• 제목/요약/키워드: Geothermal Well

검색결과 185건 처리시간 0.026초

스탠딩컬럼웰(SCW)을 적용한 지열히트펌프의 성능에 대한 매개변수 연구 (A parametric study on the performance of heat pump using standing column well(SCW))

  • 장재훈;박두희
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.625-630
    • /
    • 2010
  • Parametric study was performed using the SCW numerical model for evaluating the performance of the SCW. The five ground related parameters, which are porosity, hydraulic conductivity, thermal conductivity, specific heat, geothermal gradient, and five SCW design parameters, which are pumping rate, well depth well diameter, dip tube diameter, bleeding rate, were used in the study. Numerical simulations were performed for short-term (24-hour) simulation. The study results indicate that the parameters that have important influence on the performance of SCW were hydraulic conductivity, thermal conductivity, geothermal gradient, pumping rate, and bleeding rate. Overall, this study showed that various factors had a cumulative influence on the performance of the SCW, and a numerical simulation can be used to accurately predict the performance of the SCW.

  • PDF

기대지열온도하에서 GDHS의 경제성분석 사례연구 (A Case Study for the Economic Feasibility Model and Analysis of a GDHS Given Geothermal Temperature)

  • 양문희;김태유;이상규
    • 대한산업공학회지
    • /
    • 제23권1호
    • /
    • pp.115-127
    • /
    • 1997
  • A GDHS(Geothermal District Heating System) is a heating system supplying a group of districts with heat extracted from geothermal sources. The advantages of GDHS include saving fuel consumption as well as reducing air pollution. This paper presents a case study for the economic feasibility model and analysis of a GDHS with which central/individual heating systems are replaced. Configuring to a simplified GDHS which consisits of subsurface systems, surface systems, and transmission/distribution systems, we find out the properties of the system and the model parameters affecting the initial investment/operating costs in order to develop a classical economic feasibility model given geothermal temperature. Based on our model parameter space, we analyzed the geothermal development project of the Jejoo Island probabilistically given prior information such as the expected geothermal power, the demand size and the length of transmission/distribution pipes.

  • PDF

국내의 지열에너지 열펌프 시스템 활용현황과 활성화 방안 (Application and Revitalization Method of Domestic Geothermal Heat Pump System)

  • 박혜리;고영호;김민태;박종일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.922-927
    • /
    • 2009
  • Due to the law of use of sustainable alternative energy recently legislated, many public institutions are ordered to use renewable energy. So it gets people's eyes on Geothermal energy system among other suggested renewable energy. Since there is hardly existence of a volcanic region, Geothermal heat pump system is generally used most in Korea. However, the important technology and materials are not localized and further, with only our technical skills it is arduous to popularize and develop Geothermal energy because of lack of revitalization related to the law and the regime for locally suitable Data-base. Moreover, an access of renewable energy is too much hard because of people's low interests about Geothermal energy. But fortunately, the well-studied about Geothermal heat system started to be adopted in many other provinces. Therefore, we study this with intend to popularize and develop Geothermal energy.

  • PDF

인공저류층 생성을 위한 유도진동에 관한 사전연구 (Review on the induced seismic event for artificial reservoir)

  • 전종욱;명우호;김영득
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.55-60
    • /
    • 2012
  • In many cases, geothemal wells will not be opened up a geothermal reservoir under such conditions that an extraction of geothermal energy is economically viable without any further measures. Geothermal wells often have to be stimulated, in order to increase productivity. For the non-volcanic area, such as Korea, the hydraulic stimulation is necessary to complete geothermal power plant. The analysis of induced seismic event showed that the thermal resource might have a much wider extent and a much higher generation potential than previously assumed. In order to record compressional and shear waves emitted during fracture stimulation, three-component geophones are placed in a seismometer. The recorded data from one seismometer is the convolution of the source magnitude, the transmission media, and the sensitivity of the instrument.

지반 투수계수와 양수량 조건이 복수정 지열 히트펌프 시스템의 성능에 미치는 영향 (The Effect of Soil Permeability and Pumping Rate on Performance of Two-well Geothermal Heat Pump System)

  • 조정흠;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제11권4호
    • /
    • pp.28-34
    • /
    • 2015
  • The groundwater heat pump (GWHP) systems have great potential for heating-cooling system which use annual constant groundwater temperature for heat source. Generally, the performance of GWHP system significantly depends on the geological and hydraulic properties such as hydraulic conductivity, thermal conductivity, soil condition so on. Therefore, in order to use GWHP systems efficiently, it is necessary to analyze the effect of design factors on the system performance. However, there are a few researches on the optimum design method for the open-loop geothermal system. In this research, the design factor in the open-loop geothermal system was analyzed quantitatively for the optimal design method by using numerical simulation. As a result, it was found that the temperature change of heat source depends on the design factor.

지하수 이용 지열 히트펌프 시스템의 주거용 건물 적용시 난방성능 특성에 관한 연구 (A Study on the Heating Performance of SCW Type Geothermal Heat Pump System for Residential House)

  • 김주화;김주영;홍원화;안창환
    • 한국주거학회논문집
    • /
    • 제19권5호
    • /
    • pp.11-18
    • /
    • 2008
  • Geothermal heat pump system using sanding column well type with their ground heat exchanger can be used as a highly efficient source of heating and cooling in massive buildings. But there is no case of a small scale residential house. So in the residential house this study estimated heating coefficient of performance (COP) of geothermal heat pump system using sanding column well type which is excellent in heat recovery. As a result of analysis, The COP of heat pump is over average 6 and is excellent. And in consequence of making a comparative study according to the bleeding, the COP is higher in the case of bleeding. Therefore, bleeding affects the performance of the system. This study has shown performance result that stands on actual data. Therefore, this study provides ground data that needs when a low capacity of system designs for a residence with confidence elevation.

Balancing Well 교차혼합 지중열교환기의 스마트 냉난방 히트펌프 시스템의 성능평가에 관한 연구 (Study on the Performance Evaluation of Smart Heating and Cooling Heat Pump System in a Balancing Well Cross-Conditioned Ground Heat Exchanger)

  • 이창희;김동규;유병석;김부일
    • 신재생에너지
    • /
    • 제16권4호
    • /
    • pp.41-48
    • /
    • 2020
  • This study performed a single hole operation method using a balancing well-cross-mixed underground heat exchanger, and conducted thermal performance studies of an SCW-type underground heat exchanger using a two-well. The study attempted to change the existing operating method of the two adjacent SCW underground heat exchangers with one ball each. The SCW-type geothermal heat exchanger is considered to enable up to 20% of bleed discharge at maximum load, which makes groundwater usage unequal. The efficiency factor of the geothermal system was improved by constructing the discharged water by cross-mixing two balancing wells to prevent the discharge of groundwater sources and keep the temperature of the underground heat exchanger constant. As a result of the cooling and heating operation with the existing SCW heat exchange system and the balancing well-cross-mixed heat exchange system, the measured performance coefficient improved by 23% and 12% in cooling and heating operations, respectively. In addition, when operating with a balanced cross-mixing heat exchange system, it has been confirmed that the initial basement temperature is constant with a standard deviation of 0.08 to 0.12℃.

개방형 지열 시스템 설계법 개발을 위한 관정 주위 지중 온도 환경 검토 (Study on the Underground Thermal Environment around Wells for a Design Method of Open-Loop Geothermal System)

  • 배상무;김홍교;김현우;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권1호
    • /
    • pp.14-20
    • /
    • 2017
  • Groundwater heat pump (GWHP) system can achieve higher performance of the system by utilizing heat source of the annual constant groundwater temperature. The performance of GWHP system depends on the ground thermal environment such as groundwater temperature, groundwater flow rate and hydraulic conductivity. In this study, the geothermal environment was analyzed by using numerical simulation for develop the two-well geothermal system. As the result, this paper shows the change of the groundwater level and underground temperature around wells according to the conditions of flow rate and hydraulic conductivity.