• 제목/요약/키워드: Glass Filter

검색결과 221건 처리시간 0.025초

거름종이가 미량 분석 결과에 미치는 영향 (The Effect of Filter Paper on the Results of Trace Analysis)

  • 임헌성;이석근
    • 분석과학
    • /
    • 제16권2호
    • /
    • pp.174-178
    • /
    • 2003
  • Analytical chemists frequently use filter papers during the course of experiments without any hesitation. However, the results of analysis could be deteriorated by the various ions which are extracted from filter papers. In some filter paper made for qualitative use, about $300{\mu}g$ sodium and many other cations were detected. Although the quantities of contaminants was low in the filter paper made for quantitative use, significant amount of Fe, Si, Al, Cu and Zn was detected as well as alkali element. Many cations and anions were also detected in the filtrate obtained from the glass fiber filter.

UV meter용 패브리-페로 간섭필터 제작 및 광학특성연구 (The optical characteristic of Fabry-Perot interferometer filter for UV meter)

  • 박문찬;정부영;최혜정;진가헌;황보창권;김형두
    • 한국안광학회지
    • /
    • 제9권2호
    • /
    • pp.463-471
    • /
    • 2004
  • 패브리-페로 형태의 UV용 투과필터를 광학용 설계 프로그램을 이용하여 설계한 후, 설계치를 근거로 하는 두개의 투과필터를 제작하여 광학적 특성을 조사하였다. 투과 영역의 투과율은 반사경으로 사용한 Ag 박막의 두께로 조절하였으며, 투과 파장을 spacer 층으로 사용된 $SiO_2$ 층의 두께로 조절하였다. 시료의 제작은 RF magnetron sputtering법을 이용하였으며, 제작 시료의 구조는 다음과 같다. [air|$SiO_2$(174.6 nm)|Ag(78 nm)|$SiO_2$(68 nm)|Ag(78 nm)|Cr(5 nm)|glass], [air|$SiO_2$(174.6 nm)|Ag(58 nm)|$SiO_2$(56 nm)|Ag(58 nm)|Cr(5 nm)|glass]. 제작한 LV용 투과필터의 광학적 특성은 분광광도계를 이용해서 측정하였다. UV용 투과필터에 의한 투과율은 약 370nm에서 6% 이였으며, 400 nm에서는 0.2% 이하이었다. Ag의 두께를 얇게 함에 따라 투과율을 증가시킬 수 있었으며, spacer 층으로 사용된 $SiO_2$ 층의 두께를 조철하여 투과영역을 조절할 수 있었다.

  • PDF

고성능 멜트블로운 부직포 복합필터 개발 (Development of composite filter with high performance meltblown non-woven)

  • 이재달;홍영기;배기서
    • 한국염색가공학회지
    • /
    • 제17권2호
    • /
    • pp.40-45
    • /
    • 2005
  • Electret filter is good enough to protect health and environment from air pollution. The reason why is gathering particles not only by mechanical mechanism but also by electrostatic attraction. Especially this filter is shown lower pressure drop than general mechanical filters as glass fiber. For making electret filter media using polypropylene meltblown(M/B) nonwoven, the nonwoven is charged with corona which was supplied high voltage DC, AC, and pulse with DC power. The electret filter media is tested with $0.3{\mu}m$ sodium chloride and dioctyl phthalate(DOP) aerosol. Results revealed that filtration performance of electret filter media increased as corona was applied with higher voltage and with AC power rather than DC, and fiber diameter was fine and uniform.

도금공정 공기중 6가 크롬 시료채취여과지 비교에 관한 연구 (Comparison of Sampling Filters for Airborne Hexavalent Chromium in Plating Operation)

  • 이병규;신용철
    • 한국환경보건학회지
    • /
    • 제29권2호
    • /
    • pp.69-76
    • /
    • 2003
  • Hexavalent chromium may reduce on polyvinyl chloride (PVC) filter during sampling and storage of sample. Recently, new or modified filters for preventing Cr(VI) from the reduction has been introduced. Thus, this study was performed to compare the reduction behaviors of Cr(VI) on several sampling filters and to find the most appropriate filter for airborne Cr(VI) sampling in plating operation. The results were as follows. 1. There were statistically significant differences among PVC, polytetrafluoroethylene (PTFE). glass fiber (GF) and polyvinylidene fluoride (PVDF) filters in recovery rates of spiked Cr(VI) samples by storage time(p<0.05). There was no significant difference between PVC and PTFE filters(p>0.05). The PVC and PTFE filters showed higher recoveries than GF and PVDF filters(p<0.05). 2. The quartz fiber(QF) filter treated with an alkali solution(2% NaOH/3% Na$_2$CO$_3$, 1% NaOH) showed a significantly higher recovery of Cr(VI) by storage time than other filters(GF and QF filter)(p<0.05). There was no difference in recovery of Cr(VI) between alkali-treated and untreated GF it filters(p>0.05). But the QF filters treated with two alkali solution showed a significantly higher recovery than the untreated QF filter(p<0.05). There was no significant difference in recovery of Cr(VI) between QF filters treated with 1% NaOH and 2% NaOH/3% Na$_2$CO$_3$(p>0.05). In conclusion, treatment of QF fillers with alkali solution was most effective in protecting from the reduction of Cr(VI).

클린룸 내 롤러 컨베이어 운송장치 주위의 유동해석 (Flow Analysis around the Roller Conveyor in a Clean Room)

  • 전현주;박찬우;임익태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1507-1512
    • /
    • 2009
  • Flow field in a roller conveyor system, induced from the movement of a cassette in which glasses for flat panel display are loaded, is numerically studied in this paper. Contamination on the glass surface by dust particles produced from mechanical friction between roller and cassette is predicted from the analysis results of flow fields. Results show that a large swirl flow is formed under the moving cassette with constant speed. This swirl flow is confined only under the cassette because two main streams from the backward and the fan filter unit on the top ceiling are sufficiently strong. Therefore, it can be said that possibility of the contamination by the particles originated from the friction is relatively low. It is also revealed that flow direction between glass plates is changed according to the speed of the cassette movement due to the shear force of glass plates.

  • PDF

RF 마그네트론 스퍼터링에 의한 ZnO 박막 SAW 필터에 관한 연구 (A Study on the ZnO Thin Film SAW Filter by RF Sputter)

  • 박용욱;신형용;박정흠;강종윤;심성훈;최지원;윤석진;김현재;김경환
    • 한국전기전자재료학회논문지
    • /
    • 제14권6호
    • /
    • pp.481-486
    • /
    • 2001
  • ZnO thin films on glass substrate were depostied by RF magnetron reactive sputter with various argon/oxygen gas ratios and substrate temperatures. Crystallinities, surface morphologies, chemical compositions, and electrical properties of the films were investigated by XRD, SEM, XPS and electrometer(keithley 617). All films showed a strong preferred orientation along the c-axis on glass substrate, and the chemical stoichiometry was obtained at Ar/O$_2$.=50/50. The propagation velocity of ZnO SAW filter was about 2,590 m/sec and insertion loss was a minimum value of abut -21dB.

  • PDF

용매 포집장치가 연기 중 Carbonyl 화합물의 분석에 미치는 영향 (The Effect of Solvent Trap Apparatus on the Analysis of Carbonyl Compounds in Cigarette Smoke)

  • 김효근;이존태;윤오섭;이문수
    • 한국연초학회지
    • /
    • 제25권2호
    • /
    • pp.137-143
    • /
    • 2003
  • Among the most popular means of mainstream smoke collection for specific analysis are solvent traps. Determination of the carbonyl compounds as their 2,4-dinitrophenylhydrazones(DNPHs) by HPLC offers increased sensitivity and reproducibility in the analysis of mainstream cigarette smoke. In this work, the mainstream smoke of a reference cigarette(lR4F) was collected in four kinds of gas washing bottles and their effects on the analysis of carbonyl compounds were investigated. The results show that the porosity of fritted glass filter in gas washing bottles exerted profound effect on the composition of the carbonyl compounds in mainstream smoke.

Sorbent Thermal Desorption/Gas Chromatography/Mass Selective Detection Method for Determination of Gaseous Polycyclic Aromatic Hydrocarbons in Indoor Air

  • Dai, Shugui;Zhang, Lin;Zhu, Tan
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.753-758
    • /
    • 1995
  • Thermal desorption/gas chromatography/mass selective detection method using Tenax cartridges for the determination of gaseous polycyclic aromatic hydrocarbons(PAH) is described. Glass fiber filter can collect only PAH in particulate. Gaseous PAH may penetrate the filter. Glass cartridge packed Tenax-GC was uses fur adsorption of gaseous PAH. The air of inhalation zone was collected fur 2-10 hours. Cartridges were thermally desorbed in the reverse direction to sample flow. The desorption conditions were as follows; desorption temperature; $300^{\circ}C$; desorption time; 20min; column head pressure; 30psi; inlet split vent; closed during desorption.

  • PDF

RF 마그네트론 스퍼터링에 의한 ZnO 박막 SAW 필터에 관한 연구 (A Study on the ZnG Thin Film SAW filter by RF Sputter)

  • 박용욱;이동윤;백동수;윤석진;김현재;박창엽
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.151-154
    • /
    • 1999
  • ZnO thin films on glass substrate were deposited by RF magnetron reactive sputter with various argodoxygen gas ratios and substrate temperatures. Crystallinities, surface morphologies, chemical compositions, and electrical properties of the films were investigated by XRD, SEM, XPS and electrometer(keith1ey 617). All films showed a strong prefered orientation along the c-axis on glass substrate, and the chemical stoichiometry was obtained at Ar/$O_2$=50/50. The propagation velocity of ZnO SAW filter was about 2, 590 dsec and insertion loss was a minimum value of about -21dB.

  • PDF

다공성 패드를 갖는 챔버의 배열에 따른 공기 부상 테이블의 비접촉 부상 수준에 대한 연구 (Non-Contact Level on Air Levitation Table with Porous Chamber Array)

  • 김준현;정영석;이태걸;김태훈;정효재
    • 한국생산제조학회지
    • /
    • 제22권6호
    • /
    • pp.913-920
    • /
    • 2013
  • This paper presents an applicable basic design that can configure non-contact levitation table for conveying a large sheet of glass. The suggested air levitation table consists of a series of air chambers with porous pads and fans as the conveyor system. The air supply chambers are arrayed to supply an adequately strong upward airflow for supporting the glass. Levitation is controlled by the size and discharge velocity, of the chamber arrays, as well as the glass supporting height. After pre-evaluation of the glass rigidity and the filer functional performance, a one-way fluid structure interface (FSI) analysis is performed for predicting pressure and deflection working of the 8G glass in the transverse and longitudinal directions, respectively. After comparing calculated levels of flatness of the glass, it determines the chamber array for the linear non-contact conveying motion.