrofit measures to enhance flexural strength, ductility and shear strength of RC bridge piers nonseismically designed before 1992. Therefore, the objective of this experimental research is to investigate the seismic behavior of circular reinforced concrete bridge piers by the pseudo dynamic test. and then to enhance the ductility of concrete piers strengthening with glass fiber sheets in the plastic hinge region. 7 circular RC bridge piers were made in a 1/3.4 scale. Important test parameters are confinement steel ratio, retrofitting. load pattern, etc. The seismic behavior of circular concrete piers under artificial ground motions has been evaluated through strength and stiffness degradation, energy dissipation. It can be concluded that existing bridge piers wrapped with glass fibers in the plastic hinge regions could have enough seismic performance.

  • PDF

Preparation of Low Density Water Glass Based Silica Gels by Conventional Drying

  • Einarsrud, Mari-Ann;Elin Nilsen
    • The Korean Journal of Ceramics
    • /
    • v.6 no.1
    • /
    • pp.37-42
    • /
    • 2000
  • To reduce shrinkage and the possibility of fracture during ambient pressure drying, it is of great importance to increase the strength and stiffness of the wet gels. In this paper is presented the strengthening and stiffening of wet silica gels prepared from sodium silicate (water glass) as well as properties of the corresponding xerogels. By washing gels containing different initial silica contents in water solutions at elevated pH, a maximum in shear modulus of ~4 MPa was obtained. The maximum stiffness enabled xerogels with bulk density of 0.28g/$\textrm{cm}^3$ to be made regardless of silica content and washing conditions. However, by aging the wet gels in a solution providing fresh monomers to the gel network, a shear modulus of 20 MPa was obtained after 27h. By this method monolithic xerogels with a density down to ~0.2g/$\textrm{cm}^3$ was prepared. The results are compared to alkoxide based gels.

  • PDF

The Strength Characteristics of Concrete Confined with Composite Fiber (복합섬유(複合纖維) 횡보강(橫補强)콘크리트의 강도(强度) 특성(特性)에 관한 연구(硏究))

  • Jang, Jeong-Su;Jo, Seong-Chan;Gang, Chung-Ryeor
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.2
    • /
    • pp.93-102
    • /
    • 2001
  • The objective of this experimental study is to evaluate the strengthening effects of concrete compression confined with Epoxy-boned compound fiber sheets. An analytical model is proposed to construct a stress-strain relationship for confined concrete. Test results are summarized as followed. While non-FRP lateral confinement specimens appeared sudden failure after shell concrete was torn off, specimens confined laterally with FRP were showed that their failure. Specially, Glass fiber lateral confined specimens occurred obviously increase ductility ability. Hence, concrete specimen with lateral confinement by Hi-carborn and Aramide. Glass fiber simultaneously can be increased in not only strength but also a lot of ductility ability.

  • PDF

Tension-Tension Fatigue and Tension-Tension Bearing Fatigue Characteristics of Glass Fabric/Phenol Composite Laminates for the Internal Components of the High Speed Trains (고속전철 내장부품용 유리섬유 직조 페놀수지 복합재료 적층판의 인장-인장 피로특성 및 인장-인장 베어링 피로특성)

  • 김진봉;황병선;이상관;박지상;조정미
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.904-909
    • /
    • 2002
  • This paper contains the tension-tension and the tension-tension bearing fatigue characteristics of glass fabric/phenol composite laminates. The experimental results show that the bearing fatigue characteristics of the material is so excellent compared with the simple tension fatigue characteristics, that there are no needs of additional strengthening for mechanical joint parts when the parts are properly designed. The experimental data are also compared with the results of glass fabric/epoxy composite laminates.

  • PDF

Mechanical Properties of MWNT-Loaded Plain-Weave Glass/Epoxy Composites

  • Kim, Myung-Sub;Lee, Sang-Eui;Lee, Won-Jun;Kim, Chun-Gon
    • Advanced Composite Materials
    • /
    • v.18 no.3
    • /
    • pp.209-219
    • /
    • 2009
  • Carbon nanotubes (CNTs) have shown great potential for the reinforcement of polymers or fiber-reinforced composites. In this study, mechanical properties of multi-walled carbon nanotube (MWNT)-filled plain-weave glass/epoxy composites intended for use in radar absorbing structures were evaluated with regard to filler loading, microstructure, and fiber volume fraction. The plain-weave composites containing MWNTs exhibited improved matrix-dominant and interlaminar fracture-related properties, that is, compressive and interlaminar shear strength. This is attributed to strengthening of the matrix rich region and the interface between glass yarns by the MWNTs. However, tensile properties were only slightly affected by the addition of MWNTs, as they are fiber-dominant properties.

Shear behaviour of RC T-beams strengthened with U-wrapped GFRP sheet

  • Panda, K.C.;Bhattacharyya, S.K.;Barai, S.V.
    • Steel and Composite Structures
    • /
    • v.12 no.2
    • /
    • pp.149-166
    • /
    • 2012
  • This paper presents an experimental investigation on the performance of 2.5 m long reinforced concrete (RC) T-beams strengthened in shear using epoxy bonded glass fibre fabric. Eighteen (18) full scale, simply supported RC T-beams are tested. Nine beams are used as control beam specimens with three different stirrups spacing without glass fibre reinforced polymer (GFRP) sheet and rest nine beams are strengthened in shear with one, two, and three layers of GFRP sheet in the form of U-jacket around the web of T-beams for each type of stirrup spacing. The objective of this study is to evaluate the effectiveness, the cracking pattern and modes of failure of the GFRP strengthened RC T-beams. The test result indicates that for RC T-beams strengthened in shear with U-jacketed GFRP sheets, increase the load carrying capacity by 10-46%.

Composite aluminum-slab RC beam bonded by a prestressed hybrid carbon-glass composite material

  • Rabahi Abderezak;Tahar Hassaine Daouadji;Bensatallah Tayeb
    • Structural Engineering and Mechanics
    • /
    • v.85 no.5
    • /
    • pp.573-592
    • /
    • 2023
  • This paper presents a careful theoretical investigation into interfacial stresses in composite aluminum-slab reinforced concrete beam bonded by a prestressed hybrid carbon-glass composite material. The model is based on equilibrium and deformations compatibility requirements in and all parts of the strengthened beam, i.e., the aluminum beam, the slab reinforced concrete, the hybrid carbon-glass composite plate and the adhesive layer. The theoretical predictions are compared with other existing solutions. Numerical results from the present analysis are presented both to demonstrate the advantages of the present solution over existing ones and to illustrate the main characteristics of interfacial stress distributions. It is shown that the stresses at the interface are influenced by the material and geometry parameters of the composite beam. This research is helpful for the understanding on mechanical behaviour of the interface and design of the hybrid structures.

Performance Evaluation of Structure Strengthening Using Sprayed FRP Technique (분사식 FRP공법을 이용한 구조물 보강 성능평가)

  • Chang, Chun-Ho;Jang, Kwang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.4 s.56
    • /
    • pp.126-136
    • /
    • 2009
  • The sprayed FRP strengthening technique is combining the Glass fiber and Polyester resin in open air and spraying randomly at concrete's surface with high-speed compressed air. Then it strengthens the structures with a new technique evaluated the structural performance. We applied it to concrete beam and tested for flexural strength, depended on Korea Standard(KS F 2408). Then based on the result of flexural strength, the properties were proposed that applying to structures. Based on the experiment, we have evaluated structural performance by the experiment. 1/5 scale prestressed concrete I-beam were made by Korean Highway's typical drawing in 1993. With these test results, 49.8% increased in flexural strength, improvement of the behavior of serviceability state, and strengthening was surely effective for controlling deflection and crack of structure. Consequently, it can be summarized that Sprayed FRP technique has prospect to improve the performance of structure.