• Title/Summary/Keyword: Geometry factor

Search Result 505, Processing Time 0.024 seconds

Load Concentration Factor Analysis of Fuel Assembly Guide Thimble (핵연료집합체 안내관의 하중집중계수 해석)

  • Lee Young-Shin;Jeon Sang-Youn
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.93-100
    • /
    • 2005
  • The top and bottom nozzles of PWR fuel assembly are connected by guide thimbles and an instrumentation tube that are connected with spacer grids. The fuel rods are inserted into the each cell of spacer grids. The loads acting on the fuel assembly are transmitted to the guide thimbles through the flow plate of top nozzle The axial loads applied to the fuel assembly are not equally distributed among the guide thimble due to the geometry of the top nozzle flow plate and spacer grid. In this study, the load concentration factors for the $17\times17$ fuel assembly were calculated. The analytical model fur the calculation of the load concentration factor of top nozzle flow plate was developed using ANSYS 5.6. The finite element analyses were performed using the model composed of top nozzle, guide thimble, and spacer grid. And, the analysis results were compared with the test results.

A Study on the Fatigue Characteristics of Accelerated Cooled TMCP Steel's Welded Joint with High Heat Input (가속냉각형 TMCP강재 대입열 용접부의 피로특성)

  • 윤중근;김희진
    • Journal of Welding and Joining
    • /
    • v.6 no.1
    • /
    • pp.28-34
    • /
    • 1988
  • The fatigue test was carried out to evaluate the fatigue characteristics of the accelerated cooled (ACC) TMCP steel and its welded joint. From this study, it was confirmed that ACC TMCP steel has higher fatigue strength than conventional steels. After welding, however, the fatigue strength of ACC TMCP steel was deteriorated associated with HAZ softening when weld reinforcement was removed. On the other hand, with weld reinforcement, there is no effect of HAZ softening on the fatigue strength of welded joint because it is strongly dependant on the detail weld geometry i.e., stress concentration factor. Accordingly the fatigue strength of actual welded joint increases with decreasing the stress concentration factor of welded joint, regardless of HAZ softening.

  • PDF

A STEADY FLOW MODEL OF A MAGNETIC FLUX TUBE CONSTRAINED TO OBSERVED DIFFERENTIAL EMISSION MEASURE

  • BONG SU-CHAN;CHAE JONGCHUL;YUN HONG SIK
    • Journal of The Korean Astronomical Society
    • /
    • v.33 no.3
    • /
    • pp.159-163
    • /
    • 2000
  • We have investigated one dimensional steady flow model of a typical magnetic flux tube in the solar transition region constrained to observed Differential Emission Measure (DEM) for the average quiet-Sun deduced by Raymond & Doyle (1981) with a flux tube geometry conforming to Doppler shifts of UV lines measured by Chae, Yun & Poland (1998). Because local heating and filling factor in the transition region are not well known, we considered two extreme cases, one characterized by the filling factor= 1 ('filled-up model') and the other set by local heating=0 ('not-heated model'). We examined how much the heating is required for the flux tube by recomputing a model through adjustment of the filling factor in such a way that 'not-heated model' accounts for the observed DEM.

  • PDF

A Numerical Study on Flow Characteristics of a Honeycomb seal (Honeycomb Seal의 유동 특성 해석)

  • Hong, E.;Hur, N.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.153-157
    • /
    • 2000
  • Honeycomb seals are used widely in gas turbines due to their good sealing performance and rotor-dynamic stability. Three-Dimensional complex flows in a honeycomb seal were analyzed in the present study. Friction factors were computed to predict the performance of a honeycomb seal based on pressure drop results for various honeycomb cell geometry and Reynolds numbers. Computed results for friction factor are compared to the available experimental data. Unlike in the experiment, where 'Friction-Factor Jump' phenomena are reported for some cases, computed results show no jump phenomena. The friction factors, however, are in good agreement with the experiment in no-jump cases.

  • PDF

Local stress field for torsion of a penny-shaped crack in a transversely isotropic functionally graded strip

  • Feng, W.J.;Su, R.K.L.
    • Structural Engineering and Mechanics
    • /
    • v.18 no.6
    • /
    • pp.759-768
    • /
    • 2004
  • The torsion of a penny-shaped crack in a transversely isotropic strip is investigated in this paper. The shear moduli are functionally graded in such a way that the mathematics is tractable. Hankel transform is used to reduce the problem to solving a Fredholm integral equation. The crack tip stress field is obtained by taking the asymptotic behavior of Bessel function into account. The effects of material property parameters and geometry criterion on the stress intensity factor are investigated. Numerical results show that increasing the shear moduli's gradient and/or increasing the shear modulus in a direction perpendicular to the crack surface can suppress crack initiation and growth, and that the stress intensity factor varies little with the increasing of the strip's height.

A Study on the Effect of Stress Concentration Factor Determined by 3D-ESPI System on the Fatigue Life (3D-ESPI 시스템을 이용하여 결정된 응력집중계수가 피로수명에 미치는 영향에 관한 연구)

  • 김경수;심천식
    • Journal of Ocean Engineering and Technology
    • /
    • v.16 no.1
    • /
    • pp.46-51
    • /
    • 2002
  • Fatigue life estimation by the theoretical stress concentration factors are, in general, considerably different from test results. And in calculating stress concentration factor, it is very difficult to consider actual geometry and material property which are the notch shapes, imperfections or defects of materials such as porosities inclusions and casting defects, etc. Therefore, the paper deals with the experimental method to find out the more exact stress concentration factors by measuring the strain distributions on each specimen by 3D-ESPI(Electronic Speckle Pattern Interferometry) System. Then the fatigue lives are compared between theoretical calculations using stress concentration factors determined by 3D-ESPI system and fatigue test results.

Selection of Canonical Factors in Second Order Response Surface Models

  • Park, Sung H.;Seong K. Han
    • Journal of the Korean Statistical Society
    • /
    • v.30 no.4
    • /
    • pp.585-595
    • /
    • 2001
  • A second-order response surface model is often used to approximate the relationship between a response factor and a set of explanatory factors. In this article, we deal with canonical analysis in response surface models. For the interpretation of the geometry of second-order response surface model, standard errors and confidence intervals for the eigenvalues of the second-order coefficient matrix play an important role. If the confidence interval for some eigenvalue includes 0 or the estimate of some eigenvalue is very small (near to 0) with respect to other eigenvalues, then we are able to delete the corresponding canonical factor. We propose a formulation of criterion which can be used to select canonical factors. This criterion is based on the IMSE(=Integrated Mean Squared Error). As a result of this method, we may approximately write the canonical factors as a set of some important explanatory factors.

  • PDF

Flow and Heat Transfer Characteristics due to Staggered Arrangement of Heat Pipes in Channels with Heat Pipes and Fins (휜-히트파이프로 구성된 채널에서 히트파이프의 엇갈림배열에 따른 유동 및 열전달 특성)

  • 김성훈;진윤근;김철주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.871-879
    • /
    • 2002
  • The characteristics of flow and heat transfer in the heat exchanger of heat pipes with fins have been studied numerically for cooling enhancement of electronic components of KTX (Korea Train eXpress). Numerical analysis and methodology have been conformed by comparing the experimental results for inlined array of heat pipes. The staggered arrangement of heat pipes has been proposed in order to achieve heat transfer enhancement. As results, the geometry change to the staggered array is conformed to increase the heat transfer of the system accompanied by an increase of pressure drop. The current results of friction factor and Colburn j factor are presented in terms of Reynolds number and staggered distance, and are expected to use for design and manufacture of such a system.

Stress Analysis of Truss Connection subjected to Moving Load Using Section Properties Factor (단면 수정계수를 이용한 이동 하중에 따른 트러스 연결부의 응력해석)

  • 이상호;배기훈
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.354-361
    • /
    • 2002
  • This paper propose section properties factor to generate stress history for fatigue analysis and safety inspection of steel bridge. A methodology is described for the computation of numerical stress histories in the steel truss bridge, caused by the vehicles using section properties factor. The global 3-D beam model of bridge is combined with the local shell model of selected details. Joint geometry is introduced by the local shell model. The global beam model takes the effects of joint rigidity and interaction of structural elements into account. Connection nodes in the global beam model correspond to the end cross-section centroids of the local shell model. Their displacements are interpreted as imposed deformations on the local shell model. The load cases fur the global model simulate the vertical unit force along the stringers. The load cases fer the local model are imposed unit deformations. Combining these, and applying vehicle loads, numerical stress histories are obtained. The method is illustrated by test load results of an existing bridge.

  • PDF

A solution method of view factor by the area weighted average and graphical methods (면적가중 평균법과 그래프 해법에 의한 형태계수의 해석)

  • 유승호;손장열
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.709-715
    • /
    • 1999
  • To optimize a heating and cooling system, we need an exact solution lot radiant heat transfer in any form of room or building. This paper describes the solution method of view factor by the area weighted average and graphical method to calculate the radiant heat exchange or daylighting level in any form of room or building. This study shows that the area weighted average and graphical methods have many points of merits(calculation speed, correctness and calculation capability in an arbitrary form of room shapes etc.) compared with existing methods

  • PDF