• Title/Summary/Keyword: Glass ionomer

Search Result 323, Processing Time 0.024 seconds

HARDNESS CHANGE OF LIGHT-ACTIVATED GLASS IONMER CEMENT WITH THICKNESS AND TIME (광경화형 글래스아이오노머 시멘트의 두께 및 시간경과에 따른 경도의 변화)

  • Lee, Kyoung-Jin;Oh, Won-Mann;Kim, Sun-Hun
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.303-315
    • /
    • 1995
  • An adequate and homogeneous cure of light-activated restroative material is very important for improvement of marginal adaptation and prevention of marginal leakage, secondary caries and pulpal irritation as well as expressing natural physical property of that material. The purpose of this study was to evaluate the change of surface hardness and cure uniformity of light-activated glass ionomer cements. Restorative(Fuji II LC, Vitremer) and lining(Baseline VLC, Vitrebond) light-activated glass ionomer cements were investigated for this study. The surface hardness of the top and bottom surfaces and cure uniformity of each 1mm, 1.5mm, 2mm, 2.5mm & 3mm in the thickness of specimen were measured immediately, at 1 hour, 24 hours and 1 week after light activation. The surface hardness change and cure uniformity of all the specimens were measured by Knoop hardness tester. The results were as follows. 1. The surface hardness of top and bottom surfaces in all groups increased with time(p<0.01). 2. Both top and bottom surfaces hardness of Vitrebond group measured immediately after light-activation were significantly lower than those of the other groups(p<0.01). 3. The surface hardness of top and bottom surfaces of restorative light -activated glass ionomer cements was higher than those of lining materials at 1 week(p<0.10). 4. Surface hardness of Vitremer group decreased as the specimen thickness increased, except top and bottom surfaces hardness of the specimen at 1 week(p<0.01). There was no significant difference in the surface hardness of Fuji II LC with changes in the thickness except bottom surface hardness of specimen at 24 hours and 1 week (p>0.05). 5. Surface hardness of Vitrebond group significantly decreased as the specimen thickness increased(p<0.01). There was no significant difference in the surface hardness of Baseline VLC group with changes in the thickness except bottom surface hardness of specimen measured immediately after light -activation(p>0.05). 6. The hardness ratio of top against bottom surface in all groups decreased with time(p<0.05). 7. There was no significant difference in the hardness ratio of top against bottom surface with changes of the thickness except Vitrebond group, 24 hours and 1 week of Vitremer group and 1 week of Baseline VLC group (p>0.05). These results suggest that surface hardness of restorative ligh-activated glass ionomer cements were highter than those of lining light-activated materials. In all groups, the surface hardness and cure uniformity continuously increased with time.

  • PDF

Treatment of Palatogingival Groove using Glass-Ionomer cement and Emdogain$^{(R)}$ (Original Article 2 - 글라스-아이오노머 시멘트와 Emdogain$^{(R)}$을 이용한 구개치은발육구의 치료)

  • Jin, Myoung-Uk
    • The Journal of the Korean dental association
    • /
    • v.48 no.1
    • /
    • pp.56-62
    • /
    • 2010
  • In recent years, a number of special treatment procedures have been introduced to reestablish new tooth supporting tissues with varying degrees of success including guided tissue regeneration(GTR), bone grafting(BG) and the use of enamel matrix derivative(EMD). EMD is an extract of enamel matrix and contains amelogenins of various molecular weights. Emdogain(EMD) might have some advantages over other methods of regenerating the tissue supporting teeth lost by gum disease, such as less postoperative complications. Emdogain contains proteins(derived from developing pig teeth) believed to regenerate tooth attachment. The decrease in probing depth after EMD treatment is achieved primarily by clinical attachment gain and bone regeneration and only to a minor extent by gingival recession. In conclsion, EMD seems to be safe, was able to regenerate lost periodontal tissues in previously diseased sites based on clinical parameters.

Relationship between Structure and Properties of UV-Curable Polyurethane Acrylate Ionomers

  • 김태우;김한도
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 1996.10a
    • /
    • pp.468-472
    • /
    • 1996
  • A series of UV-curable polyurethane acrylate ionomer were synthesized from isophorone diisocyanate(IPDI), poly(tetramethylene ether glycol)(PTMG), 2,2-bis(hydroxymethyl)propionic acid (CMPA), triethylamine(TEA), 2-hydroxy ethyl acrylate (HEA), and dibutyl tin dilaurate (DBT) as a catalyst. 2,2-dimethoxy-2-phenyl acetophenone(DMPAP) was used as a photoinitiator. The films of UV-cured polyurethane acylate ionomer were prepared by casting the formulated materials onto a glass plate at room temperature and cured using a medium pressure mercury lamp (80 W/cm, max = 365nm). Effects of DMPA content, molecular weight of PTMG and degree of neutralization on the properties were invesigated. It is found that the storage modulus increased with increasing DMPA content. The glass transition temperature of sample A shifted to higher temperature as the content of DMPA was increased. Tensile modulus also increased with increasing DMPA content. Modulus and Tg decreased with increasing molecular weight of PTMG form 650 to 2000. With increasing the degree of nutralizaion, ionomers exhibited improved modulu.

  • PDF

A STUDY ON POROSITY FORMATION IN COMPOSITE RESIN FILLING MATERIALS (복합(復合)레진충전물내(充塡物內)의 기포형성(氣泡形成)에 관(關)한 연구(硏究))

  • Kim, Yung-Hai
    • Restorative Dentistry and Endodontics
    • /
    • v.7 no.1
    • /
    • pp.71-75
    • /
    • 1981
  • Five different labelled composite resin, Hypol (Korea), Glass-Ionomer (Japan), Simulate (U.S.A.), Durafil (U.S.A.) and Microfil (U.S.A.) were collected to employ for this experimental study. The purpose of the study is to determine the effect of finger pressure technic and traditional filling by means of plastic instruments on porosity formation in composite materials. Each material with pressure and non-pressure cases were carefully examined under electron microscope. Following were the results obtained through the study. 1. Pressured cases showed smaller number of porosity and the size of porosity was significantly smaller than non-pressured cases in each mateial. 2. Glass-Ionomer with pressure cases were seen as tube-like appearance because of pressured small porosities communicate in a certain direction. 3. Durafil cases both pressured and non pressured, appeared the least porosity formation. among the materiats. 4. Border line between the outmost periphery of the porosity and matrix of the resin in both pressured or non-pressured eases were found characteristically clear in Mierofil cases.

  • PDF

Sealing Ability of Three Different Materials Used as Retrograde Filling

  • Park, Ji-Hoon;Kang, Seung-Bok;Choi, Yong-Hoon;Bae, Ji-Hyun
    • Journal of Korean Dental Science
    • /
    • v.5 no.2
    • /
    • pp.60-67
    • /
    • 2012
  • Purpose: To test the apical leakage prevention performance of three different materials through protein leakage procedures using bovine serum albumin (BSA) and Bradford protein reagent. Materials and Methods: A total of 60 human single-rooted teeth were divided into 4 groups, and conventional root canal filling was done. The root was cut 3 mm from the apex, and a cavity was formed. Proroot MTA (MTA), Fuji II LC (GI), Fuji II LC with XP bond (GIA), and Caviton (CA) were used as experimental materials to fill the cavity in a retrograde filling manner. The extent of BSA leakage was then measured with a ultraviolet visible spectrophotometer 24, 48, and 72 hours after filling. Result: After 24 hours, among the 15 teeth of each group, 2 in MTA, 4 in GI, 3 in GIA, and 7 in CA showed leakage. After 48 hours, 3 in MTA, 5 in GI, 5 in GIA, and 10 in CA had leakage and discoloration. After 72 hours, among the 15 teeth of each group, 3 in MTA, 6 in GI, 5 in GIA, and 10 in CA showed leakage. The leakage in the CA group was greater than that in the MTA group at 48 and 72 hours based on Fisher's exact test (P=0.025), and the difference was statistically significant. Similarly, the leakage in the CA group was greater than that in the MTA group over time based on the Kaplan-Meier survival estimate (P=0.011), and the difference was statistically significant. Conclusion: Glass ionomer, glass ionomer after adhesive application, and MTA all showed leakage. Caviton showed greater leakage compared to MTA 48 and 72 hours after filling, and the difference was statistically significant; thus suggesting that Caviton is not appropriate as retrograde filling material considering its sealing ability.

A Study on the Radiopacity of Cavity Lining Materials for Posterior Composite Resin Restoration (구치부 복합레진 수복을 위한 와동 이장용 재료의 방사선투과성에 관한 연구)

  • Moon Joo-Hoon;Choi Eui-Rwan
    • Imaging Science in Dentistry
    • /
    • v.30 no.4
    • /
    • pp.243-248
    • /
    • 2000
  • Purpose: The aim of this study was to determine the relative radiopacities of cavity lining materials (Resin-modified Glass Ionomer cement, Compomer and Plowable resin) for posterior composite resin restoration. Material & Methods: Resin-modified glass ionomer cement (Fuji II LC, Vitrebond/sup TM/), Compomers (Dyract /sup (R)/ Compoglass, F2,000, Dyract/sup (R)/ flow Compoglass Flow) and Flowable resins (Tetric/sup (R)/ flow, Aeliteflo/sup TM/ Revolution/sup TM/) were used. Five specimens of 5 mm in diameter and 2 mm thick were fabricated with each material. Human molars were horizontally sectioned 2 mm thick to include both enamel and dentin. The radiopacities of enamel, dentin, cavity lining materials, aluminum step wedge were obtainded from conventional radiograph and NIH image program. Results: All the tested lining materials showed levels of radiopacity the same as or greater than that of dentin. All compomer tested (Dyract, Compoglass, F2,000, Dyract flow, Compoglass Flow) and Vitrebond/sup TM/, Tetric/sup (R)/ flow were more radiopaque than enamel. The radiopacities of Fuji II LC and Revolution/sup TM/ were between enamel and dentin and resin-modified glass ionomer cement, Compomer and Tetric/sup (R)/ flow were greater than those of Revolution/sup TM/, Aeliteflo/sup TM/ or dentin. The level of radiopacity of the tested materials was variable; those with low radiopacity should be avoided in class II restorations, where a clear determination of recurrent caries by the examining clinician could be compromised. Conclusion: Clinician should be able to distinguish these cavity lining materials radiographically from recurrent decay, voids, gaps, or other defects that lead to clinical failure. Utilization of materials ranked more radiopaque than enamel would enable clinicians to distinguish the lining material from tooth structure.

  • PDF

FRACTURE TOUGHNESS OF VARIOUS CORE MATERIALS

  • Lee Shin-Won;Lee Sun-Hyung;Yang Jae-Ho;Han Jung-Suk;Lee Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.682-697
    • /
    • 2001
  • This investigation evaluated the fracture toughness($K_{IC}$) of eight currently available core materials, and relate the fracture toughness value to fractography analysis and surface characteristics using a atomic force microscope (AFM). Single-edge notched (SEN) test specimens (n=10) and compact tension (CT) test specimens (n=10) were prepared conforming to the ASTM Standard E-399 for a high copper amalgam, three composite core materials (Core-Max II, Core Paste, Bisfil Core), two reinforced composite core materials (Ti-Core, Ti-Core Natural), a resin-modified glass ionomer core material (Vitremer), and a conventional glass ionomer core material (Ketac-Molar). The specimens were tested with an Instron Universal Testing Machine. The maximum loads were measured to calculate the fracture toughness ($K_{IC}$). Thereafter, fracture surfaces of SEN specimens of each material were investigated for fractography analysis using scanning electron microscope. And, disc-shaped specimens with 1mm thickness were fabricated for each material and were investigated under AFM for surface morphology analysis. The results were as follows: 1. Bisfil Core showed the highest mean fracture toughness regardless of test methods. 2. For the tooth-colored materials, Ti-Core Natural exhibited the highest fracture toughness. 3. Ketac Molar showed a significantly low fracture toughness when compared with the amalgam and the composite resin core materials(p<0.05). 4. The fracture toughness values obtained with the single-edge notched test, except Ketac Molar, were higher than those obtained in the compact tension test. 5. SEM revealed that the fracture surface of high fracture toughness material was rougher than that of low fracture toughness material. 6. AFM revealed that the surface particles of the composite resins were smaller in size, with a lower surface roughness than the glass ionomer core materials.

  • PDF

INFLUENCE OF THE EVAPORATOIN OF LIQUIDS OF DENTAL CEMENTS ON THE PROPERTIES OF HARDENED CEMENTS (치과용 시멘트 용액의 증발이 경화된 시멘트의 성질에 미치는 영향)

  • Kim, Hyang-Kyung;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.156-169
    • /
    • 1997
  • This study was designed to evaluate the influences of evaporation of liquid of dental cements by drying during long term using. Zinc phosphate cement, polycarboxylate cement, and glass ionomer cement were used, and evaluated the properties as follows; consistency, setting time, film thickness, solubility, and compressive strength according to the ADA specification. The specimens of control group were made by mixing the newly opened liquid using the powder-liquid ratio recommended by the manufacturer, and the specimens of ES groups were made by mixing the 10% evaporated liquid by drying with the powder-liquid ratio recommeded by the manufacturer, and the specimens of EM group were made by mixing the 10% evaporated liquid with the powder-liquid ratio modified for standard consistency. The following conclusions were drawn ; 1. The viscosity of mixture of all kinds of cements were increased by the evaporation of liquid, especially the viscosity of glass ionomer cement were influenced significantly. 2. The amount of liquid should be increased to get a standard consistency at the using of evaporated liquid of cement, the most significant increase of liquid amount was required on Ketac-Cem. 3. The setting times were increased at both cases of mixing of evaporated liquid with powder - liquid ratio recommended by manufacturer or modifided through consistency test. 4. At an experimental group of mixing of the evaporated liquid with powder-liquid ratio recommended by manufacturer, solubility was decreased and film thickness was increased. 5. By the result of evaporation of cement liquid, the compressive strength of polycarboxylate cement was increased slightly and it of glass ionomer cement was increased, however, by the increase of amount of liquid to be possible to manipulate the compressive strength were decreased.

  • PDF