• 제목/요약/키워드: Geothermal heatpump system

검색결과 14건 처리시간 0.025초

공동주택용 지열냉난방 적용성 검토 연구 (A Study on Application of Geothermal Heatpump System for Apartments)

  • 백성권;안형준;이동철;임성균
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.574-578
    • /
    • 2009
  • Residential is the biggest market for geothermal heatpump systems in the world. However It could not be considered as a big market in Korea. Serious problems are hidden. In this paper, I will discuss about with other problems that we must solve.

  • PDF

사무용건물에서 지열히트펌프냉난방시스템의 운전성능 평가 (Performance for Geothermal Heating & Cooling System by Heatpump in Office Building)

  • 안형준;백성권;조정식;손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제3권1호
    • /
    • pp.23-29
    • /
    • 2007
  • For the perfomance test of geothermal system, a large pilot of capacity of 50RT is built and operated in office building. This system is planed hybrid system with cooling tower as asisstance heat sink. From October, 2004 to September, 2005, this system is operated andmonitored. As the result, COP of heating periods is about 3.46 and COP of cooling periods is about 4.1. Therefore, geothermal system is useful and suitable in Korea.

  • PDF

상수도열원과 지열원을 이용한 동절기 지열히트펌프 성능평가에 대한 연구 (A Study on performance of geothermal heatpump using domestic supply water source and geothermal source during winter)

  • 이병두;이세진;이대우
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.194.1-194.1
    • /
    • 2011
  • 본 연구에서는 지열히트펌프 시스템의 열원으로써 지열이외에 건축물의 미활용 에너지라고 할 수 있는 상수도의 에너지를 활용하여 지중열교환기의 천공길이를 줄이는 것이 주요 목적이며, 또한 건물의 미활용에너지를 냉난방에너지원으로써 이용 가능한 것을 보여주는 것에 있다. 실험은 4인 가족기준으로 3RT 용량의 히트펌프를 설치하고 인당 평균 177 liter/day 기준으로 하루에 약 710 liter/day의 물을 사용하는 것으로 가정하였다(환경부 2007년 상수도 통계값). 시간당 가정내에서 사용하는 물량은 일정하지 않아 일일 8시간 사용하는 것으로 하여 약 1.5 LPM 으로 실험하였다. 저수조의 크기 및 지열 히트펌프의 열원으로써 사용가능한 열량을 계산하기 위해 CFD 시물레이션을 수행하였다. CFD의 결과 상수도를 급수하기 위한 저수조의 크기는 $2m^3$로 결정하였으며 이때 열원으로써 사용가능한 열량은 약 0.7RT였다. 48시간의 실험기간 동안 저수조를 통해 얻은 열원은 0.6RT 였으며 100m의 지중열교환기를 통해 얻은 열원은 2RT 였다. 히트펌프 자체의 난방 COP는 평균 4.2를 나타내었으며 펌프등의 소비전력을 포함한 System COP는 4.0 나타내었다. 이번 연구를 통해 건물의 미활용에너지인 저수조의 물을 이용하여 지열히트펌프의 열원으로써 이용 가능하며 기존의 지열히트펌프 시스템대비 천공길이 단축, 시공비 저감이 가능한 것을 볼 수 있었다.

  • PDF

고성능저가형 지중열교환기 개발연구 (Development of High Peformance Geothermal heatexchanger)

  • 안형준;백성권;임성균
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.470-473
    • /
    • 2007
  • Geothermal heat exchanger(GHEX) is a major component of Geothermal heat pump system(GSHPs). In Common, We use the vertical type GHEX in Korea. But vertical type GHEX needs a high cost for installation, because of drilling the hole which has 200m depth at max. So, We suggest the use of horizontal type GHEX. When we construct buildins, We excavate the ground and we can install the horizontal type GHEX at the excavated underground. It's very cheap and convenient method compare to vertical type GHEX installation. This study is peformed to estimate the peformance of horizontal type GHEX and to analyze effects of heat exchanger types and undergroundwater. As the result, slinky type GHEX has a 66% efficiency compare to vertical type GHEX and mat type has a 201% efficiency at the undergroundwater zone.

  • PDF

R452B 냉매 적용 물대물 지열원 히트펌프 유닛의 냉난방 운전 성능 특성 (Heating and Cooling Performance Characteristics of a Water-to-Water Heat Pump with R452B Refrigerant)

  • 최연성;강희정;김은오
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권4호
    • /
    • pp.14-20
    • /
    • 2017
  • Refrigerant having high global warming potentials will be phased out due to environmental protection issues. R410A has been widely used in geothermal heat pump. However, it has a little high GWP by 2088 value. One of the recommended substitute for R410A refrigerant is R452B which having a GWP by 698 value. In this paper, the heating and cooling performance of the water-to-water geothermal heat pump unit with R452B was experimentally investigated. The performance of the heat pump adopting R452B was also compared with the system applying R410A. The heating and cooling capacity of R452B heat pump system showed a slightly lower values within 2% comparing with R410A system. However, the R452B system's coefficient of performance was enhanced by 5.2% and 13.7% at heating and cooling mode, respectively.

건물일체형 지열히트펌프시스템의 난방 성능 분석 (Heating Performance Analysis of Building Integrated Geothermal System)

  • 김상진;이진욱;김태연;이승복
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.206-210
    • /
    • 2012
  • Ground source heat pump is a central heating and cooling system that pumps heat to or from the ground. Building Integrated Geothermal system used in this experiment is one of the Ground Source Heat Pump Systems which utilize energy pile. The purpose of this study is to evaluate heating performance of the system. The building is a low-energy experiment apartment in Yonsei University Songdo Campus and the subject is one of the energy reduced houses in this apartment. In the experiment, indoor temperature, outdoor temperature and the inlet and outlet temperature of ground heat exchanger and subject model, were measured. Then the heat pump's Coefficient of performance(COP) of the heat pump was calculated. As a result, the COP of heat pump is 4-5. Although the depth of the ground heat exchanger in this experiment is shallower than usual heat exchanger, the result of heating performance of this system was good as well.

  • PDF

공동주택에서 에너지 파일을 이용한 지열히트펌프 시스템의 성능 분석 (Performance Evaluation of Ground Source Heat Pump System Utilizing Energy Pile in Apartment)

  • 이진욱;김태연;이승복
    • KIEAE Journal
    • /
    • 제12권4호
    • /
    • pp.41-46
    • /
    • 2012
  • In Korea, Apartment houses recently occupy over 80% of all buildings. Ground source system has to be designed to consider feature of apartment house. Most apartment houses use PHC pile to get a bearing power of the soil. Therefore, the purpose of this study is to evaluate performance of ground source heat pump system utilizing energy pile under apartment. Object of experiment is low-energy experiment apartment in Song-do and Energy Pile are applied to 80%, 100% energy reduction model for heat-source. First, performance evaluation of Energy Pile geothermal system was done during summer season. As a result, The COP(coefficient of performance) about geothermal heatpump was approximately 5-6 while cooling. In winter season, Long experiment was performed because it was very important to evaluate ground condition for long time. During heating experiment, Indoor room set temperature was $20^{\circ}C$ and kept constant by heating. Coefficient of performance for heat pump and overall system was calculated. It was 3.5-4.5 for COP and 2.5-3.7 for system COP.