• Title/Summary/Keyword: Glass panels

Search Result 172, Processing Time 0.025 seconds

A Simulation Model for Vaccum-Driven Bonding of Glass Panels in the Cell Process for LCD Manufacturing (LCD 유리원판 진공식 합착공정 해석을 위한 수치모델)

  • Ji Chul-Wook;Kwak Ho Sang;Kim Kyoung Hoon
    • Journal of computational fluids engineering
    • /
    • v.8 no.2
    • /
    • pp.33-41
    • /
    • 2003
  • A simplified simulation model is designed to investigate the vacuum-driven bonding of glass panels in the cell process for LCD manufacturing. The bonding process is modelled by the transient flow of a weakly-compressible fluid in a very thin channel between two horizontal glass panels. An order of magnitude scaling analysis is conducted based on the characteristic feature of the channel of which height is much smaller than the horizontal length scales. It is revealed that the flow in the channel is represented by a Poiseuille flow of a compressible fluid. A finite volume model has been constructed to acquire the numerical solution to the derived simplified equations. For a simple test problem of pressure-driven microchannel flow, an assessment is made of the accuracy and validity of the proposed model. The basic aspects of vacuum-driven bonding are examined numerically, and the applicability of the present simulation model is illustrated.

Stiffness Comparison with Design of GFRP Roof Panels Prepared by RTM Method (RTM 성형 GFRP 차체 설계에 따른 강성연구)

  • 유용문;윤의박;윤여성;이순홍
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.4
    • /
    • pp.32-38
    • /
    • 1998
  • In order to investigate the relationship between the stiffness and structure of the automotive roof panels, two kinds of glass fiber reinforced plastic(GFRP) roof panels without and with insert material were fabricated by resin transfer molding(RTM) method. The stiffness test was performed at the same condition as it of actual driving. The structural design and material selection for improving the recyclability of GFRP roof panels were also covered.

  • PDF

Numerical Study on the Air-Cushion Glass Transportation Unit for LCD Panels

  • Im Ik-Tae;Jeon Hyun-Joo;Kim Kwang-Sun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.1 s.14
    • /
    • pp.27-31
    • /
    • 2006
  • Non-contact transportation system using air cushion for the manufacturing of large-sized LCD panels was considered. Flow characteristics between air pad and glass plate was analyzed using computational fluid dynamics method to obtain optimized air pad configurations. Effects of the design variables such as hole arrays from which gas is injected, gas-feeding method into the gas supplying channels, and horizontal and vertical pitches of clusters of holes were studied. Optimized air pad unit gave evenly distributed pressure contour on the glass surface and well-suspended levitation height in the experiment.

  • PDF

Study on Quality Criteria for Transparent Soundproof Panels(1) - Evaluation of Mechanical Performance and Safety (투명방음판의 품질기준 설정에 관한 연구(1) - 기계적 특성 및 안전성 평가)

  • Chang, Tae-Sun;Kim, Chul-Hwan;Hwang, Cheol-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.12
    • /
    • pp.1111-1120
    • /
    • 2010
  • A variety of materials may be used for soundproof panels. The major advantage of transparent material over traditional materials in noise barriers is aesthetics. The transparent panel materials such as clear plastic or glass are an ideal way of reducing or virtually eliminating the visual impact of a noise barrier. With the use of transparent materials, the drivers' view of the roadside and the sunlight penetration to the highway would not be blocked. Korean Industrial Standards for soundproof panels have been established. But, transparent soundproof panels are not included in this standards. And, some specifications provide only a few basic characteristics for transparent soundproof panels. To develop guidelines on quality criteria for transparent soundproof panel, their mechanical properties such as wind load resistance, safety under impact, and abrasion resistance were experimentally investigated.

Thermochemical Stability and Mechanical Properties of Ceramic-Filler Added BaO-ZnO-$B_2O_3$ Based Glass for Application to Barrier Rib in Plasma Display Panels

  • Kim, Sang-Gon;Shin, Hyun-Ho;Park, Jong-Sung;Hong, Kug-Sun;Kim, Hyung-Sun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.220-222
    • /
    • 2004
  • Feasibility of BaO-ZnO-$B_2O_3$ (BZB) based glass system in the light of dielectric and thermal expansion properties are reported in the literature. Effects of addition of various types of ceramic fillers to the BZB-based glass on the thermochemical stability and mechanical properties were investigated in the present work. The studied filler-glass system demonstrated a capability to host various types of ceramic fillers to form thermochemically stable microcomposites at the processing temperature suitable for PDP systems. At the same time, mechanical strength of the filler-glass composites was much improved as compared to the glass itself These observations brighten the feasibility of the Pb-free BZB-based glass system as a host to employ various types of crystalline ceramic fillers so that it can be applied to barrier rib material in plasma display panels.

  • PDF

Electrostatic Suspension System of Glass Panels using Relay Feedback Control (릴레이 제어법을 이용한 유리패널의 정전부상에 관한 연구)

  • Jeon, Jong-Up
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.6
    • /
    • pp.71-79
    • /
    • 2008
  • In the manufacture of flat panel display devices, there is a strong demand for contactless glass panel handling devices that can manipulate a glass panel without contaminating or damaging it. To fulfill this requirement, an electrostatic suspension device far glass panels where the glass panel is supported by electrostatic forces without any mechanical contact is proposed. To implement the system with low cost and compactness, switched-voltage control scheme that is based on the relay feedback control is utilized. Relay feedback control method deploys only a single high-voltage power supply that can deliver a DC voltage of positive and/or negative polarity and thus high voltage amplifiers that are costly and bulky are not needed any more. It is shown that despite the inherent limit cycle property of the relay feedback based control, an excellent performance in vibration suppression is attained due to the presence of a relatively large squeeze film damping originating from the electrodes and levitated object. Using this scheme, a $100{\times}100mm^2$ glass panel was levitated stably with airgap variation decreasing down to $1\;{\mu}m$ at an airgap of $100\;{\mu}m$.

Compression Characteristics and Energy Absorption of Composite Egg-Box Panels (직물 복합재료 계란판의 압축 특성과 에너지 흡수율)

  • Chung, Jee-Gyu;Chang, Seung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.12 s.255
    • /
    • pp.1603-1610
    • /
    • 2006
  • In this paper compressive characteristics of composite egg-box panels were investigated and energy absorption was calculated from the nominal stress-strain relations obtained by the compressive tests. Several different stacking sequences and number of plies were introduced for investigation of static compression characteristics and the energy absorption rates of composite egg-box panels. The compressive stress-strain relation and energy absorption of various composite egg-box panels were compared with those of aluminium egg-box panels. From the test results it was found that the fracture behavior of composite egg-box panel was affected by stacking angle causing different local deformation, during lay-up and draping processes and types of prepreg; that is, plain weave carbon/epoxy and 4-harness satin glass/epoxy. The energy absorption capacity of composite egg-box panels were proved to be higher than that of aluminium egg-box panels with low mass.

Structural Behavior of R/C Slabs Strengthened by Glass Fiber Reinforced Plastic-Panels (유리섬유 보강패널로 보강된 철근콘크리트 슬래브의 구조거동에 관한 연구)

  • Kim, Woo;Kim, Haeng-Joon;Lee, Sung-Moon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.751-756
    • /
    • 2000
  • The structural behavior of reinforced concrete slabs strengthened by glass fiber reinforced plastic-panels experimentally investigated. The experimental variables are strengthening length, strengthening width, and pre-crack existence. The pre-cracked slabs are initially loaded to 70 percent of ultimate flexural capacity and subsequently repaired with GFRP-Panels bonded to the tension face of the slabs. Five one-way slabs were tested to failure. The main failure mode of strengthened slabs is separation failure by crack propagation from load point section to end of plate. The behavior of strengthened slabs is represented by a maximum load, load-deflection curves an load-strain curves.

  • PDF

A Basic Study of Production System Development of Free-form Concrete Panels (비정형 콘크리트 패널 생산 시스템 구축 기초연구)

  • Son, Seung-Hyun;Kim, Ki-Ho;Kim, Sun-Kuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.70-71
    • /
    • 2019
  • Glass fiber reinforced concrete (GFRC) is very suitable as a material for free-form concrete panels (FCPs) because of its lightweight, strong, moldable, durable and sustainable properties. GFRC is superior in construction and maintenance compared with materials such as steel, aluminium, titanium, glass and plastic, and is advantageous in cost. However, GFRC is being produced by skilled craftsmen, and still lacks the technology to economically produce high quality FCPs. Currently, there is a technology to automatically and accurately produce FCPs. However, the developed technology can not be applied to the field with simple production technology without production line for mass production. To solve this problem, the purpose of this study is a basic study of production system development of free-form concrete panels. This study introduces the developed FCPs production technology and builds FCP production system for mass production. The results of this study will be used as basic data for the commercial production of FCPs in the future.

  • PDF

The effect of curvature on the impact response of foam-based sandwich composite panels

  • Yurddaskal, Melis;Baba, Buket Okutan
    • Steel and Composite Structures
    • /
    • v.20 no.5
    • /
    • pp.983-997
    • /
    • 2016
  • The aim of this study is to investigate the impact behavior and impact-induced damage of sandwich composites made of E-glass/epoxy face sheets and PVC foam. The studies were carried out on square flat and curved sandwich panels with two different radius of curvatures. Impact tests were performed under impact energies of 10 J, 25 J and 80 J using an instrumented drop-weight machine. Contact force and displacement versus time and contact force- displacement graphs of sandwich panels were presented to determine the panel response. Through these graphs, the energy absorbing capacity of the sandwich panels was determined. The impact responses and failure modes of flat and curved sandwich panels were compared and the effect of curvature on sandwich composite panel was demonstrated. Testing has shown that the maximum contact force decrease while displacement increases with increasing of panel curvature and curved panels exhibits mixed failure mode, with cylindrical and cone cracking.