• Title/Summary/Keyword: Geothermal heat pumps

Search Result 57, Processing Time 0.02 seconds

Renewable Energy Production by Heat Pump as Renewable Energy Equipment (신재생에너지 기기로서 히트펌프의 신재생에너지 생산량)

  • Hong, Hiki;Choi, Junyoung;Im, Shin Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.10
    • /
    • pp.551-557
    • /
    • 2017
  • Most European economies, Japan, and many governments have made it a major policy to expand the green business by disseminating heat pump technology, which has a large $CO_2$ reduction effect. The heat pump of all heat sources has been recognized as renewable energy and the policy to encourage has been implemented. In the recently revised Renewable Energy Law, the hydrothermal source (surface sea water) heat pump was newly included in renewable energy. In addition, the scope of application of heat pumps has expanded in the mandatory installation of renewable energy for new buildings, remodeling buildings, and reconstructed buildings based on this law. However application to heat pumps using all natural energy as heat source has been put off. In this revision, the ratio of renewable energy to the total energy produced by the heat pump was fixed at 73%, which depends on coefficient of performance of heat pump. The ratio of renewable energy is $1-1.8/COP_H$, and should be calculated including the coefficient of performance of the heat pump. Using a high efficiency heat pump or a high-temperature heat source increases the coefficient of performance and also reduces $CO_2$ emissions. It is necessary to expand the application of heat pumps as renewable energy equipment and to improve the correct calculation of renewable energy production.

An Introduction to Regulations on Underground Injection Wells: A Case in Missouri (지하 유체주입 지하수 관정의 설치 및 허가에 관한 규정: 미국 미주리주)

  • Lee Jin-Yong
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.5
    • /
    • pp.70-76
    • /
    • 2005
  • It is expected that use of groundwater wells for contaminated groundwater remediation, artificial groundwater recharge and geothermal heat pump systems is increasing in the future in Korea. Some practical confusions may be produced due to lack of regulations related to permits and registrations of these types of wells. This short note is intended to draw attention of relevant professionals by shortly introducing some relevant code of state regulations in Missouri, USA.

Cooling Performance Evaluation study of Dual-Source Heat Pump System (2중열원 히트펌프시스템의 냉방성능예측에 관한 연구)

  • Noh, Kwan-Jong;Kim, Ji-Young;Kang, Eun-Chul;Park, Hye-Moon;Lee, Euy-Joon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.3 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • A steady-state simulation model for Dual-Source Heat Pump(DSHP) of 8RT was presented. A Dual-Source Heat Pump(DSHP) has been designed to make up for the conventional air source heat pumps. The performance evaluation has been conducted under internal standard test conditions such as ISO-13256-1 and KS C 9306. However, as test conditions such as entering water, indoor and outdoor air conditions could not be controlled to satisfy the standard test conditions in outdoor tests, a series of experiments have been conducted with the actual test conditions. Then, computer models for DSHP could be used for the standard condition have developed using EES program. The model was developed from basic thermodynamic principles and heat transfer relations. Most of the parameters were obtained with EES from the actual catalog data. The simulation results were in good agreement with the experiments.

  • PDF

Study on the Performance of a Cascade Heat Pump with Two-stage Water Heating Process (2단 승온 캐스케이드 히트펌프의 성능 특성에 관한 연구)

  • Jang, Hanbyeoul;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.4
    • /
    • pp.27-32
    • /
    • 2016
  • It is estimated that only heating and cooling take about one third of the total energy consumption worldwide. However, the conventional heating and cooling systems have low efficiencies. Also, boilers and electric heaters that are mostly used to generate both domestic and industrial hot water are inefficient and high energy consumers. For this reason, cascade heat pumps which are known to be very energy efficient and have less environmental impact are being promoted to replace conventional heating, cooling and hot water systems. In this study, a newly designed cascade heat pump by two-stage water heating method has been experimentally investigated. By adopting the auxiliary heat exchanger, the performance of the system was increased. The performance enhancement rate of the system could be maximized by adjusting the low stage compressor speed rather than the high stage compressor speed. The performance of the system with the auxiliary heat exchanger was enhanced by 16.5%.

Time Series Analysis of the Effect of Ground-source Heat Pumps on Groundwater Characteristics (시계열 분석을 이용한 지열히트펌프 가동에 따른 지하수특성변화 해석)

  • Mok, Jong-Gu;Lim, Hong-Gyun;Jang, Bum-Ju;Park, Yu-Chul;Lee, Jin-Yong
    • The Journal of Engineering Geology
    • /
    • v.21 no.1
    • /
    • pp.35-43
    • /
    • 2011
  • Time series analysis was applied to groundwater level, water temperature, and electrical conductivity data obtained from monitoring wells around ground-source heat pumps at Sangji University of Wonju (standing column well type) and at Jungwon University of Goesan (closed loop type), from 21 May to 12 October 2010. We found large temporal variations in the characteristics of groundwater at Wonju, but only minor variations at Goesan. These results may improve our understanding of the effects of ground-source heat pumps on the characteristics of surrounding groundwater, according to the installation method for the pumps.

Development of a Renewable Energy Facility Design and Its Simulation Case Study (신재생에너지 설비 설계방안 개발 및 시뮬레이션 사례 연구)

  • Shin, Younggy;Kim, Eun Joo;Kim, Tae Hyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.8
    • /
    • pp.464-470
    • /
    • 2013
  • Economic feasibility was conducted regarding the regulation that dictates obligatory installation of renewable energy facilities in small proportion. A concern is how to allocate the capacities of candidate facilities (solar collectors, PV cells and geothermal heat pumps) with minimum cost, and meet the obligatory energy supply proportion. A design rule has been developed, with which a designer can tune his or her design strategy between installation cost and LCC. This was derived mainly from documents regarding the KEMCO installation guide. It was concluded that PV was the cheapest, with respect to installation cost, but a geothermal heat pump was the most recommended, when LCC was also taken into account. The proposed design result was also confirmed, by simulation results obtained from Energy Plus.

Evaluation of Ground Temperature and Soil Thermal Diffusivity Using the Soil Temperature Data of KMA (기상청 지중 온도 데이터를 이용한 지중 온도 및 토양 열확산계수 산정)

  • Sohn, Byong-Hu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.7 no.1
    • /
    • pp.1-9
    • /
    • 2011
  • Storing and transferring heat in soils is governed by the soil thermal properties and these properties are therefore needed in many engineering applications, including horizontal ground heat exchanger for ground-coupled heat pumps. This paper presents the evaluation results of the ground subsurface temperature and apparent thermal diffusivity of soils by using ground temperature data collected at the depths of 0.5 m, 1.0 m, 1.5 m, 3.0 m, and 5.0 m at four sites. The existing correlation assuming that the soil was homogeneous and of constant thermal diffusivity was applied to calculate the subsurface temperature and two analytical equations, amplitude and phase equation, were also used to evaluate the soil apparent thermal diffusivity. Comparison of the estimated and of the measured values of the subsurface temperature has shown that the empirical correlation predicts quite accurately the ground temperature at various depths. Based on the one-dimensional heat conduction equation, the apparent thermal diffusivity can be estimated by the two equations.

A Review on Potential Effects of Installation and Operation of Ground Source Heat Pumps on Soil and Groundwater Environment (지열히트펌프시스템의 설치 및 운영이 토양.지하수에 미치는 영향에 대한 고찰)

  • Jo, Yun-Ju;Lee, Jin-Yong;Lim, Soo-Young;Hong, Gyeong-Pyo
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.3
    • /
    • pp.22-31
    • /
    • 2009
  • Recently use of renewable energies such as geothermal energy for space heating and cooling is increasing in Korea due to energy crisis and global warming. Ground source heat pump (GSHP) is known as one of the most environment-friendly HVAC (heating, ventilation and air-conditioning) systems in the world. However, some potential effects caused installation and operation of the GSHP systems on soil and groundwater environment are reported. The potential effects are closely related with inappropriate installation, operation and closure of the GSHP systems. In this paper, possible effects of the GSHPs on soil and groundwater environments are reviewed.

Case Study of Building Heating and Cooling using Photovoltaic Power and Geothermal Heat Pumps (태양광 및 지열히트펌프를 적용한 건물냉난방 사례)

  • Kim, Jin-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1693-1695
    • /
    • 2005
  • 최근 공공건물에 신재생에너지 적용이 의무화되었고, 기후변화협약의 발효로 이산화탄소배출 절감에 대한 관심이 매우 높다. 가장 효율이 높은 냉난방 시스템인 지열히트펌프를 대표적인 신재생에너지인 태양광발전을 이용하여 구동하여 건물을 냉난방을 수행하도록 적용되었다. 야간 또는 태양에너지 밀도가 낮은 날을 위하여 축열과 축냉을 할 수 있는 수축열시스템과 연계하여 적용되었다. 지열히트펌프는 도심지역의 열섬현상 해소에 기여할 수 있으며, 외기 온도의 변화에 관계없이 쾌적한 실내환경을 유지할 수 있으며 향후에 그린 빌딩인증등을 위해 에너지 절약과 신재생에너지 사용량을 높일 수 있는 방안으로 판단된다. 이를 적용한 설치 사례에 대한 사양과 운전 조건이 제시된다.

  • PDF

Verification experiment of a ground source multi-heat pump at cooling mode (지열원 시스템 히트펌프의 냉방 성능 특성에 관한 실증 연구)

  • Lim, Hyo-Jae;Kang, Shin-Hyung;Choi, Jae-Ho;Choi, Jong-Min;Moon, Je-Myung;Kwon, Young-Seok;Kwon, Hyung-Jin;Kim, Rock-Hee
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.21-26
    • /
    • 2008
  • Recently, small and medium-sized buildings have employed a multi-heat pump. The major benefits of the multi-heat pump over a conventional system are that it is easier system to maintain along with a diversification of facility use, and high comfortability. The performance of multi-heat pump systems can be enhanced by using geothermal energy instead of air source energy. This paper describes the multi-heat pumps applied in an ground source heat pump system for an actual building. The performance of a ground source multi-heat pump installed in the field was investigated in cooling mode. The maximum COP of the systems with single U-tube and double tube ground loop heat exchangers were 6.6 and 6.0, respectively. It is suggested that the new algorithms to control the flow rate of secondary fluid for ground loop heat exchanger have to be developed in order to enhance the performance of the system.

  • PDF