• 제목/요약/키워드: Geothermal heat pump

검색결과 339건 처리시간 0.028초

지열히트펌프 시스템의 건물통합설계 및 커미셔닝에 관한 연구 (A Study on Building Integrated Design and Commissioning of GHP System)

  • 김지영;장재철;강은철;장기창;이의준
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.169.1-169.1
    • /
    • 2010
  • Geothermal heat pump(GHP)system has been extensively disseminated due to the recent increasing demand over new and renewable energy. However, the economics and system reliability has been key issues and barriers to insure a better system performance as designed originally. The building integrated designs of geothermal heat pump system are test and optimize GHP system by evaluating its performance in virtual reality. System design is an iterative process that will help optimize the cost efficiency of the system. One of the primary goals is to minimize the energy imbalance between the amount of energy extracted from the ground and the energy reject to it. This will reduce the land area required to install the GHX, reduce the cost of installing it and ensure the long-term efficiency of the system. Commissioning is the process of ensuring that are designed, installed, functionally tested, and capable of being operated and maintained to performance in conformity with design intent. In this paper, Study on introduction of Initial commissioning method of Geothermal Heat Pump(GHP) system using ISO performance data has been introduced. Also KIER GHP Simulator is used to simulate actual heat pimp operating condition and test commissioning method. Result should that the experiment data base could verify the applicability of the commissioning method, and also were able to suggest a better ways to GHP commissioning.

  • PDF

지열-열펌프 시스템의 온실냉방 및 육묘 효과 (Effect of Greenhouse Cooling and Transplant Quality Using Geothermal Heat Pump System)

  • 이재한;이용범;권준국;강남준;김학주;최영하;박진면;이한철
    • 생물환경조절학회지
    • /
    • 제15권3호
    • /
    • pp.211-216
    • /
    • 2006
  • 지열을 이용한 열펌프 시스템이 온실의 냉방과 과채류의 묘소질에 미치는 영향을 구명하였다. 온실 내 기온은 주간에는 차광구에 비해서 포그+차광구가 $3{\sim}4^{\circ}C$ 낮았고, 야간에는 지열-펌프+차광구가 차광 및 포그+차광구에 비해 $5{\sim}7^{\circ}C$ 낮았다. 오이, 고추 및 토마토 묘의 초장은 차광이나 차광+포그구에 비해 지열-열펌프+차광구가 가장 짧았고, 엽면적과 건물중은 지열-열펌프+차광구가 다른 처리에 비해 약간 작았다. 결과적으로 건묘지수는 지열을 이용하여 냉방을 한 지열+차광구는 포그+차광구 및 차광구에 비해 모두 높게 나타났다.

시뮬레이션을 통한 지열 히트펌프 시스템과 VRF 시스템의 에너지 성능비교 (Comparison of Energy Performance between Ground-Source Heat Pump System and Variable Refrigerant Flow(VRF) Systems using Simulation)

  • 손병후;임효재;강성재
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권3호
    • /
    • pp.30-40
    • /
    • 2021
  • This paper compares the annual energy performance of four different types of air-conditioning systems in a medium-sized office building. Chiller and boiler, air-cooled VRF, ground-source VRF, and ground-source heat pump systems were selected as the systems to be compared. Specifically, the energy performance of the GSHP system and the ground-source VRF system were compared with each other and also with conventional HVAC systems including the chiller and boiler system and air-cooled VRF system. In order to evaluate and compare the energy performances of four systems for the office building, EnergyPlus, a whole-building energy simulation program, was used. The EnergyPlus simulation results show that both the GSHP and the ground-source VRF systems not only save more energy than the other two systems but also significantly reduce the electric peak demand. These make the GSHP and the VRF systems more desirable energy-efficient HVAC technologies for the utility companies and their clients. It is necessary to analyze the impact of partial load performance of ground-source heat pump and ground-source VRF on the long-term (more than 20 years) performance of ground heat exchangers and entire systems.

지하수 열원 열펌프 개발을 위한 지하수 온도의 변화 특성 연구 (A Study on the Variation of Ground Water Temperature for Development of Ground Water Source Heat Pump)

  • 남현규;김영일;서정아;신영기
    • 한국지열·수열에너지학회논문집
    • /
    • 제1권2호
    • /
    • pp.1-6
    • /
    • 2005
  • Ground water source heat pumps are clean, energy-efficient and environment-friendly systems for cooling and heating. Although the initial cost of ground water source heat pump system is higher than that of air source, it is now widely accepted as an economical system since the installation cost can be returned within a short period of time due to its high efficiency. In a ground water source heat pump system, the variation of the ground water temperature is an important factor that influences the system performance. In this study, variation of the ground water temperature of a single well system is studied experimentally for various operating conditions. When ground water flow exists in the underground, the returned water exchanges heat efficiently with the ground and the temperature of the ground water remains nearly constant. Hence the short circuit problem is minimized. If an active flow of ground water flow exists in the underground, a singe well heat pumps system will be free of short circuit problem and can operate with high performance.

  • PDF

우물관정형(SCW공법) 지열히트펌프 시스템의 설치 및 운영사례 (A Case Study on the Installation and Operation of the Standing Column Well Method)

  • 나상민;박시삼;박종헌;이건중;김태원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.592-595
    • /
    • 2009
  • In recent years, geothermal heat pump (GHP) systems have become increasingly popular for heating and cooling in buildings. The Standing Column Well (SCW) method is one of the most efficient GHP system. Because it use groundwater for heat transfer material. In SCW systems, water is re-circulated between the well and the building (heat pump). It is only a short time since this method has been applied in domestic. So we have to refer to the developed countries' guides and manuals of SCW. In this paper, several design and construction points of SCW method are filed. We used real operation data of SCW system at Chong-Ju Univ. site for economical efficiency analysis. As a result, the payback period of Chong-Ju Univ. site is calculated at 7.23 years.

  • PDF

시스템 히트펌프의 압축기 주파수 및 전자팽창밸브 개도 변화에 따른 과도성능 특성 (Transient Performance of a System Heat Pump with the Variation of Compressor Speed and EEV Openings)

  • 이상혁;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제9권3호
    • /
    • pp.11-18
    • /
    • 2013
  • Small and medium-size buildings employ a multi-distributed individual air-conditioning system utilizing package air conditioners instead of centralized cooling systems, which can allow easier building management and maintenance along with a diversification of facility use. Inverter driven system heat pumps have been developed to achieve not only easy distribution control allowing free combination of indoor units with different models and different capacities, but also wide applications to an intelligent air conditioning. In this study, the transient performance of a system heat pump was analysed with the variation of compressor speed and EEV openings. The superheat was selected as a control parameter of the system, because the variation of it was consistent with each indoor unit capacity.

지열히트펌프 시스템의 EWT의 변화에 따른 냉방운전 특성에 관한 실험적 연구 (An Experimental Study on the Cooling Operation Characteristics for Different Entering Water Temperatures In Geothermal Heat Pump System)

  • 안병천;김재완
    • 한국지열·수열에너지학회논문집
    • /
    • 제6권1호
    • /
    • pp.1-7
    • /
    • 2010
  • In this paper, an experimental study on the cooling operation characteristics for different entering water temperatures in geothermal heat pump system are carried out by using Lab VIEW system program Set-point temperature controls for cooling water and supply air temperatures is applied to analyze the energy consumption and control performances. As a result, the system responses show that different entering water temperatures(EWT) effect greatly on the energy consumption and system COP.

지열원과 수열원을 이용한 하이브리드 히트펌프 시스템의 에너지 성능 비교 분석 연구 (A Study on Comparative Analysis of Energy Performance of Hybrid Heat Pump Systems Using Ground Heat Source and Water Heat Source)

  • 박시훈;김종현;민준기
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.59-67
    • /
    • 2021
  • In this study, the performance of the single heat source system and the hybrid system was comparatively analyzed. Case 1 is a ground heat source system, and Case 2 is a water heat source system. Case 3, a hybrid system, reduced the capacity of the ground heat source and applied a water heat source as an auxiliary heat source, and Case 4 was composed of a system that applied a water heat source as an auxiliary heat source to the ground heat source system. As a result of the simulation, in case 3, energy consumption was reduced by up to 2.67% compared to ground sources for cooling. In Case 4, COP was improved by up to 10.02% compared to ground sources during cooling, and EST was calculated to be 2.42℃ lower. During heating, 0.83% was improved compared to the water heat source. At this time, the EST was calculated to be 2.25℃ higher than the water heat source.

소규모 학교의 냉난방 및 신재생에너지복합시스템 적용방안에 관한 연구 (A Study on the Application Plan of Air-Conditioning and Renewable Complex Systems in the Small Schools.)

  • 김지연;박효순;홍성희;김성실;허인구;서승직
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.946-951
    • /
    • 2009
  • The research aims to study a new, optimum and renewable energy application method that can cover the minimum energy and operation costs within a range of school budgets. By deriving the optimum application method, it is expected to maximize the cooling/heating and water heating energy saving efficiencies for educational facilities. Therefore, this research carried out a study on the new/renewable energy utilization technique diffusion expansion method and the optimum method. As a result, the first optimum plan was introduced with the multi-type geothermal heat pump 174kW + solar heat collector $94\;m^2$ + highly efficient electronic cooling/heating device (EHP) 249.4kW. On the other hand, the second optimum plan was induced as the multi-type geothermal heat pump 255.2kW + highly efficient electronic cooling/heating device (EHP) 168.2kW.

  • PDF

대규모 고등학교의 냉난방 및 신재생에너지시스템 적용방안에 관한 연구 (A Study on the Application Plan of Air-Conditioning and New and Renewable Systems in the Large High Schools)

  • 김지연;박효순;김성실;서승직
    • 설비공학논문집
    • /
    • 제21권10호
    • /
    • pp.564-574
    • /
    • 2009
  • The study is conducted to study a new, optimum and new and renewable energy application method that can cover the minimum energy and operation costs within a range of school budgets. By deriving the optimum application method, it is expected to maximize the cooling/heating and hot water supply energy saving efficiencies for educational facilities. Therefore, this research implemented a study on the new and renewable energy utilization technique diffusion expansion method and the optimum method. As a result, the first optimum plan was introduced with the multi-type geothermal heat pump 475.6 kW+highly efficient electronic cooling/heating device(EHP) 545.2 kW. On the other hand, the second optimum plan was induced as the multi-type geothermal heat pump 261kW+solar heat collector $240\;m^2$+highly efficient electronic cooling/heating device(EHP) 759.8 kW.