• 제목/요약/키워드: Geometrical ray

검색결과 103건 처리시간 0.027초

Understanding spin configuration in the geometrically frustrated magnet TbB4: A resonant soft X-ray scattering study

  • Huang, H.;Jang, H.;Kang, B.Y.;Cho, B.K.;Kao, C.C.;Liu, Y.J.;Lee, J.S.
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1205-1211
    • /
    • 2018
  • The frustrated magnet has been regarded as a system that could be a promising host material for the quantum spin liquid (QSL). However, it is difficult to determine the spin configuration and the corresponding mechanism in this system, because of its geometrical frustration (i.e., crystal structure and symmetry). Herein, we systematically investigate one of the geometrically frustrated magnets, the $TbB_4$ compound. Using resonant soft x-ray scattering (RSXS), we explored its spin configuration, as well as Tb's quadrupole. Comprehensive evaluations of the temperature and photon energy/polarization dependences of the RSXS signals reveal the mechanism of spin reorientation upon cooling down, which is the sophisticated interplay between the Tb spin and the crystal symmetry rather than its orbit (quadrupole). Our results and their implications would further shed a light on the search for possible realization of QSL.

6MV X-선 검출특성 조사를 위하여 유전체 필름을 이용하여 제작한 평행판 검출기의 유용성 (Feasibility Study of Parallel- Plate Detector Using Dielectric film for 6 MV X-ray)

  • 조문준;김용은;이병용;김정기;임상욱;김현수;김기환
    • 한국의학물리학회지:의학물리
    • /
    • 제15권2호
    • /
    • pp.105-111
    • /
    • 2004
  • 본 연구에서는 의료용 선형가속기로부터 발생되는 명목상 가속전압 6 MV선의 검출특성을 확인하기 위하여 유전체 물질을 사용한 평행판 검출기를 제작하였다. 제작한 검출기의 전극은 단면이 크롬으로 코팅되어 있는 FEP유전체 필름(두께: 100 $\mu\textrm{m}$)을 사용하였고 두 전극 사이에 PTFE유전체 필름(두께 : 100 $\mu\textrm{m}$)을 삽입하였다. 측정을 위하여 선원-팬텀 표면간의 거리 100 cm, 그리고 팬텀의 표면으로부터 깊이 5 cm되는 지점에 방사선 유도전하를 획득하기 위한 제작검출기를 놓았다. 방사선 조사시 제작검출기의 유용성을 알아보기 위하여, 영점 변동, 누설 전류, 인가전압에 따른 검출기의 반응, 재현성, 선형성, 조직최대선량비 등을 측정하였다. 측정결과 검출기의 영점 변동 전류 (I$_{Z}$ )는 8.3 pA, 누설 전류(I$_{I}$)는 10 pA 이었다. 제작 검출기는 인가전압에 대한 선형성을 보였으며, 또한 재현성실험에서는 조사된 선량에 대하여 1% 오차 범위 내에서 일치하였다. 검출기의 선량에 대한 선형성은 3% 이내의 오차범위에서 일치하면서 선량율 의존성이 있음을 확인하였다. 조직최대선량비분포에 대한 제작 평행판 검출기와 비교검출기간의 선량오차는 팬텀내의 최대 선량점으로부터 7.5 cm까지 3% 이내에서 일치하였다. 본 연구결과 유전체 필름을 이용한 평행판 검출기는 선량계로서의 기본적인 특성들을 허용 가능한 범위에서 만족스러워 상대선량측정을 위한 검출기로 사용할 수 있음을 확인할 수 있었다.

  • PDF

초음파 tomography를 응용한 콘크리트 구조물의 비파괴 시험에 관한 연구 (Application of Ultrasound Tomography for Non-Destructive Testing of Concrete Structure)

  • 김영기;윤영득;윤종열;김정수;김운경;송문호
    • 대한전자공학회논문지SP
    • /
    • 제37권1호
    • /
    • pp.27-36
    • /
    • 2000
  • 본 연구에서는 초음파와 tomography 기법을 기반으로 콘크리트 구조물의 비파괴 시험에 대한 방법론을 정립하고 검증하였다 일반적인 X-ray tomography에서는 물체를 통과하는 파동의 감쇠(attenuation) 데이터에 기초를 두고있는 반면에, 본 연구에서는 time-of-flight(TOF) 데이터를 사용하여 매질의 굴절률(refractive index)을 포괄적으로 표현하는 단층영상을 복원한다 X-ray tomography에서는 측정된 감쇠 데이터를 영상복원(Image reconstruction) 알고리즘에 의해서 처리하며, 파동의 굴절은 고려할 필요가 없다 그러나 초음파는 매질(medium)의 굴절률(refractive index)에 따라 초음파의 경보가 변경되므로 초음파 tomography에서는 초음파 경로의 연산이 선행되어야만 단층영상을 복원할 수 있게 된다 초음파 정보의 연산은 가하광학(Geometrical Optic)에서 사용되는 굴절률과 경로의 관계에 기초를 둔다 영상 복원은 대수학적 접근 방법인 ART (algebraic reconstruction technique) 또는 SIRT(simultaneous iterative reconstruction technique)를 기초로 연산된 초음파의 경로를 따라 선적분한 TOF 값과 측정된 TOF 값의 차이를 기반으로 수행된다 실제 구현에서는 초음파가 직진한다는 가정하에 영상을 복원하고, 이를 기반으로 초음파의 경로를 연산하였다 본 논문에서는 이들 두 과정(경로연산 및 영상복원)의 반복연산을 통하여 영상을 복원하였다. 세안하는 알고리즘을 모의실험으로 평가하였고, 실제 콘크리트 구조물에 적용하여 본 방법론의 무한한 가능성을 입증하였다.

  • PDF

Changes in High Degree p-mode Parameters with Magnetic and Flare Activities

  • Maurya, Ram Ajor
    • 천문학회보
    • /
    • 제38권2호
    • /
    • pp.89.2-89.2
    • /
    • 2013
  • Solar energetic transients, e.g., flares, CMEs, etc., release large amount of energy which is expected to excite acoustic waves (p-modes) by exerting mechanical impulse of the thermal expansion of the flare on the photosphere. We study the p-mode properties of flaring and dormant active regions (ARs) to find association between flare and p-mode parameters. We compute the magnetic and flare activity indices of ARs using the line-of-sight magnetograms and GOES X-ray fluxes, respectively. The p-mode parameters are computed from the ring-diagram analysis. We correct p-mode parameters for magnetic field, filling factors and foreshortening by multiple linear-regression analysis. Our analysis of several flaring and dormant ARs observed during the Carrington rotations 1980-2109, showed strong association of mode parameters with magnetic and flare activities. We find that the mode parameters are contaminated by the geometrical effect. Mode amplitude decreases with angular distance from the solar disc centre. The mode width increases with magnetic activity while amplitude showed opposite relation due to mode absorption by the sunspot. After correcting modes due to all geometrical effects, magnetic activity and filling factor, we find that the modes amplitude, and mode energy increases with flare energy while width shows opposite relation.

  • PDF

팔라듐에서의 변형 및 수소흡수거동에 미치는 형상 및 가공의 영향 (Effect of Geometrical shape and Cold work on Deformation and Hydrogen absorption behaivor in Palladium)

  • 정영관;김경훈;김세웅
    • 한국수소및신에너지학회논문집
    • /
    • 제12권4호
    • /
    • pp.247-255
    • /
    • 2001
  • The relation between the deformation and the geometrical shape, and the effect of cold work on the hydrogen absorption behavior in palladium were investigated. The Pd specimens used were plates and wires as cold worked and annealed states. The palladium plates and wires were loaded with hydrogen by electrochemical method. Experimental analyses were carried out through X -ray diffraction, micrometer measurement and decimal balance measurement. As the results, it is found that the effect of cold work on hydrogen absorption capacity was relatively small. The deformation of the palladium plates in thickness direction is larger than in other lateral directions whereas the palladium wires showed the same deformation ratio in all radius directions because of the circular distribution of coexisting $\alpha$ and $\beta$ phases. The products of plastic deformation such as slip lines and voids etc. were observed abundantly in all specimens although the specimens had undergone only once of a hydrogen absorption and desorption.

  • PDF

SABA (secondary structure assignment program based on only alpha carbons): a novel pseudo center geometrical criterion for accurate assignment of protein secondary structures

  • Park, Sang-Youn;Yoo, Min-Jae;Shin, Jae-Min;Cho, Kwang-Hwi
    • BMB Reports
    • /
    • 제44권2호
    • /
    • pp.118-122
    • /
    • 2011
  • Most widely used secondary structure assignment methods such as DSSP identify structural elements based on N-H and C=O hydrogen bonding patterns from X-ray or NMR-determined coordinates. Secondary structure assignment algorithms using limited $C{\alpha}$ information have been under development as well, but their accuracy is only ~80% compared to DSSP. We have hereby developed SABA (Secondary Structure Assignment Program Based on only Alpha Carbons) with ~90% accuracy. SABA defines a novel geometrical parameter, termed a pseudo center, which is the midpoint of two continuous $C{\alpha}s$. SABA is capable of identifying $\alpha$-helices, $3_{10}$-helices, and $\beta$-strands with high accuracy by using cut-off criteria on distances and dihedral angles between two or more pseudo centers. In addition to assigning secondary structures to $C{\alpha}$-only structures, algorithms using limited $C{\alpha}$ information with high accuracy have the potential to enhance the speed of calculations for high capacity structure comparison.

차량용 헤드램프의 Cut-off Line에서 색수차 보정 및 평가 (Correction and Evaluation for Color Aberration on the Cut-off Line of a Vehicle Headlamp)

  • 심주용;박성찬
    • 한국광학회지
    • /
    • 제30권1호
    • /
    • pp.8-14
    • /
    • 2019
  • 본 논문에서는 추가적인 광학부품 및 조립공정 없이 차량용 헤드램프의 cut-off line에서 발생하는 색수차를 보정하는 방법과 이를 평가하는 방법을 제안한다. 기하학적인 방법으로 색수차를 보정하기 위해 비구면 프로젝션 렌즈의 볼록면에 tilt를 적용하여 파장별 최대 출사각도의 차이를 줄였으며, 색수차를 평가하기 위한 위치와 광도를 정하고 색 좌표를 통해 색수차 기준을 제시하였다. 이러한 기하학적인 방법을 이용하여 설계된 자동차용 헤드램프를 평가한 결과 cut-off line의 색수차가 상당히 감소되었음을 확인할 수 있었다.

변조전달함수 측정에 있어 기하학적 조정 불량이 해상도에 미치는 영향 (Effects of the Geometrical Misalignment on the MTF Measurement)

  • 김준우
    • 한국방사선학회논문지
    • /
    • 제15권5호
    • /
    • pp.705-713
    • /
    • 2021
  • 엑스선 영상 시스템으로부터 획득한 영상의 공간주파수에 대한 해상도를 분석하기 위해 변조전달함수(modulation-transfer function, MTF)를 계산한다. 일반적으로 검출기의 응답함수는 슬릿-카메라를 사용하여 선분포함수(line-spread function, LSF)를 획득하고, 푸리에 변환을 거쳐 변조전달함수를 도출한다. 엑스선이 항상 슬릿-카메라 중심에 입사해야 된다는 조건 때문에 실험자에 의해 발생하는 검출기와 슬릿-카메라의 기울임은 검출기 성능에 영향을 미치게 된다. 이와 더불어 기울임에 확대율이 더해진다면 엑스선 영상 시스템의 성능평가에 문제가 발생할 것이다. 본 연구에서는 실험적 오차에 기인하여 이를 변조전달함수, 즉 푸리에 도메인에서 실험과 분석모델을 해석하였고, 공간주파수에 미치는 영향을 분석하였다. 나아가 다양한 엑스선 영상 시스템에 있어 성능평가가 실시되어야 할 것이고, 실험적 오차는 불가결하게 발생하며 이를 허용할 수 있는 범위에 대한 검토가 이루어져야 한다.

균일 회절 이론을 이용한 선박 환경에서의 단말기 사용자 쉐도잉 분석 기법 (User-Body Shadowing Analysis Technique in Ship Environment Based on the Uniform Geometrical Theory of Diffraction)

  • 김창회;정재훈;이성로;김성철
    • 한국통신학회논문지
    • /
    • 제39C권11호
    • /
    • pp.1209-1215
    • /
    • 2014
  • 기하학적 균일 회절 이론(UTD)은 특정 주파수에서 장애물에 의해 전파가 불연속적인 특성을 가질 때, 전자기학적으로 접근하여 회절 계수와 반사 계수 등을 계산하여 전파를 분석하는 기법이다. 본 논문에서는 실내 무선 채널 환경에서 사용자가 단말기 주변에 있을 때, 사용자에 의한 쉐도잉(Shadowing) 효과를 기하학적 UTD을 통하여 분석하였다. 사용자가 통화를 하고 있는 상황(Head Model)과 가슴 앞쪽에 단말기를 위치하여 사용하는 상황(Chest Model)으로 나누고, 각각에 대하여 복사 모델(Radiation Model)과 산란 모델(Scattering Model)에 적용하여 비교 및 분석하였다.

Quality Assurance System for Determination of Center Position in X-ray and Proton Irradiation Fields using a Stainless Ball and Imaging Plates in Proton Therapy at PMRC

  • Yasuoka, Kiyoshi;Ishikawa, Satoko
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.189-191
    • /
    • 2002
  • In the proton therapy using a gantry system, periodical verification of iso-center position is very important to assure precision of patient positioning system at any gantry angles in proton treatment. In the gantry system, there are three different types of iso-center; 1) in a geometrical view, 2) in an X-ray beam's eye view, 3) in a proton beam's eye view. Idealistically, they would be an identical point. They could, however, be different points. It may be a source of errors in patient positioning. At PMRC, we have established a system of verification for iso-center positions using a stainless ball of 2-cm in diameter and an imaging plate. This system provides the relation among a center of a patient target position, a center of proton irradiation field, and/or a center of X-ray field in accuracy of 50$\square$m in the 2) and 3) views, as images of a center of the stainless ball and a center of a 100 mm${\times}$100 mm-aperture brass collimator recorded on the imaging plate, which is setup at 1-cm behind the ball. In addition, it provides simultaneously the images of the ball and the collimator on an imaging intensifier (II), which is setup downstream of the proton or X-ray beam. We present a method of quality assurance (QA) for calibration of iso-center position in a rotation gantry system at PMRC and the performance of this system. A proton beam position on the 1$\^$st/ scatterer in the nozzle of the gantry affects less sensitive (reduced by a factor of 1/5) to the results of the iso-center position. The effect is systematically correctable. The effect of the nozzle (or the collimator) position is less than 0.5 mm at the maximum extraction (390 mm).

  • PDF