• Title/Summary/Keyword: Glare

Search Result 208, Processing Time 0.028 seconds

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

Evaluation of Visual Performance for Implanted Aspheric Multifocal Intraocular Lens in the Cataract Patients (백내장 환자에서 비구면 다초점 인공수정체 삽입 후 시기능 평가)

  • Kim, Jae-Yoon;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.347-356
    • /
    • 2013
  • Purpose: To evaluate the visual acuity and visual performance after implantation of a aspheric multifocal (ReSTOR$^{(R)}$ SN6AD3) intraocular lens (IOL). Methods: Nineteen cataract patients (30 eyes) implanted with an aspheric multifocal IOL (ReSTOR$^{(R)}$ SN6AD3) either unilaterally or bilaterally were participated. Visual acuity (VA) and objective optical performance were evaluated at the time of preoperation, 1 week, 1 month, and 3 month after operation. At 3 month of post-operation, objective visual performance were measured and compared with the 38 eyes of 20 age-matched normal control. Distance VA was measured by using the ETDRS LCD chart and intermediate and near visual acuity were measured using Jaeger chart. Objective visual performance was assessed preoperatively and 1 week, 1 month and 3 month postoperatively using a double-pass system (Optical Quality Analysis System) with a 4-mm pupil diameter, the OSI (objective scatter index), MTF (modulation transfer function) cut off and strehl ratio. At 3 month of post-operation, visual acuity and visual performance compared with age matched normal control. Results: The uncorrected distance VA, OSI, MTF cut off and strehl ratio were significantly improved (p<0.05) until 1 month postoperatively. Visual performance of MTF cut off and strehl ratio after 3 month of operation were significantly improved compared to the normal control (p=0.063, p=0.103 respectively), however, OSI was higher than normal control. Patients implanted with aspheric multifocal IOL were satisfied with distance and near VA however, were unsatisfied with intermediate VA and reported glare and halos. Conclusions: The visual performance reaches to a stable condition in 1 month of implantation of aspheric multifocal IOL and improved to the level of age-mated normal patients. Also patients were satisfied with their quality of vision, however, intermediate VA, glare and halos were reported as complications.

Color Correction Method for High Dynamic Range Image Using Dynamic Cone Response Function (동적 원추 세포 응답을 이용한 높은 동적 폭을 갖는 영상 색상 보정 방법)

  • Choi, Ho-Hyoung;Yun, Byoung-Ju
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.104-112
    • /
    • 2012
  • Recently, the HDR imaging technique that mimics human eye is incorporated with LCD/LED display devices to deal with mismatch between the real world scene and the displayed image. However, HDR image has a veiling glare limit as well as a scale of the local contrast problem. In order to overcome these problems, several color correction methods, CSR(center/surround Retinex), MSR (Multi-Scale Retinex), tone-mapping method, iCAM06 and so on, are proposed. However, these methods have a dominated color throughout the entire resulting image after performing color correction. Accordingly, this paper presents a new color correction method using dynamic cone response function. The proposed color correction method consists of tone-mapping and dynamic cone response. The tone-mapping is obtained by using a linear interpolation between chromatic and achromatic. Thereafter, the resulting image is processed through the dynamic cone response function, which estimates the dynamic responses of human visual system as well as deals with mismatch between the real scene image and the rendered image. The experiment results show that the proposed method yields better performance of color correction over the conventional methods.

Light Pollution Survey of Outdoor Lighting in Shopping Complex (쇼핑용 복합빌딩의 옥외조명으로 인한 광공해발생 실태조사)

  • Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.16-26
    • /
    • 2004
  • As the importance of outdoor lighting become more widely recognized, outdoor lighting has been installed in many buildings, plazas, landscape, and historical monuments in Korea, Outdoor lighting on showing complex, in particular, express its values as local landmarks. However, the excessive outdoor lighting in the large-scale shopping complex tends to cause light pollution. Many advanced countries are trying to create a comfortable lighting environment by the guidlines and regulations on outdoor lighting to prevent light pollution. For this research backgrounds, the light pollution of three showing complexes in Seoul have been investigated. For the purpose, luminance of building facade, horizontal illuminance, and vertical illuminance were measured with proper measurement instruments and compared the results with the CIE recommendations. The results of the study are as follows. As no cut-off luminaries are currently installed on pedestrian walks, some glare were occured partially. It also shows that the luminance of building facades are high to improve the degree of public awareness of buildings and advertisements. In other words, the luminance of the building facade, when compared with that of the CIE recommendations, is twice as high and the vatical illuminance of pedestrian walks is far higher than that of the CIE recommendations, which proves the existence of light pollution. As Korea has not yet provided proper regulations or guidelines for the control of light pollution, it is necessary to make appropriate codes for it.

Fabrication and densification of Heusler Fe2VAl alloy powders by mechanical alloying (MA법에 의한 Heusler Fe2VAl 합금분말의 제조 및 치밀화)

  • Kim, Kwang-Duk;Lee, Chung-Hyo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.23 no.1
    • /
    • pp.51-57
    • /
    • 2013
  • We have applied mechanical alloying (MA) to produce Heusler $Fe_2VAl$ thermoelectric alloy using a mixture of elemental $Fe_{50}V_{25}Al_{25}$ powders. An optimal milling and heat treatment conditions to obtain the single phase of Fe2VAl compound with fine microstructure were investigated by X-ray diffraction and differential scanning calorimetry (DSC) measurement. The $Fe_{50}V_{25}Al_{25}$ MA sample ball-milled for 60 hours exhibits a bcc ${\alpha}$-(Fe,V,Al) solid solution. Single phase of Heusler $Fe_2VAl$ compound can be obtained by MA of $Fe_{50}V_{25}Al_{25}$ mixture for 60 hours and subsequently heated up to $700^{\circ}C$. Sintering of the MA powders was performed in a spark plasma sintering (SPS) machine using graphite dies at $900{\sim}1000^{\circ}C$ under 60 MPa. The Vickers hardness of bulk sample sintered at $1000^{\circ}C$ was high value of Hv 870. All compact bodies have a high relative density above 90 % with metallic glare on the surface.

Synthesis and characterization of Mg-Si thermoelectric compound subjected to mechanical alloying (기계적 합금화에 의한 Mg-Si계 열전화합물의 합성 및 평가)

  • Lee, Chung-Hyo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.17 no.3
    • /
    • pp.121-127
    • /
    • 2007
  • We have applied mechanical alloying (MA) to get $Mg_2Si$ thermoelectric material with nano-sized grains. An optimal milling and heat treatment conditions to obtain the single phase of $Mg_2Si$ compound with fine microstructure were investigated by X-ray diffraction and differential scanning calorimetry (DSC) measurement. The $Mg_{66.7}Si_{33.3}$ MA samples ball-milled for $20{\sim}180\;hrs$ exhibit two broad exothermic heat releases around $220^{\circ}C$ and $570^{\circ}C$. On the other hand, MA sample ball-milled far 260 hrs exhibits only a sharp exothermic peak at $230^{\circ}C$ Single phase Mg2Si powder can be obtained by MA of $Mg_{66.7}Si_{33.3}$ mixture for 60 hours and subsequently heated up to $620^{\circ}C$. Sintering of the MA powders was performed in a spark plasma sintering (SPS) machine using graphite dies at $800{\sim}900^{\circ}C$ under 50 MPa. The shrinkage of sintering sample during SPS was significant at about $200^{\circ}C$. All compact bodies have a high relative density above 94% with metallic glare on the surface.

Vision and Aging

  • Kim, In Suk;Hilz, Rudolf
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.9-13
    • /
    • 2002
  • It is well known that the maximum amplitude of accommodation decreases with increasing age.(Presbyopia). With single vision lenses presbyopia can be corrected only for one viewing distance. With progressive power lenses presbyopia can be corrected for all viewing distances. But there are some other changes in the visual system with age which can not be corrected by spectacle lenses. Pupillary diameter decreases and the light transmission of the ocular media decreases. Therefore old people need more light, they need better illumination. Cone density in the retina decreases, this is only one example for changes in the sensory system. These changes in the visual system cause changes in visual functions. At the age of 80 visual acuity has decreased to half. Contrast sensitivity for gratings decreases mainly for high spatial frequencies very important is the increase of stray light in the ocular media and therefore the increase of glare. Veiling luminance increases by a multiple of approximately 4, Dark adaptation gets slower and light sensitivity is approximately 2 log units (factor 100) less when the eye is completely dark adapted. Also colour vision gets worse, especially at low luminances. Elderly people have problems with visual tasks which require divided attention between foveal and peripheral vision. An example is the measurement of the useful field of view. This useful field of view be expanded (improved) by visual training.

  • PDF

Fatigue Subjective Symptoms and Risk Factors in Bank Workers with VDT (VDT작업 은행원들의 피로자각증상 조사)

  • Lee, Kyung-Jae;Kim, Joo-Ja
    • Journal of Preventive Medicine and Public Health
    • /
    • v.38 no.1
    • /
    • pp.45-52
    • /
    • 2005
  • Objectives : To investigate the fatigue subjective symptoms and VDT related risk factors in bank workers. Methods : A total of 2178 workers (62.8% male, 37.2% female) were surveyed with a self-administered and structured questionnaire consisting of 30 fatigue symptoms and other VDT related factors regarding work characteristics, work postures, work environments, personal medical histories, etc. Fatigue subjective symptoms were divided into 3 groups of 10 questions each: a dull, drowsy and exhausted feeling (Group I), a mental decline of working motivation (Group II), or a feeling of incongruity in the body and dysfunction of autonomic nervous system (Group III). Each question was weighted as 0 for 'none', 1 for 'sometimes', and 2 for 'always'. Results : Mean age was $35.8{\pm}7.2$ years ($38.9{\pm}6.0$ in males, $30.6{\pm}5.8$ in females), Mean work duration was $7.7{\pm}7.1$ years ($8.4{\pm}7.4$ in males, $6.5{\pm}6.4$ in females). Mean symptom score in males was $11.0{\pm}8.1$ ($4.9{\pm}3.1$ in Group I, $3.0{\pm}3.1$ in Group II, $3.1{\pm}2.8$ in Group III) and in females was $17.5{\pm}9.5$ ($7.0{\pm}3.8$ in Group I, $4.6{\pm}3.5$ in Group II, $5.9{\pm}3.4$ in Group III). Mean scores were higher in the order of Group I>III>II. Females had significantly higher scores than males in all three groups (p<0.001). Most common symptoms complained of as 'always' or 'sometimes' were feel strained in the eyes' (85.4%) among Group I, 'find difficulty in thinking'(54.2%) among Group II, and 'feel stiff in the shoulders (72.3%) among Group III. In multiple regression analysis, female, non-straight spine at workstation, more VDT work hours, history of physical therapy, glare of screen, overtime work, young age, and non-horizontal elbow position were significantly related with high score of symptoms. Conclusions : More supportive VDT work environment and education for correct work postures for VDT workers are recommended.

Effects of Thermal Properties and Water Retention Characteristics of Permeable Concrete Pavement on Surface Temperature (투.보수성 시멘트 콘크리트 포장의 열물성 및 수분보유특성이 표면온도에 미치는 영향)

  • Ryu Nam-Hyang;Yoo Byung-Rim
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.1 s.114
    • /
    • pp.21-36
    • /
    • 2006
  • This study was undertaken to analyze the effects of pavement thermal properties and water retention characteristics on the surface temperature of the gray permeable cement concrete pavement during the summer. Following is a summary of major results. 1) The hourly surface temperature of pavement could be well predicted with a heat transfer model program that incorporated the input data of major meteorological variables including solar radiation, atmospheric temperature, dew point, wind velocity, cloudiness and the evaporation rate of the pavements predicted by the time domain reflectometry (TDR) method. 2) When the albedo was changed to 0.5 from an arbitrary starting condition of 0.3, holding other variables constant, the peak surface temperature of the pavement dropped by 11.5%. When heat capacity was changed to $2.5\;kJm^{-3}K^{-1}\;from\;1.5\;kJm^{-3}K^{-1}$, surface temperature dropped by 8.0%. When daily evaporation was changed to 1 mm from 2 mm, temperature dropped by 5.7%. When heat conductivity was changed to $2.5\;Wm^{-1}K^{-1}\;from\;1.5\;Wm^{-1}K^{-1}$, the peak surface temperature of the pavement fell by 1.2%. The peak pavement surface temperature under the arbitrary basic condition was $24.46^{\circ}C$ (12 a.m.). 3) It accordingly became evident that the pavement surface temperature can be most effectively lowered by using materials with a high albedo, a high heat capacity or a high evaporation at the pavement surface. The glare situation, however, is intensified by raising of the albedo, moreover if reflected light is absorbed into surrounding physical masses, it is changed into heat. It accordingly became evident that raising the heat capacity and the evaporative capacity may be the moot acceptable measures to improve the thermal characteristics of the pavement. 4) The sensitivity of the surface temperature to major meteorological variables was as follows. When the daily average temperature changed to $0^{\circ}C\;from\;15^{\circ}C$, holding all other variables constant, the peak surface temperature of the pavement decreased by 56.1 %. When the global solar radiation changed to $200\;Wm^{-2}\;from\;600\;Wm^{-2}$, the temperature of the pavement decreased by 23.4%. When the wind velocity changed to $8\;ms^{-1}\;from\;4\;ms^{-1}$, the temperature decreased by 1.4%. When the cloudiness level changed to 1.0 from 0.5, the peak surface temperature decreased by 0.7%. The peak pavement surface temperature under the arbitrary basic conditions was $24.46^{\circ}C$ (12 a.m.)

Study of the Effect of the Transmittance of a Diffuser Plate on the Optical Characteristics of High-power Quantum-dot Illumination (확산판의 투과율이 고출력 양자점 조명의 광특성에 미치는 영향에 대한 연구)

  • Kim, Hye-Rin;You, Dong Geun;You, Jae Hwan;Jang, Jun Won;Choi, Moo Kyu;Hong, Seung Chan;Ko, Jae-Hyeon;Joe, Sung-Yoon;Kim, Yongduk;Park, Taehee;Ko, Young Wook
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.5
    • /
    • pp.220-229
    • /
    • 2021
  • The optical characteristics of high-power direct-lit white light-emitting diode (LED) lighting were investigated, where a quantum dot (QD) film was adopted to enhance the color-rendering index (CRI). The transmittance of the diffuser plate and the concentration of the QD film were varied in this study. The color coordinates and the correlated color temperature (CCT) did not show any appreciable change, while the CRI values increased slightly as the transmittance of the diffuser plate decreased. The investigated optical properties were nearly independent of the viewing angle, and the luminance distribution was close to Lambertian. The CCT decreased from approximately 6000 K to approximately 4000 K as the concentration of the QD film increased from 0 to 7.5 wt%, which was due to the enhanced red component in the emission spectrum. The CRI increased to approximately 95 for some optical configurations of the lighting. These results demonstrate that glare-free, color-changeable, high-rendering LED lighting can be realized by using a combination of a diffuser plate of appropriate transmittance and a red QD film.