• Title/Summary/Keyword: Glass Fiber Cooling

Search Result 25, Processing Time 0.019 seconds

A Study on Injection Condition Optimization and Deformation Improvement using Taguchi Design of Experiments (다구찌 실험계획법을 이용한 사출 조건 최적화와 변형 개선에 대한 연구)

  • Young-Tae Yu;Sung-Min Mun;Sung-Young Jun;Kyoung-A Kim
    • Design & Manufacturing
    • /
    • v.17 no.2
    • /
    • pp.62-69
    • /
    • 2023
  • In this study, we conducted a study on the optimization of injection molding conditions to minimize deformation of plastic product. The charging management system housing of the vehicle was selected as the research subject. Melting temperature, cooling temperature, packing time, and packing pressure were selected as the main factors expected to affect the deformation of molded products. Each main factor was divided into 5 levels. Optimization of injection molding conditions to minimize deformation was performed using the Taguchi Method. We performed an analysis of variance (ANOVA) to identify significant factors affecting the deformation of plastic product. In order to select injection molding conditions that minimize deformation of plastic products, injection molding analysis was additionally performed for insignificant factors. We then compared the deformation of the molded part before and after optimization. As a result of comparing the injection analysis results of the basic conditions and the injection analysis results of the optimal conditions, it was confirmed that the amount of deformation after optimization was improved by about 10.9%.

Effects of Molding Condition on Surface Unevenness of GFRP Composites in Compression Molding (GFRP 복합재료의 압축성형에서 표면요철에 미치는 성형조건의 영향)

  • Kim, Hyoung-Seok;Kim, Jin-Woo;Kim, Yong-Jae;Lee, Dong-Gi
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1649-1657
    • /
    • 2010
  • We have investigated the unexpected phenomena on the surface of molded GFRP composites. The major cause of the unevenness, as a result of which the surface becomes rough, is a shrinking of the matrix in the process of holding pressure and cooling temperature. The higher holding pressure load in a molding process and the lower demolding temperature in an annealing experiment, the better GFRP composites moldings improved its appearance. In addition, by taking the holding pressure and demolding temperature into consideration, we evaluate the process that causes the surface unevenness and the variation in the fiber projection height.

In vivo verification of regional hyperthermia in the liver

  • Noh, Jae Myoung;Kim, Hye Young;Park, Hee Chul;Lee, So Hyang;Kim, Young-Sun;Hong, Saet-Byul;Park, Ji Hyun;Jung, Sang Hoon;Han, Youngyih
    • Radiation Oncology Journal
    • /
    • v.32 no.4
    • /
    • pp.256-261
    • /
    • 2014
  • Purpose: We performed invasive thermometry to verify the elevation of local temperature in the liver during hyperthermia. Materials and Methods: Three 40-kg pigs were used for the experiments. Under general anesthesia with ultrasonography guidance, two glass fiber-optic sensors were placed in the liver, and one was placed in the peritoneal cavity in front of the liver. Another sensor was placed on the skin surface to assess superficial cooling. Six sessions of hyperthermia were delivered using the Celsius TCS electro-hyperthermia system. The energy delivered was increased from 240 kJ to 507 kJ during the 60-minute sessions. The inter-session cooling periods were at least 30 minutes. The temperature was recorded every 5 minutes by the four sensors during hyperthermia, and the increased temperatures recorded during the consecutive sessions were analyzed. Results: As the animals were anesthetized, the baseline temperature at the start of each session decreased by $1.3^{\circ}C$ to $2.8^{\circ}C$ (median, $2.1^{\circ}C$). The mean increases in temperature measured by the intrahepatic sensors were $2.42^{\circ}C$ (95% confidence interval [CI], 1.70-3.13) and $2.67^{\circ}C$ (95% CI, 2.05-3.28) during the fifth and sixth sessions, respectively. The corresponding values for the intraperitoneal sensor were $2.10^{\circ}C$ (95% CI, 0.71-3.49) and $2.87^{\circ}C$ (1.13-4.43), respectively. Conversely, the skin temperature was not increased but rather decreased according to application of the cooling system. Conclusion: We observed mean $2.67^{\circ}C$ and $2.87^{\circ}C$ increases in temperature at the liver and peritoneal cavity, respectively, during hyperthermia. In vivo real-time thermometry is useful for directly measuring internal temperature during hyperthermia.

DEVELOPMENT OF THE MECHANICAL STRUCTURE OF THE MIRIS SOC (MIRIS 우주관측카메라의 기계부 개발)

  • Moon, B.K.;Jeong, W.S.;Cha, S.M.;Ree, C.H.;Park, S.J.;Lee, D.H.;Yuk, I.S.;Park, Y.S.;Park, J.H.;Nam, U.W.;Matsumoto, Toshio;Yoshida, Seiji;Yang, S.C.;Lee, S.H.;Rhee, S.W.;Han, W.
    • Publications of The Korean Astronomical Society
    • /
    • v.24 no.1
    • /
    • pp.53-64
    • /
    • 2009
  • MIRIS is the main payload of the STSAT-3 (Science and Technology Satellite 3) and the first infrared space telescope for astronomical observation in Korea. MIRIS space observation camera (SOC) covers the observation wavelength from $0.9{\mu}m$ to $2.0{\mu}m$ with a wide field of view $3.67^{\circ}\times3.67^{\circ}$. The PICNIC HgCdTe detector in a cold box is cooled down below 100K by a micro Stirling cooler of which cooling capacity is 220mW at 77K. MIRIS SOC adopts passive cooling technique to chill the telescope below 200 K by pointing to the deep space (3K). The cooling mechanism employs a radiator, a Winston cone baffle, a thermal shield, MLI (Multi Layer Insulation) of 30 layers, and GFRP (Glass Fiber Reinforced Plastic) pipe support in the system. Optomechanical analysis was made in order to estimate and compensate possible stresses from the thermal contraction of mounting parts at cryogenic temperatures. Finite Element Analysis (FEA) of mechanical structure was also conducted to ensure safety and stability in launching environments and in orbit. MIRIS SOC will mainly perform Galactic plane survey with narrow band filters (Pa $\alpha$ and Pa $\alpha$ continuum) and CIB (Cosmic Infrared Background) observation with wide band filters (I and H) driven by a cryogenic stepping motor.

MIRIS 우주관측카메라 FM Dewar 설계

  • Cha, Sang-Mok;Mun, Bong-Gon;Jeong, Ung-Seop;Lee, Dae-Hui;Nam, Uk-Won;Park, Yeong-Sik;Lee, Chang-Hui;Park, Seong-Jun;Lee, Deok-Haeng;Ga, Neung-Hyeon;Han, Won-Yong;Park, Jang-Hyeon;Seon, Gwang-Il;Yang, Sun-Cheol;Park, Jong-O;Lee, Seung-U;Lee, Hyung-Mok;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.40.2-40.2
    • /
    • 2010
  • MIRIS 우주관측카메라는 과학기술위성 3호의 주탑재체로서 $0.8{\sim}2.0{\mu}m$의 근적외선영역에서 우주배경복사와 우리은하 평면의 Pa-$\alpha$ survey 관측을 목적으로 한다. 이러한 임무를 수행하기 위해 MIRIS 우주관측카메라에는 MCT(HgCdTe) IR 검출기가 사용되고 6개의 필터를 장착할 수 있는 필터휠이 설계되었으며, 열잡음을 줄이고 원하는 SNR을 얻기 위해 모두 100K 이하로 냉각이 요구된다. 효과적인 냉각 및 저온유지를 위해서 외부의 열을 1차적으로 차단하는 Cryostat 외부용기와 100K 이하로 냉각되는 내부 Cold Box의 이중구조를 가지는 Dewar가 설계 되었다. 내부 Cold Box의 냉각은 소형 stirling cooler로 이루어지고 외부의 열 유입량이 Cooler의 냉각용량을 넘지 않도록 설계하였다. Cryostat 외부용기는 radiation cooling으로 냉각되어 200K 이하의 온도를 유지하며 내부 Cold Box로의 열유입을 최소화하기 위해 GFRP(Glass Fiber Reinforced Plastic) 단열 지지대와 MLI(Multi Layer Insulation)가 사용된다. 또한 100K으로 냉각시 필터고정부와 Cold Box 구조에서 일어날 수 있는 구조적인 피로도를 줄이고 열변형에 의한 문제를 방지하기 위한 고려가 설계에 포함되었다. FM(Flight Model)은 고진공 환경의 우주공간에서 문제가 발생하지 않도록 설계되었다. 또한 EQM 진동시험결과를 토대로 발사환경에서 발생하는 강한 진동을 견딜 수 있도록 FEM(Finite Elements Method) 구조해석을 통하여 필터고정부에 flexible structure 설계와 완충제를 추가하고 필터휠 구동부와 harness 고정부 및 cooler 지지부를 비롯한 전체 구조물에서 충분히 진동을 극복할 수 있도록 설계하였다.

  • PDF