• Title/Summary/Keyword: Geometric Tolerance

Search Result 67, Processing Time 0.028 seconds

The Effects of Geometrical Imperfections on the Dynamic Characteristics of a Tapered Roller Bearing Cage (테이퍼 롤러 베어링 케이지의 불완전성이 통특성에 미치는 영향)

  • Ahn, Tae-Kil;Park, Jang-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.464-469
    • /
    • 2019
  • Tapered roller bearings are used widely in vans, trucks, and trains because they can support the vehicle in a stable manner even under a heavy load. The cage of a tapered roller bearing maintains the gap between the rollers, which prevents friction wear and suppresses heating. If the cage is severely deformed due to resonance, the roller may not be able to roll smoothly and even leave the cage. Consequently, it is very important to analyze the dynamic characteristics of the cage for reliable performance of a bearing. The cage essentially has geometrical tolerance in the manufacturing process. In this paper, the effects of those geometrical imperfections on the dynamic characteristics of the cage were investigated. As a result, natural frequency separation occurred near the natural frequency of the ideal cage due to geometrical imperfections. In addition, the interval was proportional to the magnitude of the geometric error, and the interval increased with increasing mode number.

Analysis of the trueness and precision of complete denture bases manufactured using digital and analog technologies

  • Leonardo Ciocca;Mattia Maltauro;Valerio Cimini;Lorenzo Breschi;Angela Montanari;Laura Anderlucci;Roberto Meneghello
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.1
    • /
    • pp.22-32
    • /
    • 2023
  • PURPOSE. Digital technology has enabled improvements in the fitting accuracy of denture bases via milling techniques. The aim of this study was to evaluate the trueness and precision of digital and analog techniques for manufacturing complete dentures (CDs). MATERIALS AND METHODS. Sixty identical CDs were manufactured using different production protocols. Digital and analog technologies were compared using the reference geometric approach, and the Δ-error values of eight areas of interest (AOI) were calculated. For each AOI, a precise number of measurement points was selected according to sensitivity analyses to compare the Δ-error of trueness and precision between the original model and manufactured prosthesis. Three types of statistical analysis were performed: to calculate the intergroup cumulative difference among the three protocols, the intergroup among the AOIs, and the intragroup difference among AOIs. RESULTS. There was a statistically significant difference between the dentures made using the oversize process and injection molding process (P < .001), but no significant difference between the other two manufacturing methods (P = .1227). There was also a statistically significant difference between the dentures made using the monolithic process and the other two processes for all AOIs (P = .0061), but there was no significant difference between the other two processes (P = 1). Within each group, significant differences among the AOIs were observed. CONCLUSION. The monolithic process yielded better results, in terms of accuracy (trueness and precision), than the other groups, although all three processes led to dentures with Δ-error values well within the clinical tolerance limit.

Assessment on Accuracy of Stereotactic Body Radiation therapy (SBRT) using VERO (VERO system을 이용한 정위적 체부 방사선치료(SBRT)의 정확성 평가)

  • Lee, Wi Yong;Kim, Hyun Jin;Yun, Na Ri;Hong, Hyo Ji;Kim, Hong Il;Baek, Seung Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.17-24
    • /
    • 2019
  • Purpose: The present study aims to assess the level of coherency and the accuracy of Point dose of the Isocenter of VERO, a linear accelerator developed for the purpose of the Stereotactic Body Radiation Therapy(SBRT). Materials and Method: The study was conducted randomly with 10 treatment plans among SBRT patients in Kyungpook National University Chilgok Hospital, using VERO, a linear accelerator between June and December, 2018. In order to assess the equipment's power stability level, we measured the output constancy by using PTW-LinaCheck, an output detector. We also attempted to measure the level of accuracy of the equipment's Laser, kV(Kilo Voltage) imaging System, and MV(Mega Voltage) Beam by using Tofu Phantom(BrainLab, Germany) to assess the accuracy level of geometrical Isocenter. We conducted a comparative analysis to assess the accuracy level of the dose by using an acrylic Phantom($30{\times}30{\times}20cm$), a calibrated ion chamber CC-01(IBA Dosimetry), and an Electrometer(IBA, Dosimetry). Results: The output uniformity of VERO was calculated to be 0.66 %. As for geometrical Isocenter accuracy, we analyzed the error values of ball Isocenter of inner Phantom, and the results showed a maximum of 0.4 mm, a minimum of 0.0 mm, and an average of 0.28 mm on X-axis, and a maximum of -0.4 mm, a minimum of 0.0 mm, and an average of -0.24 mm on Y-axis. A comparison and evaluation of the treatment plan dose with the actual measured dose resulted in a maximum of 0.97 % and a minimum of 0.08 %. Conclusion: The equipment's average output dose was calculated to be 0.66 %, meeting the ${\pm}3%$ tolerance, which was considered as a much uniform fashion. As for the accuracy assessment of the geometric Isocenter, the results met the recommended criteria of ${\pm}1mm$ tolerance, affirming a high level of reproducibility of the patient's posture. The difference between the treatment plan dose and the actual measurement dose was calculated to be 0.52 % on average, significantly less than the 3 % tolerance, confirming that it obtained predicted does. The current study suggested that VERO equipment is suitable for SBRT, and would result in notable therapeutic effect.

A Study on the Evaluation of Simplification Algorithms Based on Map Generalization (지도 일반화에 따른 단순화 알고리즘의 평가에 관한 연구)

  • Kim, Kam-Lae;Lee, Ho-Nam;Park, In-Hae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.10 no.2
    • /
    • pp.63-71
    • /
    • 1992
  • The digital map database is often produced for multiple purposes, including mapping at multiple scales; it is increasingly rare that a base map is digitized for mapping at a single scale. The most important problems in process of line simplification in map generalization and multiple representation is that tolerance value selected for simplifying base map information must be modified as feature geometry varies within the digital file to ensure both accuracy and recognizability of graphic details on a generalized map. In this study, we explored various algorithms regarding to line simplication at many scales from a single digital file, and presents a rule by which to determine those scale at which line feature geometry might be expected to change in map representation. By applying two measured of displacement between a digitized line and its simplification, five algorithms have been evaluated. The results indicate that, of the five, the Douglas-Peucker routine produced less displacement between a line and its simplification. The research has proved to automating map simplification, incorporating numeric guidelines into digital environment about what magnitude and variation in geometric detail should be preserved as the digital data is simplified for representation at reduced map scales.

  • PDF

On the Performance Test of the Piezoelectric-Hydraulic Pump (압전유압펌프 성능실험에 대한 연구)

  • Joo, Yong-Hwi;Hwang, Jai-Hyuk;Yang, Ji-Youn;Bae, Jae-Sung;Lee, Jong-Hoon;Kwon, Jun-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.9
    • /
    • pp.822-829
    • /
    • 2015
  • In this paper, the piezoelectric-hydraulic pump with a piezostack actuator as a driving source has been designed, fabricated, and evaluated for its application to UAV's brake system. The performance requirements of the piezoelectric-hydraulic pump were decided based on the requirements analysis of the target aircraft brake system. The geometric design of the piezoelectric-hydraulic pump to meet the performance requirements of the pump was conducted, and all components of the pump including the spring sheet type check valves were machined with close tolerance. By constructing a test apparatus for the performance check of the piezoelectric-hydraulic pump, the performance characteristics of the pump, such as the outlet flow rate for load-free condition and the outlet oil pressure for closed loop condition, have been evaluated. It has been found by the performance test result that the developed piezoelectric-hydraulic pump satisfies the design requirements effectively.

Effects of Ammina on Survival and Growth of the Flounder Larva, Paralichthys olivaceus (넙치, Paralichthys olivaceus 자어의 생존과 성장에 미치는 암모니아의 영향)

  • KIM Hyung-Soo;KIM Heung-Yun;CHIN Pyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.3
    • /
    • pp.488-495
    • /
    • 1997
  • The effects of ammonia on survival and growth of the flounder larva, Paralichthys olivaceus, were examined by a static renewal bioassay method. The $96\;hr-LC_{50}$ with the developmental stages during the period from 1day to 23 day-old larvae ranged 0.273 to 1.023 mg $NH_3/\ell$. Tolerance of the larvae to ammonia toxicity was much sensitive at the early larval stage, and increased with the growth of the larvae. Threshold $96hr-LC_{50}$ in 1, 3 and S day-old larvae after hatching were 0.293, 0.248 and 0.379 mg $NH_3/\ell$, respectively. Survival rate and growth in body weight and body weight of the larva were reduced with increase of ammonia concentration in the range of 0.055 and 0.341 mg $NH_3/\ell$. The no-observable-effect concentration (NOEC) and lowest-observable- effect concentration (LOEC) of the flounder larve were 0.102 and 0.174 mg $NH_3/\ell$ for body length, and 0.151 and 0.198 mg $NH_3/\ell$ for body weight, respectively. Chronic value (ChV), which is the geometric mean of the NOEC and $NH_3/\ell$ to body length of the larvae were 0.124 mg $NH_3/\ell$. The coefficient of variation (CV) for body length was higher at high concentration than at low concentration.

  • PDF

Biological Study on the Increment of Survival Rate during Early Life Cycle in th Rockfish, Sebastes schlegeli (Telostei: Scorpaenidae) - I. Effects of Ammonia on Survival and Growth of the Larvae and Juveniles Stage (조피볼락, Sebastes schlegeli의 초기생활사 동안 생존율 향상을 위한 생물학적 연구 - I. 자어의 생존과 성장에 미치는 암모니아의 영향)

  • Chin, Pyung;Shin, Yun-Kyung;Kim, Hak-Gyoon;Lee, Jeong-Sick;Kim, Hyung-Soo
    • Korean Journal of Ichthyology
    • /
    • v.10 no.1
    • /
    • pp.98-105
    • /
    • 1998
  • The effect of ammonia on survival and growth of the larval rockfish, Sebastes schlegeli was examined by a static renewal bioassay method. The tolerance of larvae to ammonia toxicity was more sensitive at the early larvae, but increased with the development of larvae. In 14 day-old-larvae after parturition, the mortality with treatment of each concentration of ammonia was 5% at control group and 0.0112 $NH_3$mg/l, whereas it was increased up to 27.5% at exposure group of 0.1230 $NH_3$mg/l with higher concentration. Regression equation between ammonium concentration(X) and mortality(Y) was followed; Y=0.516+3.482 X($r^2=0.4737$, P<0.01). The NOEC(no-observable-effect concentration) and LOEC (lowest-observable-effect concentration) to mortality compared to control group were 0.100 $NH_3mg/l$ and 0.1230 $NH_3$mg/l, respectively and chronic value(ChV) which is the geometric mean of the NOEC and LOEC was 0.1110 $NH_3$mg/l. Body length after 7-days exposure in control group, 0.0112 $NH_3$mg/l and 0.1230 $NH_3$mg/l were 7.8325mm, 7.700mm and 7.05mm, respectively. The NOEC, LOEC and chronic value(ChV) were 0.0335 $NH_3$mg/l, 0.0558 $NH_3$mg/l and 0.0432 $NH_3$mg/l, respectively.

  • PDF