• 제목/요약/키워드: Geometric mean

검색결과 754건 처리시간 0.027초

치과위생사들의 요중 수은함량과 관련요인 분석 (Determinants of Urinary Mercury Concentration among Dental Hygienists)

  • 이명주;장봉기;최재호;심현주;이종화
    • 한국산업보건학회지
    • /
    • 제21권2호
    • /
    • pp.90-98
    • /
    • 2011
  • Objectives: The aim of this study was to evaluate the level of urinary mercury and analyze which factors would affect urinary mercury concentration among dental hygienists in dental clinics. Methods: This study conducted by questionnaire and detection of urinary mercury concentration of 268 dental hygienists working in dental clinics from July to August of 2009. Data collected from two hundred and thirty-five dental hygienists were analyzed by the geometric mean (GM). Analytical results of urine samples with less than 0.3 g creatinine/L and greater than 3g creatinine/L were excluded from statistical analysis. Results: Urinary mercury concentration of 235 dental hygienists showed the geometric distribution. The arithmetic and geometric means of urinary mercury concentration were $0.996{\mu}g/g$ creatinine and $0.755{\mu}g/g$ creatinine, respectively. From multiple regression analysis, the number of amalgam filling, the consumption frequency of raw fish and the number of amalgam handling in current workplace was revealed as increasing factors of urinary mercury concentration. Conclusions: The level of urinary mercury in dental hygienists was higher than in general Korean population. The number of amalgam filling, the consumption frequency of raw fish and the number of amalgam handling in current workplace was revealed as increasing factors of urinary mercury concentration. Therefore using resin materials instead of amalgam in dental clinics is highly desirable.

파쇄프랙탈차원을 이용한 밭토양 내수성입단과 대공극률의 관계 평가 (Relationship between Water Stable Aggregate and Macroporosity in Upland Soils Calculated by Fragmentation Fractal Dimension)

  • 한경화;조현준;이협성;허승오;하상건
    • 한국토양비료학회지
    • /
    • 제42권1호
    • /
    • pp.58-64
    • /
    • 2009
  • 본 연구는 밭토양 내수성입단의 계절별 특성을 밝히고 파쇄프랙탈차원을 이용하여 대공극률과의 관계를 구명코자 수행하였다. 대상 토양은 토성이 다른 세 지점으로 고평통 (Fine, Typic Hapludalfs), 규암통 (Fine silty over coarse silty, Fluvaquentic Eutrudepts), 중동통(Coarse loamy, Typic Udifluvents)으로 경기도에 위치하였다. 봄, 여름, 가을에 불교란 시료를 채취하고 내수성입단과 대공극률, 토양이화학성을 측정하였다. 내수성입단은 파쇄프랙탈차원($D_f$), 기하평균지름(GMD), 중량평균지름(MWD)의 세 가지로 계수화하였다. $D_f$는 MWD보다 GMD와 상관이 높게 나타났고, 무차원의 입단파쇄과정에 근거하여서 실험에 사용한 입단크기와 전처리과정의 영향을 덜 받아 내수성입단의 계수화에 적절하다고 판단할 수 있었다. 계절적으로 내수성입단은 여름>봄>가을순으로 나타났고 생물활성과 토양수분의 영향으로 파악할 수 있었다. $D_f$ 3.1이하의 토양에서 $D_f$와 대공극률과역의 상관관계를 나타냈으며 특히 $99{\mu}m$ 이상의 공극률과 상관이 높았으며 $D_f$ 3.1이상의 토양에서는 상관이 나타나지 않았다. 또한 $D_f$ 3.1이하의 토양에서는 대공극률과 포화수리전도도의 누승함수 적합도가 높게 나타났다. 따라서 내수성입단의 파쇄프랙탈차원은 입단화에 의한 대공극형성과 해석에 유용하다고 판단할 수 있었다.

부산 내 미세먼지 고농도 지역 탐색 및 체내 휘발성유기화합물 바이오모니터링 조사 (Exploration of an Area with High Concentrations of Particulate Matter and Biomonitoring Survey of Volatile Organic Compounds among the Residents)

  • 주현지;이승호;민재희;황용식;홍영습
    • 한국환경보건학회지
    • /
    • 제49권6호
    • /
    • pp.344-352
    • /
    • 2023
  • Background: With its developed port and related industries, the concentration of fine dust is high in Busan compared to other cities in South Korea. Many studies have reported the health effects of fine dust, but there has been a lack of information regarding concentrations of volatile organic compounds among those who exposed to high levels of fine dust. Objectives: This study aimed to define an area with high concentrations of particulate matter and perform biomonitoring surveys among the residents of the area. Methods: Air quality data was collected and the mean level of each district in Busan was derived. We then defined the area with the highest concentrations of PM10 as a target site. Urine samples were collected from the 400 participants and analyzed for VOCs metabolites - trans,trans-Muconic Acid (t,t-MA) and N-AcetylS-(benzyl)-L-cysteine (BMA). Interviews were conducted by trained investigators to examine demographic information. The levels of t,t-MA and BMA were compared with representative South Korean population data (Korean National Environmental Health Survey). The association of the VOC metabolites and fine dust were analyzed by general linear regression analysis. Results: The mean of PM10 in the target site was 42.50 ㎍/m3 from 2018 to 2020. Among the 400 participants in the target site, 74.8% were female and the average age of the participants was 66 years. The geometric mean of t,t-MA was 71.15 ㎍/g creatinine and the BMA was 7.00 ㎍/g creatinine among the residents. The levels were higher than the geometric mean from the 4th KoNEHS. The levels of t,t-MA showed significance in BMI, smoking status, and household income. BMA showed significance in gender and age. Conclusions: Compared to the general population of South Korea, the target site's residents had higher biomonitoring levels. Based on this study, continuous screening for high risk areas, including the target site, and biomonitoring of the residents are required.

Increase In Mean Alveolar Pressure Due To Asymmetric Airway Geometry During High Frequency Ventilation

  • Cha, Eun-J.;Lee, Tae-S.;Goo, Yong-S.;Song, Young-J.
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권1호
    • /
    • pp.89-96
    • /
    • 1993
  • During high frequency ventilation (HFV), mean alveolar pressure has been measured to increase with mean airway opening pressure controlled at a constant level in both humans and experimental animals. Since this phenomenon could potentiate barotrauma limiting advantages of HFV, the present study theoretically predicted the difference between menu alveolar and airway opening pressures ($MP_{alv}$). In a Weibel's trumpet airway model, approximated formula for $MP_{alv}$ was derived based on momentum conservation assuming a uniform velocity profile. The prediction, equation was a func pion of gas density($\rho$), mean flow rate(Q), and diameter of the airway opening where the pressure measurement was made($D_0$) : $MP_{alv}=4{\rho}(Q/D_0^{2})^2$. This was a result of the difference in crosssectional area between the alveoli and the airway opening. A simple aireway model experiment was performed and the results well fitted to the prediction, which demonstrated the validity of the present analysis. Previously reported $MP_{alv}$ data from anesthetized dogs in supine position were comparable to the predicted values, indicating that the observed dissociation between mean alveolar and airway opening pressures during HFV can be explained by this innate geometric (or cross-sectional area) asymmetry of the airways. In lateral position, however, the prediction substantially underestimated the measurements suggesting involvement of other important physiological mechanisms.

  • PDF

HYPERSURFACES WITH PRESCRIBED MEAN CURVATURE IN MEASURE METRIC SPACE

  • Zhengmao Chen
    • 대한수학회보
    • /
    • 제60권4호
    • /
    • pp.1085-1100
    • /
    • 2023
  • For any given function f, we focus on the so-called prescribed mean curvature problem for the measure e-f(|x|2)dx provided thate-f(|x|2) ∈ L1(ℝn+1). More precisely, we prove that there exists a smooth hypersurface M whose metric is ds2 = dρ2 + ρ2d𝜉2 and whose mean curvature function is ${\frac{1}{n}}(\frac{u^p}{{\rho}^{\beta}})e^{f({\rho}^2)}{\psi}(\xi)$ for any given real constants p, β and functions f and ψ where u and ρ are the support function and radial function of M, respectively. Equivalently, we get the existence of a smooth solution to the following quasilinear equation on the unit sphere 𝕊n, $${\sum_{i,j}}({{\delta}_{ij}-{\frac{{\rho}_i{\rho}_j}{{\rho}^2+|{\nabla}{\rho}|^2}})(-{\rho}ji+{\frac{2}{{\rho}}}{\rho}j{\rho}i+{\rho}{\delta}_{ji})={\psi}{\frac{{\rho}^{2p+2-n-{\beta}}e^{f({\rho}^2)}}{({\rho}^2+|{\nabla}{\rho}|^2)^{\frac{p}{2}}}}$$ under some conditions. Our proof is based on the powerful method of continuity. In particular, if we take $f(t)={\frac{t}{2}}$, this may be prescribed mean curvature problem in Gauss measure space and it can be seen as an embedded result in Gauss measure space which will be needed in our forthcoming papers on the differential geometric analysis in Gauss measure space, such as Gauss-Bonnet-Chern theorem and its application on positive mass theorem and the Steiner-Weyl type formula, the Plateau problem and so on.

크롬 취급 사업장의 작업환경 및 근로자 폭로 실태에 관한 연구 (A Study of Working Environments and Workers Exposed to Chromium)

  • 유병철;손병철;전진호;손혜숙;한용수;이채언;정운
    • Journal of Preventive Medicine and Public Health
    • /
    • 제27권3호
    • /
    • pp.517-530
    • /
    • 1994
  • For the purpose of providing the basic data for health management of workers who are exposed to chromium and for improving the quality of working environment, the authors evaluated blood and urinary level of chromium, the occupational history. AST, ALT, Hb, Hct, nasal specular examinaton on 287 workers who have been dealed chromium compounds in 56 manufacturing Industries of five types, that is, 38 metal plating services(plating),4 manufacture of other fabricated metal products (fabricated metal product), 5 manufacturing of dyestuff(dyestuff), 6 dressing and dyeing of leather(leather), 3 others(manufacture of pottery and ceramic househod wares, motor vehicles, electronic valves and tubes and other electronic components) and also measured the level of chromium in air from February to October 1993. The results were as follows ; 1. The utilized type of chromium compounds was the hexavalent state in plating fabricated metal product dyestuff, leather and the trivalent state in .other, and atmosperic chromium concentration as geometric mean was $0.0138mg/m^3(0.001{\sim}0.068mg/m^3)$ in plating, $0.0115mg/m^3(0.006{\sim}0.015mg/m^3)$ in fabricated matal product, $0.068mg/m^3(0.002{\sim}0.019mg/m^3)$ in dyestuff, $0.0083mg/m^3(0.002{\sim}0.028mg/m^3)$ in leather $0.0039mg/m^3(0.003{\sim}0.005mg/m^3)$ in other by the type of industry and it exceeded TLV-TWA ($0.05mg/m^3$) in five (13.6%) of plating services. 2. The geometric mean of chromium in blood was $1.54{\mu}g/dl(0.10{\sim}3.62{\mu}g/dl)$ in Plantng, $0.94{\mu}g/dl(0.27{\sim}2.82{\mu}g/dl)$ in fabricated metal product, $0.51{\mu}g/dl(0.10{\sim}3.25{\mu}g/dl)$ in dyestuff, $0.87{\mu}g/dl(0.15{\sim}8.00{\mu}g/dl)$ in leather, $0.55{\mu}g/dl(0.20{\sim}2.28{\mu}g/dl)$ in other by the type of industry(p<0.001). 3. The geometric mean of chromium in urine was $14.47{\mu}g/l(6.90{\sim}28.00{\mu}g/l)$ in planting, $4.63{\mu}g/l(0.24{\sim}43.00{\mu}g/l)$ in fabricated metal product, $5.93{\mu}g/l(1.00{\sim}33.00{\mu}g/l)$ in dyestuff, $11.09{\mu}g/l(0.80{\sim}48.00{\mu}g/l)$ in leather, $12.41{\mu}g/l(10.10{\sim}41.00{\mu}g/l)$ in other by the type of industry(p<0.001). 4. As the result of nasal specular examination, twenty four cases (8.4%) of nasal septal perforation among 287 total subjects was observed, and there were 17 (9.7%) cases in plating, 4 csaes (14.3%) in dressing and dyeing of leather. In the comparison of chromium concentration in blood and urine between the perforated group and non-perforated group, the perforated group showed a significantly higher value as $1.883{\pm}3.055{\mu}g/dl\;and\;0.793{\pm}0.815{\mu}g/dl$(P<0.001), $21.31{\pm}34.610{\mu}g/L\;and\;9.304{\pm}11.079{\mu}g/L$ (P<0.001). 5. The mean concentration of chromium in blood, urine and the mean level of AST, ALT, Hb and Hct in exposure group were higher than those of control group(p<0.001).

  • PDF

신장 방사선 섭취량 결정을 위한 Conjugate View 방법에 대한 평가 (Evaluation of a Conjugate View Method for Determination of Kidney Uptake)

  • 봉정균;윤미진;이종두;김희중;손혜경;권윤영;박해정;김유선
    • 대한핵의학회지
    • /
    • 제39권3호
    • /
    • pp.191-199
    • /
    • 2005
  • 목적: 본 연구의 목적은 신장의 정확한 방사능 섭취량을 얻기 위해서 기하학적 평균 감쇠보정을 이용한 conjugate view 방법(CVM)을 평가하고 Gate 방법과 비교하는 것이다. 대상 및 방법 : 본 연구는 신장의 방사능 섭취량을 시뮬레이션하기 위해서 몬테칼로 코드, SIMIND와 Zubal 팬텀을 사용하였다. 또한 이중 감마카메라를 이용하여 직경 5cm인 팬텀들을 직경 20cm인 실제 팬텀에 삽입하여 실험을 하였다. CVM 방법을 평가하기 위해서 산란과 감쇠가 없는 이상적 데이터와 비교되었다. 또한, CVM 방법을 Gate 방법과 비교하였고, 산란보정의 적용 또는 비적용으로 나누어 CVM 방법을 실행하였다. Gate 방법은 임상에서 사용하는 것처럼 산란보정을 적용하지 않았으며, $0.12cm^{-1}$$0.15cm^{-1}$ 감쇠계수들을 적용하였다. 관심영역 내에 있는 평균계수, 신장영상 위에서 얻어진 프로파일, 선형회귀분석을 이용하여 데이터를 분석하였고, 이상적 데이터와의 상관계수를 계산하였다. 결과: 컴퓨터 시뮬레이션의 경우, 이상적 데이터, CVM 방법, Gate 방법으로부터 얻어진 평균계수들은 각각 (오른쪽: $998{\pm}209$, 왼쪽: $896{\pm}249$), (오른쪽: $911{\pm}207$, 왼쪽: $815{\pm}265$), (오른쪽: $1065{\pm}267$, 왼쪽 $1546{\pm}267$)이었다. CVM 방법은 이상적 데이터와 좋은 상관관계를 보여주었고, 이상적 데이터와 대한 CVM 방법, Gate방법의 상관계수는 각각 (오른쪽: 0.91, 왼쪽: 0.93)와 (오른쪽: 0.85, 왼쪽 0.90)이었다. 결론: 기하학적 평균 감쇠보정을 이용한 CVM 방법은 Gate 방법보다 정량적으로 더 정확한 값을 제공하였다. 결론적으로, 신장 깊이에 영향을 받지 않는 CVM 방법으로 더욱 정확하게 신장의 방사능 섭취량을 측정할 수 있을 것으로 생각된다.

다양한 노출 매트릭스를 통한 송전선로 주변과 비 주변 거주 초등학교 학생의 극저주파 자기장 노출량 평가에 관한 연구 (Exposure Assessment of Extremely Low Frequency Magnetic Fields by variable exposure matrices for the Selected Primary Schoolchildren Living Nearby and Away from a Overhead Transmission Power Line)

  • 김윤신;현연주;최성호;이철민;노영만;조용성;홍승철
    • 한국산업보건학회지
    • /
    • 제16권4호
    • /
    • pp.334-345
    • /
    • 2006
  • The objectives of this study were to analyze and compare 24 hrs personal exposure levels of MF at microenvironments such as home, school, educational institute, internet pc game room, transportation, and other places according to time activity patterns using various metrics for children attending the primary schools located near and away from the power lines, and to characterize the major microenvironments and impact factors attributed personal exposure level. The study was carried out for 44 children attending a primary school away from the lines(school A) and 125 children attending a school away from 154 kV power lines(school B), all who aged 12 years and were 6 grade, from July 2003 to December 2003. All participants filled in a questionnaire about characteristics, residence, use of electrical appliances and others. Children wore a small satchel in which EMDEX II and Lite (Enertech, Co. Ltd) and a diary of activity list for period of registration in 20 minutes blocks. All statistical calculations were made with the SAS System, Releas 6.12. The summary of results was presented below. First, about the characteristics of subjects, there no differences between two groups. The subject almost spent about 56 % of their time at home and about 20~25 % of their time at school. Fifty percent of children spent 2 hours at private educational institutes. Second, the personal exposure measurements of children in school B was statistically higher than those of children in school A by various metrics such as arithmetic mean, geometric mean, percentile(5, 25, 50, 75, 95), maximum, rate of change metric, constant field metric. The arithmetic and geometric mean magnetic fields during the time the children were at school B were 0.98 and $0.86{\mu}T$ and were about 23 times higher than those of children were at school A. In conclusion, the significant major determinants of personal exposure level is the distance from the power line to microenvironments.

직업적인 크롬 노출이 혈중 Homocysteine, Folate와 Vitamin B12 농도에 미치는 영향 (Effects of Occupational Chromium Exposure on Plasma Homocysteine, Folate and Vitamin B12 Concentration)

  • 김기웅;김규상;박인정;강성규;오성수;정효석;장성근
    • 한국산업보건학회지
    • /
    • 제16권3호
    • /
    • pp.245-253
    • /
    • 2006
  • We evaluated the relations among exposure and urinary levels of Cr, folate, vitamin $B_{12}$ and Hcy levels in the workers chronically exposure to Cr. Subjects were 104 male employees, 65 workers exposed to Cr in 9 electroplating plants and 39 office workers who had never been occupationally exposed to hazardous substances including Cr. The geometric mean(GM) of Cr in workplace was $0.069{\pm}0.101mg/m^3$ and urinary Cr was $0.483{\pm}0.394mg/g$ creatinine and airborne Cr concentration was significantly correlated to the urinary concentration of Cr(r=0.900, p=0.000). The geometric mean concentration of urinary Cr in control group was $0.301{\pm}0.255mg/g$ creatinine. In comparing the workers exposed to Cr with controls, significantly higher mean plasma levels were found of Hcy($11.3{\pm}4.9$ vs $9.4{\pm}4.7{\mu}mol/{\ell}$, p=0.05), but vitamin $B_{12}$ levels ($181.8{\pm}68.7$ vs $216.0{\pm}64.3nmol/{\ell}$, p=0.01) was significantly decreased. Hcy concentrations correlated positively with airborne Cr concentrations(r=0.287, p=0.004) and urinary Cr concentrations(r=0.244, p=0.015) but folate concentrations correlated negatively with airborne(r=-0.234, p=0.020) and urinary Cr concentrations(r=-0.640, p=0.090), respectively. No correlations were observed between vitamin $B_{12}$, airborne and urinary Cr concentrations. Also, Hcy concentrations correlated positively with vitamin $B_{12}$(r=0.295, p=0.0020 and negatively with folate concentrations(r=-0.196, p=0.046). The various biological(i.e. age and serum indicates) or lifestyle factors(i.e. medication, smoking, alcohol and coffee intake), also taken into account as potential confounders, did not influence the correlations found. Thus, this study found evidence that Cr might be associated with elevated plasma levels of Hcy. Furthermore, elevated plasma levels of Hcy were significantly associated with folate and vitamin $B_{12}$ concentration.

톨루엔 폭로근로자의 혈장중 마뇨산과 공기중 톨루엔과의 상관관계 (The Relationship Between Hippuric Acid in Blood Plasma and Toluene Concentration in the Air of Workplace)

  • 황천현;이원진;장성훈;김형아
    • Journal of Preventive Medicine and Public Health
    • /
    • 제33권1호
    • /
    • pp.45-50
    • /
    • 2000
  • Objectives : This study was undertaken to evaluate correlation between the levels of hippuric acid in blood plasma (HAP) and those of toluene concentration in the workplace air. Methods : Study subjects were composed of two groups; 21 workers who were occupationally exposed to toluene and 25 rural-area residents who were not exposed to any known occupational toluene source, as an exposed group and a reference group, respectively. Mean age and work duration of the exposed was 42 years and five years, respectively. Mean age of the reference was 42 years. To determine toluene concentrations in the workplace air, air sampling has been conducted for more than six hours using a personal sampler, and analyzed by a gas chromatography-flame ionization detector. Concentrations of hippuric acid in biological samples were determined by a high performance liquid chromatography-ultraviolet detector. Results : Geometric mean(geometric standard deviation) of HAP and hippuric acid in urine(HAU) for the exposed was 1.39(2.21) mg/L and 2.77(1.46) g/L, respectively, which were significantly different from those of the reference [HAP, 9.45(2.94); HAU, 0.37(0.45)]. Teluene concentration in the workplace air was 86.92(range: $45.18\sim151.23$)ppm. The level of HAP or HAU was significantly correlated (r=0.70 and r=0.63, respectively) with that of toluene in the workplace air. The estimated regression equation was logHAP(mg/L)=-3.60+1.93 log(toluene, ppm) or logHAU(g/L)=-0.85+0.67 log(toluene, ppm). The magnitude of correlation was further enhanced when analyzing relationship between toluene concentrations lower than 100 ppm and its corresponding HAP levels. Conclusion : Overall, plasma hippuric acid levels were well correlated with toluene concentrations in the workplace air, and a statistically significant correlation was observed for the samples with toluene concentration lower than 100 ppm.

  • PDF